KDKurt R. Denninghoff

Kurt R. Denninghoff

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kurt R. Denninghoff has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prehospital Intubation is Associated with Favorable Outcomes and Lower Mortality in ProTECT III

    by Kurt R. Denninghoff, Tomas Nuño, Qi Pauls, Sharon D. Yeatts, Robert Silbergleit, Yuko Y. Palesch, Lisa H. Merck, Geoff T. Manley, David W. Wright

    Objective: Traumatic brain injury (TBI) causes more than 2.5 million emergency department visits, hospitalizations, or deaths annually. Prehospital endotracheal intubation has been associated with poor outcomes in patients with TBI in several retrospective observational studies. We evaluated the relationship between prehospital intubation, functional outcomes, and mortality using high quality data on clinical practice collected prospectively during a randomized multicenter clinical trial. Methods: ProTECT III was a multicenter randomized, double-blind, placebo-controlled trial of early administration of progesterone in 882 patients with acute moderate to severe nonpenetrating TBI. Patients were excluded if they had an index GCS of 3 and nonreactive pupils, those with withdrawal of life support on arrival, and if they had documented prolonged hypotension and/or hypoxia. Prehospital intubation was performed as per local clinical protocol in each participating EMS system. Models for favorable outcome and mortality included prehospital intubation, method of transport, index GCS, age, race, and ethnicity as independent variables. Significance was set at α = 0.05. Favorable outcome was defined by a stratified dichotomy of the GOS-E scores in which the definition of favorable outcome depended on the severity of the initial injury. Results: Favorable outcome was more frequent in the 349 subjects with prehospital intubation (57.3%) than in the other 533 patients (46.0%, p = 0.003). Mortality was also lower in the prehospital intubation group (13.8% v. 19.5%, p = 0.03). Logistic regression analysis of prehospital intubation and mortality, adjusted for index GCS, showed that odds of dying for those with prehospital intubation were 47% lower than for those that were not intubated (OR = 0.53, 95% CI = 0.36–0.78). 279 patients with prehospital intubation were transported by air. Modeling transport method and mortality, adjusted for index GCS, showed increased odds of dying in those transported by ground compared to those transported by air (OR = 2.10, 95% CI = 1.40–3.15). Decreased odds of dying trended among those with prehospital intubation adjusted for transport method, index GCS score at randomization, age, and race/ethnicity (OR = 0.70, 95% CI = 0.37–1.31). Conclusions: In this study that excluded moribund patients, prehospital intubation was performed primarily in patients transported by air. Prehospital intubation and air medical transport together were associated with favorable outcomes and lower mortality. Prehospital intubation was not associated with increased morbidity or mortality regardless of transport method or severity of injury.


  • Body Temperature after EMS Transport: Association with Traumatic Brain Injury Outcomes

    by Joshua B. Gaither, Vatsal Chikani, Uwe Stolz, Chad Viscusi, Kurt Denninghoff, Bruce Barnhart, Terry Mullins, Amber D. Rice, Moses Mhayamaguru, Jennifer J. Smith, et al.

    Introduction: Low body temperatures following prehospital transport are associated with poor outcomes in patients with traumatic brain injury (TBI). However, a minimal amount is known about potential associations across a range of temperatures obtained immediately after prehospital transport. Furthermore, a minimal amount is known about the influence of body temperature on non-mortality outcomes. The purpose of this study was to assess the correlation between temperatures obtained immediately following prehospital transport and TBI outcomes across the entire range of temperatures. Methods: This retrospective observational study included all moderate/severe TBI cases (CDC Barell Matrix Type 1) in the pre-implementation cohort of the Excellence in Prehospital Injury Care (EPIC) TBI Study (NIH/NINDS: 1R01NS071049). Cases were compared across four cohorts of initial trauma center temperature (ITCT): <35.0°C [Very Low Temperature (VLT)]; 35.0–35.9°C [Low Temperature (LT)]; 36.0–37.9°C [Normal Temperature (NT)]; and ≥38.0°C [Elevated Temperature (ET)]. Multivariable analysis was performed adjusting for injury severity score, age, sex, race, ethnicity, blunt/penetrating trauma, and payment source. Adjusted odds ratios (aORs) with 95% confidence intervals (CI) for mortality were calculated. To evaluate non-mortality outcomes, deaths were excluded and the adjusted median increase in hospital length of stay (LOS), ICU LOS and total hospital charges were calculated for each ITCT group and compared to the NT group. Results: 22,925 cases were identified and cases with interfacility transfer (7361, 32%), no EMS transport (1213, 5%), missing ITCT (2083, 9%), or missing demographic data (391, 2%) were excluded. Within this study cohort the aORs for death (compared to the NT group) were 2.41 (CI: 1.83–3.17) for VLT, 1.62 (CI: 1.37–1.93) for LT, and 1.86 (CI: 1.52–3.00) for ET. Similarly, trauma center (TC) LOS, ICU LOS, and total TC charges increased in all temperature groups when compared to NT. Conclusion: In this large, statewide study of major TBI, both ETs and LTs immediately following prehospital transport were independently associated with higher mortality and with increased TC LOS, ICU LOS, and total TC charges. Further study is needed to identify the causes of abnormal body temperature during the prehospital interval and if in-field measures to prevent temperature variations might improve outcomes.


  • Analysis of Automated External Defibrillator Device Failures Reported to the Food and Drug Administration

    by Lawrence A. DeLuca, Allan Simpson, Dan Beskind, Kristi Grall, Lisa Stoneking, Uwe Stolz, Daniel W. Spaite, Ashish R. Panchal, Kurt R. Denninghoff


  • Open Access

    Retinal oximeter for the blue-green oximetry technique

    by Kurt R. Denninghoff, Katarzyna B. Sieluzycka, Jennifer K. Hendryx, Tyson J. Ririe, Lawrence DeLuca, Russell A. Chipman

    Retinal oximetry offers potential for noninvasive assessment of central venous oxyhemoglobin saturation (SO2) via the retinal vessels but requires a calibrated accuracy of ±3% saturation in order to be clinically useful. Prior oximeter designs have been hampered by poor saturation calibration accuracy. We demonstrate that the blue-green oximetry (BGO) technique can provide accuracy within ±3% in swine when multiply scattered light from blood within a retinal vessel is isolated. A noninvasive on-axis scanning retinal oximeter (ROx-3) is constructed that generates a multiwavelength image in the range required for BGO. A field stop in the detection pathway is used in conjunction with an anticonfocal bisecting wire to remove specular vessel reflections and isolate multiply backscattered light from the blood column within a retinal vessel. This design is tested on an enucleated swine eye vessel and a retinal vein in a human volunteer with retinal SO2 measurements of ∼1 and ∼65%, respectively. These saturations, calculated using the calibration line from earlier work, are internally consistent with a standard error of the mean of ±2% SO2. The absolute measures are well within the expected saturation range for the site (–1 and 63%). This is the first demonstration of noninvasive on-axis BGO retinal oximetry.


  • Depolarization properties of the normal human fovea

    by Wai-Sze T. Lam, Russell A. Chipman, Karen M. Twietmeyer, Yanming Zhou, Kurt R. Denninghoff, A. E. Elsner, S. A. Burns

    Depolarization data is provided for several normal retinas. Mueller matrix images of normal human fovea were acquired with a custom imaging Mueller matrix retinal polarimeter (the GDx-MM) over a 9° field at 780nm and have been analyzed for depolarization index and the variation of degree of polarization with incident polarization state. The degree of polarization (DoP) was often above 50% and varied in complex ways as a function of the incident polarization states. The depolarization properties around the macula loosely correlated with the retardance image. High spatial frequency depolarizing structures were evident throughout the fovea.

    • 1 November 2008
      • Vol. 9  (4) , 184-189
    Open Access

    Emergent Endotracheal Intubation and Mortality in Traumatic Brain Injury

    by Kurt R. Denninghoff, Mervin J. Griffin, Alfred A. Bartolucci, Steven G. LoBello, Phillip R. Fine

    To determine the relationship between emergent intubation (emergency department and field intubation cases combined) and mortality in patients with traumatic brain injury while controlling for injury severity. Retrospective observational study of 981 (35.2% intubated, 64.8% not intubated) patients with TBI evaluating the association between intubation status and mortality. Logistic regression was used to analyze the data. Injury severity measures included Head/Neck Abbreviated Injury Scale (H-AIS), systolic blood pressure, type of head injury (blunt vs. penetrating), and a propensity score combining the effects of several other potential confounding variables. Age was also included in the model. The simple association of emergent endotracheal intubation with death had an odds ratio (OR) of 14.3 (95% CI = 9.4–21.9). The logistic regression model including relevant covariates and a propensity score that adjusted for injury severity and age yielded an OR of 5.9 (95% CI = 3.2–10.9). This study indicates that emergent intubation is associated with increased risk of death after controlling for a number of injury severity indicators. We discuss the need for optimal paramedic training, and an understanding of the factors that guide patient selection and the decision to intubate in the field.


  • Spectrophotometry of hydroxocobalamin and hemoglobin reveals production of an unanticipated methemoglobin variant

    by Kurt Denninghoff, Frank Gardner Walter, A.J. Langa, Yao He, Russell A. Chipman

    Cyanide-poisoned patients often require pulse oximetry and co-oximetry to measure oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin, and methemoglobin. These and other critical laboratory measurements can be confounded by the cyanide antidote hydroxocobalamin. The postulated mechanism of this confounding is direct optical interference. The spectra of swine hemoglobin with and without hydroxocobalamin were measured from 450-800 nm. The resulting complex spectrum was divided into hemoglobin, hydroxocobalamin, and a remainder spectrum. The remainder spectrum appears to be a methemoglobin variant quantitatively dependant on the amount of hydroxocobalamin added to the hemoglobin solution and the presence of oxygen. The Pearson's correlation coefficient comparing the known swine methemoglobin spectrum with the remainder spectrum reveals a very high degree of correlation (r(2) = 0.986). CONCLUSION. This is the first study to document methemoglobin formation caused by hydroxocobalamin. Further studies are needed in vitro and in vivo to assess this previously unreported methemoglobin variant.


  • Blue-green spectral minimum correlates with oxyhemoglobin saturation in vivo

    by Kurt R. Denninghoff, David A. Salyer, Sreenivasa Basavanthappa, Robert I. Park, Russell A. Chipman

    An imaging multi-spectral retinal oximeter with intravitrial illumination is used to perform the first in vivo test of the blue-green minima shift oximetry method (BGO) in swine eyes [K. R. Dennighoff, R. A. Chipman, and L. W. Hillman, Opt. Lett. 31, 924–926 (2006); J. Biomed. Opt. 12, 034020 (2007).] A fiber optic intravitreal illuminator inserted through the pars plana was coupled to a monochromator and used to illuminate the retina from an angle. A camera viewing through the cornea recorded a series of images at each wavelength. This intravitreal light source moves the specular vessel glint away from the center of the vessel and directly illuminates the fundus behind most blood vessels. These two conditions combine to provide accurate measurements of vessel and perivascular reflectance. Equations describing these different light paths are solved, and BGO is used to evaluate large retinal vessels. In order to test BGO calibration in vivo, data were acquired from swine with varied retinal arterial oxyhemoglobin saturations (60–100% saturation.). The arterial saturations determined using BGO to analyze the multispectral image sets showed excellent correlation with co-oximeter data (r2=0.98, and residual error ±3.4% saturation) and are similar to results when hemoglobin and blood were analyzed using this technique.


  • Blood oxyhemoglobin saturation measurements by blue-green spectral shift

    by Kurt R. Denninghoff, Russell A. Chipman, Lloyd W. Hillman

    Previous work describing a resilient method for measuring oxyhemoglobin saturation using the blue-green spectral shift was performed using cell free hemoglobin solutions. Hemoglobin solution and whole blood sample spectra measured under similar conditions in a spectrophotometer are used here to begin evaluating the impact of cellular scattering on this method. The blue-green spectral shift with changing oxyhemoglobin saturation was preserved in these blood samples and the blue-green spectral shift was relatively unaffected by physiological changes in blood pH (6.6, 7.1, and 7.4), path length through blood (100 and 200μm), and blood hematocrit (19 to 48%). The packaging of hemoglobin in red blood cells leads to a decreased apparent path length through hemoglobin, and an overall decrease in scattering loss with increasing wavelength from 450 to 850nm. The negative slope of the scattering loss in the 476 to 516-nm range leads to a +3.0nm shift in the oxyhemoglobin saturation calibration line when the blue-green spectral minimum in these blood samples was compared to cell free hemoglobin. Further research is needed to fully evaluate the blue green spectral shift method in cellular systems including in vivo testing.


  • Oxyhemoglobin saturation measurements by green spectral shift

    by Kurt R. Denninghoff, Russell A. Chipman, Lloyd W. Hillman

    From an analysis of new hemoglobin solution transmission spectra at various oxygen saturations (SO2), path lengths, and pH, we find the determination of SO2 by using the classical oximetry technique to be poorly calibrated. We used this data set to develop a proposed method for SO2 determination based on the spectral shift of the hemoglobin transmission minimum between 475 and 510 nm. The method does not require accurate knowledge of hemoglobin extinction coefficients and is linear in relation to SO2 despite changes in path length, pH, or hemoglobin concentration.