Timothy C Hartshorne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timothy C Hartshorne has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Kumar Vids Ramnarine
Department of Medical Physics, University Hospitals of Leicester NHS Trust, Sandringham Building, Level 1, Leicester Royal Infirmary, Infirmary Square, Leicester LE1 5WW UK.
5 shared publications - Andrew R Naylor
The Leicester Vascular Institute, Glenfield Hospital, Leicester, UK
4 shared publications - Baris Kanber
Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
4 shared publications - Thompson Gordon Robinson
Department of Cardiovascular Sciences and NIHR Biomedical Research Unit in Cardiovascular Disease, University of Leicester, United Kingdom
4 shared publications - Mark Andrew Horsfield
Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
3 shared publications A. Nasim
Department of Vascular and Endovascular Surgery, Leicester Royal Infirmary, Leicester, UK
1 shared publication
Latest Publications
- Open Access
- 8 December 2014
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 12 (1) , 49
Shear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential
Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and potential clinical benefit of using SWE imaging for the assessment of carotid plaques. Eighty-one patients (mean age 76 years, 51 male) underwent greyscale and SWE imaging. Elasticity was quantified by measuring mean Young’s Modulus (YM) within the plaque and within the vessel wall. Echogenicity was assessed using the Gray-Weale classification scale and the greyscale median (GSM). Fifty four plaques with stenosis greater than 30% were assessed. Reproducibility of YM measurements, quantified by the inter-frame coefficient of variation, was 22% within the vessel wall and 19% within the carotid plaque. Correlation with percentage stenosis was significant for plaque YM (p = 0.003), but insignificant for plaque GSM (p = 0.46). Plaques associated with focal neurological symptoms had significantly lower mean YM than plaques in asymptomatic patients (62 kPa vs 88 kPa; p = 0.01). Logistic regression and Receiver Operating Characteristic (ROC) analysis showed improvements in sensitivity and specificity when percentage stenosis was combined with the YM (area under ROC = 0.78). Our study showed SWE is able to quantify carotid plaque elasticity and provide additional information that may be of clinical benefit to help identify the unstable carotid plaque.
- 8 December 2014
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 12 (1) , 49
Open AccessShear wave elastography imaging of carotid plaques: feasible, reproducible and of clinical potential
Shear Wave Elastography (SWE) imaging is a novel ultrasound technique for quantifying tissue elasticity. Studies have demonstrated that SWE is able to differentiate between diseased and normal tissue in a wide range clinical applications. However its applicability to atherosclerotic carotid disease has not been established. The aim of this study was to assess the feasibility and potential clinical benefit of using SWE imaging for the assessment of carotid plaques. Eighty-one patients (mean age 76 years, 51 male) underwent greyscale and SWE imaging. Elasticity was quantified by measuring mean Young’s Modulus (YM) within the plaque and within the vessel wall. Echogenicity was assessed using the Gray-Weale classification scale and the greyscale median (GSM). Fifty four plaques with stenosis greater than 30% were assessed. Reproducibility of YM measurements, quantified by the inter-frame coefficient of variation, was 22% within the vessel wall and 19% within the carotid plaque. Correlation with percentage stenosis was significant for plaque YM (p = 0.003), but insignificant for plaque GSM (p = 0.46). Plaques associated with focal neurological symptoms had significantly lower mean YM than plaques in asymptomatic patients (62 kPa vs 88 kPa; p = 0.01). Logistic regression and Receiver Operating Characteristic (ROC) analysis showed improvements in sensitivity and specificity when percentage stenosis was combined with the YM (area under ROC = 0.78). Our study showed SWE is able to quantify carotid plaque elasticity and provide additional information that may be of clinical benefit to help identify the unstable carotid plaque.
- Open Access
- 6 November 2013
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 11 (1) , 38
Quantitative assessment of carotid plaque surface irregularities and correlation to cerebrovascular symptoms
Background: The purpose of this study was to determine whether surface irregularities measured from ultrasound images of carotid artery plaques and quantified using a novel method, correlate with the presence of ipsilateral hemispheric cerebrovascular symptoms. Methods: A plaque surface irregularity index (SII) was measured in 47 carotid artery plaques (32 subjects, stenosis range 10% -95%, 49% symptomatic) using ultrasound image sequences spanning several cardiac cycles. The differences in the distribution of SII in plaques with ipsilateral hemispheric symptoms versus those without symptoms and the correlation between the SII of plaques and the degrees of stenosis of the corresponding arteries were assessed. Diagnostic performance of plaque SII was evaluated on its own and in combination with the degree of stenosis. Results: The mean SII was significantly greater for plaques with ipsilateral hemispheric symptoms (1.89 radians/mm) than for asymptomatic plaques (1.67 radians/mm, p = 0.03). There was no statistically significant association between the SII and the degree of stenosis (p = 0.30). SII predicted the presence of cerebrovascular symptoms with an accuracy of 66% (sensitivity 65%, specificity 67%) on its own and with an accuracy of 83% (sensitivity 96%, specificity 71%) in combination with the degree of stenosis. Conclusions: Quantitative assessment of carotid plaque surface irregularities using a novel SII parameter correlates with the presence ipsilateral hemispheric cerebrovascular symptoms and may increase diagnostic performance beyond that provided by the degree of stenosis.
- 6 November 2013
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 11 (1) , 38
Open AccessQuantitative assessment of carotid plaque surface irregularities and correlation to cerebrovascular symptoms
Background: The purpose of this study was to determine whether surface irregularities measured from ultrasound images of carotid artery plaques and quantified using a novel method, correlate with the presence of ipsilateral hemispheric cerebrovascular symptoms. Methods: A plaque surface irregularity index (SII) was measured in 47 carotid artery plaques (32 subjects, stenosis range 10% -95%, 49% symptomatic) using ultrasound image sequences spanning several cardiac cycles. The differences in the distribution of SII in plaques with ipsilateral hemispheric symptoms versus those without symptoms and the correlation between the SII of plaques and the degrees of stenosis of the corresponding arteries were assessed. Diagnostic performance of plaque SII was evaluated on its own and in combination with the degree of stenosis. Results: The mean SII was significantly greater for plaques with ipsilateral hemispheric symptoms (1.89 radians/mm) than for asymptomatic plaques (1.67 radians/mm, p = 0.03). There was no statistically significant association between the SII and the degree of stenosis (p = 0.30). SII predicted the presence of cerebrovascular symptoms with an accuracy of 66% (sensitivity 65%, specificity 67%) on its own and with an accuracy of 83% (sensitivity 96%, specificity 71%) in combination with the degree of stenosis. Conclusions: Quantitative assessment of carotid plaque surface irregularities using a novel SII parameter correlates with the presence ipsilateral hemispheric cerebrovascular symptoms and may increase diagnostic performance beyond that provided by the degree of stenosis.
- Open Access
- 20 October 2013
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 11 (1) , 37
Wall motion in the stenotic carotid artery: association with greyscale plaque characteristics, the degree of stenosis and cerebrovascular symptoms
Systolic dilation of the atherosclerotic carotid artery depends on several factors including arterial compliance and the haemodynamic environment. The purpose of this study was to quantify wall motion in stenotic carotid arteries and investigate any associations with the ultrasound greyscale plaque characteristics, the degree of stenosis, and the presence of cerebrovascular symptoms.
- 20 October 2013
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 11 (1) , 37
Open AccessWall motion in the stenotic carotid artery: association with greyscale plaque characteristics, the degree of stenosis and cerebrovascular symptoms
Systolic dilation of the atherosclerotic carotid artery depends on several factors including arterial compliance and the haemodynamic environment. The purpose of this study was to quantify wall motion in stenotic carotid arteries and investigate any associations with the ultrasound greyscale plaque characteristics, the degree of stenosis, and the presence of cerebrovascular symptoms.
- Open Access
- 14 June 2013
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 11 (1) , 21
Dynamic variations in the ultrasound greyscale median of carotid artery plaques
Background: Several studies have found that the ultrasound greyscale median (GSM) of carotid artery plaques may be useful for predicting the risk of cerebrovascular events. However, measurements of GSM are typically performed on still ultrasound images ignoring any variations that may be observed on a frame-by-frame basis. The aim of this study was to establish the existence and investigate the nature and extent of these variations. Methods: Employing a novel method that enabled plaque boundaries to be tracked semi-automatically, variations in the plaque GSM and observed cross-sectional area were measured for 27 carotid artery plaques (19 consecutive patients, stenosis range 10%-80%) over image sequences of up to 10 seconds in length acquired with a mean frame rate of 32 frames per second. Results: Our results showed a mean inter-frame coefficient of variation (CV) of 5.2% (s.d. 2.5%) for GSM and 4.2% (s.d. 2.9%) for the plaque area. Thirteen of the 27 plaques (48%) exhibited CV in GSM greater than 5% whereas only six plaques (22%) had CV in plaque area of greater than 5%. There was no significant correlation between the CV of GSM and plaque area. Conclusions: Inter-frame variations in the plaque GSM such as those found in this study have implications on the reproducibility of GSM measurements and their clinical utility. Studies assessing the GSM of carotid artery plaques should consider these variations.
- 14 June 2013
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 11 (1) , 21
Open AccessDynamic variations in the ultrasound greyscale median of carotid artery plaques
Background: Several studies have found that the ultrasound greyscale median (GSM) of carotid artery plaques may be useful for predicting the risk of cerebrovascular events. However, measurements of GSM are typically performed on still ultrasound images ignoring any variations that may be observed on a frame-by-frame basis. The aim of this study was to establish the existence and investigate the nature and extent of these variations. Methods: Employing a novel method that enabled plaque boundaries to be tracked semi-automatically, variations in the plaque GSM and observed cross-sectional area were measured for 27 carotid artery plaques (19 consecutive patients, stenosis range 10%-80%) over image sequences of up to 10 seconds in length acquired with a mean frame rate of 32 frames per second. Results: Our results showed a mean inter-frame coefficient of variation (CV) of 5.2% (s.d. 2.5%) for GSM and 4.2% (s.d. 2.9%) for the plaque area. Thirteen of the 27 plaques (48%) exhibited CV in GSM greater than 5% whereas only six plaques (22%) had CV in plaque area of greater than 5%. There was no significant correlation between the CV of GSM and plaque area. Conclusions: Inter-frame variations in the plaque GSM such as those found in this study have implications on the reproducibility of GSM measurements and their clinical utility. Studies assessing the GSM of carotid artery plaques should consider these variations.
- 1 August 2011
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 42 (2) , 195-199
Ultrasound Measurement of Aortic Diameter in a National Screening Programme
- 1 August 2011
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 42 (2) , 195-199
Ultrasound Measurement of Aortic Diameter in a National Screening Programme
- Open Access
- 19 December 2003
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 1 (1) , 1-15
Tissue Doppler imaging of carotid plaque wall motion: a pilot study
Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI) of Arterial Wall Motion (AWM) and to quantify simple wall motion indices in normal and diseased carotid arteries. 224 normal and diseased carotid arteries (0–100% stenoses) were imaged in 126 patients (age 25–88 years, mean 68 ± 11). Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.
- 19 December 2003
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 1 (1) , 1-15
Open AccessTissue Doppler imaging of carotid plaque wall motion: a pilot study
Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI) of Arterial Wall Motion (AWM) and to quantify simple wall motion indices in normal and diseased carotid arteries. 224 normal and diseased carotid arteries (0–100% stenoses) were imaged in 126 patients (age 25–88 years, mean 68 ± 11). Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.