KRKumar Vids Ramnarine

Kumar Vids Ramnarine

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kumar Vids Ramnarine has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Shear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential

    by Kumar V Ramnarine, James W Garrard, Baris Kanber, Sarah Nduwayo, Timothy C Hartshorne, Thompson G Robinson

    Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and potential clinical benefit of using SWE imaging for the assessment of carotid plaques. Eighty-one patients (mean age 76 years, 51 male) underwent greyscale and SWE imaging. Elasticity was quantified by measuring mean Young’s Modulus (YM) within the plaque and within the vessel wall. Echogenicity was assessed using the Gray-Weale classification scale and the greyscale median (GSM). Fifty four plaques with stenosis greater than 30% were assessed. Reproducibility of YM measurements, quantified by the inter-frame coefficient of variation, was 22% within the vessel wall and 19% within the carotid plaque. Correlation with percentage stenosis was significant for plaque YM (p = 0.003), but insignificant for plaque GSM (p = 0.46). Plaques associated with focal neurological symptoms had significantly lower mean YM than plaques in asymptomatic patients (62 kPa vs 88 kPa; p = 0.01). Logistic regression and Receiver Operating Characteristic (ROC) analysis showed improvements in sensitivity and specificity when percentage stenosis was combined with the YM (area under ROC = 0.78). Our study showed SWE is able to quantify carotid plaque elasticity and provide additional information that may be of clinical benefit to help identify the unstable carotid plaque.


  • Shear Wave Elastography Assessment of Carotid Plaque Stiffness: In Vitro Reproducibility Study

    by Kumar V. Ramnarine, James W. Garrard, Katie Dexter, Sarah Nduwayo, Ronney B. Panerai, Thompson G. Robinson


  • Open Access

    Quantitative assessment of carotid plaque surface irregularities and correlation to cerebrovascular symptoms

    by Baris Kanber, Timothy C Hartshorne, Mark A Horsfield, A Ross Naylor, Thompson G Robinson, Kumar V Ramnarine

    Background: The purpose of this study was to determine whether surface irregularities measured from ultrasound images of carotid artery plaques and quantified using a novel method, correlate with the presence of ipsilateral hemispheric cerebrovascular symptoms. Methods: A plaque surface irregularity index (SII) was measured in 47 carotid artery plaques (32 subjects, stenosis range 10% -95%, 49% symptomatic) using ultrasound image sequences spanning several cardiac cycles. The differences in the distribution of SII in plaques with ipsilateral hemispheric symptoms versus those without symptoms and the correlation between the SII of plaques and the degrees of stenosis of the corresponding arteries were assessed. Diagnostic performance of plaque SII was evaluated on its own and in combination with the degree of stenosis. Results: The mean SII was significantly greater for plaques with ipsilateral hemispheric symptoms (1.89 radians/mm) than for asymptomatic plaques (1.67 radians/mm, p = 0.03). There was no statistically significant association between the SII and the degree of stenosis (p = 0.30). SII predicted the presence of cerebrovascular symptoms with an accuracy of 66% (sensitivity 65%, specificity 67%) on its own and with an accuracy of 83% (sensitivity 96%, specificity 71%) in combination with the degree of stenosis. Conclusions: Quantitative assessment of carotid plaque surface irregularities using a novel SII parameter correlates with the presence ipsilateral hemispheric cerebrovascular symptoms and may increase diagnostic performance beyond that provided by the degree of stenosis.


  • Open Access

    Wall motion in the stenotic carotid artery: association with greyscale plaque characteristics, the degree of stenosis and cerebrovascular symptoms

    by Baris Kanber, Timothy C Hartshorne, Mark A Horsfield, Andrew R Naylor, Thompson G Robinson, Kumar V Ramnarine

    Systolic dilation of the atherosclerotic carotid artery depends on several factors including arterial compliance and the haemodynamic environment. The purpose of this study was to quantify wall motion in stenotic carotid arteries and investigate any associations with the ultrasound greyscale plaque characteristics, the degree of stenosis, and the presence of cerebrovascular symptoms.


  • Open Access

    Dynamic variations in the ultrasound greyscale median of carotid artery plaques

    by Baris Kanber, Timothy C Hartshorne, Mark A Horsfield, Andrew R Naylor, Thompson G Robinson, Kumar V Ramnarine

    Background: Several studies have found that the ultrasound greyscale median (GSM) of carotid artery plaques may be useful for predicting the risk of cerebrovascular events. However, measurements of GSM are typically performed on still ultrasound images ignoring any variations that may be observed on a frame-by-frame basis. The aim of this study was to establish the existence and investigate the nature and extent of these variations. Methods: Employing a novel method that enabled plaque boundaries to be tracked semi-automatically, variations in the plaque GSM and observed cross-sectional area were measured for 27 carotid artery plaques (19 consecutive patients, stenosis range 10%-80%) over image sequences of up to 10 seconds in length acquired with a mean frame rate of 32 frames per second. Results: Our results showed a mean inter-frame coefficient of variation (CV) of 5.2% (s.d. 2.5%) for GSM and 4.2% (s.d. 2.9%) for the plaque area. Thirteen of the 27 plaques (48%) exhibited CV in GSM greater than 5% whereas only six plaques (22%) had CV in plaque area of greater than 5%. There was no significant correlation between the CV of GSM and plaque area. Conclusions: Inter-frame variations in the plaque GSM such as those found in this study have implications on the reproducibility of GSM measurements and their clinical utility. Studies assessing the GSM of carotid artery plaques should consider these variations.


  • Open Access

    A Probabilistic Approach to Computerized Tracking of Arterial Walls in Ultrasound Image Sequences

    by Baris Kanber, Kumar Vids Ramnarine

    Tracking of arterial walls in ultrasound image sequences is useful for studying the dynamics of arteries. Manual delineation is prohibitively labour intensive and existing methods of computerized segmentation are limited in terms of applicability and availability. This paper presents a probabilistic approach to the computerized tracking of arterial walls that is effective and easy to implement. In the probabilistic approach, given a point B with a probability Pb of being in an arterial lumen of interest, the probability Pa that a neighbouring point A is also a part of the same lumen is proportional to Pb with a Gaussian fall in probability with increasing grayscale contrast between the two points. Efficacy of the probabilistic algorithm was evaluated by testing it on ultrasound images and image sequences of the carotid arteries and the abdominal aorta and various laboratory, ultrasound test objects. The results showed that the probabilistic algorithm produced robust and effective lumen segmentation in the majority of cases encountered. Comparison with a conventional region growing technique based on intensity thresholding with a running, regional intensity average identified the main benefits of the probabilistic approach as increased immunity to speckle noise within the arterial lumen and a reduced susceptibility to region overflowing at boundary imperfections.


  • Dynamic assessment of carotid plaque motion

    by Zeynettin Akkus, Kumar V Ramnarine

    Assessment of dynamic plaque behaviour may help identify vulnerable carotid plaque before rupture and hence has potential clinical value for screening patients at risk of stroke. The aim of this study was to develop non-invasive ultrasound methods for quantifying dynamic plaque and vessel wall behaviour and assess their potential clinical utility. Ultrasound data from the carotid arteries of one normal subject and four patients with atherosclerotic disease were acquired using a 10 MHz linear array transducer recording raw RF/IQ data at a frame rate up to 80 Hz for 3–6 seconds. Image reconstruction and processing was performed using Matlab. Speckle tracking techniques were developed to characterize: (1) intraplaque deformation; and (2) plaque surface and vessel wall motion. Speckle tracking techniques were able to measure the range of intraplaque tissue deformation (–1.3 to 1.7 mm), plaque surface displacement (0.2–0.7 mm) and vessel wall radial strain (0.02–0.13) throughout the cardiac cycle. The feasibility of using an intraplaque deformation parameter, based on the deformation of a square template, is demonstrated. Speckle tracking techniques can be used to assess dynamic carotid plaque behaviour. Further work is required to evaluate how best to quantify biomechanical behaviour to help predict plaque rupture and hence improve risk stratification models for stroke.


  • Open Access

    Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    by Kumar V Ramnarine, Tim Hartshorne, Yvonne Sensier, May Naylor, Joanne Walker, A Ross Naylor, Ronney B Panerai, David H Evans

    Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI) of Arterial Wall Motion (AWM) and to quantify simple wall motion indices in normal and diseased carotid arteries. 224 normal and diseased carotid arteries (0–100% stenoses) were imaged in 126 patients (age 25–88 years, mean 68 ± 11). Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.