LZLei Zhu

Lei Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lei Zhu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Scatter correction for cone‐beam CT in radiation therapy

    by Lei Zhu, Yaoqin Xie, Jing Wang, Lei Xing

    Cone‐beam CT (CBCT) is being increasingly used in modern radiation therapy for patient setup and adaptive replanning. However, due to the large volume of x‐ray illumination, scatter becomes a rather serious problem and is considered as one of the fundamental limitations of CBCT image quality. Many scatter correction algorithms have been proposed in literature, while a standard practical solution still remains elusive. In radiation therapy, the same patient is scanned repetitively during a course of treatment, a natural question to ask is whether one can obtain the scatter distribution on the first day of treatment and then use the data for scatter correction in the subsequent scans on different days. To realize this scatter removal scheme, two technical pieces must be in place: (i) A strategy to obtain the scatter distribution in on‐board CBCT imaging and (ii) a method to spatially match a prior scatter distribution with the on‐treatment CBCT projection data for scatter subtraction. In this work, simple solutions to the two problems are provided. A partially blocked CBCT is used to extract the scatter distribution. The x‐ray beam blocker has a strip pattern, such that partial volume can still be accurately reconstructed and the whole‐field scatter distribution can be estimated from the detected signals in the shadow regions using interpolation/extrapolation. In the subsequent scans, the patient transformation is determined using a rigid registration of the conventional CBCT and the prior partial CBCT. From the derived patient transformation, the measured scatter is then modified to adapt the new on‐treatment patient geometry for scatter correction. The proposed method is evaluated using physical experiments on a clinical CBCT system. On the Catphan©600 phantom, the errors in Hounsfield unit (HU) in the selected regions of interest are reduced from about 350 to below ; on an anthropomorphic phantom, the error is reduced from 15.7% to 5.4%. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy.


  • Search for IMRT inverse plans with piecewise constant fluence maps using compressed sensing techniques

    by Lei Zhu, Lei Xing

    An intensity‐modulated radiation therapy (IMRT) field is composed of a series of segmented beams. It is practically important to reduce the number of segments while maintaining the conformality of the final dose distribution. In this article, the authors quantify the complexity of an IMRT fluence map by introducing the concept of sparsity of fluence maps and formulate the inverse planning problem into a framework of compressing sensing. In this approach, the treatment planning is modeled as a multiobjective optimization problem, with one objective on the dose performance and the other on the sparsity of the resultant fluence maps. A Pareto frontier is calculated, and the achieved dose distributions associated with the Pareto efficient points are evaluated using clinical acceptance criteria. The clinically acceptable dose distribution with the smallest number of segments is chosen as the final solution. The method is demonstrated in the application of fixed‐gantry IMRT on a prostate patient. The result shows that the total number of segments is greatly reduced while a satisfactory dose distribution is still achieved. With the focus on the sparsity of the optimal solution, the proposed method is distinct from the existing beamlet‐ or segment‐based optimization algorithms.


  • Noise suppression in scatter correction for cone‐beam CT

    by Lei Zhu, Jing Wang, Lei Xing

    Scatter correction is crucial to the quality of reconstructed images in x‐ray cone‐beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The high‐frequency scatter noise remains in the projection images even after a perfect scatter correction. In this paper, using a clinical CBCT system and a measurement‐based scatter correction, the authors show that a scatter correction alone does not provide satisfactory image quality and the loss of the contrast‐to‐noise ratio (CNR) of the scatter corrected image may overwrite the benefit of scatter removal. To circumvent the problem and truly gain from scatter correction, an effective scatter noise suppression method must be in place. They analyze the noise properties in the projections after scatter correction and propose to use a penalized weighted least‐squares (PWLS) algorithm to reduce the noise in the reconstructed images. Experimental results on an evaluation phantom (Catphan©600) show that the proposed algorithm further reduces the reconstruction error in a scatter corrected image from 10.6% to 1.7% and increases the CNR by a factor of 3.6. Significant image quality improvement is also shown in the results on an anthropomorphic phantom, in which the global noise level is reduced and the local streaking artifacts around bones are suppressed.


  • Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments

    by Lei Zhu, Louis Lee, Yunzhi Ma, Yinyu Ye, Rafe Mazzeo, Lei Xing

    Currently, there are two types of treatment planning algorithms for intensity modulated radiation therapy (IMRT). The beamlet-based algorithm generates beamlet intensity maps with high complexity, resulting in large numbers of segments in the delivery after a leaf-sequencing algorithm is applied. The segment-based direct aperture optimization (DAO) algorithm includes the physical constraints of the deliverable apertures in the calculation, and achieves a conformal dose distribution using a small number of segments. However, the number of segments is pre-fixed in most of the DAO approaches, and the typical random search scheme in the optimization is computationally intensive. A regularization-based algorithm is proposed to overcome the drawbacks of the DAO method. Instead of smoothing the beamlet intensity maps as in many existing methods, we include a total-variation term in the optimization objective function to reduce the number of signal levels of the beam intensity maps. An aperture rectification algorithm is then applied to generate a significantly reduced number of deliverable apertures. As compared to the DAO algorithm, our method has an efficient form of quadratic optimization, with an additional advantage of optimizing field-specific numbers of segments based on the modulation complexity. The proposed approach is evaluated using two clinical cases. Under the condition that the clinical acceptance criteria of the treatment plan are satisfied, for the prostate patient, the total number of segments for five fields is reduced from 61 using the Eclipse planning system to 35 using the proposed algorithm; for the head and neck patient, the total number of segments for seven fields is reduced from 107 to 28. The head and neck result is also compared to that using an equal number of four segments for each field. The comparison shows that using field-specific numbers of segments achieves a much improved dose distribution.


  • Open Access

    An Efficient Estimation Method for Reducing the Axial Intensity Drop in Circular Cone‐Beam CT

    by Lei Zhu, Jared Starman, Rebecca Fahrig

    Reconstruction algorithms for circular cone‐beam (CB) scans have been extensively studied in the literature. Since insufficient data are measured, an exact reconstruction is impossible for such a geometry. If the reconstruction algorithm assumes zeros for the missing data, such as the standard FDK algorithm, a major type of resulting CB artifacts is the intensity drop along the axial direction. Many algorithms have been proposed to improve image quality when faced with this problem of data missing; however, development of an effective and computationally efficient algorithm remains a major challenge. In this work, we propose a novel method for estimating the unmeasured data and reducing the intensity drop artifacts. Each CB projection is analyzed in the Radon space via Grangeat_s first derivative. Assuming the CB projection is taken from a parallel beam geometry, we extract those data that reside in the unmeasured region of the Radon space. These data are then used as in a parallel beam geometry to calculate a correction term, which is added together with Hu’s correction term to the FDK result to form a final reconstruction. More approximations are then made on the calculation of the additional term, and the final formula is implemented very efficiently. The algorithm performance is evaluated using computer simulations on analytical phantoms. The reconstruction comparison with results using other existing algorithms shows that the proposed algorithm achieves a superior performance on the reduction of axial intensity drop artifacts with a high computation efficiency.


  • A short‐scan reconstruction for cone‐beam CT using shift‐invariant FBP and equal weighting

    by Lei Zhu, Sungwon Yoon, Rebecca Fahrig

    A 3D reconstruction formula has been derived for a circular cone‐beam (CB) short scan using 1D shift‐invariant filtering, CB backprojection, and equal weighting. By first converting the divergent projections to parallel projections, we analyze the circular CB data using the classic central slice theorem. The sampling density in Fourier space is investigated and 1D shift‐invariant filtering before backprojection can be used to compensate for the nonuniformity. The final formula consists of a conventional FDK reconstruction and a correction term using differential backprojection and the 1D Hilbert transform in the image domain. On a full scan, the approach reduces to the FDK algorithm, while for a short scan, the CB artifacts are suppressed by the second term. This algorithm outperforms the modified FDK algorithm with Parker's weighting, as illustrated by computer simulations and experimental results. Due to its shift‐invariant filtered‐backprojection structure, the proposed algorithm is implemented efficiently, and requires a simple adaptation of the FDK algorithm.


  • Scatter Correction Method for X-Ray CT Using Primary Modulation: Theory and Preliminary Results

    by Lei Zhu, N. Robert Bennett, Rebecca Fahrig

    An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The key hypothesis of the algorithm is that the high-frequency components of the X-ray spatial distribution do not result in strong high-frequency signals in the scatter. A calibration sheet with a checkerboard pattern of semitransparent blockers (a "primary modulator") is inserted between the X-ray source and the object. The primary distribution is partially modulated by a high-frequency function, while the scatter distribution still has dominant low-frequency components, based on the hypothesis. Filtering and demodulation techniques suffice to extract the low-frequency components of the primary and hence obtain the scatter estimation. The hypothesis was validated using Monte Carlo (MC) simulation, and the algorithm was evaluated by both MC simulations and physical experiments. Reconstructions of a software humanoid phantom suggested system parameters in the physical implementation and showed that the proposed method reduced the relative mean square error of the reconstructed image in the central region of interest from 74.2% to below 1%. In preliminary physical experiments on the standard evaluation phantom, this error was reduced from 31.8% to 2.3%, and it was also demonstrated that the algorithm has no noticeable impact on the resolution of the reconstructed image in spite of the filter-based approach. Although the proposed scatter correction technique was implemented for X-ray CT, it can also be used in other X-ray imaging applications, as long as a primary modulator can be inserted between the X-ray source and the imaged object


  • MTF measurement and a phantom study for scatter correction in CBCT using primary modulation

    by Lei Zhu, Jared Starman, N. Robert Bennett, Rebecca Fahrig

    Recently, we proposed a scatter correction methods for X-ray imaging using primary modulation. A primary modulator with spatially variant attenuating materials is inserted between the X-ray source and the object to make the scatter and part of the primary distributions strongly separated in the Fourier domain. Linear filtering and demodulation techniques suffice to extract and correct the scatter for this modified system. The method has been verified by computer simulations and preliminary experimental results. In this work, we look into a hybrid method using both primary modulation and an anti-scatter grid. The reconstructed image resolution using the proposed approach is evaluated by MTF measurements, and the scatter correction performance is also investigated by experiments on a human chest phantom. The results using the proposed hybrid method are compared with those using an antiscatter grid only. Experiments with scatter inherently suppressed using a narrowly opened collimator and an anti-scatter grid (a slot-scan geometry) were also carried out. The comparison shows that the filtering in the proposed algorithm does not impair the image resolution, and the primary modulation method can effectively suppress the scatter artifacts. In the central region of interest, the reconstruction error relative to the image obtained using a slot-scan geometry is reduced from 18.10% to 0.48% for the human chest phantom, if the primary modulation method is used.