Johanna Hortensius
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Johanna Hortensius has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
H J G Bilo
2 shared publicationsK H Groenier
2 shared publicationsN. Kleefstra
Isala Clin, Ctr Diabet, Zwolle, Netherlands
2 shared publicationsNanne Kleefstra
Diabetes Centre, Isala Clinics, Zwolle (Ms Hortensius, Dr Kleefstra, Dr Bilo)
2 shared publications- Nanne Kleefstra
Diabetes Centre, Isala Clinics, Zwolle, The Netherlands
2 shared publications R J Slingerland
2 shared publications
Latest Publications
- 1 April 2013
- Published by Springer Nature in Nederlands Tijdschrift voor Evidence Based Practice
- Vol. 11 (2) , 17-20
Zelfcontrole bij mensen met diabetes
- 1 April 2013
- Published by Springer Nature in Nederlands Tijdschrift voor Evidence Based Practice
- Vol. 11 (2) , 17-20
Zelfcontrole bij mensen met diabetes
- 1 August 2012
- Vol. 70 (6) , 287-291
What do professionals recommend regarding the frequency of self-monitoring of blood glucose?
Background: Patients' adherence to guidelines regarding self-monitoring of blood glucose (SMBG) is limited. However, there are no previous reports about the recommendations that are given in clinical practice concerning SMBG. The aim of this study was to investigate what healthcare providers recommend to insulin-treated patients with diabetes regarding frequency and timing of SMBG. Methods: In this cross-sectional descriptive study, primary care assistants, diabetes specialised nurses and doctors in the Netherlands were invited via e-mail to complete an internet survey. Results: A total of 980 (14%) professionals returned the questionnaire. Insulin pump users and patients with type 1 diabetes (T1DM) on 4 injections a day were advised to perform SMBG daily by 96% and 63% of the professionals, respectively. The majority of the professionals advised these patients to perform 3-4 measurements per day. There was less agreement on the timing (pre-and/or postprandial). Patients with type 2 diabetes (T2DM) on four injections were advised to perform SMBG less frequently. There was a wide variation in recommendations that were given to patients with T2DM on less intensive insulin regimens. Conclusion: This study investigated SMBG from a professional's perspective. A considerable and relevant variation in the recommendations about the number and timing of SMBG was observed. The most striking differences were found in patients with T2DM on less intensive insulin regimes, also with respect to the frequency of SMBG. Well-designed studies are necessary in order to give a more evidence-based advice on the basic frequency and timing of SMBG.
- 1 August 2012
- Vol. 70 (6) , 287-291
What do professionals recommend regarding the frequency of self-monitoring of blood glucose?
Background: Patients' adherence to guidelines regarding self-monitoring of blood glucose (SMBG) is limited. However, there are no previous reports about the recommendations that are given in clinical practice concerning SMBG. The aim of this study was to investigate what healthcare providers recommend to insulin-treated patients with diabetes regarding frequency and timing of SMBG. Methods: In this cross-sectional descriptive study, primary care assistants, diabetes specialised nurses and doctors in the Netherlands were invited via e-mail to complete an internet survey. Results: A total of 980 (14%) professionals returned the questionnaire. Insulin pump users and patients with type 1 diabetes (T1DM) on 4 injections a day were advised to perform SMBG daily by 96% and 63% of the professionals, respectively. The majority of the professionals advised these patients to perform 3-4 measurements per day. There was less agreement on the timing (pre-and/or postprandial). Patients with type 2 diabetes (T2DM) on four injections were advised to perform SMBG less frequently. There was a wide variation in recommendations that were given to patients with T2DM on less intensive insulin regimens. Conclusion: This study investigated SMBG from a professional's perspective. A considerable and relevant variation in the recommendations about the number and timing of SMBG was observed. The most striking differences were found in patients with T2DM on less intensive insulin regimes, also with respect to the frequency of SMBG. Well-designed studies are necessary in order to give a more evidence-based advice on the basic frequency and timing of SMBG.
- 1 April 2012
- Published by Springer Nature in Nederlands Tijdschrift voor Diabetologie
- Vol. 10 (1) , 24-25
Het gebruik van de 1e of 2e bloeddruppel bij de uitvoering van zelfcontrole
- 1 April 2012
- Published by Springer Nature in Nederlands Tijdschrift voor Diabetologie
- Vol. 10 (1) , 24-25
Het gebruik van de 1e of 2e bloeddruppel bij de uitvoering van zelfcontrole
- Open Access
- 8 March 2012
- Published by Springer Nature in BMC Public Health
- Vol. 12 (1) , 167
Perspectives of patients with type 1 or insulin-treated type 2 diabetes on self-monitoring of blood glucose: a qualitative study
Self-monitoring of blood glucose (SMBG), including self-regulation, is an important tool to achieve good glycemic control. However, many patients measure their glucose concentrations less often than is recommended. This study investigates patients' perspectives of SMBG and all relevant aspects influencing SMBG in patients with type 1 and insulin-treated type 2 diabetes.
- 8 March 2012
- Published by Springer Nature in BMC Public Health
- Vol. 12 (1) , 167
Open AccessPerspectives of patients with type 1 or insulin-treated type 2 diabetes on self-monitoring of blood glucose: a qualitative study
Self-monitoring of blood glucose (SMBG), including self-regulation, is an important tool to achieve good glycemic control. However, many patients measure their glucose concentrations less often than is recommended. This study investigates patients' perspectives of SMBG and all relevant aspects influencing SMBG in patients with type 1 and insulin-treated type 2 diabetes.
- 6 December 2011
- Published by SAGE Publications in The Diabetes Educator
- Vol. 38 (1) , 101-107
Self-Monitoring of Blood Glucose
Purpose This study investigated the advice given by diabetes educators in Europe, and the daily practice of Dutch patients with diabetes regarding the use of the first or second drop of blood and other aspects concerning self-monitoring of blood glucose (SMBG). Method During a diabetes conference in 2009, 96 European diabetes educators (including 46 Dutch educators) completed a single-item questionnaire about the use of the first or second drop of blood for glucose monitoring. A self-reported questionnaire with 20 questions about performing SMBG was filled out by 111 patients from an outpatient diabetes clinic of a Dutch hospital. Results Patients were advised to wash their hands with water and soap and use the first drop of blood by 89% of the Dutch and 72% of other European diabetes educators, while 58% of the patients reported to do this. When the patient cannot wash the hands, 85% of the Dutch and 52% of the other European educators advised to use the second drop of blood, while 26% of the patients reported always using the first drop without washing hands. Always using the side of the fingertip and using the lancet once, as advised in guidelines, was reported by only 41% and 55% of the patients, respectively. Conclusions There is no general agreement between professionals regarding the advice on aspects concerning SMBG. Patients also reported different acts in daily practice. Developing uniform international SMBG guidelines, education, and repeated evaluation of the process of collecting an accurate blood sample are needed.
- 6 December 2011
- Published by SAGE Publications in The Diabetes Educator
- Vol. 38 (1) , 101-107
Self-Monitoring of Blood Glucose
Purpose This study investigated the advice given by diabetes educators in Europe, and the daily practice of Dutch patients with diabetes regarding the use of the first or second drop of blood and other aspects concerning self-monitoring of blood glucose (SMBG). Method During a diabetes conference in 2009, 96 European diabetes educators (including 46 Dutch educators) completed a single-item questionnaire about the use of the first or second drop of blood for glucose monitoring. A self-reported questionnaire with 20 questions about performing SMBG was filled out by 111 patients from an outpatient diabetes clinic of a Dutch hospital. Results Patients were advised to wash their hands with water and soap and use the first drop of blood by 89% of the Dutch and 72% of other European diabetes educators, while 58% of the patients reported to do this. When the patient cannot wash the hands, 85% of the Dutch and 52% of the other European educators advised to use the second drop of blood, while 26% of the patients reported always using the first drop without washing hands. Always using the side of the fingertip and using the lancet once, as advised in guidelines, was reported by only 41% and 55% of the patients, respectively. Conclusions There is no general agreement between professionals regarding the advice on aspects concerning SMBG. Patients also reported different acts in daily practice. Developing uniform international SMBG guidelines, education, and repeated evaluation of the process of collecting an accurate blood sample are needed.
- 1 November 2011
- Published by Springer Nature in Nederlands Tijdschrift voor Diabetologie
- Vol. 9 (3) , 132-133
PS12 - 61. Improving the reliability of capillary blood glucose monitoring: using the first or second drop of blood
- 1 November 2011
- Published by Springer Nature in Nederlands Tijdschrift voor Diabetologie
- Vol. 9 (3) , 132-133
PS12 - 61. Improving the reliability of capillary blood glucose monitoring: using the first or second drop of blood
- Open Access
- 17 February 2011
- Published by American Diabetes Association in Diabetes Care
- Vol. 34 (3) , 556-560
Self-Monitoring of Blood Glucose: The Use of the First or the Second Drop of Blood
OBJECTIVE: There is no general agreement regarding the use of the first or second drop of blood for glucose monitoring. This study investigated whether capillary glucose concentrations, as measured in the first and second drops of blood, differed ≥10% compared with a control glucose concentration in different situations.RESEARCH DESIGN AND METHODS: Capillary glucose concentrations were measured in two consecutive drops of blood in the following circumstances in 123 patients with diabetes: without washing hands, after exposing the hands to fruit, after washing the fruit-exposed hands, and during application of different amounts of external pressure around the finger. The results were compared with control measurements.RESULTS: Not washing hands led to a difference in glucose concentration of ≥10% in the first and in the second drops of blood in 11% and 4% of the participants, respectively. In fruit-exposed fingers, these differences were found in 88% and 11% of the participants, respectively. Different external pressures led to ≥10% differences in glucose concentrations in 5–13% of the participants.CONCLUSIONS: We recommend washing the hands with soap and water, drying them, and using the first drop of blood for self-monitoring of blood glucose. If washing hands is not possible, and they are not visibly soiled or exposed to a sugar-containing product, it is acceptable to use the second drop of blood after wiping away the first drop. External pressure may lead to unreliable readings.
- 17 February 2011
- Published by American Diabetes Association in Diabetes Care
- Vol. 34 (3) , 556-560
Open AccessSelf-Monitoring of Blood Glucose: The Use of the First or the Second Drop of Blood
OBJECTIVE: There is no general agreement regarding the use of the first or second drop of blood for glucose monitoring. This study investigated whether capillary glucose concentrations, as measured in the first and second drops of blood, differed ≥10% compared with a control glucose concentration in different situations.RESEARCH DESIGN AND METHODS: Capillary glucose concentrations were measured in two consecutive drops of blood in the following circumstances in 123 patients with diabetes: without washing hands, after exposing the hands to fruit, after washing the fruit-exposed hands, and during application of different amounts of external pressure around the finger. The results were compared with control measurements.RESULTS: Not washing hands led to a difference in glucose concentration of ≥10% in the first and in the second drops of blood in 11% and 4% of the participants, respectively. In fruit-exposed fingers, these differences were found in 88% and 11% of the participants, respectively. Different external pressures led to ≥10% differences in glucose concentrations in 5–13% of the participants.CONCLUSIONS: We recommend washing the hands with soap and water, drying them, and using the first drop of blood for self-monitoring of blood glucose. If washing hands is not possible, and they are not visibly soiled or exposed to a sugar-containing product, it is acceptable to use the second drop of blood after wiping away the first drop. External pressure may lead to unreliable readings.
- 1 August 2010
- Vol. 68 (1) , 311-6
Self-monitoring of blood glucose in tablet-treated type 2 diabetic patients (ZODIAC).
Whether self-monitoring of blood glucose (SMBG) improves glycaemic control in patients with type 2 diabetes mellitus (T2DM) not using insulin is questionable. Our aim was to investigate the effects of SMBG in patients with T2DM who were in persistent moderate glycaemic control whilst not using insulin. Patients were eligible when between 18 and 70 years of age, with an HbA1c between 7 and 8.5%, using one or two oral blood glucose lowering agents. Forty-one of the anticipated 52 patients were randomly assigned to receive either SMBG added to usual care, or to continue with usual care for one year. A fasting glucose value and three postprandial glucose values were measured twice weekly (including a Saturday or a Sunday). The primary efficacy parameter was HbA1c. Furthermore, health-related quality of life and treatment satisfaction were assessed using the Short-form 36 Health Survey Questionnaire (SF-36), the Type 2 Diabetes Symptom Checklist (DSC-r), the Diabetes Treatment Satisfaction Questionnaire (DTSQ) and the WHO -Wellbeing Index (WHO-5). Change in HbA1c between groups was -0.05% (95% CI: -0.51, 0.41; p=0.507). Also, there were no significant changes between groups on the DTSQ , DSC type 2, WHO-5 or SF -36, except for the SF -36 dimension 'health change' which was lower in the SBMG group (mean difference: -12 (95% CI: -20.9, -3.1). On top of the absence of a clinical benefit, tablet-treated T2DM patients experienced some worsening of their health perception. We therefore argue that the use of SMBG in this patient group is questionable, and its unlimited use and promotion should be reconsidered.
- 1 August 2010
- Vol. 68 (1) , 311-6
Self-monitoring of blood glucose in tablet-treated type 2 diabetic patients (ZODIAC).
Whether self-monitoring of blood glucose (SMBG) improves glycaemic control in patients with type 2 diabetes mellitus (T2DM) not using insulin is questionable. Our aim was to investigate the effects of SMBG in patients with T2DM who were in persistent moderate glycaemic control whilst not using insulin. Patients were eligible when between 18 and 70 years of age, with an HbA1c between 7 and 8.5%, using one or two oral blood glucose lowering agents. Forty-one of the anticipated 52 patients were randomly assigned to receive either SMBG added to usual care, or to continue with usual care for one year. A fasting glucose value and three postprandial glucose values were measured twice weekly (including a Saturday or a Sunday). The primary efficacy parameter was HbA1c. Furthermore, health-related quality of life and treatment satisfaction were assessed using the Short-form 36 Health Survey Questionnaire (SF-36), the Type 2 Diabetes Symptom Checklist (DSC-r), the Diabetes Treatment Satisfaction Questionnaire (DTSQ) and the WHO -Wellbeing Index (WHO-5). Change in HbA1c between groups was -0.05% (95% CI: -0.51, 0.41; p=0.507). Also, there were no significant changes between groups on the DTSQ , DSC type 2, WHO-5 or SF -36, except for the SF -36 dimension 'health change' which was lower in the SBMG group (mean difference: -12 (95% CI: -20.9, -3.1). On top of the absence of a clinical benefit, tablet-treated T2DM patients experienced some worsening of their health perception. We therefore argue that the use of SMBG in this patient group is questionable, and its unlimited use and promotion should be reconsidered.
- 1 August 2010
- Vol. 68 (1) , 330-1
The influence of a soiled finger in capillary blood glucose monitoring.
- 1 August 2010
- Vol. 68 (1) , 330-1
The influence of a soiled finger in capillary blood glucose monitoring.