Lawrence H. Schwartz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lawrence H. Schwartz has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Binsheng Zhao
Department of Radiology, Columbia University Medical Center, New York, NY
3 shared publications - David M. Panicek
Department of Radiology Memorial Sloan Kettering Cancer Center New York NY
3 shared publications Alex Smith
2 shared publicationsLiang Wang
Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10021
2 shared publications- Andrew D. Zelenetz
Memorial Sloan Kettering Cancer Center New York New York USA
1 shared publication David M Panicek
1 shared publication
Latest Publications
- 1 January 2009
- Published by Elsevier in European Journal of Cancer
- Vol. 45 (2) , 261-267
Evaluation of lymph nodes with RECIST 1.1
- 1 January 2009
- Published by Elsevier in European Journal of Cancer
- Vol. 45 (2) , 261-267
Evaluation of lymph nodes with RECIST 1.1
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 3062-3065
An Automatic Method for Ground Glass Opacity Nodule Detection and Segmentation from CT Studies
Ground glass opacity (GGO) is defined as hazy increased attenuation within a lung that is not associated with obscured underlying vessels. Since pure (non-solid) or mixed (partially solid) GGO at the thin-section CT are more likely to be malignant than those with solid opacity, early detection and treatment of GGO can improve a prognosis of lung cancer. However, due to indistinct boundaries and inter-or intra-observer variation, consistent manual detection and segmentation of GGO have proved to be problematic. In this paper, we propose a novel method for automatic detection and segmentation of GGO from chest CT images. For GGO detection, we develop a classifier by boosting k-nearest neighbor (k-NN), whose distance measure is the Euclidean distance between the nonparametric density estimates of two regions. The detected GGO region is then automatically segmented by analyzing the 3D texture likelihood map of the region. We applied our method to clinical chest CT volumes containing 10 GGO nodules. The proposed method detected all of the 10 nodules with only one false positive nodule. We also present the statistical validation of the proposed classifier for automatic GGO detection as well as very promising results for automatic GGO segmentation. The proposed method provides a new powerful tool for automatic detection as well as accurate and reproducible segmentation of GGO
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 3062-3065
An Automatic Method for Ground Glass Opacity Nodule Detection and Segmentation from CT Studies
Ground glass opacity (GGO) is defined as hazy increased attenuation within a lung that is not associated with obscured underlying vessels. Since pure (non-solid) or mixed (partially solid) GGO at the thin-section CT are more likely to be malignant than those with solid opacity, early detection and treatment of GGO can improve a prognosis of lung cancer. However, due to indistinct boundaries and inter-or intra-observer variation, consistent manual detection and segmentation of GGO have proved to be problematic. In this paper, we propose a novel method for automatic detection and segmentation of GGO from chest CT images. For GGO detection, we develop a classifier by boosting k-nearest neighbor (k-NN), whose distance measure is the Euclidean distance between the nonparametric density estimates of two regions. The detected GGO region is then automatically segmented by analyzing the 3D texture likelihood map of the region. We applied our method to clinical chest CT volumes containing 10 GGO nodules. The proposed method detected all of the 10 nodules with only one false positive nodule. We also present the statistical validation of the proposed classifier for automatic GGO detection as well as very promising results for automatic GGO segmentation. The proposed method provides a new powerful tool for automatic detection as well as accurate and reproducible segmentation of GGO
- 21 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (7Part1) , 2452-2460
Marker‐controlled watershed for lymphoma segmentation in sequential CT images
Segmentation of lymphoma containing lymph nodes is a difficult task because of multiple variables associated with the tumor's location, intensity distribution, and contrast to its surrounding tissues. In this paper, we present a reliable and practical marker‐controlled watershed algorithm for semi‐automated segmentation of lymphoma in sequential CT images. Robust determination of internal and external markers is the key to successful use of the marker‐controlled watershed transform in the segmentation of lymphoma and is the focus of this work. The external marker in our algorithm is the circle enclosing the lymphoma in a single slice. The internal marker, however, is determined automatically by combining techniques including Canny edge detection, thresholding, morphological operation, and distance map estimation. To obtain tumor volume, the segmented lymphoma in the current slice needs to be propagated to the adjacent slice to help determine the external and internal markers for delineation of the lymphoma in that slice. The algorithm was applied to 29 lymphomas (size range, in diameter; mean, ) in nine patients. A blinded radiologist manually delineated all lymphomas on all slices. The manual result served as the “gold standard” for comparison. Several quantitative methods were applied to objectively evaluate the performance of the segmentation algorithm. The algorithm received a mean overlap, overestimation, and underestimation ratios of 83.2%, 13.5%, and 5.5%, respectively. The mean average boundary distance and Hausdorff boundary distance were 0.7 and . Preliminary results have shown the potential of this computer algorithm to allow reliable segmentation and quantification of lymphomas on sequential CT images.
- 21 June 2006
- Published by Wiley in Medical Physics
- Vol. 33 (7Part1) , 2452-2460
Marker‐controlled watershed for lymphoma segmentation in sequential CT images
Segmentation of lymphoma containing lymph nodes is a difficult task because of multiple variables associated with the tumor's location, intensity distribution, and contrast to its surrounding tissues. In this paper, we present a reliable and practical marker‐controlled watershed algorithm for semi‐automated segmentation of lymphoma in sequential CT images. Robust determination of internal and external markers is the key to successful use of the marker‐controlled watershed transform in the segmentation of lymphoma and is the focus of this work. The external marker in our algorithm is the circle enclosing the lymphoma in a single slice. The internal marker, however, is determined automatically by combining techniques including Canny edge detection, thresholding, morphological operation, and distance map estimation. To obtain tumor volume, the segmented lymphoma in the current slice needs to be propagated to the adjacent slice to help determine the external and internal markers for delineation of the lymphoma in that slice. The algorithm was applied to 29 lymphomas (size range, in diameter; mean, ) in nine patients. A blinded radiologist manually delineated all lymphomas on all slices. The manual result served as the “gold standard” for comparison. Several quantitative methods were applied to objectively evaluate the performance of the segmentation algorithm. The algorithm received a mean overlap, overestimation, and underestimation ratios of 83.2%, 13.5%, and 5.5%, respectively. The mean average boundary distance and Hausdorff boundary distance were 0.7 and . Preliminary results have shown the potential of this computer algorithm to allow reliable segmentation and quantification of lymphomas on sequential CT images.
- 17 November 2005
- Published by Wiley in Medical Physics
- Vol. 32 (12) , 3699-3706
Liver segmentation for CT images using GVF snake
Accurate liver segmentation on computed tomography(CT)images is a challenging task especially at sites where surrounding tissues (e.g., stomach, kidney) have densities similar to that of the liver and lesions reside at the liver edges. We have developed a method for semiautomatic delineation of the liver contours on contrast-enhanced CTimages. The method utilizes a snake algorithm with a gradient vector flow (GVF) field as its external force. To improve the performance of the GVF snake in the segmentation of the liver contour, an edge map was obtained with a Canny edge detector, followed by modifications using a liver template and a concavity removal algorithm. With the modified edge map, for which unwanted edges inside the liver were eliminated, the GVF field was computed and an initial liver contour was formed. The snake algorithm was then applied to obtain the actual liver contour. This algorithm was extended to segment the liver volume in a slice-by-slice fashion, where the result of the preceding slice constrained the segmentation of the adjacent slice. 551 two-dimensional liverimages from 20 volumetric images with colorectal metastases spreading throughout the livers were delineated using this method, and also manually by a radiologist for evaluation. The difference ratio, which is defined as the percentage ratio of mismatching volume between the computer and the radiologist’s results, ranged from 2.9% to 7.6% with a median value of 5.3%.
- 17 November 2005
- Published by Wiley in Medical Physics
- Vol. 32 (12) , 3699-3706
Liver segmentation for CT images using GVF snake
Accurate liver segmentation on computed tomography(CT)images is a challenging task especially at sites where surrounding tissues (e.g., stomach, kidney) have densities similar to that of the liver and lesions reside at the liver edges. We have developed a method for semiautomatic delineation of the liver contours on contrast-enhanced CTimages. The method utilizes a snake algorithm with a gradient vector flow (GVF) field as its external force. To improve the performance of the GVF snake in the segmentation of the liver contour, an edge map was obtained with a Canny edge detector, followed by modifications using a liver template and a concavity removal algorithm. With the modified edge map, for which unwanted edges inside the liver were eliminated, the GVF field was computed and an initial liver contour was formed. The snake algorithm was then applied to obtain the actual liver contour. This algorithm was extended to segment the liver volume in a slice-by-slice fashion, where the result of the preceding slice constrained the segmentation of the adjacent slice. 551 two-dimensional liverimages from 20 volumetric images with colorectal metastases spreading throughout the livers were delineated using this method, and also manually by a radiologist for evaluation. The difference ratio, which is defined as the percentage ratio of mismatching volume between the computer and the radiologist’s results, ranged from 2.9% to 7.6% with a median value of 5.3%.
- 1 October 2003
- Vol. 9 (12) , 4318-23
Variability in response assessment in solid tumors: effect of number of lesions chosen for measurement.
This study was performed to systematically evaluate the variability in tumor response assessments that occurs depending on how many tumor deposits are selected for measurement at imaging. The two largest perpendicular diameters of all tumor deposits in 36 patients were measured on computed tomography scans obtained at baseline and first posttherapy follow-up. A computerized modeling analysis of those data was performed to determine each patient's therapeutic response category assignment for every possible number of lesions in a grouping. The variance in the sum of measurements of these lesion groupings was calculated, and the frequency of response assessment categories was plotted against the number of lesions. The computerized analysis of the resultant 1,833,821 possible combinations of tumor deposits showed that when six lesions were measured bidimensionally and four lesions were measured undimensionally, the average variance decreased by 90%. The number of different response assessment categories into which a patient was assigned decreased with increasing lesion grouping size. When six or more lesions were measured bidimensionally, 9% of all possible lesion groupings still fell into a second response category, reflecting the effect of which particular lesions are chosen for measurement. Measuring larger numbers of lesions will decrease the variance. In this population, the variance decreased by at least 90% when six or more lesions were measured bidimensionally. Further confirmatory studies with larger series of patients are warranted before adopting this number as a criterion in clinical trials for assessing the activity of antineoplastic therapies.
- 1 October 2003
- Vol. 9 (12) , 4318-23
Variability in response assessment in solid tumors: effect of number of lesions chosen for measurement.
This study was performed to systematically evaluate the variability in tumor response assessments that occurs depending on how many tumor deposits are selected for measurement at imaging. The two largest perpendicular diameters of all tumor deposits in 36 patients were measured on computed tomography scans obtained at baseline and first posttherapy follow-up. A computerized modeling analysis of those data was performed to determine each patient's therapeutic response category assignment for every possible number of lesions in a grouping. The variance in the sum of measurements of these lesion groupings was calculated, and the frequency of response assessment categories was plotted against the number of lesions. The computerized analysis of the resultant 1,833,821 possible combinations of tumor deposits showed that when six lesions were measured bidimensionally and four lesions were measured undimensionally, the average variance decreased by 90%. The number of different response assessment categories into which a patient was assigned decreased with increasing lesion grouping size. When six or more lesions were measured bidimensionally, 9% of all possible lesion groupings still fell into a second response category, reflecting the effect of which particular lesions are chosen for measurement. Measuring larger numbers of lesions will decrease the variance. In this population, the variance decreased by at least 90% when six or more lesions were measured bidimensionally. Further confirmatory studies with larger series of patients are warranted before adopting this number as a criterion in clinical trials for assessing the activity of antineoplastic therapies.
- Open Access
Response assessment classification in patients with advanced renal cell carcinoma treated on clinical trials
BACKGROUND The objective of the current study was to evaluate the effect on response assessment classification in patients with metastatic renal cell carcinoma (RCC) using unidimensional (Response Evaluation Criteria in Solid Tumors) and bidimensional (World Health Organization) criteria, including or excluding measurements of the primary renal tumor and using a new index to compensate for the disproportionate effect of large renal tumors relative to their metastases. METHODS Fifty-three imaging studies involving a total of 44 patients with metastatic RCC who were treated on clinical trials of interferon-α analogue and/or thalidomide were reviewed retrospectively. The best overall response assessment and progression free survival were calculated with both unidimensional and bidimensional tumor measurements. Patients were then stratified into two groups: patients with primary renal tumors in situ and patients who underwent resection of their primary renal tumors. The best overall response and the time to disease progression were calculated based on the sum of measurements (conventional methodology), both including and excluding the primary tumor. A new method of response assessment, the ‘normalized lesion index’, which equalizes the differences in tumor size for an individual patient, was evaluated and compared with the conventional response assessment. RESULTS There was an 11% disagreement rate in the best overall response assessment between unidimensional and bidimensional measurements. The time to progression was 9.2 months measured unidimensionally, compared with 6.4 months assessed bidimensionally. In the group of patients who had primary renal tumors in situ, using the conventional sum of measurements method, the apparent time to progression was an average of 4.2 months longer compared with measurements that did not include the primary renal tumor. The use of the normalized lesion index method resulted in an improved concordance in best overall response assessments and similar time to progression assessments when the primary renal tumor was included compared with patients who did not have primary renal tumors in situ. CONCLUSIONS The use of unidimensional measurements in RCC therapy assessment results in significantly different time to progression classification compared with the use of bidimensional measurements. Response assessment classification in patients with RCC is affected by the exclusion or inclusion of measurements of the primary renal tumor. The normalized lesion index warrants further study in assessing response in patients with metastatic RCC and other solid tumor malignancies that often show substantial differences in sizes of measurable lesions. Cancer 2003. © 2003 American Cancer Society. DOI 10.1002/cncr.11712
Open AccessResponse assessment classification in patients with advanced renal cell carcinoma treated on clinical trials
BACKGROUND The objective of the current study was to evaluate the effect on response assessment classification in patients with metastatic renal cell carcinoma (RCC) using unidimensional (Response Evaluation Criteria in Solid Tumors) and bidimensional (World Health Organization) criteria, including or excluding measurements of the primary renal tumor and using a new index to compensate for the disproportionate effect of large renal tumors relative to their metastases. METHODS Fifty-three imaging studies involving a total of 44 patients with metastatic RCC who were treated on clinical trials of interferon-α analogue and/or thalidomide were reviewed retrospectively. The best overall response assessment and progression free survival were calculated with both unidimensional and bidimensional tumor measurements. Patients were then stratified into two groups: patients with primary renal tumors in situ and patients who underwent resection of their primary renal tumors. The best overall response and the time to disease progression were calculated based on the sum of measurements (conventional methodology), both including and excluding the primary tumor. A new method of response assessment, the ‘normalized lesion index’, which equalizes the differences in tumor size for an individual patient, was evaluated and compared with the conventional response assessment. RESULTS There was an 11% disagreement rate in the best overall response assessment between unidimensional and bidimensional measurements. The time to progression was 9.2 months measured unidimensionally, compared with 6.4 months assessed bidimensionally. In the group of patients who had primary renal tumors in situ, using the conventional sum of measurements method, the apparent time to progression was an average of 4.2 months longer compared with measurements that did not include the primary renal tumor. The use of the normalized lesion index method resulted in an improved concordance in best overall response assessments and similar time to progression assessments when the primary renal tumor was included compared with patients who did not have primary renal tumors in situ. CONCLUSIONS The use of unidimensional measurements in RCC therapy assessment results in significantly different time to progression classification compared with the use of bidimensional measurements. Response assessment classification in patients with RCC is affected by the exclusion or inclusion of measurements of the primary renal tumor. The normalized lesion index warrants further study in assessing response in patients with metastatic RCC and other solid tumor malignancies that often show substantial differences in sizes of measurable lesions. Cancer 2003. © 2003 American Cancer Society. DOI 10.1002/cncr.11712
- 1 May 2003
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 27 (3) , 307-314
Breath-Hold Magnetic Resonance Cholangiopancreatography in the Evaluation of Malignant Pancreaticobiliary Obstruction
This study was designed to determine the effectiveness of magnetic resonance cholangiopancreatography (MRCP) using a breath-hold single-shot fast spin echo (SSFSE) technique in imaging patients with malignant biliary and/or pancreatic duct obstruction. One hundred thirty-one breath-hold MRCP studies in patients with malignant pancreatic and/or biliary obstruction were evaluated. Pathologic diagnoses included pancreatic cancer, biliary malignancy, gallbladder carcinoma, hepatic neoplasms, malignant lymphadenopathy, and ampullary carcinoma. Two observers independently reviewed the images in a blinded fashion to assess the level of obstruction and the site of underlying tumor. The level of obstruction was correctly identified in 104 of 131 cases (79%) by observer 1 and in 107 of 131 cases (82%) by observer 2. The site of underlying tumor was correctly identified in 113 of 131 cases (86%) by observer 1 and in 110 of 131 cases (84%) by observer 2. Magnetic resonance cholangiopancreatography utilizing the SSFSE technique can accurately assess the level of obstruction and the site of underlying tumor in patients with malignant pancreaticobiliary obstruction, without the risks of cholangiography. This MRCP technique allows for visualization of intra- and extraductal anatomy and pathology.
- 1 May 2003
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 27 (3) , 307-314
Breath-Hold Magnetic Resonance Cholangiopancreatography in the Evaluation of Malignant Pancreaticobiliary Obstruction
This study was designed to determine the effectiveness of magnetic resonance cholangiopancreatography (MRCP) using a breath-hold single-shot fast spin echo (SSFSE) technique in imaging patients with malignant biliary and/or pancreatic duct obstruction. One hundred thirty-one breath-hold MRCP studies in patients with malignant pancreatic and/or biliary obstruction were evaluated. Pathologic diagnoses included pancreatic cancer, biliary malignancy, gallbladder carcinoma, hepatic neoplasms, malignant lymphadenopathy, and ampullary carcinoma. Two observers independently reviewed the images in a blinded fashion to assess the level of obstruction and the site of underlying tumor. The level of obstruction was correctly identified in 104 of 131 cases (79%) by observer 1 and in 107 of 131 cases (82%) by observer 2. The site of underlying tumor was correctly identified in 113 of 131 cases (86%) by observer 1 and in 110 of 131 cases (84%) by observer 2. Magnetic resonance cholangiopancreatography utilizing the SSFSE technique can accurately assess the level of obstruction and the site of underlying tumor in patients with malignant pancreaticobiliary obstruction, without the risks of cholangiography. This MRCP technique allows for visualization of intra- and extraductal anatomy and pathology.
- 1 January 1998
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 65 (1) , 193-197
MRI as an Alternative to CT-Guided Biopsy of Adrenal Masses in Patients With Lung Cancer
- 1 January 1998
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 65 (1) , 193-197
MRI as an Alternative to CT-Guided Biopsy of Adrenal Masses in Patients With Lung Cancer