Daniel A. Low
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel A. Low has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- James Lamb
Department of Radiation Oncology, University of California, Los Angeles, CA 90095, USA
9 shared publications - Percy Lee
Department of Radiation Oncology, City of Hope National Medical Center, Los Angeles, CA
9 shared publications - Minsong Cao
Department of Radiation Oncology, University of California, Los Angeles , Los Angeles, CA, 90095
8 shared publications - Michael L. Steinberg
University of California Los Angeles
7 shared publications - David H. Thomas
Radiation Oncology, University of Colorado, 1665 Aurora Ct, Suite 1032, Denver, Colorado, 850045, UNITED STATES
6 shared publications - Ke Sheng
Radiation Oncology, University of California San Francisco, 1600 Divisadero St, San Francisco, California, 94143, UNITED STATES
5 shared publications
Latest Publications
- Open Access
A Retrospective Analysis of the First Clinical 5DCT Workflow
Background/Objectives: 5DCT was first proposed in 2005 as a motion-compensated CT simulation approach for radiotherapy treatment planning to avoid sorting artifacts that arise in 4DCT when patients breathe irregularly. Since March 2019, 5DCT has been clinically implemented for routine use at our institution to leverage this technological advantage. The clinical workflow includes a quality assurance report that describes the output of primary workflow steps. This study reports on the challenges and quality of the clinical 5DCT workflow using these quality assurance reports. Methods: We evaluated all thoracic 5DCT simulation datasets consecutively acquired at our institution between March 2019 and December 2022 for thoracic radiotherapy treatment planning. The 5DCT datasets utilized motion models constructed from 25 fast-helical free-breathing computed tomography (FHFBCTs) with simultaneous respiratory bellows signal monitoring to reconstruct individual, user-specified breathing-phase images (termed 5DCT phase images) for internal target volume contouring. Each 5DCT dataset was accompanied by a structured quality assurance report composed of qualitative and quantitative measures of the breathing pattern, image quality, DIR quality, model fitting accuracy, and a validation process by which the original FHFBCT scans were regenerated with the 5DCT model. Measures of breathing irregularity, image quality, and DIR quality were retrospectively categorized on a grading scale from 1 (regular breathing and accurate registration/modeling) to 4 (irregular breathing and inaccurate registration/modeling). The validation process was graded according to the same scale, and this grade was termed the suitability-for-treatment-planning (STP) grade. We correlated the graded variables to the STP grade. In addition to the quality assurance reports, we reviewed the contour sessions to determine how often 5DCT phase images were used for treatment planning and delivery. Results: There were 169 5DCT simulation datasets available from 156 patients for analysis. The STP was moderately correlated with breathing irregularity, image quality, and DIR quality (Spearman coefficients: 0.26, 0.30, and 0.50, respectively). Multiple linear regression analysis demonstrated that STP was correlated with regular breathing patterns (p = 0.008), image quality (p < 0.001), and better DIR quality (p < 0.001). 5DCT datasets were used for treatment planning in 82% of cases, while in 12% of cases, a backup image process was used. In total, 6% of image datasets were not used for treatment planning due to factors unrelated to the 5DCT workflow quality. Conclusions: The strongest association with STP was with DIR quality grades, as indicated by both Spearman and multiple linear regression analysis, implying that improvements to DIR accuracy and evaluation may be the best route for further improvement to 5DCT. The high rate of 5DCT phase image use for treatment planning showed that the workflow was reliable, and this has encouraged us to continue to develop and improve the workflow steps.
Open AccessA Retrospective Analysis of the First Clinical 5DCT Workflow
Background/Objectives: 5DCT was first proposed in 2005 as a motion-compensated CT simulation approach for radiotherapy treatment planning to avoid sorting artifacts that arise in 4DCT when patients breathe irregularly. Since March 2019, 5DCT has been clinically implemented for routine use at our institution to leverage this technological advantage. The clinical workflow includes a quality assurance report that describes the output of primary workflow steps. This study reports on the challenges and quality of the clinical 5DCT workflow using these quality assurance reports. Methods: We evaluated all thoracic 5DCT simulation datasets consecutively acquired at our institution between March 2019 and December 2022 for thoracic radiotherapy treatment planning. The 5DCT datasets utilized motion models constructed from 25 fast-helical free-breathing computed tomography (FHFBCTs) with simultaneous respiratory bellows signal monitoring to reconstruct individual, user-specified breathing-phase images (termed 5DCT phase images) for internal target volume contouring. Each 5DCT dataset was accompanied by a structured quality assurance report composed of qualitative and quantitative measures of the breathing pattern, image quality, DIR quality, model fitting accuracy, and a validation process by which the original FHFBCT scans were regenerated with the 5DCT model. Measures of breathing irregularity, image quality, and DIR quality were retrospectively categorized on a grading scale from 1 (regular breathing and accurate registration/modeling) to 4 (irregular breathing and inaccurate registration/modeling). The validation process was graded according to the same scale, and this grade was termed the suitability-for-treatment-planning (STP) grade. We correlated the graded variables to the STP grade. In addition to the quality assurance reports, we reviewed the contour sessions to determine how often 5DCT phase images were used for treatment planning and delivery. Results: There were 169 5DCT simulation datasets available from 156 patients for analysis. The STP was moderately correlated with breathing irregularity, image quality, and DIR quality (Spearman coefficients: 0.26, 0.30, and 0.50, respectively). Multiple linear regression analysis demonstrated that STP was correlated with regular breathing patterns (p = 0.008), image quality (p < 0.001), and better DIR quality (p < 0.001). 5DCT datasets were used for treatment planning in 82% of cases, while in 12% of cases, a backup image process was used. In total, 6% of image datasets were not used for treatment planning due to factors unrelated to the 5DCT workflow quality. Conclusions: The strongest association with STP was with DIR quality grades, as indicated by both Spearman and multiple linear regression analysis, implying that improvements to DIR accuracy and evaluation may be the best route for further improvement to 5DCT. The high rate of 5DCT phase image use for treatment planning showed that the workflow was reliable, and this has encouraged us to continue to develop and improve the workflow steps.
- 15 December 2023
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 34 (1) , 1-3
Magnetic Resonance Imaging Guided Radiation Therapy: Overview
- 15 December 2023
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 34 (1) , 1-3
Magnetic Resonance Imaging Guided Radiation Therapy: Overview
- 15 December 2023
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 34 (1) , 14-22
MRI-Guided Radiation Therapy Systems
- 15 December 2023
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 34 (1) , 14-22
MRI-Guided Radiation Therapy Systems
- Open Access
Predicting Overall Survival for Patients with Malignant Mesothelioma Following Radiotherapy via Interpretable Machine Learning
Purpose/Objectives: Malignant pleural mesothelioma (MPM) is a rare but aggressive cancer arising from the cells of the thoracic pleura with a poor prognosis. We aimed to develop a model, via interpretable machine learning (ML) methods, predicting overall survival for MPM following radiotherapy based on dosimetric metrics as well as patient characteristics. Materials/Methods: Sixty MPM (37 right, 23 left) patients treated on a Tomotherapy unit between 2013 and 2018 were retrospectively analyzed. All patients received 45 Gy (25 fractions). The multivariable Cox regression (Cox PH) model and Survival Support Vector Machine (sSVM) were applied to build predictive models of overall survival (OS) based on clinical, dosimetric, and combined variables. Results: Significant differences in dosimetric endpoints for critical structures, i.e., the lung, heart, liver, kidney, and stomach, were observed according to target laterality. The OS was found to be insignificantly different (p = 0.18) between MPM patients who tested left- and right-sided, with 1-year OS of 77.3% and 75.0%, respectively. With Cox PH regression, considering dosimetric variables for right-sided patients alone, an increase in PTV_Min, Total_Lung_PTV_Mean, Contra_Lung_Volume, Contra_Lung_V20, Esophagus_Mean, and Heart_Volume had a greater hazard to all-cause death, while an increase in Total_Lung_PTV_V20, Contra_Lung_V5, and Esophagus_Max had a lower hazard to all-cause death. Considering clinical variables alone, males and increases in N stage had greater hazard to all-cause death; considering both clinical and dosimetric variables, increases in N stage, PTV_Mean, PTV_Min, and esophagus_Mean had greater hazard to all-cause death, while increases in T stage and Heart_V30 had lower hazard to all-cause-death. In terms of C-index, the Cox PH model and sSVM performed similarly and fairly well when considering clinical and dosimetric variables independently or jointly. Conclusions: Clinical and dosimetric variables may predict the overall survival of mesothelioma patients, which could guide personalized treatment planning towards a better treatment response. The identified predictors and their impact on survival offered additional value for translational application in clinical practice.
Open AccessPredicting Overall Survival for Patients with Malignant Mesothelioma Following Radiotherapy via Interpretable Machine Learning
Purpose/Objectives: Malignant pleural mesothelioma (MPM) is a rare but aggressive cancer arising from the cells of the thoracic pleura with a poor prognosis. We aimed to develop a model, via interpretable machine learning (ML) methods, predicting overall survival for MPM following radiotherapy based on dosimetric metrics as well as patient characteristics. Materials/Methods: Sixty MPM (37 right, 23 left) patients treated on a Tomotherapy unit between 2013 and 2018 were retrospectively analyzed. All patients received 45 Gy (25 fractions). The multivariable Cox regression (Cox PH) model and Survival Support Vector Machine (sSVM) were applied to build predictive models of overall survival (OS) based on clinical, dosimetric, and combined variables. Results: Significant differences in dosimetric endpoints for critical structures, i.e., the lung, heart, liver, kidney, and stomach, were observed according to target laterality. The OS was found to be insignificantly different (p = 0.18) between MPM patients who tested left- and right-sided, with 1-year OS of 77.3% and 75.0%, respectively. With Cox PH regression, considering dosimetric variables for right-sided patients alone, an increase in PTV_Min, Total_Lung_PTV_Mean, Contra_Lung_Volume, Contra_Lung_V20, Esophagus_Mean, and Heart_Volume had a greater hazard to all-cause death, while an increase in Total_Lung_PTV_V20, Contra_Lung_V5, and Esophagus_Max had a lower hazard to all-cause death. Considering clinical variables alone, males and increases in N stage had greater hazard to all-cause death; considering both clinical and dosimetric variables, increases in N stage, PTV_Mean, PTV_Min, and esophagus_Mean had greater hazard to all-cause death, while increases in T stage and Heart_V30 had lower hazard to all-cause-death. In terms of C-index, the Cox PH model and sSVM performed similarly and fairly well when considering clinical and dosimetric variables independently or jointly. Conclusions: Clinical and dosimetric variables may predict the overall survival of mesothelioma patients, which could guide personalized treatment planning towards a better treatment response. The identified predictors and their impact on survival offered additional value for translational application in clinical practice.
- 19 August 2021
- Published by Wiley in Medical Physics
- Vol. 48 (10) , 6094-6105
Ventilation measurements using fast‐helical free‐breathing computed tomography
Purpose: To examine the use of multiple fast‐helical free breathing computed tomography (FHFBCT) scans for ventilation measurement.Methods: Ten patients were scanned 25 times in alternating directions using a FHFBCT protocol. Simultaneously, an abdominal pneumatic bellows was used as a real‐time breathing surrogate. Regions‐of‐interest (ROIs) were selected from the upper right lungs of each patient for analysis. The ROIs were first registered using a published registration technique (pTV). A subsequent follow‐up registration employed an objective function with two terms, a ventilation‐adjusted Hounsfield Unit difference and a conservation‐of‐mass term labeled ΔΓ that denoted the difference between the deformation Jacobian and the tissue density ratio. The ventilations were calculated voxel‐by‐voxel as the slope of a first‐order fit of the Jacobian as a function of the breathing amplitude.Results: The ventilations of the 10 patients showed different patterns and magnitudes. The average ventilation calculated from the deformation vector fields (DVFs) of the pTV and secondary registration was nearly identical, but the standard deviation of the voxel‐to‐voxel differences was approximately 0.1. The mean of the 90th percentile values of ΔΓ was reduced from 0.153 to 0.079 between the pTV and secondary registration, implying first that the secondary registration improved the conservation‐of‐mass criterion by almost 50% and that on average the correspondence between the Jacobian and density ratios as demonstrated by ΔΓ was less than 0.1. This improvement occurred in spite of the average of the 90th percentile changes in the DVF magnitudes being only 0.58 mm.Conclusions: This work introduces the use of multiple free‐breathing CT scans for free‐breathing ventilation measurements. The approach has some benefits over the traditional use of 4‐dimensional CT (4DCT) or breath‐hold scans. The benefit over 4DCT is that FHFBCT does not have sorting artifacts. The benefits over breath‐hold scans include the relatively small motion induced by quiet respiration versus deep‐inspiration breath hold and the potential for characterizing dynamic breathing processes that disappear during breath hold.
- 19 August 2021
- Published by Wiley in Medical Physics
- Vol. 48 (10) , 6094-6105
Ventilation measurements using fast‐helical free‐breathing computed tomography
Purpose: To examine the use of multiple fast‐helical free breathing computed tomography (FHFBCT) scans for ventilation measurement.Methods: Ten patients were scanned 25 times in alternating directions using a FHFBCT protocol. Simultaneously, an abdominal pneumatic bellows was used as a real‐time breathing surrogate. Regions‐of‐interest (ROIs) were selected from the upper right lungs of each patient for analysis. The ROIs were first registered using a published registration technique (pTV). A subsequent follow‐up registration employed an objective function with two terms, a ventilation‐adjusted Hounsfield Unit difference and a conservation‐of‐mass term labeled ΔΓ that denoted the difference between the deformation Jacobian and the tissue density ratio. The ventilations were calculated voxel‐by‐voxel as the slope of a first‐order fit of the Jacobian as a function of the breathing amplitude.Results: The ventilations of the 10 patients showed different patterns and magnitudes. The average ventilation calculated from the deformation vector fields (DVFs) of the pTV and secondary registration was nearly identical, but the standard deviation of the voxel‐to‐voxel differences was approximately 0.1. The mean of the 90th percentile values of ΔΓ was reduced from 0.153 to 0.079 between the pTV and secondary registration, implying first that the secondary registration improved the conservation‐of‐mass criterion by almost 50% and that on average the correspondence between the Jacobian and density ratios as demonstrated by ΔΓ was less than 0.1. This improvement occurred in spite of the average of the 90th percentile changes in the DVF magnitudes being only 0.58 mm.Conclusions: This work introduces the use of multiple free‐breathing CT scans for free‐breathing ventilation measurements. The approach has some benefits over the traditional use of 4‐dimensional CT (4DCT) or breath‐hold scans. The benefit over 4DCT is that FHFBCT does not have sorting artifacts. The benefits over breath‐hold scans include the relatively small motion induced by quiet respiration versus deep‐inspiration breath hold and the potential for characterizing dynamic breathing processes that disappear during breath hold.
- Open Access
Evaluation of T2-Weighted MRI for Visualization and Sparing of Urethra with MR-Guided Radiation Therapy (MRgRT) On-Board MRI
Purpose: To evaluate urethral contours from two optimized urethral MRI sequences with an MR-guided radiotherapy system (MRgRT). Methods: Eleven prostate cancer patients were scanned on a MRgRT system using optimized urethral 3D HASTE and 3D TSE. A resident radiation oncologist contoured the prostatic urethra on the patients’ planning CT, diagnostic 3T T2w MRI, and both urethral MRIs. An attending radiation oncologist reviewed/edited the resident’s contours and additionally contoured the prostatic urethra on the clinical planning MRgRT MRI (bSSFP). For each image, the resident radiation oncologist, attending radiation oncologist, and a senior medical physicist qualitatively scored the prostatic urethra visibility. Using MRgRT 3D HASTE-based contouring workflow as baseline, prostatic urethra contours drawn on CT, diagnostic MRI, clinical bSSFP and 3D TSE were evaluated relative to the contour on 3D HASTE using 95th percentile Hausdorff distance (HD95), mean-distance-to-agreement (MDA), and DICE coefficient. Additionally, prostatic urethra contrast-to-noise-ratios (CNR) were calculated for all images. Results: For two out of three observers, the urethra visibility score for 3D HASTE was significantly higher than CT, and clinical bSSFP, but was not significantly different from diagnostic MRI. The mean HD95/MDA/DICE values were 11.35 ± 3.55 mm/5.77 ± 2.69 mm/0.07 ± 0.08 for CT, 7.62 ± 2.75 mm/3.83 ± 1.47 mm/0.12 ± 0.10 for CT + diagnostic MRI, 5.49 ± 2.32 mm/2.18 ± 1.19 mm/0.35 ± 0.19 for 3D TSE, and 6.34 ± 2.89 mm/2.65 ± 1.31 mm/0.21 ± 0.12 for clinical bSSFP. The CNR for 3D HASTE was significantly higher than CT, diagnostic MRI, and clinical bSSFP, but was not significantly different from 3D TSE. Conclusion: The urethra’s visibility scores showed optimized urethral MRgRT 3D HASTE was superior to the other tested methodologies. The prostatic urethra contours demonstrated significant variability from different imaging and workflows. Urethra contouring uncertainty introduced by cross-modality registration and sub-optimal imaging contrast may lead to significant treatment degradation when urethral sparing is implemented to minimize genitourinary toxicity.
Open AccessEvaluation of T2-Weighted MRI for Visualization and Sparing of Urethra with MR-Guided Radiation Therapy (MRgRT) On-Board MRI
Purpose: To evaluate urethral contours from two optimized urethral MRI sequences with an MR-guided radiotherapy system (MRgRT). Methods: Eleven prostate cancer patients were scanned on a MRgRT system using optimized urethral 3D HASTE and 3D TSE. A resident radiation oncologist contoured the prostatic urethra on the patients’ planning CT, diagnostic 3T T2w MRI, and both urethral MRIs. An attending radiation oncologist reviewed/edited the resident’s contours and additionally contoured the prostatic urethra on the clinical planning MRgRT MRI (bSSFP). For each image, the resident radiation oncologist, attending radiation oncologist, and a senior medical physicist qualitatively scored the prostatic urethra visibility. Using MRgRT 3D HASTE-based contouring workflow as baseline, prostatic urethra contours drawn on CT, diagnostic MRI, clinical bSSFP and 3D TSE were evaluated relative to the contour on 3D HASTE using 95th percentile Hausdorff distance (HD95), mean-distance-to-agreement (MDA), and DICE coefficient. Additionally, prostatic urethra contrast-to-noise-ratios (CNR) were calculated for all images. Results: For two out of three observers, the urethra visibility score for 3D HASTE was significantly higher than CT, and clinical bSSFP, but was not significantly different from diagnostic MRI. The mean HD95/MDA/DICE values were 11.35 ± 3.55 mm/5.77 ± 2.69 mm/0.07 ± 0.08 for CT, 7.62 ± 2.75 mm/3.83 ± 1.47 mm/0.12 ± 0.10 for CT + diagnostic MRI, 5.49 ± 2.32 mm/2.18 ± 1.19 mm/0.35 ± 0.19 for 3D TSE, and 6.34 ± 2.89 mm/2.65 ± 1.31 mm/0.21 ± 0.12 for clinical bSSFP. The CNR for 3D HASTE was significantly higher than CT, diagnostic MRI, and clinical bSSFP, but was not significantly different from 3D TSE. Conclusion: The urethra’s visibility scores showed optimized urethral MRgRT 3D HASTE was superior to the other tested methodologies. The prostatic urethra contours demonstrated significant variability from different imaging and workflows. Urethra contouring uncertainty introduced by cross-modality registration and sub-optimal imaging contrast may lead to significant treatment degradation when urethral sparing is implemented to minimize genitourinary toxicity.
- Open Access
Interfractional Geometric Variations and Dosimetric Benefits of Stereotactic MRI Guided Online Adaptive Radiotherapy (SMART) of Prostate Bed after Radical Prostatectomy: Post-Hoc Analysis of a Phase II Trial
Purpose: To evaluate geometric variations of patients receiving stereotactic body radiotherapy (SBRT) after radical prostatectomy and the dosimetric benefits of stereotactic MRI guided adaptive radiotherapy (SMART) to compensate for these variations. Materials/Methods: The CTV and OAR were contoured on 55 MRI setup scans of 11 patients treated with an MR-LINAC and enrolled in a phase II trial of post-prostatectomy SBRT. All patients followed institutional bladder and rectum preparation protocols and received five fractions of 6−6.8 Gy to the prostate bed. Interfractional changes in volume were calculated and shape deformation was quantified by the Dice similar coefficient (DSC). Changes in CTV-V95%, bladder and rectum maximum dose, V32.5Gy and V27.5Gy were predicted by recalculating the initial plan on daily MRI. SMART was retrospectively simulated if the predicted dose exceeded pre-set criteria. Results: The CTV volume and shape remained stable with a median volumetric change of 3.0% (IQR −3.0% to 11.5%) and DSC of 0.83 (IQR 0.79 to 0.88). Relatively large volumetric changes in bladder (median −24.5%, IQR −34.6% to 14.5%) and rectum (median 5.4%, IQR − 9.7% to 20.7%) were observed while shape changes were moderate (median DSC of 0.79 and 0.73, respectively). The median CTV-V95% was 98.4% (IQR 94.9% to 99.6%) for the predicted doses. However, SMART would have been deemed beneficial for 78.2% of the 55 fractions based on target undercoverage (16.4%), exceeding OAR constraints (50.9%), or both (10.9%). Simulated SMART improved the dosimetry and met dosimetric criteria in all fractions. Moderate correlations were observed between the CTV-V95% and target DSC (R2 = 0.73) and bladder mean dose versus volumetric changes (R2 = 0.61). Conclusions: Interfractional dosimetric variations resulting from anatomic deformation are commonly encountered with post-prostatectomy RT and can be mitigated with SMART.
Open AccessInterfractional Geometric Variations and Dosimetric Benefits of Stereotactic MRI Guided Online Adaptive Radiotherapy (SMART) of Prostate Bed after Radical Prostatectomy: Post-Hoc Analysis of a Phase II Trial
Purpose: To evaluate geometric variations of patients receiving stereotactic body radiotherapy (SBRT) after radical prostatectomy and the dosimetric benefits of stereotactic MRI guided adaptive radiotherapy (SMART) to compensate for these variations. Materials/Methods: The CTV and OAR were contoured on 55 MRI setup scans of 11 patients treated with an MR-LINAC and enrolled in a phase II trial of post-prostatectomy SBRT. All patients followed institutional bladder and rectum preparation protocols and received five fractions of 6−6.8 Gy to the prostate bed. Interfractional changes in volume were calculated and shape deformation was quantified by the Dice similar coefficient (DSC). Changes in CTV-V95%, bladder and rectum maximum dose, V32.5Gy and V27.5Gy were predicted by recalculating the initial plan on daily MRI. SMART was retrospectively simulated if the predicted dose exceeded pre-set criteria. Results: The CTV volume and shape remained stable with a median volumetric change of 3.0% (IQR −3.0% to 11.5%) and DSC of 0.83 (IQR 0.79 to 0.88). Relatively large volumetric changes in bladder (median −24.5%, IQR −34.6% to 14.5%) and rectum (median 5.4%, IQR − 9.7% to 20.7%) were observed while shape changes were moderate (median DSC of 0.79 and 0.73, respectively). The median CTV-V95% was 98.4% (IQR 94.9% to 99.6%) for the predicted doses. However, SMART would have been deemed beneficial for 78.2% of the 55 fractions based on target undercoverage (16.4%), exceeding OAR constraints (50.9%), or both (10.9%). Simulated SMART improved the dosimetry and met dosimetric criteria in all fractions. Moderate correlations were observed between the CTV-V95% and target DSC (R2 = 0.73) and bladder mean dose versus volumetric changes (R2 = 0.61). Conclusions: Interfractional dosimetric variations resulting from anatomic deformation are commonly encountered with post-prostatectomy RT and can be mitigated with SMART.
- 7 February 2021
- Published by Wiley in Medical Physics
- Vol. 48 (4) , 1823-1831
Technical Note: Investigating internal–external motion correlation using fast helical CT
Purpose: To quantify the use of anterior torso skin surface position measurement as a breathing surrogate.Methods: Fourteen patients were scanned 25 times in alternating directions using a free‐breathing low‐mA fast helical CT protocol. Simultaneously, an abdominal pneumatic bellows was used as a real‐time breathing surrogate. The imaged diaphragm dome position was used as a gold standard surrogate, characterized by localizing the most superior points of the diaphragm dome in each lung. These positions were correlated against the bellows signal acquired at the corresponding scan times. The bellows system has been shown to have a slow linear drift, and the bellows‐to‐CT synchronization process had a small uncertainty, so the drift and time offset were determined by maximizing the correlation coefficient between the craniocaudal diaphragm position and the drift‐corrected bellows signal. The corresponding fit was used to model the real‐time diaphragm position. To estimate the effectiveness of skin surface positions as surrogates, the anterior torso surface position was measured from the CT scans and correlated against the diaphragm position model. The residual error was defined as the root‐mean‐square correlation residual with the breathing amplitude normalized to the 5th to 95th breathing amplitude percentiles. The fit residual errors were analyzed over the surface for the fourteen studied patients and reported as percentages of the 5th to 95th percentile ranges.Results: A strong correlation was measured between the diaphragm motion and the abdominal bellows signal with an average residual error of 9.21% and standard deviation of 3.77%. In contrast, the correlations between the diaphragm position model and patient surface positions varied throughout the torso and from patient to patient. However, a consistently high correlation was found near the abdomen for each patient, and the average minimum residual error relating the skin surface to the diaphragm was 11.8% with a standard deviation of 4.61%.Conclusions: The thoracic patient surface was found to be an accurate surrogate, but the accuracy varied across the surface sufficiently that care would need to be taken to use the surface as an accurate and reliable surrogate. Future studies will use surface imaging to determine surface patch algorithms that utilize the entire chest as well as thoracic and abdominal breathing relationships.
- 7 February 2021
- Published by Wiley in Medical Physics
- Vol. 48 (4) , 1823-1831
Technical Note: Investigating internal–external motion correlation using fast helical CT
Purpose: To quantify the use of anterior torso skin surface position measurement as a breathing surrogate.Methods: Fourteen patients were scanned 25 times in alternating directions using a free‐breathing low‐mA fast helical CT protocol. Simultaneously, an abdominal pneumatic bellows was used as a real‐time breathing surrogate. The imaged diaphragm dome position was used as a gold standard surrogate, characterized by localizing the most superior points of the diaphragm dome in each lung. These positions were correlated against the bellows signal acquired at the corresponding scan times. The bellows system has been shown to have a slow linear drift, and the bellows‐to‐CT synchronization process had a small uncertainty, so the drift and time offset were determined by maximizing the correlation coefficient between the craniocaudal diaphragm position and the drift‐corrected bellows signal. The corresponding fit was used to model the real‐time diaphragm position. To estimate the effectiveness of skin surface positions as surrogates, the anterior torso surface position was measured from the CT scans and correlated against the diaphragm position model. The residual error was defined as the root‐mean‐square correlation residual with the breathing amplitude normalized to the 5th to 95th breathing amplitude percentiles. The fit residual errors were analyzed over the surface for the fourteen studied patients and reported as percentages of the 5th to 95th percentile ranges.Results: A strong correlation was measured between the diaphragm motion and the abdominal bellows signal with an average residual error of 9.21% and standard deviation of 3.77%. In contrast, the correlations between the diaphragm position model and patient surface positions varied throughout the torso and from patient to patient. However, a consistently high correlation was found near the abdomen for each patient, and the average minimum residual error relating the skin surface to the diaphragm was 11.8% with a standard deviation of 4.61%.Conclusions: The thoracic patient surface was found to be an accurate surrogate, but the accuracy varied across the surface sufficiently that care would need to be taken to use the surface as an accurate and reliable surrogate. Future studies will use surface imaging to determine surface patch algorithms that utilize the entire chest as well as thoracic and abdominal breathing relationships.
- Open Access
- 1 March 2020
- Published by Wiley in Medical Physics
- Vol. 47 (3) , 833-836
Open access journals are the future of scientific publishing and medical physicist should embrace the change
- 1 March 2020
- Published by Wiley in Medical Physics
- Vol. 47 (3) , 833-836
Open AccessOpen access journals are the future of scientific publishing and medical physicist should embrace the change