Scott S. Hsieh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Scott S. Hsieh has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Norbert J. Pelc
Departments of Radiology and Bioengineering, Stanford University, Stanford, California 94305
8 shared publicationsDominik Fleischmann
Departments of Radiology, Stanford University, Stanford, CA 94305, USA
2 shared publicationsBrian E. Nett
GE Healthcare (United States)
1 shared publicationBrian P. Wilfley
1 shared publicationChristopher A May
Departments of Bioengineering, Stanford University, Stanford, CA 94305, USA
1 shared publicationChristopher A. May
Stanford Univ. (United States)
1 shared publication
Latest Publications
- 12 August 2016
- Published by Wiley in Medical Physics
- Vol. 43 (9) , 5084-5092
Estimating scatter in cone beam CT with striped ratio grids: A preliminary investigation
Purpose: To propose a new method for estimating scatter in x-ray imaging. Conventional antiscatter grids reject scatter at an efficiency that is constant or slowly varying over the surface of the grid. A striped ratio antiscatter grid, composed of stripes that alternate between high and low grid ratio, could be used instead. Such a striped ratio grid would reduce scatter-to-primary ratio as a conventional grid would, but more importantly, the signal discontinuities at the boundaries of stripes can be used to estimate local scatter content. Methods: Signal discontinuities provide information on scatter, but are contaminated by variation in primary radiation. A nonlinear image processing algorithm is used to estimate the scatter content in the presence of primary variation. We emulated a striped ratio grid by imaging phantoms with two sequential CT scans, one with and one without a conventional grid. These two scans are processed together to mimic a striped ratio grid. This represents a best case limit of the striped ratio grid, in that the extent of grid ratio modulation is very high and the scatter contrast is maximized. Results: In a uniform cylinder, the striped ratio grid virtually eliminates cupping. Artifacts from scatter are improved in an anthropomorphic phantom. Some banding artifacts are induced by the striped ratio grid. Conclusions: Striped ratio grids could be a simple and effective evolution of conventional antiscatter grids. Construction and validation of a physical prototype remains an important future step.
- 12 August 2016
- Published by Wiley in Medical Physics
- Vol. 43 (9) , 5084-5092
Estimating scatter in cone beam CT with striped ratio grids: A preliminary investigation
Purpose: To propose a new method for estimating scatter in x-ray imaging. Conventional antiscatter grids reject scatter at an efficiency that is constant or slowly varying over the surface of the grid. A striped ratio antiscatter grid, composed of stripes that alternate between high and low grid ratio, could be used instead. Such a striped ratio grid would reduce scatter-to-primary ratio as a conventional grid would, but more importantly, the signal discontinuities at the boundaries of stripes can be used to estimate local scatter content. Methods: Signal discontinuities provide information on scatter, but are contaminated by variation in primary radiation. A nonlinear image processing algorithm is used to estimate the scatter content in the presence of primary variation. We emulated a striped ratio grid by imaging phantoms with two sequential CT scans, one with and one without a conventional grid. These two scans are processed together to mimic a striped ratio grid. This represents a best case limit of the striped ratio grid, in that the extent of grid ratio modulation is very high and the scatter contrast is maximized. Results: In a uniform cylinder, the striped ratio grid virtually eliminates cupping. Artifacts from scatter are improved in an anthropomorphic phantom. Some banding artifacts are induced by the striped ratio grid. Conclusions: Striped ratio grids could be a simple and effective evolution of conventional antiscatter grids. Construction and validation of a physical prototype remains an important future step.
- 10 June 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (13) , 4974-4988
A prototype piecewise-linear dynamic attenuator
The piecewise-linear dynamic attenuator has been proposed as a mechanism in CT scanning for personalizing the x-ray illumination on a patient- and application-specific basis. Previous simulations have shown benefits in image quality, scatter, and dose objectives. We report on the first prototype implementation. This prototype is reduced in scale and speed and is integrated into a tabletop CT system with a smaller field of view (25 cm) and longer scan time (42 s) compared to a clinical system. Stainless steel wedges were machined and affixed to linear actuators, which were in turn held secure by a frame built using rapid prototyping technologies. The actuators were computer-controlled, with characteristic noise of about 100 microns. Simulations suggest that in a clinical setting, the impact of actuator noise could lead to artifacts of only 1 HU. Ring artifacts were minimized by careful design of the wedges. A water beam hardening correction was applied and the scan was collimated to reduce scatter. We scanned a 16 cm water cylinder phantom as well as an anthropomorphic pediatric phantom. The artifacts present in reconstructed images are comparable to artifacts normally seen with this tabletop system. Compared to a flat-field reference scan, increased detectability at reduced dose is shown and streaking is reduced. Artifacts are modest in our images and further refinement is possible. Issues of mechanical speed and stability in the challenging clinical CT environment will be addressed in a future design.
- 10 June 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (13) , 4974-4988
A prototype piecewise-linear dynamic attenuator
The piecewise-linear dynamic attenuator has been proposed as a mechanism in CT scanning for personalizing the x-ray illumination on a patient- and application-specific basis. Previous simulations have shown benefits in image quality, scatter, and dose objectives. We report on the first prototype implementation. This prototype is reduced in scale and speed and is integrated into a tabletop CT system with a smaller field of view (25 cm) and longer scan time (42 s) compared to a clinical system. Stainless steel wedges were machined and affixed to linear actuators, which were in turn held secure by a frame built using rapid prototyping technologies. The actuators were computer-controlled, with characteristic noise of about 100 microns. Simulations suggest that in a clinical setting, the impact of actuator noise could lead to artifacts of only 1 HU. Ring artifacts were minimized by careful design of the wedges. A water beam hardening correction was applied and the scan was collimated to reduce scatter. We scanned a 16 cm water cylinder phantom as well as an anthropomorphic pediatric phantom. The artifacts present in reconstructed images are comparable to artifacts normally seen with this tabletop system. Compared to a flat-field reference scan, increased detectability at reduced dose is shown and streaking is reduced. Artifacts are modest in our images and further refinement is possible. Issues of mechanical speed and stability in the challenging clinical CT environment will be addressed in a future design.
- 23 February 2016
- Published by Wiley in Medical Physics
- Vol. 43 (3) , 1361-1368
A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject
Purpose: To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object.Methods: The authors examined the task of estimating the density of a circular lesion in a cross section. Raw data were simulated by forward projection of existing images and numerical phantoms. To assess an upper bound on the achievable dose reduction by any algorithm, the authors assume that both the background and the shape of the lesion are completely known. Under these conditions, the best possible estimate of the density can be determined by solving a weighted least squares problem directly in the raw data domain. Any possible reconstruction algorithm that does not use prior knowledge or make assumptions about the object, including filtered backprojection (FBP) or iterative reconstruction methods with this constraint, must be no better than this least squares solution. The authors simulated 10 000 sets of noisy data and compared the variance in density from the least squares solution with those from FBP. Density was estimated from FBP images using either averaging within a ROI, or streak‐adaptive averaging with better noise performance.Results: The bound on the possible dose reduction depends on the degree to which the observer can read through the possibly streaky noise. For the described low contrast detection task with the signal shape and background known exactly, the average dose reduction possible compared to FBP with streak‐adaptive averaging was 42% and it was 64% if only the ROI average is used with FBP. The exact amount of dose reduction also depends on the background anatomy, with statistically inhomogeneous backgrounds showing greater benefits.Conclusions: The dose reductions from new, statistical reconstruction methods can be bounded. Larger dose reductions in the density estimation task studied here are only possible with the introduction of prior knowledge, which can introduce bias.
- 23 February 2016
- Published by Wiley in Medical Physics
- Vol. 43 (3) , 1361-1368
A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject
Purpose: To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object.Methods: The authors examined the task of estimating the density of a circular lesion in a cross section. Raw data were simulated by forward projection of existing images and numerical phantoms. To assess an upper bound on the achievable dose reduction by any algorithm, the authors assume that both the background and the shape of the lesion are completely known. Under these conditions, the best possible estimate of the density can be determined by solving a weighted least squares problem directly in the raw data domain. Any possible reconstruction algorithm that does not use prior knowledge or make assumptions about the object, including filtered backprojection (FBP) or iterative reconstruction methods with this constraint, must be no better than this least squares solution. The authors simulated 10 000 sets of noisy data and compared the variance in density from the least squares solution with those from FBP. Density was estimated from FBP images using either averaging within a ROI, or streak‐adaptive averaging with better noise performance.Results: The bound on the possible dose reduction depends on the degree to which the observer can read through the possibly streaky noise. For the described low contrast detection task with the signal shape and background known exactly, the average dose reduction possible compared to FBP with streak‐adaptive averaging was 42% and it was 64% if only the ROI average is used with FBP. The exact amount of dose reduction also depends on the background anatomy, with statistically inhomogeneous backgrounds showing greater benefits.Conclusions: The dose reductions from new, statistical reconstruction methods can be bounded. Larger dose reductions in the density estimation task studied here are only possible with the introduction of prior knowledge, which can introduce bias.
- 18 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9412
First results from a prototype dynamic attenuator system
The dynamic, piecewise-linear attenuator has been proposed as a concept which can shape the radiation flux incident on the patient. By reducing the signal to photon-rich measurements and increasing the signal to photon-starved measurements, the piecewise-linear attenuator has been shown to improve dynamic range, scatter, and variance and dose metrics in simulation. The piecewise-linear nature of the proposed attenuator has been hypothesized to mitigate artifacts at transitions by eliminating jump discontinuities in attenuator thickness at these points. We report the results of a prototype implementation of this concept. The attenuator was constructed using rapid prototyping technologies and was affixed to a tabletop x-ray system. Images of several sections of an anthropormophic pediatric phantom were produced and compared to those of the same system with uniform illumination. The thickness of the illuminated slab was limited by beam collimation and an analytic water beam hardening correction was used for both systems. Initial results are encouraging and show improved image quality, reduced dose and low artifact levels.
- 18 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9412
First results from a prototype dynamic attenuator system
The dynamic, piecewise-linear attenuator has been proposed as a concept which can shape the radiation flux incident on the patient. By reducing the signal to photon-rich measurements and increasing the signal to photon-starved measurements, the piecewise-linear attenuator has been shown to improve dynamic range, scatter, and variance and dose metrics in simulation. The piecewise-linear nature of the proposed attenuator has been hypothesized to mitigate artifacts at transitions by eliminating jump discontinuities in attenuator thickness at these points. We report the results of a prototype implementation of this concept. The attenuator was constructed using rapid prototyping technologies and was affixed to a tabletop x-ray system. Images of several sections of an anthropormophic pediatric phantom were produced and compared to those of the same system with uniform illumination. The thickness of the illuminated slab was limited by beam collimation and an analytic water beam hardening correction was used for both systems. Initial results are encouraging and show improved image quality, reduced dose and low artifact levels.
- 15 May 2014
- Published by Wiley in Medical Physics
- Vol. 41 (6Part1) , 061907
Control algorithms for dynamic attenuators
The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not require a priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current modulation) without increasing peak variance. The 15-element piecewise-linear dynamic attenuator reduces dose by an average of 42%, and the perfect attenuator reduces dose by an average of 50%. Improvements in peak variance are several times larger than improvements in mean variance. Heuristic control eliminates the need for a prescan. For the piecewise-linear attenuator, the cost of heuristic control is an increase in dose of 9%. The proposed iterated WMV minimization produces results that are within a few percent of the true solution. Dynamic attenuators show potential for significant dose reduction. A wide class of dynamic attenuators can be accurately controlled using the described methods.
- 15 May 2014
- Published by Wiley in Medical Physics
- Vol. 41 (6Part1) , 061907
Control algorithms for dynamic attenuators
The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not require a priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current modulation) without increasing peak variance. The 15-element piecewise-linear dynamic attenuator reduces dose by an average of 42%, and the perfect attenuator reduces dose by an average of 50%. Improvements in peak variance are several times larger than improvements in mean variance. Heuristic control eliminates the need for a prescan. For the piecewise-linear attenuator, the cost of heuristic control is an increase in dose of 9%. The proposed iterated WMV minimization produces results that are within a few percent of the true solution. Dynamic attenuators show potential for significant dose reduction. A wide class of dynamic attenuators can be accurately controlled using the described methods.
- 30 January 2014
- Published by Wiley in Medical Physics
- Vol. 41 (2) , 021910
Dose reduction using a dynamic, piecewise‐linear attenuator
Purpose:: The authors recently proposed a dynamic, prepatient x‐ray attenuator capable of producing a piecewise‐linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter‐to‐primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations.Methods:: The authors selected four clinical applications, including routine full field‐of‐view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals.Results:: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic attenuator was relatively insensitive to patient centering, showing a 17% increase in peak variance for a 6 cm shift of the abdomen, instead of an 82% increase in peak variance for a fixed bowtie filter.Conclusions:: A dynamic prepatient x‐ray attenuator consisting of multiple wedges is capable of achieving substantial dose reductions and modest SPR reductions.
- 30 January 2014
- Published by Wiley in Medical Physics
- Vol. 41 (2) , 021910
Dose reduction using a dynamic, piecewise‐linear attenuator
Purpose:: The authors recently proposed a dynamic, prepatient x‐ray attenuator capable of producing a piecewise‐linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter‐to‐primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations.Methods:: The authors selected four clinical applications, including routine full field‐of‐view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals.Results:: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic attenuator was relatively insensitive to patient centering, showing a 17% increase in peak variance for a 6 cm shift of the abdomen, instead of an 82% increase in peak variance for a fixed bowtie filter.Conclusions:: A dynamic prepatient x‐ray attenuator consisting of multiple wedges is capable of achieving substantial dose reductions and modest SPR reductions.
- 19 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8668, 86683N
Truncation artifact correction by support recovery
Truncation artifacts arise when the object being imaged extends past the scanned field of view (SFOV). The line integrals which lie beyond the SFOV are unmeasured, and reconstruction with traditional filtered backprojection (FBP) produces bright signal artifacts at the edge of the SFOV and little useful information outside the SFOV. A variety of techniques have been proposed to correct for truncation artifacts by estimating the unmeasured rays. We explore an alternative, iterative correction technique that reduces the artifacts and recovers the support (or outline) of the object that is consistent with the measured rays. We assume that the support is filled uniformly with tissue of a given CT number (for example, water-equivalent soft tissue) and segment the region outside the SFOV in a dichotomous fashion into tissue and air. In general, any choice for the object support will not be consistent with the measured rays in that a forward projection of the image containing the proposed support will not match the measured rays. The proposed algorithm reduces this inconsistency by deforming the object support to better match the measured rays. We initialize the reconstruction using the water cylinder extrapolation algorithm, an existing truncation artifact correction technique, but other starting algorithms can be used. The estimate of the object support is then iteratively deformed to reduce the inconsistency with the measured rays. After several iterations, forward projection is used to estimate the missing rays. Preliminary results indicate that this iterative, support recovery technique is able to produce superior reconstructions in the case of significant truncation compared to water cylinder extrapolation.
- 19 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8668, 86683N
Truncation artifact correction by support recovery
Truncation artifacts arise when the object being imaged extends past the scanned field of view (SFOV). The line integrals which lie beyond the SFOV are unmeasured, and reconstruction with traditional filtered backprojection (FBP) produces bright signal artifacts at the edge of the SFOV and little useful information outside the SFOV. A variety of techniques have been proposed to correct for truncation artifacts by estimating the unmeasured rays. We explore an alternative, iterative correction technique that reduces the artifacts and recovers the support (or outline) of the object that is consistent with the measured rays. We assume that the support is filled uniformly with tissue of a given CT number (for example, water-equivalent soft tissue) and segment the region outside the SFOV in a dichotomous fashion into tissue and air. In general, any choice for the object support will not be consistent with the measured rays in that a forward projection of the image containing the proposed support will not match the measured rays. The proposed algorithm reduces this inconsistency by deforming the object support to better match the measured rays. We initialize the reconstruction using the water cylinder extrapolation algorithm, an existing truncation artifact correction technique, but other starting algorithms can be used. The estimate of the object support is then iteratively deformed to reduce the inconsistency with the measured rays. After several iterations, forward projection is used to estimate the missing rays. Preliminary results indicate that this iterative, support recovery technique is able to produce superior reconstructions in the case of significant truncation compared to water cylinder extrapolation.
- 19 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8668, 86681Q
Optimized control of a dynamic, prepatient attenuator
Dynamic attenuators are beam shaping filters that can customize the x-ray illumination field to the clinical task and for each view. These dynamic attenuators replace traditional attenuators (or “bowtie filters”) and decrease radiation dose, dynamic range, and scatter when compared to their static counterparts. We propose a one-dimensional dynamic attenuator that comprises multiple wedges with axially-dependent triangular cross-sections, and which are translated in the axial direction. These wedges together produce a time-varying, piecewise-linear attenuation function. We investigate different control methods for this attenuator and estimate the ability of the dynamic attenuator to reduce dose while maintaining the peak variance of the scan. With knowledge of the patient anatomy, the dynamic attenuator can be controlled by solving a convex optimization problem. This knowledge could be determined from a low dose pre-scan. Absent this information, various heuristics can be used. We simulate the dynamic attenuator on datasets of the thorax, abdomen, and a targeted scan of an abdominal aortic aneurysm. The dose and scatter-to-primary ratio (SPR) are estimated using Monte Carlo simulations, and the noise is calculated analytically. Compared to a system using the standard bowtie with typical mA modulation, dose reductions of 50% are observed. Compared to an optimized, patientspecific mA modulation, the typical dose reduction is 30%. If the dynamic attenuator is controlled with a heuristic, typical dose reductions are also 30%. The gains are larger in the targeted scan. The SPR is also reduced by 20% in the abdomen. We conclude that the dynamic attenuator has significant potential to reduce dose without increasing the peak variance of the scan.
- 19 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8668, 86681Q
Optimized control of a dynamic, prepatient attenuator
Dynamic attenuators are beam shaping filters that can customize the x-ray illumination field to the clinical task and for each view. These dynamic attenuators replace traditional attenuators (or “bowtie filters”) and decrease radiation dose, dynamic range, and scatter when compared to their static counterparts. We propose a one-dimensional dynamic attenuator that comprises multiple wedges with axially-dependent triangular cross-sections, and which are translated in the axial direction. These wedges together produce a time-varying, piecewise-linear attenuation function. We investigate different control methods for this attenuator and estimate the ability of the dynamic attenuator to reduce dose while maintaining the peak variance of the scan. With knowledge of the patient anatomy, the dynamic attenuator can be controlled by solving a convex optimization problem. This knowledge could be determined from a low dose pre-scan. Absent this information, various heuristics can be used. We simulate the dynamic attenuator on datasets of the thorax, abdomen, and a targeted scan of an abdominal aortic aneurysm. The dose and scatter-to-primary ratio (SPR) are estimated using Monte Carlo simulations, and the noise is calculated analytically. Compared to a system using the standard bowtie with typical mA modulation, dose reductions of 50% are observed. Compared to an optimized, patientspecific mA modulation, the typical dose reduction is 30%. If the dynamic attenuator is controlled with a heuristic, typical dose reductions are also 30%. The gains are larger in the targeted scan. The SPR is also reduced by 20% in the abdomen. We conclude that the dynamic attenuator has significant potential to reduce dose without increasing the peak variance of the scan.
- 25 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031910
The feasibility of a piecewise‐linear dynamic bowtie filter
Purpose:: The prepatient attenuator (or “bowtie filter”) in CT is used to modulate the flux as a function of fan angle of the x‐ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time‐dependent piecewise‐linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon‐counting detectors.Methods:: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time‐dependent piecewise‐linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated.Results:: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two‐pass algorithm.Conclusions:: A dynamic bowtie producing a time‐dependent, piecewise‐linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.
- 25 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031910
The feasibility of a piecewise‐linear dynamic bowtie filter
Purpose:: The prepatient attenuator (or “bowtie filter”) in CT is used to modulate the flux as a function of fan angle of the x‐ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time‐dependent piecewise‐linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon‐counting detectors.Methods:: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time‐dependent piecewise‐linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated.Results:: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two‐pass algorithm.Conclusions:: A dynamic bowtie producing a time‐dependent, piecewise‐linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.
- 14 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031904
The feasibility of an inverse geometry CT system with stationary source arrays
Purpose:: Inverse geometry computed tomography (IGCT) has been proposed as a new system architecture that combines a small detector with a large, distributed source. This geometry can suppress cone‐beam artifacts, reduce scatter, and increase dose efficiency. However, the temporal resolution of IGCT is still limited by the gantry rotation time. Large reductions in rotation time are in turn difficult due to the large source array and associated power electronics. We examine the feasibility of using stationary source arrays for IGCT in order to achieve better temporal resolution. We anticipate that multiple source arrays are necessary, with each source array physically separated from adjacent ones.Methods:: Key feasibility issues include spatial resolution, artifacts, flux, noise, collimation, and system timing clashes. The separation between the different source arrays leads to missing views, complicating reconstruction. For the special case of three source arrays, a two‐stage reconstruction algorithm is used to estimate the missing views. Collimation is achieved using a rotating collimator with a small number of holes. A set of equally spaced source spots are designated on the source arrays, and a source spot is energized when a collimator hole is aligned with it. System timing clashes occur when multiple source spots are scheduled to be energized simultaneously. We examine flux considerations to evaluate whether sufficient flux is available for clinical applications.Results:: The two‐stage reconstruction algorithm suppresses cone‐beam artifacts while maintaining resolution and noise characteristics comparable to standard third generation systems. The residual artifacts are much smaller in magnitude than the cone‐beam artifacts eliminated. A mathematical condition is given relating collimator hole locations and the number of virtual source spots for which system timing clashes are avoided. With optimization, sufficient flux may be achieved for many clinical applications.Conclusions:: IGCT with stationary source arrays could be an imaging platform potentially capable of imaging a complete 16‐cm thick volume within a tenth of a second.
- 14 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031904
The feasibility of an inverse geometry CT system with stationary source arrays
Purpose:: Inverse geometry computed tomography (IGCT) has been proposed as a new system architecture that combines a small detector with a large, distributed source. This geometry can suppress cone‐beam artifacts, reduce scatter, and increase dose efficiency. However, the temporal resolution of IGCT is still limited by the gantry rotation time. Large reductions in rotation time are in turn difficult due to the large source array and associated power electronics. We examine the feasibility of using stationary source arrays for IGCT in order to achieve better temporal resolution. We anticipate that multiple source arrays are necessary, with each source array physically separated from adjacent ones.Methods:: Key feasibility issues include spatial resolution, artifacts, flux, noise, collimation, and system timing clashes. The separation between the different source arrays leads to missing views, complicating reconstruction. For the special case of three source arrays, a two‐stage reconstruction algorithm is used to estimate the missing views. Collimation is achieved using a rotating collimator with a small number of holes. A set of equally spaced source spots are designated on the source arrays, and a source spot is energized when a collimator hole is aligned with it. System timing clashes occur when multiple source spots are scheduled to be energized simultaneously. We examine flux considerations to evaluate whether sufficient flux is available for clinical applications.Results:: The two‐stage reconstruction algorithm suppresses cone‐beam artifacts while maintaining resolution and noise characteristics comparable to standard third generation systems. The residual artifacts are much smaller in magnitude than the cone‐beam artifacts eliminated. A mathematical condition is given relating collimator hole locations and the number of virtual source spots for which system timing clashes are avoided. With optimization, sufficient flux may be achieved for many clinical applications.Conclusions:: IGCT with stationary source arrays could be an imaging platform potentially capable of imaging a complete 16‐cm thick volume within a tenth of a second.