CSChander Sadasivan

Chander Sadasivan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chander Sadasivan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Treatment of Rabbit Elastase-Induced Aneurysm Models by Flow Diverters: Development of Quantifiable Indexes of Device Performance Using Digital Subtraction Angiography

    by Chander Sadasivan, Liliana Cesar, Jaehoon Seong, Ajay K. Wakhloo, Baruch B. Lieber

    It has been known for more than a decade that intracranial aneurysms can be successfully treated by deploying a porous meshed tube in the parent vessel of the aneurysm. Such devices are currently called flow diverters because they promote intraneurysmal flow stasis and thrombosis by diverting blood flow away from the aneurysm sac. The objective of this study was to use angiographic data to quantify and compare the performance of flow diverters of original design in successfully occluding an experimental aneurysm model. Three different configurations of a novel flow diverter with varying porosities and pore densities were implanted in 30 rabbit elastase-induced aneurysms. Temporal variations in angiographic contrast intensity within the aneurysms were fit to a mathematical model. Optimized model parameters were supplemented by the angiographic percentage aneurysm occlusion and an angiographic measure of device flexibility to derive composite scores of performance. Angiographic quantification further suggested a parameter, which could be employed to estimate long-term aneurysm occlusion probabilities immediately after treatment. Performance scores showed that the device with a porosity of 70% and pore density of 18 pores/mm2 performed better than devices with 65% porosity, 14 pores/mm2, and 70% porosity, 12 pores/mm2 with relative efficacies of 100%, 84%, and 76%, respectively. The pore density of flow diverters, rather than porosity, may thus be a critical factor modulating device efficacy. A value of the prognostic parameter of less than 30 predicted greater than 97% angiographic aneurysm occlusion over six months with a sensitivity of 73% and specificity of 82%.


  • Correlation Between Angiographic and Particle Image Velocimetry Quantifications of Flow Diverters in an In Vitro Model of Elastase-Induced Rabbit Aneurysms

    by Asher L. Trager, Chander Sadasivan, Jaehoon Seong, Baruch B. Lieber

    The rupture of a cerebral aneurysm can result in a hemorrhagic stroke. A flow diverter, which is a porous tubular mesh, can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. By finding a correlation between particle image velocimetry (PIV) and digital subtraction angiography, a better assessment of how well an aneurysm is excluded from the parent artery can be made in the clinical setting. A model of a rabbit elastase-induced aneurysm was connected to a mock circulation loop. The model was then placed under angiography. Recorded angiograms were analyzed so that a contrast concentration-time curve based on the average grayscale intensity inside the aneurysm could be determined. That curve was then fitted to a mathematical model that quantifies the influence of convection and diffusion on contrast transport. Optimized parameters were correlated with the intraneurysmal mean kinetic energy measured by PIV in the same aneurysm model. A strong correlation was observed between the convection and diffusion time constants and the mean kinetic energy inside the aneurysm. Analyzing the flow of angiographic contrast into and out of the aneurysm after implantation of a flow diverter allows for prediction of the efficacy of the device in excluding the aneurysm. Correlating hydrodynamic measures obtained by angiography to those obtained by detailed techniques such as PIV increases confidence in such predictions.


  • Angiographic Assessment of the Performance of Flow Divertors to Treat Cerebral Aneurysms

    by Chander Sadasivan, Baruch B. Lieber, Liliana Cesar, Laszlo Miskolczi, Jaehoon Seong, Ajay K. Wakhloo

    Past clinical and experimental evidence suggests that cerebral aneurysms can be successfully excluded from the circulation solely by the endovascular placement of a flow diverting device across the aneurysm neck. These devices promote intraaneurysmal flow stasis and concomitant thrombosis by redirecting flow away from the aneurysm. To comprehensively test the efficacy of such flow divertors, we are implanting devices with three different porosities in a large cohort of elastase-induced aneurysms in rabbits. Treatment efficacy is quantified by a mathematical model that is fit to aneurysmal angiographic contrast washout curves. Results from three animals implanted with different device porosities are presented here. The model competently captures the behavior of the aneurysmal washout curves and provides reliable indices of device efficacy. Preliminary analysis indicates that immediately after implantation, the device with medium porosity performs better than the devices with lower and higher porosities


  • Angiographic Assessment of the Performance of Flow Divertors to Treat Cerebral Aneurysms

    by Chander Sadasivan, Baruch B. Lieber, Liliana Cesar, Laszlo Miskolczi, Jaehoon Seong, Ajay K. Wakhloo

    Past clinical and experimental evidence suggests that cerebral aneurysms can be successfully excluded from the circulation solely by the endovascular placement of a flow diverting device across the aneurysm neck. These devices promote intraaneurysmal flow stasis and concomitant thrombosis by redirecting flow away from the aneurysm. To comprehensively test the efficacy of such flow divertors, we are implanting devices with three different porosities in a large cohort of elastase-induced aneurysms in rabbits. Treatment efficacy is quantified by a mathematical model that is fit to aneurysmal angiographic contrast washout curves. Results from three animals implanted with different device porosities are presented here. The model competently captures the behavior of the aneurysmal washout curves and provides reliable indices of device efficacy. Preliminary analysis indicates that immediately after implantation, the device with medium porosity performs better than the devices with lower and higher porosities

    • 1 August 2002
      • Vol. 23  (7) , 1214-1221

    Angiographic Quantification of Contrast Medium Washout from Cerebral Aneurysms after Stent Placement

    by Chander Sadasivan, Baruch B. Lieber, Matthew J. Gounis, Demetrius K. Lopes, L. N. Hopkins

    BACKGROUND AND PURPOSE: Endovascular stent placement is an emerging technique in treating cerebral aneurysms. Thus far, no quantitative method is available to determine the effectiveness of stent deployment in reducing intraaneurysmal flow circulation, and thereby, in excluding the aneurysm from the cerebral vasculature. Our purpose was to develop a mathematical model congruent with flow transport phenomena observed in cerebral aneurysms and based on the washout of angiographic contrast medium from these aneurysms to provide quantitative indices for predicting the likelihood of stable thrombus formation after stent placement.