Estimating scatter in cone beam CT with striped ratio grids: A preliminary investigation
Author:
- 12 August 2016
- journal article
- Published by Wiley in Medical Physics
- Vol. 43 (9) , 5084-5092
Abstract
Purpose: To propose a new method for estimating scatter in x-ray imaging. Conventional antiscatter grids reject scatter at an efficiency that is constant or slowly varying over the surface of the grid. A striped ratio antiscatter grid, composed of stripes that alternate between high and low grid ratio, could be used instead. Such a striped ratio grid would reduce scatter-to-primary ratio as a conventional grid would, but more importantly, the signal discontinuities at the boundaries of stripes can be used to estimate local scatter content. Methods: Signal discontinuities provide information on scatter, but are contaminated by variation in primary radiation. A nonlinear image processing algorithm is used to estimate the scatter content in the presence of primary variation. We emulated a striped ratio grid by imaging phantoms with two sequential CT scans, one with and one without a conventional grid. These two scans are processed together to mimic a striped ratio grid. This represents a best case limit of the striped ratio grid, in that the extent of grid ratio modulation is very high and the scatter contrast is maximized. Results: In a uniform cylinder, the striped ratio grid virtually eliminates cupping. Artifacts from scatter are improved in an anthropomorphic phantom. Some banding artifacts are induced by the striped ratio grid. Conclusions: Striped ratio grids could be a simple and effective evolution of conventional antiscatter grids. Construction and validation of a physical prototype remains an important future step.Keywords
This publication has 17 references indexed in Scilit:
- The feasibility of a piecewise‐linear dynamic bowtie filterMedical Physics, 2013
- Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation frameworkMedical Physics, 2013
- A general framework and review of scatter correction methods in cone beam CT. Part 2: Scatter estimation approachesMedical Physics, 2011
- A general framework and review of scatter correction methods in x‐ray cone‐beam computerized tomography. Part 1: Scatter compensation approachesMedical Physics, 2011
- Improved scatter correction using adaptive scatter kernel superpositionPhysics in Medicine & Biology, 2010
- Scatter correction method for x‐ray CT using primary modulation: Phantom studiesMedical Physics, 2010
- An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CTPhysics in Medicine & Biology, 2009
- Efficiency of antiscatter grids for flat-detector CTPhysics in Medicine & Biology, 2007
- Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CTPhysics in Medicine & Biology, 2006
- Compton scatter effects in CT reconstructionsMedical Physics, 1982