JLJames Lamb

James Lamb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James Lamb has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MR-Guided Radiation Therapy for Prostate and Pancreas Cancer Treatment: A Dosimetric Study Across Two Major MR-Linac Platforms

    by Huiming Dong, Jonathan Pham, Michael V. Lauria, Caiden Atienza, Brett Sloman, Paul Barry, Jennifer Davis, Michael Saracen, Amar Kishan, Ann Raldow, et al.

    Background/Objectives: MR-guided radiation therapy (MRgRT) has rapidly evolved into an important treatment modality, with the Elekta Unity and ViewRay MRIdian systems being two major MR-linac platforms. Despite the shared concept of MRgRT, the two platforms elected different system designs that could potentially impact the dosimetric characteristics and quality of a treatment. In this study, we aim to perform a comparative dosimetric investigation between these two MR-linac systems in prostate and pancreas cancers. Methods: Dosimetric characteristics were evaluated by retrospectively re-creating 20 clinical prostate and pancreas cases originally treated on MRIdian using the Unity system, adhering to MIRAGE and SMART clinical trial constraints. Treatment plans were re-created with matching planning images, structures, beam geometry, and dose parameters. To ensure comparison consistency, all Unity treatment plans were normalized to match the target coverage of the MRIdian counterparts, and the organ-at-risk (OAR) dose was investigated. Results: Most OARs’ dose-volume metrics showed no statistically significant differences. For prostate patients, Unity demonstrated lower rectum V36Gy (p = 0.0095), V38Gy (p = 0.0043), V40Gy (p = 0.0469), and lower left (p = 0.0137) and right femur V20Gy (p = 0.0020). For pancreas patients, Unity plans had a lower mean liver dose (p = 0.0371). All Unity plans had a Gamma passing rate > 90%, confirming the clinical deliverability. Mean delivery times were 12.78 ± 1.68 and 13.53 ± 1.88 min for MRIdian and Unity prostate plans, respectively, and 14.58 ± 2.78 and 17.40 ± 3.77 min for MRIdian and Unity pancreas plans, respectively. Conclusions: Overall, comparable treatment quality and delivery times were observed between the two platforms.


  • Open Access

    MRI-Guided Radiation Therapy for Prostate Cancer: The Next Frontier in Ultrahypofractionation

    by Cecil M. Benitez, Michael L. Steinberg, Minsong Cao, X. Sharon Qi, James M. Lamb, Amar U. Kishan, Luca F. Valle

    Technological advances in MRI-guided radiation therapy (MRIgRT) have improved real-time visualization of the prostate and its surrounding structures over CT-guided radiation therapy. Seminal studies have demonstrated safe dose escalation achieved through ultrahypofractionation with MRIgRT due to planning target volume (PTV) margin reduction and treatment gating. On-table adaptation with MRI-based technologies can also incorporate real-time changes in target shape and volume and can reduce high doses of radiation to sensitive surrounding structures that may move into the treatment field. Ongoing clinical trials seek to refine ultrahypofractionated radiotherapy treatments for prostate cancer using MRIgRT. Though these studies have the potential to demonstrate improved biochemical control and reduced side effects, limitations concerning patient treatment times and operational workflows may preclude wide adoption of this technology outside of centers of excellence. In this review, we discuss the advantages and limitations of MRIgRT for prostate cancer, as well as clinical trials testing the efficacy and toxicity of ultrafractionation in patients with localized or post-prostatectomy recurrent prostate cancer.


  • Proton beam therapy for tumors of the upper abdomen

    by Ann Raldow, James Lamb, Theodore Hong

    Proton radiotherapy has clear dosimetric advantages over photon radiotherapy. In contrast to photons, which are absorbed exponentially, protons have a finite range dependent on the initial proton energy. Protons therefore do not deposit dose beyond the tumor, resulting in great conformality, and offers the promise of dose escalation to increase tumor control while minimizing toxicity. In this review, we discuss the rationale for using proton radiotherapy in the treatment of upper abdominal tumors—hepatocellular carcinomas, cholangiocarcinomas and pancreatic cancers. We also review the clinical outcomes and technical challenges of using proton radiotherapy for the treatment of these malignancies. Finally, we discuss the ongoing clinical trials implementing proton radiotherapy for the treatment of primary liver and pancreatic tumors.


  • Retrospective evaluation of decision-making for pancreatic stereotactic MR-guided adaptive radiotherapy

    by Marguerite Tyran, Naomi Jiang, Minsong Cao, Ann Raldow, James M. Lamb, Daniel Low, Elaine Luterstein, Michael L. Steinberg, Percy Lee


  • Open Access

    Magnetic Resonance Imaging Guidance Mitigates the Effects of Intrafraction Prostate Motion During Stereotactic Body Radiotherapy for Prostate Cancer

    by John V. Hegde, Minsong Cao, Victoria Y. Yu, Amar U. Kishan, Narek Shaverdian, James Lamb, Michael L. Steinberg

    The accurate delivery of stereotactic body radiotherapy (SBRT) for definitive prostate cancer treatment is aided by intrafraction image guidance. The common methods for intrafraction imaging require the invasive placement of fiducial markers or electromagnetic transponders. Recently, a magnetic resonance imaging (MRI)-guided tri-cobalt-60 head radiotherapy system has become available for treatment, which can utilize real-time cine MRI to non-invasively track prostate motion. We report on a clinical vignette using this technique to deliver SBRT for the definitive treatment of intermediate-risk prostate cancer. The incorporation of an MRI-guided radiotherapy system and the implementation of real-time adaptive dose delivery accounting for intrafraction anatomic motion may improve outcomes using this technique.


  • Open Access

    Magnetic Resonance-guided Inter-fraction Monitoring Opens Doors to Delivering Safer Reirradiation: An Illustrative Case Report and Discussion

    by Rebecca Levin-Epstein, Minsong Cao, Percy Lee, Michael L. Steinberg, James Lamb, Ann C. Raldow

    Locoregional recurrence in the pelvis after definitive treatment for rectal cancer can lead to significant morbidity. Furthermore, the toxicity associated with reirradiation may also negatively impact the quality of life and even survival. Here we present the case of a 39-yearold male with locoregionally recurrent rectal cancer in a left pelvic sidewall lymph node, treated with stereotactic magnetic resonance (MR)-guided ablative radiotherapy after previously receiving long-course chemoradiation that had already exceeded ideal bowel dose constraints. We discuss the distinct advantages of MR-guidance in the setting of pelvic reirradiation, particularly with regard to inter- and intra-fraction visualization of the target and neighboring bowel anatomy. In this context, MR-guidance may allow radiation oncologists to increase target precision and accuracy, while simultaneously decreasing toxicity to neighboring tissues.


  • Open Access

    Stereotactic MRI-guided Adaptive Radiation Therapy (SMART) for Locally Advanced Pancreatic Cancer: A Promising Approach

    by Elaine Luterstein, Minsong Cao, James Lamb, Ann C. Raldow, Daniel A Low, Michael L. Steinberg, Percy Lee

    Locally advanced pancreatic cancer (LAPC) is characterized by poor prognosis and low response durability with standard-of-care chemotherapy or chemoradiotherapy treatment. Stereotactic body radiation therapy (SBRT), which has a shorter treatment course than conventionally fractionated radiotherapy and allows for better integration with systemic therapy, may confer a survival benefit but is limited by gastrointestinal toxicity. Stereotactic MRI-guided adaptive radiation therapy (SMART) has recently gained attention for its potential to increase treatment precision and thus minimize this toxicity through continuous real-time soft-tissue imaging during radiotherapy. The case presented here illustrates the promising outcome of a 69-year-old male patient with LAPC treated with SMART with daily adaptive planning and respiratory-gated technique.


  • Open Access

    Stereotactic Magnetic Resonance-guided Online Adaptive Radiotherapy for Oligometastatic Breast Cancer: A Case Report

    by Marguerite Tyran, Minsong Cao, Ann C. Raldow, Audrey Dang, James Lamb, Daniel A Low, Michael L. Steinberg, Percy Lee

    We present a case of durable local control achieved in a patient treated with stereotactic magnetic resonance-guided adaptive radiation therapy (SMART) for an abdominal lymph node in the setting of oligometastatic breast cancer. A 50-year-old woman with a history of triple positive metastatic invasive ductal carcinoma of the left breast, stage IV (T3N2M1), underwent neoadjuvant chemotherapy, mastectomy, adjuvant radiotherapy and maintenance hormonal treatment with HER2 targeted therapies. At 20 months after definitive treatment of her primary, imaging showed an isolated progressive enlargement of lymph nodes between hepatic segment V/IVB and the neck of the pancreas. Radiofrequency ablation was considered, however, this approach was decided not to be optimal due to the proximity to stomach, and pancreatic duct. The patient was treated with SMART for 40 Gray in 5 fractions. Two and a half years later, the patient remains without evidence of disease progression. She experienced Grade 2 acute and late toxicity that was successfully managed with medications. This experience shows that SMART is a feasible and effective treatment to control the abdominal oligometastatic disease for breast cancer.


  • Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT

    by David H Thomas, Anand Santhanam, Amar U Kishan, Minsong Cao, James Lamb, Yugang Min, Dylan O'COnnell, Yingli Yang, Nzhde Agazaryan, Percy Lee, et al.

    Objective: To evaluate variations in intra- and interfractional tumour motion, and the effect on internal target volume (ITV) contour accuracy, using deformable image registration of real-time two-dimensional-sagittal cine-mode MRI acquired during lung stereotactic body radiation therapy (SBRT) treatments. Methods: Five lung tumour patients underwent free-breathing SBRT treatments on the ViewRay system, with dose prescribed to a planning target volume (defined as a 3–6 mm expansion of the 4DCT-ITV). Sagittal slice cine-MR images (3.5 × 3.5 mm2 pixels) were acquired through the centre of the tumour at 4 frames per second throughout the treatments (3–4 fractions of 21–32 min). Tumour gross tumour volumes (GTVs) were contoured on the first frame of the MR cine and tracked for the first 20 min of each treatment using offline optical-flow based deformable registration implemented on a GPU cluster. A ground truth ITV (MR-ITV20 min) was formed by taking the union of tracked GTV contours. Pseudo-ITVs were generated from unions of the GTV contours tracked over 10 s segments of image data (MR-ITV10 s). Results: Differences were observed in the magnitude of median tumour displacement between days of treatments. MR-ITV10 s areas were as small as 46% of the MR-ITV20 min. Conclusion: An ITV offers a “snapshot” of breathing motion for the brief period of time the tumour is imaged on a specific day. Real-time MRI over prolonged periods of time and over multiple treatment fractions shows that ITV size varies. Further work is required to investigate the dosimetric effect of these results. Advances in knowledge: Five lung tumour patients underwent free-breathing MRI-guided SBRT treatments, and their tumours tracked using deformable registration of cine-mode MRI. The results indicate that variability of both intra- and interfractional breathing amplitude should be taken into account during planning of lung radiotherapy.