Binsheng Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Binsheng Zhao has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Lawrence H. Schwartz
Department of Radiology, Columbia University Medical Center, New York, NY
11 shared publicationsLi Jiang
4 shared publicationsMichelle S. Ginsberg
4 shared publicationsChaya S. Moskowitz
3 shared publications- Lawrence H. Schwartz
Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York 10021, USA
3 shared publications Liang Wang
3 shared publications
Latest Publications
- 20 May 2017
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 35 (15_suppl) , 2563
Pharmaco-kinetics/dynamics (PK/PD) evaluation and individual patient cross-over studies with growth trajectory assessment to adaptively develop ilorasertib.
2563 Background: We evaluated PK/PD of the AURK B/VEGFR2 inhibitor ilorasertib. To detect activity in CDKN2A-deficient tumors, we measured changes-in-tumor-burden by CT-volume before, during, and after discontinuation of therapy. Methods: Study 1: open-label, dose-escalation, phase 1 in 58 patients (pts) with advanced solid tumors. Arms I, II, and III assigned: 23 pts (10–180 mg oral QD), 28 pts (40–340 mg oral BID), and 7 pts (8–32 mg i.v. QD), to ilorasertib monotherapy Days 1, 8, and 15 every 28 days. We evaluated PK/PD for validated biomarkers: change-in-diastolic blood pressure (ΔDBP), change-in-plasma [PlGF] (ΔPlGF), and change-in phosphorylated histone H3 (Δ%pHH3) in skin biopsies. Study 2: open-label trial, of 10 solid tumor pts with CLIA-lab-detected CDKN2A disruption. Pts received ilorasertib 250 mg oral BID on same schedule. On CT images collected prior to screening, and ~ study days -7, 49, and 98 individual lesion volumes were determined by central lab semi-automated segmentation algorithms on DICOM files. Pts who tolerated ilorasertib with RECIST-stable disease at day 98 discontinued ilorasertib for 42 days and underwent re-imaging before restarting ilorasertib. Results: Study 1: the DLTs and frequent adverse events reflected VEGFR2 inhibition. PK/PD analysis showed peak VEGFR2 inhibition on ΔDBP and ΔPlGF at lower systemic concentrations than for peak AURKB-inhibition detected with Δ%pHH3. Two pts in Arm II had partial response; one had homozygous deletion of CDKN2Aby FISH. Pre-clinically the CDKN2A-deficient cell lines (OVCAR5, MDA MB 231, A549) were among the most ilorasertib-sensitive. At time of submission, Study II enrolled 10 pts, with 5 evaluable for longitudinal tumor burden assessments. Three pts had sustained negative growth trajectories after ilorasertib therapy; one of these had positive growth after cessation of treatment but restabilization of disease after restarting ilorasertib. Conclusions: The development plan adapted to the in-human PK/PD assessment. We prospectively conducted individual change-in-tumor burden cross-over studies to assess clinically the sensitivity of CDKN2A-deficient tumors. Clinical trial information: NCT02540876 and NCT01110486.
- 20 May 2017
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 35 (15_suppl) , 2563
Pharmaco-kinetics/dynamics (PK/PD) evaluation and individual patient cross-over studies with growth trajectory assessment to adaptively develop ilorasertib.
2563 Background: We evaluated PK/PD of the AURK B/VEGFR2 inhibitor ilorasertib. To detect activity in CDKN2A-deficient tumors, we measured changes-in-tumor-burden by CT-volume before, during, and after discontinuation of therapy. Methods: Study 1: open-label, dose-escalation, phase 1 in 58 patients (pts) with advanced solid tumors. Arms I, II, and III assigned: 23 pts (10–180 mg oral QD), 28 pts (40–340 mg oral BID), and 7 pts (8–32 mg i.v. QD), to ilorasertib monotherapy Days 1, 8, and 15 every 28 days. We evaluated PK/PD for validated biomarkers: change-in-diastolic blood pressure (ΔDBP), change-in-plasma [PlGF] (ΔPlGF), and change-in phosphorylated histone H3 (Δ%pHH3) in skin biopsies. Study 2: open-label trial, of 10 solid tumor pts with CLIA-lab-detected CDKN2A disruption. Pts received ilorasertib 250 mg oral BID on same schedule. On CT images collected prior to screening, and ~ study days -7, 49, and 98 individual lesion volumes were determined by central lab semi-automated segmentation algorithms on DICOM files. Pts who tolerated ilorasertib with RECIST-stable disease at day 98 discontinued ilorasertib for 42 days and underwent re-imaging before restarting ilorasertib. Results: Study 1: the DLTs and frequent adverse events reflected VEGFR2 inhibition. PK/PD analysis showed peak VEGFR2 inhibition on ΔDBP and ΔPlGF at lower systemic concentrations than for peak AURKB-inhibition detected with Δ%pHH3. Two pts in Arm II had partial response; one had homozygous deletion of CDKN2Aby FISH. Pre-clinically the CDKN2A-deficient cell lines (OVCAR5, MDA MB 231, A549) were among the most ilorasertib-sensitive. At time of submission, Study II enrolled 10 pts, with 5 evaluable for longitudinal tumor burden assessments. Three pts had sustained negative growth trajectories after ilorasertib therapy; one of these had positive growth after cessation of treatment but restabilization of disease after restarting ilorasertib. Conclusions: The development plan adapted to the in-human PK/PD assessment. We prospectively conducted individual change-in-tumor burden cross-over studies to assess clinically the sensitivity of CDKN2A-deficient tumors. Clinical trial information: NCT02540876 and NCT01110486.
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3) , 542
Semi-automated validation of centralized independent review of radiological data in the OPUS trial.
542 Background: There is increasing evidence that evaluation of tumor shrinkage on a continuous scale early on during treatment in metastatic colorectal cancer (mCRC) contains predictive information on long term treatment benefit. These findings were more specifically observed in trials evaluating addition of cetuximab to chemotherapy in first line mCRC (Piessevaux, JCO, 2013). Precise tumor measurements are necessary to implement these findings in clinical trials and practice. Independent central review has been advocated to improve the validity of the radiological measurements in clinical trials. In the phase II mCRC OPUS trial, we compared tumor shrinkage assessments given by an independent review committee (IRC) to results of a semi-automated software algorithm (SOFT). Methods: IRC measurements were performed and reported previously. SOFT requires a seed placement in a metastatic deposit. Once the seed placement is made, the computer automatically generates the boundary of the lesion and calculates the maximal diameter. The original digital radiological data from 217/337 ITT patients was available for review. Early tumor shrinkage, defined as the relative change at week 8 of the sum of the longest diameters was calculated with both measures and compared (ETS-IRC vs. ETS-SOFT). Results: The intra-class coefficient of correlation between ETS-IRC and ETS-SOFT was 0.689 (95%CI 0.604-0.759). When the population was split according to treatment group we observed the following ICC: 0.874 (95%CI: 0.815-0.914) in the chemotherapy with cetuximab arm and 0.486 (0.307-0.632) in the chemotherapy alone arm. Conclusions: Secondary independent review of radiological data from the OPUS trial showed discrepancies between IRC and SOFT. These discrepancies are potentially due to target lesion number and selection. Treatment group seems to differentiate cases more prone to discrepant review. This finding may be related to enhanced reliability when treatment effect is more pronounced. Further comparisons of traditional IRC reviews to semi-automated algorithm-based reviews with regard to outcome evaluation are warranted.
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3) , 542
Semi-automated validation of centralized independent review of radiological data in the OPUS trial.
542 Background: There is increasing evidence that evaluation of tumor shrinkage on a continuous scale early on during treatment in metastatic colorectal cancer (mCRC) contains predictive information on long term treatment benefit. These findings were more specifically observed in trials evaluating addition of cetuximab to chemotherapy in first line mCRC (Piessevaux, JCO, 2013). Precise tumor measurements are necessary to implement these findings in clinical trials and practice. Independent central review has been advocated to improve the validity of the radiological measurements in clinical trials. In the phase II mCRC OPUS trial, we compared tumor shrinkage assessments given by an independent review committee (IRC) to results of a semi-automated software algorithm (SOFT). Methods: IRC measurements were performed and reported previously. SOFT requires a seed placement in a metastatic deposit. Once the seed placement is made, the computer automatically generates the boundary of the lesion and calculates the maximal diameter. The original digital radiological data from 217/337 ITT patients was available for review. Early tumor shrinkage, defined as the relative change at week 8 of the sum of the longest diameters was calculated with both measures and compared (ETS-IRC vs. ETS-SOFT). Results: The intra-class coefficient of correlation between ETS-IRC and ETS-SOFT was 0.689 (95%CI 0.604-0.759). When the population was split according to treatment group we observed the following ICC: 0.874 (95%CI: 0.815-0.914) in the chemotherapy with cetuximab arm and 0.486 (0.307-0.632) in the chemotherapy alone arm. Conclusions: Secondary independent review of radiological data from the OPUS trial showed discrepancies between IRC and SOFT. These discrepancies are potentially due to target lesion number and selection. Treatment group seems to differentiate cases more prone to discrepant review. This finding may be related to enhanced reliability when treatment effect is more pronounced. Further comparisons of traditional IRC reviews to semi-automated algorithm-based reviews with regard to outcome evaluation are warranted.
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142 (5)
1019 Liver Atrophy and Regeneration in Non-Cirrhotic Portal Vein Thrombosis: Effect of Surgical Shunts
- 1 May 2012
- Published by Elsevier in Gastroenterology
- Vol. 142 (5)
1019 Liver Atrophy and Regeneration in Non-Cirrhotic Portal Vein Thrombosis: Effect of Surgical Shunts
- 4 September 2009
- Published by Wiley in Medical Physics
- Vol. 36 (10) , 4359-4369
Malignant lesion segmentation in contrast‐enhanced breast MR images based on the marker‐controlled watershed
Breast tumor volume measured on MRI has been used to assess response to neoadjuvant chemotherapy. However, accurate and reproducible delineation of breast lesions can be challenging, since the lesions may have complicated topological structures and heterogeneous intensity distributions. In this article, the authors present an advanced computerized method to semiautomatically segment tumor volumes on T1‐weighted, contrast‐enhanced breast MRI. The method starts with manual selection of a region of interest (ROI) that contains the lesion to be segmented in a single image, followed by automated separation of the lesion volume from its surrounding breast parenchyma by using a unique combination of the image processing techniques including Gaussian mixture modeling and a marker‐controlled watershed transform. Explicitly, the Gaussian mixture modeling is applied to an intensity histogram of the pixels inside the ROI to distinguish the tumor class from other tissues. Based on the ROI and the intensity distribution of the tumor, internal and external markers are determined and the tumor contour is delineated using the marker‐controlled watershed transform. To obtain the tumor volume, the segmented tumor in one slice is propagated to the adjacent slice to form an ROI in that slice. The marker‐controlled watershed segmentation is then used again to obtain a tumor contour in the propagated slice. This procedure is terminated when there is no lesion in an adjacent slice. To reduce measurement variations possibly caused by the manual selection of the ROI, the segmentation result is refined based on an automatically determined ROI based on the segmented volume. The algorithm was applied to 13 patients with breast cancer, prospectively accrued prior to beginning neoadjuvant chemotherapy. Each patient had two MRI scans, a baseline MRI examination prior to commencing neoadjuvant chemotherapy and a 1 week follow‐up after receiving the first dose of neoadjuvant chemotherapy. Blinded to the computer segmentation results, two experienced radiologists manually delineated all tumors independently. The computer results were then compared with the manually generated results using the volume overlap ratio, defined as the intersection of the computer‐ and radiologist‐generated tumor volumes divided by the union of the two. The algorithm reached overall overlap ratios of and in comparison to the two manual segmentation results, respectively. The overall overlap ratio between the two radiologists’ manual segmentations was . Preliminary results suggest that the proposed algorithm is a promising method for assisting in tumor volume measurement in contrast‐enhanced breast MRI.
- 4 September 2009
- Published by Wiley in Medical Physics
- Vol. 36 (10) , 4359-4369
Malignant lesion segmentation in contrast‐enhanced breast MR images based on the marker‐controlled watershed
Breast tumor volume measured on MRI has been used to assess response to neoadjuvant chemotherapy. However, accurate and reproducible delineation of breast lesions can be challenging, since the lesions may have complicated topological structures and heterogeneous intensity distributions. In this article, the authors present an advanced computerized method to semiautomatically segment tumor volumes on T1‐weighted, contrast‐enhanced breast MRI. The method starts with manual selection of a region of interest (ROI) that contains the lesion to be segmented in a single image, followed by automated separation of the lesion volume from its surrounding breast parenchyma by using a unique combination of the image processing techniques including Gaussian mixture modeling and a marker‐controlled watershed transform. Explicitly, the Gaussian mixture modeling is applied to an intensity histogram of the pixels inside the ROI to distinguish the tumor class from other tissues. Based on the ROI and the intensity distribution of the tumor, internal and external markers are determined and the tumor contour is delineated using the marker‐controlled watershed transform. To obtain the tumor volume, the segmented tumor in one slice is propagated to the adjacent slice to form an ROI in that slice. The marker‐controlled watershed segmentation is then used again to obtain a tumor contour in the propagated slice. This procedure is terminated when there is no lesion in an adjacent slice. To reduce measurement variations possibly caused by the manual selection of the ROI, the segmentation result is refined based on an automatically determined ROI based on the segmented volume. The algorithm was applied to 13 patients with breast cancer, prospectively accrued prior to beginning neoadjuvant chemotherapy. Each patient had two MRI scans, a baseline MRI examination prior to commencing neoadjuvant chemotherapy and a 1 week follow‐up after receiving the first dose of neoadjuvant chemotherapy. Blinded to the computer segmentation results, two experienced radiologists manually delineated all tumors independently. The computer results were then compared with the manually generated results using the volume overlap ratio, defined as the intersection of the computer‐ and radiologist‐generated tumor volumes divided by the union of the two. The algorithm reached overall overlap ratios of and in comparison to the two manual segmentation results, respectively. The overall overlap ratio between the two radiologists’ manual segmentations was . Preliminary results suggest that the proposed algorithm is a promising method for assisting in tumor volume measurement in contrast‐enhanced breast MRI.
- 1 July 2009
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 252 (1) , 263-272
Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non–Small Cell Lung Cancer
Our findings will help reveal variations in the unidimensional, bidimensional, and volumetric measurements on modern CT scans and thus be valuable in detecting biologically relevant tumor changes i... PurposeTo evaluate the variability of tumor unidimensional, bidimensional, and volumetric measurements on same-day repeat computed tomographic (CT) scans in patients with non–small cell lung cancer...
- 1 July 2009
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 252 (1) , 263-272
Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non–Small Cell Lung Cancer
Our findings will help reveal variations in the unidimensional, bidimensional, and volumetric measurements on modern CT scans and thus be valuable in detecting biologically relevant tumor changes i... PurposeTo evaluate the variability of tumor unidimensional, bidimensional, and volumetric measurements on same-day repeat computed tomographic (CT) scans in patients with non–small cell lung cancer...
- Open Access
- 21 January 2009
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (2) , 239-249
Imaging Surrogates of Tumor Response to Therapy: Anatomic and Functional Biomarkers
This article addresses the current status of quantitative imaging as a surrogate biomarker for the assessment of tumor response to therapy with non–small cell lung cancer as an example. In addition, the article discusses the limitations of conventional response criteria in the new era of molecular-targeted agents for cancer treatment; the increasing need for more accurate and early response-assessment methods, particularly for volumetric CT; new tumor-specific radiotracers and molecular imaging technologies; and the future applications of molecular imaging with PET for studying various features of cancer metabolism, endocrine status, hypoxia, and oncofetal and differentiation antigens.
- 21 January 2009
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (2) , 239-249
Open AccessImaging Surrogates of Tumor Response to Therapy: Anatomic and Functional Biomarkers
This article addresses the current status of quantitative imaging as a surrogate biomarker for the assessment of tumor response to therapy with non–small cell lung cancer as an example. In addition, the article discusses the limitations of conventional response criteria in the new era of molecular-targeted agents for cancer treatment; the increasing need for more accurate and early response-assessment methods, particularly for volumetric CT; new tumor-specific radiotracers and molecular imaging technologies; and the future applications of molecular imaging with PET for studying various features of cancer metabolism, endocrine status, hypoxia, and oncofetal and differentiation antigens.
- 13 December 2006
- Published by Wiley in Medical Physics
- Vol. 34 (1) , 55-62
Automated matching and segmentation of lymphoma on serial CT examinations
- 13 December 2006
- Published by Wiley in Medical Physics
- Vol. 34 (1) , 55-62
Automated matching and segmentation of lymphoma on serial CT examinations
- 1 December 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (3) , 892-898
Lung Cancer: Computerized Quantification of Tumor Response—Initial Results
To prospectively quantify tumor response or progression in patients with lung cancer by using thin-section computed tomography (CT) and a semiautomated algorithm to calculate tumor volume and other parameter values. This HIPAA-compliant study was institutional review board approved; informed patient consent was waived. CT scans of 15 measurable non-small cell lung cancers (in five men and 10 women; mean age, 64 years; range, 38-78 years) before and after gefitinib treatment were analyzed. A semiautomated three-dimensional lung cancer segmentation algorithm was developed and applied to each tumor at baseline and follow-up. The computer calculated the greatest diameter (unidimensional measurement), the product of the greatest diameter and the greatest perpendicular diameter (bidimensional measurement), and the volume of each tumor. Exact McNemar tests were used to analyze differences in the percentage change calculated with different measurement techniques. The computer accurately segmented 14 of the 15 tumors. One paramediastinal tumor required manual separation from the mediastinum. Eleven (73%) of the 15 patients had an absolute change in tumor volume of at least 20%, compared with one (7%) and four (27%) patients who had similar changes in unscaled unidimensional (P < .01) and bidimensional (P = .04) tumor measurements, respectively. Seven (47%) patients had an absolute change in tumor volume of at least 30%. In contrast, at unscaled analysis, no patients at unidimensional measurement (P = .02) and two (13%) patients at bidimensional measurement (P = .06) had a change of at least 30%. Compared with the unidimensional and bidimensional techniques, semiautomated tumor segmentation enabled the identification of a larger number of patients with absolute changes in tumor volume of at least 20% and 30%.
- 1 December 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (3) , 892-898
Lung Cancer: Computerized Quantification of Tumor Response—Initial Results
To prospectively quantify tumor response or progression in patients with lung cancer by using thin-section computed tomography (CT) and a semiautomated algorithm to calculate tumor volume and other parameter values. This HIPAA-compliant study was institutional review board approved; informed patient consent was waived. CT scans of 15 measurable non-small cell lung cancers (in five men and 10 women; mean age, 64 years; range, 38-78 years) before and after gefitinib treatment were analyzed. A semiautomated three-dimensional lung cancer segmentation algorithm was developed and applied to each tumor at baseline and follow-up. The computer calculated the greatest diameter (unidimensional measurement), the product of the greatest diameter and the greatest perpendicular diameter (bidimensional measurement), and the volume of each tumor. Exact McNemar tests were used to analyze differences in the percentage change calculated with different measurement techniques. The computer accurately segmented 14 of the 15 tumors. One paramediastinal tumor required manual separation from the mediastinum. Eleven (73%) of the 15 patients had an absolute change in tumor volume of at least 20%, compared with one (7%) and four (27%) patients who had similar changes in unscaled unidimensional (P < .01) and bidimensional (P = .04) tumor measurements, respectively. Seven (47%) patients had an absolute change in tumor volume of at least 30%. In contrast, at unscaled analysis, no patients at unidimensional measurement (P = .02) and two (13%) patients at bidimensional measurement (P = .06) had a change of at least 30%. Compared with the unidimensional and bidimensional techniques, semiautomated tumor segmentation enabled the identification of a larger number of patients with absolute changes in tumor volume of at least 20% and 30%.
- 1 October 2006
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (10) , 753-762
Shape-Constraint Region Growing for Delineation of Hepatic Metastases on Contrast-Enhanced Computed Tomograph Scans
The objectives of this study were to develop a shape-constraint region-growing algorithm to automatically delineate liver metastases on computed tomography images and to compare automated tumor measurements with those outlined manually by radiologists. The algorithm starts with a manual selection of a seed lesion region of interest (ROI). Based on intensity distributions of the seed ROI and the liver parenchyma, several parameters are computed and used to adaptively guide the region growing. To prevent the region growing from leaking into surrounding tissues of similar characteristics, specific shape constraints, including a local shape, a global shape, and a gravity-shift index, are developed to jointly control the iteration of the region growing. The algorithm was applied to 59 lesions in 14 patients with liver metastases. The maximal diameter (unidimension), the product of the maximal and maximal perpendicular diameters (bidimension), and the area in the axial plane were calculated for each of the segmented lesions. Three independent radiologists manually measured all the lesions once, and one of the radiologists measured each lesion 3 times. For each measurement, the concordance correlation coefficient (CCC) was used to assess the pairwise agreement between the computer and the different radiologists, and the overall concordance correlation coefficient (OCCC) was used to assess the agreement between the computer and the multiple radiologists and between the one radiologist's 3 readings. Fifty-three of 59 (89.8%) lesions in 14 patients with liver metastases were successfully segmented using this algorithm. The algorithm achieved a median accuracy of 88.0%. CCCs/OCCCs ranged from 0.943 to 0.999 with 95% confidence intervals. High accuracy and CCCs/OCCCs suggested that measurements made by the computer were very similar to those made by the radiologists.
- 1 October 2006
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (10) , 753-762
Shape-Constraint Region Growing for Delineation of Hepatic Metastases on Contrast-Enhanced Computed Tomograph Scans
The objectives of this study were to develop a shape-constraint region-growing algorithm to automatically delineate liver metastases on computed tomography images and to compare automated tumor measurements with those outlined manually by radiologists. The algorithm starts with a manual selection of a seed lesion region of interest (ROI). Based on intensity distributions of the seed ROI and the liver parenchyma, several parameters are computed and used to adaptively guide the region growing. To prevent the region growing from leaking into surrounding tissues of similar characteristics, specific shape constraints, including a local shape, a global shape, and a gravity-shift index, are developed to jointly control the iteration of the region growing. The algorithm was applied to 59 lesions in 14 patients with liver metastases. The maximal diameter (unidimension), the product of the maximal and maximal perpendicular diameters (bidimension), and the area in the axial plane were calculated for each of the segmented lesions. Three independent radiologists manually measured all the lesions once, and one of the radiologists measured each lesion 3 times. For each measurement, the concordance correlation coefficient (CCC) was used to assess the pairwise agreement between the computer and the different radiologists, and the overall concordance correlation coefficient (OCCC) was used to assess the agreement between the computer and the multiple radiologists and between the one radiologist's 3 readings. Fifty-three of 59 (89.8%) lesions in 14 patients with liver metastases were successfully segmented using this algorithm. The algorithm achieved a median accuracy of 88.0%. CCCs/OCCCs ranged from 0.943 to 0.999 with 95% confidence intervals. High accuracy and CCCs/OCCCs suggested that measurements made by the computer were very similar to those made by the radiologists.
- 1 September 2006
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 30 (5) , 777-783
Automated Quantification of Body Fat Distribution on Volumetric Computed Tomography
To develop a computerized method to automatically quantify visceral and subcutaneous fat distribution within the abdomen and pelvis on volumetric computed tomographic (CT) images. Given the slices of interest, the algorithm automatically delineates a contour that separates the visceral fat from the subcutaneous fat on each slice. Explicitly, starting with extraction of the body perimeter, radii at a fixed angle increment are drawn from the perimeter to the center of the body. Along each radius, intensity profile is analyzed to determine the point on the subcutaneous fat layer that is closest to the body center (inner point). All inner points are then connected to form an inner contour, and a specific smoothing algorithm is subsequently applied to correct suboptimal results. Pixels having HU values between -190 and -30 are considered fat pixels. This procedure is repeated on each of the slices of interest. The visceral and subcutaneous fat volumes computed automatically were compared with those after the radiologist's adjustments. Ratios of volumetric visceral fat-to-total fat and visceral fat-to-subcutaneous fat were compared on average and with single-slice measurements obtained at L4 and L5 vertebral body levels. Subcutaneous and visceral fat were automatically segmented using this algorithm on 419 axial CT slices in 9 CT scans (patients) within the abdomen and pelvis. The overall average percentage difference between the automated segmentation and the segmentation edited by the radiologist were 1.54% for the visceral fat and 0.65% for the subcutaneous fat. Preliminary results have shown that total compartmental fat, including visceral and subcutaneous fat, can be automatically and accurately segmented on volumetric CT.
- 1 September 2006
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 30 (5) , 777-783
Automated Quantification of Body Fat Distribution on Volumetric Computed Tomography
To develop a computerized method to automatically quantify visceral and subcutaneous fat distribution within the abdomen and pelvis on volumetric computed tomographic (CT) images. Given the slices of interest, the algorithm automatically delineates a contour that separates the visceral fat from the subcutaneous fat on each slice. Explicitly, starting with extraction of the body perimeter, radii at a fixed angle increment are drawn from the perimeter to the center of the body. Along each radius, intensity profile is analyzed to determine the point on the subcutaneous fat layer that is closest to the body center (inner point). All inner points are then connected to form an inner contour, and a specific smoothing algorithm is subsequently applied to correct suboptimal results. Pixels having HU values between -190 and -30 are considered fat pixels. This procedure is repeated on each of the slices of interest. The visceral and subcutaneous fat volumes computed automatically were compared with those after the radiologist's adjustments. Ratios of volumetric visceral fat-to-total fat and visceral fat-to-subcutaneous fat were compared on average and with single-slice measurements obtained at L4 and L5 vertebral body levels. Subcutaneous and visceral fat were automatically segmented using this algorithm on 419 axial CT slices in 9 CT scans (patients) within the abdomen and pelvis. The overall average percentage difference between the automated segmentation and the segmentation edited by the radiologist were 1.54% for the visceral fat and 0.65% for the subcutaneous fat. Preliminary results have shown that total compartmental fat, including visceral and subcutaneous fat, can be automatically and accurately segmented on volumetric CT.