HOHaruyuki Ogino

Haruyuki Ogino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haruyuki Ogino has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Takatoshi Hattori

    Radiation Safety Research Center, Nuclear Technology Research Laboratory , Central Research Institute of Electric Power Industry (CRIEPI) , 2-11-1 Iwado-kita, Komae, Tokyo 201-8511 , Japan

    6 shared publications
  • Takeshi Ichiji

    Radiation Safety Research Center, Nuclear Technology Research Laboratory , Central Research Institute of Electric Power Industry (CRIEPI) , 2-11-1 Iwado-kita, Komae, Tokyo 201-8511 , Japan

    2 shared publications
  • K Yoshida

    Radiation Safety Research Center, Nuclear Technology Research Laboratory, Central Research Institute of Electric Power Industry, 2-11-1, Iwado Kita, Komae-shi, Tokyo 201-8511, Japan

    1 shared publication
  • M Sasaki

    Radiation Safety Research Center, Nuclear Technology Research Laboratory, Central Research Institute of Electric Power Industry, 2-11-1, Iwado Kita, Komae-shi, Tokyo 201-8511, Japan

    1 shared publication
  • Michiya Sasaki

    Central Research Institute of Electric Power Industry, Komae, Tokyo, Japan

    1 shared publication
  • Nobuyuki Hamada

    Central Research Institute of Electric Power Industry (CRIEPI)

    1 shared publication

Latest Publications

  • Open Access

    Quantitative assessment of provability of radiation-related cancers considering unavoidable existence of unadjusted risk factors

    by H Ogino, Y Fujimichi, M Sasaki, N Hamada, T Iwasaki, K Yoshida, T Hattori

    The attribution of stochastic effects to exposure to ionizing radiation has been qualitatively discussed by introducing two distinct concepts of provability and probability. This study aims to develop a method of quantitatively assessing the provability of radiation-related cancers. To this end, the 'minimum provable dose' (MPD) was developed and applied to actual cancer mortality in Japan. The background lifetime risk of cancer mortality was calculated for the esophagus, stomach, colon, liver, lungs, skin, breasts, ovaries, bladder, and bone marrow as well as the age-specific risk coefficients reproducing those given in the 2007 Recommendations of the International Commission on Radiological Protection (ICRP). Comparing the relative ratio of MPDs, which was defined herein as the 'provability index' (PI), we quantitatively ranked radiation-related cancers for different tissues and organs predicated on provability for ages of 10, 30, 50, and 0–85+ years at exposure. We discuss the radiological protection of male emergency workers focusing on cancers highly prioritized according to the ranking (i.e. colon, bone marrow, and bladder). The present study proposed the system to quantitatively evaluate the level of radiological protection taking into account the variations of the background cancer risk on the provability of radiation-related cancers.


  • Open Access

    Operational level for unconditional release of contaminated property from affected areas around Fukushima Daiichi nuclear power plant

    by Haruyuki Ogino, Takatoshi Hattori

    This paper focuses on the surface contamination control of slightly contaminated property after the Fukushima nuclear accident. The operational level for the unconditional release of contaminated properties is calculated in counts per minute (cpm) to enable the use of a typical Geiger-Muller (GM) survey meter with a 50-mm bore, on the basis of the surficial clearance level of 10 Bq cm−2 for 134Cs and 137Cs derived in the previous studies of the authors. By applying a factor for the conversion of the unit surface contamination to the count rate of a survey meter widely used after the Fukushima accident, the operational level for the unconditional release of contaminated properties was calculated to be 2300 cpm on average and 23 000 cpm at the highest-contamination part. The calculated numerical values of the operational levels are effective as long as the typical GM survey meter is used in the radiation measurement.


  • Open Access

    Verification of screening level for decontamination implemented after Fukushima nuclear accident

    by Haruyuki Ogino, Takeshi Ichiji, Takatoshi Hattori

    The screening level for decontamination that has been applied for the surface of the human body and contaminated handled objects after the Fukushima nuclear accident was verified by assessing the doses that arise from external irradiation, ingestion, inhalation and skin contamination. The result shows that the annual effective dose that arises from handled objects contaminated with the screening level for decontamination (i.e. 100 000 counts per minute) is −1, which can be considered as the intervention exemption level in accordance with the International Commission on Radiological Protection recommendations. Furthermore, the screening level is also found to protect the skin from the incidence of a deterministic effect because the absorbed dose of the skin that arises from direct deposition on the surface of the human body is calculated to be lower than the threshold of the deterministic effect assuming a practical exposure duration.


  • Validity of generic scenarios used in derivation of exemption levels for surface contamination considering transport-specific aspects

    by Haruyuki Ogino, Takatoshi Hattori

    The exemption levels for surface contamination in units of Bq cm−2 were derived by developing a new universal dose assessment model that consists of three generic scenarios assessed by considering manually, closely and remotely handled objects. In this paper, as part of the process of verifying the validity of these generic scenarios, annual doses that arise from transport-specific aspects are calculated. The maximum annual doses are found to be lower than 10 µSv, which is the bottom line of the exemption dose criterion. The result verifies the validity of the generic scenarios used in the previous derivation of exemption levels for surface contamination.


  • Practical judgment of exemption by applying isotope specific exemption levels for surface contamination

    by H. Ogino, T. Hattori

    In terms of applying the concept of exemption to safety standards for surface contamination, we have derived isotope specific exemption levels for surface contamination (Bq cm–2) by developing an original dose assessment model for surface contamination to develop reasonable radiation protection systems that reflect the radiological properties of nuclides and avoid excessive regulatory procedures. These exemption levels can be applied to the radiation, waste and transport safety fields by assuming a universal scenario and by applying radiation protection systems consistent with the current International Atomic Energy Agency (IAEA) Basic Safety Standards, safety series no. 115 and safety guide RS-G-1·7. In the case of materials containing a mixture of nuclides, the exemption can generally be judged on the basis of whether the condition ΣD/C0·1, were extracted following the 10% summation rule described by the European Commission in its document Radiation Protection 134. It was found that 60Co was the only important nuclide in most of the cases and other nuclides can be ignored according to the reasonable exemption levels for surface contamination derived in CRIEPI's previous study, where the α emitter was the most important nuclide in the case of estimating fuel damage by applying the exemption levels for surface contamination derived from the dose conversion factors given in IAEA TECDOC-1449. It is expected that the resulting reasonable exemption levels for surface contamination will be applied practically to future regulation and that consistent radiation protection systems will then be realised throughout the radiation, waste and transport safety fields.


  • Verification Test of Clearance Automatic Laser Inspection System for Surface Contamination Measurement

    by Michiya Sasaki, Haruyuki Ogino, Takeshi Ichiji, Takatoshi Hattori

    Recently, a clearance automatic laser inspection system (CLALIS) has been developed for clearance measurement of scrap metals and concrete debris. It utilizes three-dimensional laser scanning, gamma-ray measurement and Monte Carlo calculation, and its outstanding detection ability has been verified. In Japan, when an object is removed from a radiation-controlled area, the activity level must be lower than the surface contamination density standard of 4 Bq/cm2 for beta and gamma emitters, which is one-tenth of the surface contamination density limit. According to the clearance inspection report published by the Nuclear Safety Commission of Japan, the activity level of waste must be compared with not only the clearance level but also the surface contamination density standard for clearance inspection. To demonstrate that CLALIS can also be used for the measurement of surface contamination, a verification test was carried out using actual metal waste samples of various shapes, sizes and activity levels at Kashiwazaki-Kariwa Nuclear Power Station of Tokyo Electric Power Company. As a result, it was clarified that CLALIS gives a conservative value for surface contamination compared with the conventional GM survey meter measurement. This because the activities of metal waste samples were estimated using the total count rate, a fixed average surface area of 100 cm2 and the conservative source position assumed in the Monte Carlo calculation for the calibration factor. In a nuclear power plant, the actual judgment of whether an object can removed from a radiation-controlled area is based on whether the result of surface contamination measurement is lower than the detection limit, which is significantly lower than 4 Bq/cm2. According to this criterion, CLALIS provides an almost identical judgment to the GM survey meter, which means that CLALIS can be used as a rational clearance monitor to carry out clearance level and surface contamination inspections in a single radiation measurement. The prospective detection limit for CLALIS at nuclear power plants is also discussed and compared with that for the conventional surface contamination monitors.