H. Edwin Romeijn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
H. Edwin Romeijn has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Geunes
University of Florida
6 shared publications - James F. Dempsey
Chagrin Highlands Center
5 shared publications - Chunhua Men
Elekta Inc., 13723 Riverport Drive, Suite 100, Maryland Heights, MO 63043, United States
2 shared publications - Thomas C. Sharkey
Clemson University
2 shared publications - Z. Caner Taskin
Department of Industrial Engineering, Boǧaziçi University, Istanbul, Turkey
2 shared publications - Albert P. M. Wagelmans
Erasmus University Rotterdam
1 shared publication
Latest Publications
- 1 July 2012
- Published by Elsevier in Computers & Operations Research
- Vol. 39 (7) , 1779-1789
An efficient approach to incorporating interfraction motion in IMRT treatment planning
- 1 July 2012
- Published by Elsevier in Computers & Operations Research
- Vol. 39 (7) , 1779-1789
An efficient approach to incorporating interfraction motion in IMRT treatment planning
- 25 May 2012
- Published by Wiley in Medical Physics
- Vol. 39 (6Part1) , 3445-3455
Sensitivity analysis for lexicographic ordering in radiation therapy treatment planning
Purpose:: To introduce a method to efficiently identify and calculate meaningful tradeoffs between criteria in an interactive IMRT treatment planning procedure. The method provides a systematic approach to developing high‐quality radiation therapy treatment plans.Methods:: Treatment planners consider numerous dosimetric criteria of varying importance that, when optimized simultaneously through multicriteria optimization, yield a Pareto frontier which represents the set of Pareto‐optimal treatment plans. However, generating and navigating this frontier is a time‐consuming, nontrivial process. A lexicographic ordering (LO) approach to IMRT uses a physician's criteria preferences to partition the treatment planning decisions into a multistage treatment planning model. Because the relative importance of criteria optimized in the different stages may not necessarily constitute a strict prioritization, the authors introduce an interactive process, sensitivity analysis in lexicographic ordering (SALO), to allow the treatment planner control over the relative sequential‐stage tradeoffs. By allowing this flexibility within a structured process, SALO implicitly restricts attention to and allows exploration of a subset of the Pareto efficient frontier that the physicians have deemed most important.Results:: Improvements to treatment plans over a LO approach were found by implementing the SALO procedure on a brain case and a prostate case. In each stage, a physician assessed the tradeoff between previous stage and current stage criteria. The SALO method provided critical tradeoff information through curves approximating the relationship between criteria, which allowed the physician to determine the most desirable treatment plan.Conclusions:: The SALO procedure provides treatment planners with a directed, systematic process to treatment plan selection. By following a physician's prioritization, the treatment planner can avoid wasting effort considering clinically inferior treatment plans. The planner is guided by criteria importance, but given the information necessary to accurately adjust the relative importance at each stage. Through these attributes, the SALO procedure delivers an approach well balanced between efficiency and flexibility.
- 25 May 2012
- Published by Wiley in Medical Physics
- Vol. 39 (6Part1) , 3445-3455
Sensitivity analysis for lexicographic ordering in radiation therapy treatment planning
Purpose:: To introduce a method to efficiently identify and calculate meaningful tradeoffs between criteria in an interactive IMRT treatment planning procedure. The method provides a systematic approach to developing high‐quality radiation therapy treatment plans.Methods:: Treatment planners consider numerous dosimetric criteria of varying importance that, when optimized simultaneously through multicriteria optimization, yield a Pareto frontier which represents the set of Pareto‐optimal treatment plans. However, generating and navigating this frontier is a time‐consuming, nontrivial process. A lexicographic ordering (LO) approach to IMRT uses a physician's criteria preferences to partition the treatment planning decisions into a multistage treatment planning model. Because the relative importance of criteria optimized in the different stages may not necessarily constitute a strict prioritization, the authors introduce an interactive process, sensitivity analysis in lexicographic ordering (SALO), to allow the treatment planner control over the relative sequential‐stage tradeoffs. By allowing this flexibility within a structured process, SALO implicitly restricts attention to and allows exploration of a subset of the Pareto efficient frontier that the physicians have deemed most important.Results:: Improvements to treatment plans over a LO approach were found by implementing the SALO procedure on a brain case and a prostate case. In each stage, a physician assessed the tradeoff between previous stage and current stage criteria. The SALO method provided critical tradeoff information through curves approximating the relationship between criteria, which allowed the physician to determine the most desirable treatment plan.Conclusions:: The SALO procedure provides treatment planners with a directed, systematic process to treatment plan selection. By following a physician's prioritization, the treatment planner can avoid wasting effort considering clinically inferior treatment plans. The planner is guided by criteria importance, but given the information necessary to accurately adjust the relative importance at each stage. Through these attributes, the SALO procedure delivers an approach well balanced between efficiency and flexibility.
- 9 July 2011
- Published by Springer Nature in Journal of Heuristics
- Vol. 18 (2) , 297-315
A facility neighborhood search heuristic for capacitated facility location with single-source constraints and flexible demand
- 9 July 2011
- Published by Springer Nature in Journal of Heuristics
- Vol. 18 (2) , 297-315
A facility neighborhood search heuristic for capacitated facility location with single-source constraints and flexible demand
- 1 March 2011
- Published by Springer Nature in Mathematical Programming
- Vol. 134 (2) , 459-489
The static stochastic knapsack problem with normally distributed item sizes
- 1 March 2011
- Published by Springer Nature in Mathematical Programming
- Vol. 134 (2) , 459-489
The static stochastic knapsack problem with normally distributed item sizes
- Open Access
- 24 February 2011
- Published by Springer Nature in Mathematical Programming
- Vol. 134 (2) , 395-424
Integrated market selection and production planning: complexity and solution approaches
- 24 February 2011
- Published by Springer Nature in Mathematical Programming
- Vol. 134 (2) , 395-424
Open AccessIntegrated market selection and production planning: complexity and solution approaches
- 14 February 2011
- Published by Wiley in Medical Physics
- Vol. 38 (3) , 1266-1279
Accounting for the tongue‐and‐groove effect using a robust direct aperture optimization approach
Traditionally, the tongue-and-groove effect due to the multileaf collimator architecture in intensity-modulated radiation therapy (IMRT) has typically been deferred to the leaf sequencing stage. The authors propose a new direct aperture optimization method for IMRT treatment planning that explicitly incorporates dose calculation inaccuracies due to the tongue-and-groove effect into the treatment plan optimization stage. The authors avoid having to accurately estimate the dosimetric effects of the tongue-and-groove architecture by using lower and upper bounds on the dose distribution delivered to the patient. They then develop a model that yields a treatment plan that is robust with respect to the corresponding dose calculation inaccuracies. Tests on a set of ten clinical head-and-neck cancer cases demonstrate the effectiveness of the new method in developing robust treatment plans with tight dose distributions in targets and critical structures. This is contrasted with the very loose bounds on the dose distribution that are obtained by solving a traditional treatment plan optimization model that ignores tongue-and-groove effects in the treatment planning stage. A robust direct aperture optimization approach is proposed to account for the dosimetric inaccuracies caused by the tongue-and-groove effect. The experiments validate the ability of the proposed approach in designing robust treatment plans regardless of the exact consequences of the tongue-and-groove architecture.
- 14 February 2011
- Published by Wiley in Medical Physics
- Vol. 38 (3) , 1266-1279
Accounting for the tongue‐and‐groove effect using a robust direct aperture optimization approach
Traditionally, the tongue-and-groove effect due to the multileaf collimator architecture in intensity-modulated radiation therapy (IMRT) has typically been deferred to the leaf sequencing stage. The authors propose a new direct aperture optimization method for IMRT treatment planning that explicitly incorporates dose calculation inaccuracies due to the tongue-and-groove effect into the treatment plan optimization stage. The authors avoid having to accurately estimate the dosimetric effects of the tongue-and-groove architecture by using lower and upper bounds on the dose distribution delivered to the patient. They then develop a model that yields a treatment plan that is robust with respect to the corresponding dose calculation inaccuracies. Tests on a set of ten clinical head-and-neck cancer cases demonstrate the effectiveness of the new method in developing robust treatment plans with tight dose distributions in targets and critical structures. This is contrasted with the very loose bounds on the dose distribution that are obtained by solving a traditional treatment plan optimization model that ignores tongue-and-groove effects in the treatment planning stage. A robust direct aperture optimization approach is proposed to account for the dosimetric inaccuracies caused by the tongue-and-groove effect. The experiments validate the ability of the proposed approach in designing robust treatment plans regardless of the exact consequences of the tongue-and-groove architecture.
- 22 June 2010
- Published by Springer Nature in Annals of Operations Research
- Vol. 196 (1) , 799-818
Mixed-integer programming techniques for decomposing IMRT fluence maps using rectangular apertures
- 22 June 2010
- Published by Springer Nature in Annals of Operations Research
- Vol. 196 (1) , 799-818
Mixed-integer programming techniques for decomposing IMRT fluence maps using rectangular apertures
- 1 June 2010
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in Operations Research
- Vol. 58 (3) , 674-690
Optimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
We consider a problem dealing with the efficient delivery of intensity modulated radiation therapy (IMRT) to individual patients. IMRT treatment planning is usually performed in three phases. The first phase determines a set of beam angles through which radiation is delivered, followed by a second phase that determines an optimal radiation intensity profile (or fluence map). This intensity profile is selected to ensure that certain targets receive a required amount of dose while functional organs are spared. To deliver these intensity profiles to the patient, a third phase must decompose them into a collection of apertures and corresponding intensities. In this paper, we investigate this last problem. Formally, an intensity profile is represented as a nonnegative integer matrix; an aperture is represented as a binary matrix whose ones appear consecutively in each row. A feasible decomposition is one in which the original desired intensity profile is equal to the sum of a number of feasible binary matrices multiplied by corresponding intensity values. To most efficiently treat a patient, we wish to minimize a measure of total treatment time, which is given as a weighted sum of the number of apertures and the sum of the aperture intensities used in the decomposition. We develop the first exact algorithm capable of solving real-world problem instances to optimality within practicable computational limits, using a combination of integer programming decomposition and combinatorial search techniques. We demonstrate the efficacy of our approach on a set of 25 test instances derived from actual clinical data and on 100 randomly generated instances.
- 1 June 2010
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in Operations Research
- Vol. 58 (3) , 674-690
Optimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
We consider a problem dealing with the efficient delivery of intensity modulated radiation therapy (IMRT) to individual patients. IMRT treatment planning is usually performed in three phases. The first phase determines a set of beam angles through which radiation is delivered, followed by a second phase that determines an optimal radiation intensity profile (or fluence map). This intensity profile is selected to ensure that certain targets receive a required amount of dose while functional organs are spared. To deliver these intensity profiles to the patient, a third phase must decompose them into a collection of apertures and corresponding intensities. In this paper, we investigate this last problem. Formally, an intensity profile is represented as a nonnegative integer matrix; an aperture is represented as a binary matrix whose ones appear consecutively in each row. A feasible decomposition is one in which the original desired intensity profile is equal to the sum of a number of feasible binary matrices multiplied by corresponding intensity values. To most efficiently treat a patient, we wish to minimize a measure of total treatment time, which is given as a weighted sum of the number of apertures and the sum of the aperture intensities used in the decomposition. We develop the first exact algorithm capable of solving real-world problem instances to optimality within practicable computational limits, using a combination of integer programming decomposition and combinatorial search techniques. We demonstrate the efficacy of our approach on a set of 25 test instances derived from actual clinical data and on 100 randomly generated instances.
- 16 December 2009
- Published by Wiley in Naval Research Logistics (NRL)
- Vol. 57 (2) , 172-187
Multi‐item capacitated lot‐sizing problems with setup times and pricing decisions
We study a multi‐item capacitated lot‐sizing problem with setup times and pricing (CLSTP) over a finite and discrete planning horizon. In this class of problems, the demand for each independent item in each time period is affected by pricing decisions. The corresponding demands are then satisfied through production in a single capacitated facility or from inventory, and the goal is to set prices and determine a production plan that maximizes total profit. In contrast with many traditional lot‐sizing problems with fixed demands, we cannot, without loss of generality, restrict ourselves to instances without initial inventories, which greatly complicates the analysis of the CLSTP. We develop two alternative Dantzig–Wolfe decomposition formulations of the problem, and propose to solve their relaxations using column generation and the overall problem using branch‐and‐price. The associated pricing problem is studied under both dynamic and static pricing strategies. Through a computational study, we analyze both the efficacy of our algorithms and the benefits of allowing item prices to vary over time. © 2009 Wiley Periodicals, Inc. Naval Research Logistics, 2010
- 16 December 2009
- Published by Wiley in Naval Research Logistics (NRL)
- Vol. 57 (2) , 172-187
Multi‐item capacitated lot‐sizing problems with setup times and pricing decisions
We study a multi‐item capacitated lot‐sizing problem with setup times and pricing (CLSTP) over a finite and discrete planning horizon. In this class of problems, the demand for each independent item in each time period is affected by pricing decisions. The corresponding demands are then satisfied through production in a single capacitated facility or from inventory, and the goal is to set prices and determine a production plan that maximizes total profit. In contrast with many traditional lot‐sizing problems with fixed demands, we cannot, without loss of generality, restrict ourselves to instances without initial inventories, which greatly complicates the analysis of the CLSTP. We develop two alternative Dantzig–Wolfe decomposition formulations of the problem, and propose to solve their relaxations using column generation and the overall problem using branch‐and‐price. The associated pricing problem is studied under both dynamic and static pricing strategies. Through a computational study, we analyze both the efficacy of our algorithms and the benefits of allowing item prices to vary over time. © 2009 Wiley Periodicals, Inc. Naval Research Logistics, 2010
- 25 November 2009
- Published by Springer Nature in Mathematical Programming
- Vol. 130 (1) , 85-106
Approximation algorithms for supply chain planning and logistics problems with market choice
- 25 November 2009
- Published by Springer Nature in Mathematical Programming
- Vol. 130 (1) , 85-106
Approximation algorithms for supply chain planning and logistics problems with market choice