TTTomasz S. Tkaczyk

Tomasz S. Tkaczyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomasz S. Tkaczyk has a total of 122 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Miniature 3D-printed rod-like refractive objective for endoscopic applications

    by Kevin Beckford, Yicheng Ma, Jinyun Liu, Tomasz S. Tkaczyk

    SignificanceThe three-dimensional (3D)-printed refractive rod objective for endoscopy preserves the compact, gradient index (GRIN)-like format while delivering a wide field of view (FOV) comparable to its diameter and larger than that of a commercial GRIN lens.AimWe focus on the design, fabrication, and experimental validation of a proof-of-concept refractive rod objective for fluorescence imaging of mouse colon tissue, with performance compared with a commercial GRIN lens.ApproachA 1× magnification refractive rod-like objective was designed in Zemax OpticStudio and fabricated using two-photon polymerization additive manufacturing. The objective consists of a sequence of convex refractive surfaces printed in contact at their vertices, with refractive index contrast provided by partially or non-polymerized resin contained within an enclosing wall. The lens has a diameter of 500 μm with a clear aperture of 470 μm, a total length of 2.06 mm, and a working distance of 1.6 mm and was optimized for a numerical aperture of 0.075 and a 500-μm design field at 525-nm light. Three photopolymer resins (IP-S, IP-Visio, and IPX-Clear) were evaluated through excitation–emission matrix measurements to assess autofluorescence. By imaging group 7, element 6 of a 1951 United States Air Force (USAF) resolution target, the field was assessed by plot profile and modulation transfer function measurements.ResultsThe fabricated objective resolved group 7, element 6 of a USAF resolution target (4.38 μm), closely matching the theoretical diffraction-limited resolution of 4.27 μm. Compared with a commercial 600-μm-diameter GRIN lens, the 3D-printed objective achieved a substantially larger FOV (498 versus 188 μm). Spectral characterization showed that IP-Visio exhibited the lowest autofluorescence under 455-nm excitation when unpolymerized resin was present. Using an IP-Visio objective, fluorescence images of proflavine-stained mouse colon tissue were successfully acquired.ConclusionsThe demonstrated refractive rod-like objective combines the compact geometry of a GRIN lens with the aberration correction capability of multi-element refractive optics, enabling uniform resolution across a large FOV. The approach also allows material selection tailored to fluorescence imaging requirements. Future work will focus on integration with fiber bundles and on fully polymerized designs with spatially tuned refractive index for improved long-term stability.


  • Hybrid endomicroscopic objective with monolithic multi-material achromatic triplet fabricated using two-photon lithography

    by Jinyun Liu, Roy Lycke, Lan Luan, Tomasz S. Tkaczyk

    We report a hybrid miniaturized achromatic objective for nonlinear endomicroscopy that combines two-photon polymerization (2PP)-fabricated polymer optics with a commercial glass lens. The objective achieves 0.6 numerical aperture with dual-wavelength correction at 775 and 860 nm and a 200 µm field of view, all within a 3 mm housing compatible with a hypodermic tube. Fabrication leverages sequential multi-step two-photon polymerization (2PP) to produce a monolithic multi-material triplet with submicron precision. The triplet incorporates two photoresists with different dispersion properties printed in successive steps with post-processing and marker-based realignment between steps, yielding a single monolithic optic that eliminates adhesives while correcting chromatic aberrations. Imaging tests with USAF resolution targets, biological samples, and two-photon fluorescence microscopy of pollen grains demonstrate near-diffraction-limited performance across the design wavelength range. The approach offers a practical method for compact optical systems in biomedical applications.

  • Fully 3D-printed endomicroscopic objective for two-photon, multi-wavelength excitation microscopy

    by Jinyun Liu, Roy Lycke, Lan Luan, Tomasz S. Tkaczyk

    We present a fully 3D-printed, broadband endomicroscopic objective optimized for near-infrared two-photon fluorescence imaging, featuring a compact, alignment-free design. The objective provides a numerical aperture of 0.6 in water immersion over a 200 µm field of view and maintains near diffraction-limited performance across the 720–950 nm excitation band. Monolithically fabricated with multi-material via two-photon polymerization (2PP), the three-element refractive objective achieves a 2 mm lens mechanical diameter, a mechanical housing diameter of 3 mm, and a total length of 2.1 mm with an approximately 10-hour build time. A self-aligning architecture integrates the printed half-housing with the optics to minimize assembly error, yielding sub-10 µm element decenter and <0.1° element tilt. Optical performance was validated using a resolution target and biological specimens, with broadband excitation behavior assessed by two-photon imaging of pollen grains across multiple excitation wavelengths, and with autofluorescence imaging of fresh mouse liver confirming feasibility for in situ tissue imaging. This work demonstrates the potential of fully printed broadband objectives for compact, high-performance endomicroscopy and integrated biomedical optics.


  • Open Access

    Flexible catheter optical coherence tomography of the porcine middle ear via the Eustachian tube using a 3D-printed reflective objective

    by Clayton B. Walker, Kevin Beckford, Zihan Yang, Jinyun Liu, Wihan Kim, Tomasz S. Tkaczyk, Brian E. Applegate

    SignificanceCholesteatomas, benign tumors that grow in the middle ear, can lead to conductive hearing loss. If not completely removed during surgery, these tumors may regrow. Current imaging technologies struggle to detect residual tumors noninvasively due to limitations in contrast and resolution, often necessitating additional surgery for inspection. To address this, we developed a catheter endoscope capable of being inserted through the Eustachian tube, allowing detailed examination of the middle ear without surgery. Using two-photon polymerization (2PP) technology, we fabricated miniature, side-viewing reflective endoscope objectives. This approach enabled the rapid production of single-element objectives with highly repeatable optical properties, easily adaptable to specific imaging needs.AimWe aim to design, fabricate, and demonstrate a catheter endoscope for optical coherence tomography (OCT) endoscopy of the middle ear via the Eustachian tube.ApproachSide-viewing, reflective lenses were designed in OpticStudio and 3D printed using 2PP followed by sputter coating with gold. Standard metrology techniques were used to verify and optimize the objective’s shape. The optical performance of the catheter endoscopes was measured with a beam profiler. Finally, OCT imaging of the middle ear of a pig via the Eustachian tube was completed using the fully assembled catheter endoscope.ResultsMetrology showed the printed lenses conformed closely to the design. The catheter endoscope’s FWHM spot size had a mean ± standard deviation of 25.3±1.8 μm with a measured working distance of 1.960±0.057 mm. Volumetric OCT images of the middle ear, inner ear, and Eustachian tube were captured in a postmortem pig head using the catheter endoscope.ConclusionsThe 2PP approach is fast and highly repeatable for miniature reflective objective fabrication. OCT catheter endoscopy via the Eustachian tube enabled imaging of the middle ear, Eustachian tube, and surprisingly part of the inner ear.


  • Snapshot hyperspectral imaging microscope enabled by cladded waveguide array fabricated with 2-photon additive manufacturing

    by Haimu Cao, Roger McNichols, Clayton B. Walker, Brian Applegate, Tomasz S. Tkaczyk

    Snapshot spectrometers capture spatial and spectral data in real-time, offering transformative potential in biomedical imaging and environmental monitoring. However, conventional designs struggle to reconcile high spatial-spectral sampling density with device miniaturization. To address this, we present a compact snapshot imaging spectrometer leveraging a densely packed 3D waveguide array fabricated via two-photon polymerization (2PP), an additive manufacturing technique that achieves submicron precision in complex geometries. The design features 26,000 straight waveguides in an angled end-face configuration, with a 4 µm pitch and 2.5 µm core size. By introducing a vertical layer height increment of 32 µm, the array facilitates spectral data distribution across 40 pixels. The compact structure, measuring 852 µm x 552 µm x 4093 µm, offers new opportunities for integrating snapshot spectroscopy into portable devices. The system's performance is evaluated through measurements of spectral resolution, crosstalk, and throughput. Validation using USAF resolution target imaging and the biological microscopic samples demonstrates its potential to deliver accurate and high-efficiency spectral data.

  • Imaging Snapshot Spectrometers enabled with 2-Photon Polymerization based Additive Manufacturing

    by Tomasz S Tkaczyk, Jiawei Lu, Haimu Cao

    The work presents examples of two imaging spectrometers enabled with 2-Photon Polymerization 3D printing. The presented spectrometers are field integral devices and image reorganization is achieved with high density waveguide array (waveguide spectrometer) or multifaceted, multi-angle mirror array respectively (Image Mapping Spectrometer - IMS). Fabricated components allow void spaces between image points dedicated for spectral information. High precision and repeatability of the fabricated components simplifies system calibration, improved image quality allows and more compact systems implementations.


  • High-spatial density snapshot imaging spectrometer enabled by 2-photon fabricated custom fiber bundles

    by Haimu Cao, Christopher Flynn, Brian Applegate, Tomasz S. Tkaczyk

    We report on a proof-of-concept snapshot imaging spectrometer developed using an array of optical fibers fabricated with 2-photon polymerization (2PP). The dense input array maps to an output array with engineered void spaces for spectral information. Previously, the development and fabrication of custom fiber arrays for imaging spectrometers have been a complex, time-consuming, and costly process, requiring a semi-manual assembly of commercial components. This work applies an automatic development process based on 2PP additive manufacturing with the Nanoscribe GmbH Quantum X system. The technique allows printing of arbitrary optical quality structures with submicron resolution with less than 5 nm roughness, enabling small core fibers/integrated arrays. Specifically, we developed an array prototype of 40 × 80 with 6-micron pitch at the input and 80-micron pitch at the output. The air-clad fibers had a core diameter of 5 µm. Fabricated optical fiber arrays were incorporated into a prism-based imaging spectrometer system with 48 spectral channels to demonstrate multi-spectral imaging. Imaging of a USAF target and color printed letter C as well as spectral comparisons to a commercial spectrometer were used to validate the performance of the system. These results clearly demonstrate the functionality and potential applications of the 3D-printed fiber-based snapshot imaging spectrometer.


  • Fabrication of waveguide directional couplers using 2-photon lithography

    by Christopher Flynn, Haimu Cao, Brian E. Applegate, Tomasz S. Tkaczyk

    Advances in 2-photon lithography have enabled in-lab production of sub-micron resolution and millimeter scale 3D optical components. The potential complex geometries are well suited to rapid prototyping and production of waveguide structures, interconnects, and waveguide directional couplers, furthering future development and miniaturization of waveguide-based imaging technologies. System alignment is inherent to the 2-photon process, obviating the need for manual assembly and allowing precise micron scale waveguide geometries not possible in traditional fused fiber coupler fabrication. Here we present the use of 2-photon lithography for direct printing of multi-mode waveguide couplers with air cladding and single mode waveguide couplers with uncured liquid photoresin cladding. Experimental results show reproducible coupling which can be modified by selected design parameters.


  • Fabrication of a multifaceted mapping mirror using two-photon polymerization for a snapshot image mapping spectrometer

    by Jiawei Lu, Xue Wen Ng, David Piston, Tomasz S. Tkaczyk

    A design and fabrication technique for making high-precision and large-format multifaceted mapping mirrors is presented. The method is based on two-photon polymerization, which allows more flexibility in the mapping mirror design. The mirror fabricated in this paper consists of 36 2D tilted square pixels, instead of the continuous facet design used in diamond cutting. The paper presents a detailed discussion of the fabrication parameters and optimization process, with particular emphasis on the optimization of stitching defects by compensating for the overall tilt angle and reducing the printing field of view. The fabricated mirrors were coated with a thin layer of aluminum (93 nm) using sputter coating to enhance the reflection rate over the target wave range. The mapping mirror was characterized using a white light interferometer and a scanning electron microscope, which demonstrates its optical quality surface (with a surface roughness of 12 nm) and high-precision tilt angles (with an average of 2.03% deviation). Finally, the incorporation of one of the 3D printed mapping mirrors into an image mapping spectrometer prototype allowed for the acquisition of high-quality images of the USAF resolution target and bovine pulmonary artery endothelial cells stained with three fluorescent dyes, demonstrating the potential of this technology for practical applications.


  • Visible and short-wave infrared fiber-based snapshot imaging spectrometer with a custom high-throughput relay system

    by Jiawei Lu, Desheng Zheng, Razvan-Ionut Stoian, Christopher Flynn, David Alexander, Tomasz S. Tkaczyk

    This paper presents the design and fabrication of a fiber-based snapshot imaging spectrometer working in both visible (490 nm-732 nm) and short-wave infrared (1090 nm - 1310 nm) ranges. To maximize the light collection efficiency, a custom relay system with 0.25 NA and 20 mm field of view (FOV) was designed and integrated. The bench setup showed that the custom relay system could fully resolve 10 µm fiber cores over the entire FOV among visible and short-wave infrared ranges. The numerical aperture (NA) match provided a 2.07X fold throughout improvement in the visible range and about 10X fold in the SWIR range compared to the previous generations, enabling imaging with a fast frame rate and under low illumination conditions. The presented imaging spectrometer generated spectral datacubes with 35000 spatial samplings and 23 spectral channels. Spectral urban imaging results obtained by the spectrometer in both visible and SWIR ranges are presented. Finally, we collected spectral images of apple bruising to show potential applications in the food quality industry.