James F. Dempsey
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
James F. Dempsey has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- H. Edwin Romeijn
The University of Michigan
5 shared publications - Anneyuko I. Saito
Department of Radiation Oncology, Juntendo University Faculty of Medicine, Tokyo, Japan
1 shared publication - Chunhua Men
Elekta Inc., 13723 Riverport Drive, Suite 100, Maryland Heights, MO 63043, United States
1 shared publication Haisen S. Li
Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida 32610-0385, USA
1 shared publicationJ. Cole Smith
Department of Industrial and Systems Engineering, University of Florida, Gainesville, Florida 32611
1 shared publication- Z. Caner Taskin
Department of Industrial Engineering, Boǧaziçi University, Istanbul, Turkey
1 shared publication
Latest Publications
- 1 July 2012
- Published by Elsevier in Computers & Operations Research
- Vol. 39 (7) , 1779-1789
An efficient approach to incorporating interfraction motion in IMRT treatment planning
- 1 July 2012
- Published by Elsevier in Computers & Operations Research
- Vol. 39 (7) , 1779-1789
An efficient approach to incorporating interfraction motion in IMRT treatment planning
- 1 June 2010
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in Operations Research
- Vol. 58 (3) , 674-690
Optimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
We consider a problem dealing with the efficient delivery of intensity modulated radiation therapy (IMRT) to individual patients. IMRT treatment planning is usually performed in three phases. The first phase determines a set of beam angles through which radiation is delivered, followed by a second phase that determines an optimal radiation intensity profile (or fluence map). This intensity profile is selected to ensure that certain targets receive a required amount of dose while functional organs are spared. To deliver these intensity profiles to the patient, a third phase must decompose them into a collection of apertures and corresponding intensities. In this paper, we investigate this last problem. Formally, an intensity profile is represented as a nonnegative integer matrix; an aperture is represented as a binary matrix whose ones appear consecutively in each row. A feasible decomposition is one in which the original desired intensity profile is equal to the sum of a number of feasible binary matrices multiplied by corresponding intensity values. To most efficiently treat a patient, we wish to minimize a measure of total treatment time, which is given as a weighted sum of the number of apertures and the sum of the aperture intensities used in the decomposition. We develop the first exact algorithm capable of solving real-world problem instances to optimality within practicable computational limits, using a combination of integer programming decomposition and combinatorial search techniques. We demonstrate the efficacy of our approach on a set of 25 test instances derived from actual clinical data and on 100 randomly generated instances.
- 1 June 2010
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in Operations Research
- Vol. 58 (3) , 674-690
Optimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
We consider a problem dealing with the efficient delivery of intensity modulated radiation therapy (IMRT) to individual patients. IMRT treatment planning is usually performed in three phases. The first phase determines a set of beam angles through which radiation is delivered, followed by a second phase that determines an optimal radiation intensity profile (or fluence map). This intensity profile is selected to ensure that certain targets receive a required amount of dose while functional organs are spared. To deliver these intensity profiles to the patient, a third phase must decompose them into a collection of apertures and corresponding intensities. In this paper, we investigate this last problem. Formally, an intensity profile is represented as a nonnegative integer matrix; an aperture is represented as a binary matrix whose ones appear consecutively in each row. A feasible decomposition is one in which the original desired intensity profile is equal to the sum of a number of feasible binary matrices multiplied by corresponding intensity values. To most efficiently treat a patient, we wish to minimize a measure of total treatment time, which is given as a weighted sum of the number of apertures and the sum of the aperture intensities used in the decomposition. We develop the first exact algorithm capable of solving real-world problem instances to optimality within practicable computational limits, using a combination of integer programming decomposition and combinatorial search techniques. We demonstrate the efficacy of our approach on a set of 25 test instances derived from actual clinical data and on 100 randomly generated instances.
- 4 November 2008
- Published by Springer Nature in TOP
- Vol. 16 (2) , 256-257
Rejoinder on: Intensity modulated radiation therapy treatment plan optimization
- 4 November 2008
- Published by Springer Nature in TOP
- Vol. 16 (2) , 256-257
Rejoinder on: Intensity modulated radiation therapy treatment plan optimization
- 4 November 2008
- Published by Springer Nature in TOP
- Vol. 16 (2) , 215-243
Intensity modulated radiation therapy treatment plan optimization
- 4 November 2008
- Published by Springer Nature in TOP
- Vol. 16 (2) , 215-243
Intensity modulated radiation therapy treatment plan optimization
- 31 August 2006
- Published by Wiley in Medical Physics
- Vol. 33 (9) , 3508-3518
A Fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation
We developed an analytical method for determining the maximum acceptable grid size for discrete dose calculation in proton therapy treatment plan optimization, so that the accuracy of the optimized dose distribution is guaranteed in the phase of dose sampling and the superfluous computational work is avoided. The accuracy of dose sampling was judged by the criterion that the continuous dose distribution could be reconstructed from the discrete dose within a 2% error limit. To keep the error caused by the discrete dose sampling under a 2% limit, the dose grid size cannot exceed a maximum acceptable value. The method was based on Fourier analysis and the Shannon-Nyquist sampling theorem as an extension of our previous analysis for photon beam intensity modulated radiation therapy [J. F. Dempsey, H. E. Romeijn, J. G. Li, D. A. Low, and J. R. Palta, Med. Phys. 32, 380-388 (2005)]. The proton beam model used for the analysis was a near monoenergetic (of width about 1% the incident energy) and monodirectional infinitesimal (nonintegrated) pencil beam in water medium. By monodirection, we mean that the proton particles are in the same direction before entering the water medium and the various scattering prior to entrance to water is not taken into account. In intensity modulated proton therapy, the elementary intensity modulation entity for proton therapy is either an infinitesimal or finite sized beamlet. Since a finite sized beamlet is the superposition of infinitesimal pencil beams, the result of the maximum acceptable grid size obtained with infinitesimal pencil beam also applies to finite sized beamlet. The analytic Bragg curve function proposed by Bortfeld [T. Bortfeld, Med. Phys. 24, 2024-2033 (1997)] was employed. The lateral profile was approximated by a depth dependent Gaussian distribution. The model included the spreads of the Bragg peak and the lateral profiles due to multiple Coulomb scattering. The dependence of the maximum acceptable dose grid size on the orientation of the beam with respect to the dose grid was also investigated. The maximum acceptable dose grid size depends on the gradient of dose profile and in turn the range of proton beam. In the case that only the phantom scattering was considered and that the beam was aligned with the dose grid, grid sizes from 0.4 to 6.8 mm were required for proton beams with ranges from 2 to 30 cm for 2% error limit at the Bragg peak point. A near linear relation between the maximum acceptable grid size and beam range was observed. For this analysis model, the resolution requirement was not significantly related to the orientation of the beam with respect to the grid.
- 31 August 2006
- Published by Wiley in Medical Physics
- Vol. 33 (9) , 3508-3518
A Fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation
We developed an analytical method for determining the maximum acceptable grid size for discrete dose calculation in proton therapy treatment plan optimization, so that the accuracy of the optimized dose distribution is guaranteed in the phase of dose sampling and the superfluous computational work is avoided. The accuracy of dose sampling was judged by the criterion that the continuous dose distribution could be reconstructed from the discrete dose within a 2% error limit. To keep the error caused by the discrete dose sampling under a 2% limit, the dose grid size cannot exceed a maximum acceptable value. The method was based on Fourier analysis and the Shannon-Nyquist sampling theorem as an extension of our previous analysis for photon beam intensity modulated radiation therapy [J. F. Dempsey, H. E. Romeijn, J. G. Li, D. A. Low, and J. R. Palta, Med. Phys. 32, 380-388 (2005)]. The proton beam model used for the analysis was a near monoenergetic (of width about 1% the incident energy) and monodirectional infinitesimal (nonintegrated) pencil beam in water medium. By monodirection, we mean that the proton particles are in the same direction before entering the water medium and the various scattering prior to entrance to water is not taken into account. In intensity modulated proton therapy, the elementary intensity modulation entity for proton therapy is either an infinitesimal or finite sized beamlet. Since a finite sized beamlet is the superposition of infinitesimal pencil beams, the result of the maximum acceptable grid size obtained with infinitesimal pencil beam also applies to finite sized beamlet. The analytic Bragg curve function proposed by Bortfeld [T. Bortfeld, Med. Phys. 24, 2024-2033 (1997)] was employed. The lateral profile was approximated by a depth dependent Gaussian distribution. The model included the spreads of the Bragg peak and the lateral profiles due to multiple Coulomb scattering. The dependence of the maximum acceptable dose grid size on the orientation of the beam with respect to the dose grid was also investigated. The maximum acceptable dose grid size depends on the gradient of dose profile and in turn the range of proton beam. In the case that only the phantom scattering was considered and that the beam was aligned with the dose grid, grid sizes from 0.4 to 6.8 mm were required for proton beams with ranges from 2 to 30 cm for 2% error limit at the Bragg peak point. A near linear relation between the maximum acceptable grid size and beam range was observed. For this analysis model, the resolution requirement was not significantly related to the orientation of the beam with respect to the grid.