MMMary-Ann Mycek

Mary-Ann Mycek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mary-Ann Mycek has a total of 96 co-authors. Here are the top co-authors by number of shared publications:

  • Ching-Wei Chang

    University of Michigan

    9 shared publications
  • Malavika Chandra

    From the *Department of Biomedical Engineering, †Department of Internal Medicine, ‡Comprehensive Cancer Center §Department of Biostatistics, ∥Department of Pathology, and ¶Department of Surgery, University of Michigan, Ann Arbor, MI

    8 shared publications
  • Barbara McKenna

    Department of Pathology, University of Michigan, Ann Arbor, MI 48109-0602, USA

    7 shared publications
  • Diane Simeone

    Department of Surgery, University of Michigan, Ann Arbor, MI 48109-5331, USA

    7 shared publications
  • James Scheiman

    Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109-0362, USA ; Comprehensive Cancer Center, University of Michigan, Ann Arbor, MI 48109-0944, USA

    7 shared publications
  • Robert H. Wilson

    From the *Department of Biomedical Engineering, †Department of Internal Medicine, ‡Comprehensive Cancer Center §Department of Biostatistics, ∥Department of Pathology, and ¶Department of Surgery, University of Michigan, Ann Arbor, MI

    7 shared publications

Latest Publications

  • Open Access

    Efficient computation of the steady-state and time-domain solutions of the photon diffusion equation in layered turbid media

    by Michael Helton, Samantha Zerafa, Karthik Vishwanath, Mary-Ann Mycek

    Accurate and efficient forward models of photon migration in heterogeneous geometries are important for many applications of light in medicine because many biological tissues exhibit a layered structure of independent optical properties and thickness. However, closed form analytical solutions are not readily available for layered tissue-models, and often are modeled using computationally expensive numerical techniques or theoretical approximations that limit accuracy and real-time analysis. Here, we develop an open-source accurate, efficient, and stable numerical routine to solve the diffusion equation in the steady-state and time-domain for a layered cylinder tissue model with an arbitrary number of layers and specified thickness and optical coefficients. We show that the steady-state ( $$< 0.1$$ < 0.1 ms) and time-domain ( $$< 0.5$$ < 0.5 ms) fluence (for an 8-layer medium) can be calculated with absolute numerical errors approaching machine precision. The numerical implementation increased computation speed by 3 to 4 orders of magnitude compared to previously reported theoretical solutions in layered media. We verify our solutions asymptotically to homogeneous tissue geometries using closed form analytical solutions to assess convergence and numerical accuracy. Approximate solutions to compute the reflected intensity are presented which can decrease the computation time by an additional 2–3 orders of magnitude. We also compare our solutions for 2, 3, and 5 layered media to gold-standard Monte Carlo simulations in layered tissue models of high interest in biomedical optics (e.g. skin/fat/muscle and brain). The presented routine could enable more robust real-time data analysis tools in heterogeneous tissues that are important in many clinical applications such as functional brain imaging and diffuse optical spectroscopy.


  • Open Access

    Light diffusion in layered media: A numerical study in the spatial and time-domains

    by Michael Helton, Samantha Zerafa, Karthik Vishwanath, Mary-Ann Mycek

    Accurate and efficient forward models of photon migration in heterogeneous geometries are important for many applications of light in medicine because many biological tissues exhibit a layered structure, with each layer having independent optical properties and thickness. Unfortunately, closed form analytical solutions are not readily available for layered tissue-models, and often are modeled using computationally expensive numerical techniques or theoretical approximations that limit accuracy and real-time analysis. Here, we develop an open-source accurate, efficient, and stable numerical routine to solve the diffusion equation in the steady-state and time-domain for a layered cylinder tissue model with an arbitrary number of layers and specified thickness and optical coefficients. We show that the steady-state (< 0.1 ms) and time-domain (< 0.5 ms) fluence (for an 8-layer medium) can be calculated with absolute numerical errors approaching machine precision. The numerical implementation increased computation speed by 3 to 4 orders of magnitude compared to previously reported theoretical solutions in layered media. We verify our solutions asymptotically to homogeneous tissue geometries using closed form analytical solutions to assess convergence and numerical accuracy. Approximate solutions to compute the reflected intensity are presented which can decrease the computation time by an additional 2-3 orders of magnitude. We also compare our solutions for 2, 3, and 5 layered media to gold-standard Monte Carlo simulations in layered tissue models of high interest in biomedical optics (e.g. skin/fat/muscle and brain). The presented routine could enable more robust real-time data analysis tools in heterogeneous tissues that are important in many clinical applications such as functional brain imaging and diffuse optical spectroscopy.

  • Noninvasive Optical Assessment of Implanted Tissue-Engineered Construct Success In Situ

    by William R. Lloyd, Seung Yup Lee, Sakib F. Elahi, Leng-Chun Chen, Shiuhyang Kuo, Hyungjin Myra Kim, Cynthia Marcelo, Stephen E. Feinberg, Mary-Ann Mycek

    Quantitative diffuse reflectance spectroscopy (DRS) was developed for label-free, noninvasive, and real-time assessment of implanted tissue-engineered devices manufactured from primary human oral keratinocytes (six batches in two 5-patient cohorts). Constructs were implanted in a murine model for 1 and 3 weeks. DRS evaluated construct success in situ using optical absorption (hemoglobin concentration and oxygenation, attributed to revascularization) and optical scattering (attributed to cellular density and layer thickness). Destructive pre- and postimplantation histology distinguished experimental control from stressed constructs, whereas noninvasive preimplantation measures of keratinocyte glucose consumption and residual glucose in spent culture media did not. In constructs implanted for 1 week, DRS distinguished control due to stressed and compromised from healthy constructs. In constructs implanted for 3 weeks, DRS identified constructs with higher postimplantation success. These results suggest that quantitative DRS is a promising, clinically compatible technology for rapid, noninvasive, and localized tissue assessment to characterize tissue-engineered construct success in vivo . Impact statement: Despite the recent advance in tissue engineering and regenerative medicine, there is still a lack of nondestructive tools to longitudinally monitor the implanted tissue-engineered devices. In this study, we demonstrate the potential of quantitative diffuse reflectance spectroscopy as a clinically viable technique for noninvasive, label-free, and rapid characterization of graft success in situ .


  • Open Access

    Needle-compatible miniaturized optoelectronic sensor for pancreatic cancer detection

    by Seung Yup Lee, Julia M. Pakela, Kyounghwan Na, Jiaqi Shi, Barbara J. McKenna, Diane M. Simeone, Euisik Yoon, James M. Scheiman, Mary-Ann Mycek

    Needle-compatible miniaturized optoelectronic sensor may help pancreatic cancer diagnosis.


  • Optical Metric Assessed Engineered Tissues Over a Range of Viability States

    by Leng-Chun Chen, Shiuhyang Kuo, William R. Lloyd, Hyungjin Myra Kim, Cynthia L. Marcelo, Stephen E. Feinberg, Mary-Ann Mycek

    Many conventional methods to assess engineered tissue morphology and viability are destructive techniques with limited utility for tissue constructs intended for implantation in patients. Sterile label-free optical molecular imaging methods analyzed tissue endogenous fluorophores without staining, noninvasively and quantitatively assessing engineered tissue, in lieu of destructive assessment methods. The objective of this study is to further investigate label-free optical metrics and their correlation with destructive methods. Tissue-engineered constructs ( n = 33 constructs) fabricated with primary human oral keratinocytes ( n = 10 patients) under control, thermal stress, and rapamycin treatment manufacturing conditions exhibited a range of tissue viability states, as evaluated by quantitative histology scoring, WST-1 assay, Ki-67 immunostaining imaging, and label-free optical molecular imaging methods. Both histology sections of fixed tissues and cross-sectioned label-free optical images of living tissues provided quantitative spatially selective information on local tissue morphology, but optical methods noninvasively characterized both local tissue morphology and cellular viability at the same living tissue site. Furthermore, optical metrics noninvasively assessed living tissue viability with a statistical significance consistent with the destructive tissue assays WST-1 and histology. Over the range of cell viability states created experimentally, optical metrics noninvasively and quantitatively characterized living tissue viability and correlated with the destructive WST-1 tissue assay. By providing, under sterile conditions, noninvasive metrics that were comparable with conventional destructive tissue assays, label-free optical molecular imaging has the potential to monitor and assess engineered tissue construct viability before surgical implantation.


  • Hybrid Monte Carlo simulation with ray tracing for fluorescence measurements in turbid media

    by Seung Yup Lee, Mary-Ann Mycek

    We present a hybrid Monte Carlo simulation method with geometrical ray tracing (hMC-GRT) to model fluorescence excitation and detection in turbid media by optical imaging or spectroscopy systems employing a variety of optical components. hMC-GRT computational verification was achieved via reflectance and fluorescence simulations on epithelial tissue models in comparison with a standard Monte Carlo code. The mean difference between the two simulations was less than 5%. hMC-GRT experimental verification employed depth-sensitive steady-state fluorescence measurements using an aspherical lens on two-layered tissue phantoms. hMC-GRT predictions agreed well with experimental results, achieving less than 3.5% error for measurements at the phantom surface. Verification results demonstrate that the hMC-GRT simulation has the potential to become a useful computational toolbox for designing tissue fluorescence imaging and spectroscopy systems. In addition, the hMC-GRT approach enables a wide variety of applications for computational modeling of fluorescence in turbid media. The source codes are available at https://github.com/ubioptronics/hMC-GRT.


  • Noninvasive Optical Assessment of Implanted Engineered Tissues Correlates with Cytokine Secretion

    by Sakib F. Elahi, Seung Yup Lee, William R. Lloyd, Leng-Chun Chen, Shiuhyang Kuo, Ying Zhou, Hyungjin Myra Kim, Robert Kennedy, Cynthia Marcelo, Stephen E. Feinberg, et al.

    Fluorescence lifetime sensing has been shown to noninvasively characterize the pre-implantation health and viability of engineered tissue constructs. However, current practices to monitor post-implantation construct integration are either qualitative (visual assessment) or destructive (tissue histology). We employed label-free fluorescence lifetime spectroscopy for quantitative, noninvasive optical assessment of engineered tissue constructs that were implanted in a murine model. The portable system was designed to be suitable for intravital measurements and included a handheld probe to precisely and rapidly acquire data at multiple sites per construct. Our model tissue constructs were manufactured from primary human cells to simulate patient variability based on a standard protocol, and half of the manufactured constructs were stressed to create a range of health states. Secreted amounts of three cytokines that relate to cellular viability were measured in vitro to assess pre-implantation construct health: interleukin-8 (IL-8), human β-defensin 1 (hBD-1), and vascular endothelial growth factor (VEGF). Pre-implantation cytokine secretion ranged from 1.5-33.5 pg/ml for IL-8, 3.4-195.0 pg/ml for hBD-1, and 0.1-154.3 pg/ml for VEGF. In vivo optical sensing assessed constructs at one-week and three-weeks post-implantation. We found that at one-week post-implantation, in vivo optical parameters correlated with in vitro pre-implantation secretion levels of all three cytokines (p < 0.05). This correlation was not observed in optical measurements at three-weeks post-implantation when histology showed that the constructs had re-epithelialized, independent of pre-implantation health state, supporting the lack of a correlation. These results suggest that clinical optical diagnostic tools based on label-free fluorescence lifetime sensing of endogenous tissue fluorophores could noninvasively monitor post-implantation integration of engineered tissues.


  • Assessment of post-implantation integration of engineered tissues using fluorescence lifetime spectroscopy

    by Sakib F. Elahi, Seung Yup Lee, William R. Lloyd, Shiuhyang Kuo, Ying Zhou, Hyungjin M. Kim, Robert Kennedy, Cynthia Marcelo, Stephen E. Feinberg, Mary-Ann Mycek, et al.

    Clinical translation of engineered tissue constructs requires noninvasive methods to assess construct health and viability after implantation in patients. However, current practices to monitor post-implantation construct integration are either qualitative (visual assessment) or destructive (tissue histology). As label-free fluorescence lifetime sensing can noninvasively characterize pre-implantation construct viability, we employed a handheld fluorescence lifetime spectroscopy probe to quantitatively and noninvasively assess tissue constructs that were implanted in a murine model. We designed the system to be suitable for intravital measurements: portability, localization with precise maneuverability, and rapid data acquisition. Our model tissue constructs were manufactured from primary human cells to simulate patient variability and were stressed to create a range of health states. Secreted amounts of three cytokines that relate to cellular viability were measured in vitro to assess pre-implantation construct health. In vivo optical sensing assessed tissue integration of constructs at one-week and three-weeks post-implantation. At one-week post-implantation, optical parameters correlated with in vitro pre-implantation secretion levels of all three cytokines (p < 0.05). This relationship was no longer seen at three-weeks post-implantation, suggesting comparable tissue integration independent of preimplantation health. Histology confirmed re-epithelialization of these constructs independent of pre-implantation health state, supporting the lack of a correlation. These results suggest that clinical optical diagnostic tools based on label-free fluorescence lifetime sensing of endogenous tissue fluorophores could noninvasively monitor post-implantation integration of engineered tissues.

  • Open Access

    Compact dual-mode diffuse optical system for blood perfusion monitoring in a porcine model of microvascular tissue flaps

    by Seung Yup Lee, Julia M. Pakela, Michael C. Helton, Karthik Vishwanath, Yooree G. Chung, Noah J. Kolodziejski, Christopher J. Stapels, Daniel R. McAdams, Daniel E. Fernandez, James F. Christian, et al.

    In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities—diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy—to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model ( n = 8 ). With a controllable arterial blood flow supply, occlusion studies ( n = 4 ) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure ( n = 4 ). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.


  • Quantitative, Label-Free Evaluation of Tissue-Engineered Skeletal Muscle Through Multiphoton Microscopy

    by Brian C. Syverud, Mary-Ann Mycek, Lisa Marie Larkin

    The lack of tools for assessing engineered tissue viability and function in a non-invasive manner is a major regulatory and translational challenge facing tissue engineers. Label-free, nonlinear optical molecular imaging (OMI) has utilized endogenous nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) fluorescence to indicate metabolic activity. Similarly, second harmonic generation (SHG) signals from myosin and collagen can measure overall muscle structural integrity and function. The purpose of this study was to demonstrate these OMI techniques for the first time in engineered skeletal muscle and to develop a novel method for evaluating our engineered skeletal muscle units (SMUs) prior to implantation. Three experimental groups were studied: Control, Steroid Supplemented, and Metabolically Stressed SMUs. Following imaging and analysis in ImageJ, a redox ratio metric was calculated to indicate metabolic activity, and a structure ratio metric was calculated to reflect structural composition. In addition, function was evaluated as tetanic force production in response to electrical stimulation. In living tissues, the redox ratios successfully distinguished control and metabolically-stressed SMUs in both monolayer and 3D form. OMI of myosin and collagen SHG similarly differentiated control SMUs from the steroid supplemented group. With respect to function, steroid supplementation significantly increased active force generation. When comparing functional and OMI measures, a significant correlation was present between overall myosin density and active force generation. This work demonstrates the potential for using label-free OMI to evaluate tissue-engineered skeletal muscle constructs. The positive correlation between structural OMI measures and force production suggests OMI could potentially serve as an accurate predictor of functional behaviors, such as integration and tissue regeneration, following implantation. This non-invasive OMI methodology, demonstrated for the first time in engineered skeletal muscle, could prove invaluable for assessing our tissue engineering technology and confirming release criteria for validation.