PCPedro Carmo

Pedro Carmo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pedro Carmo has a total of 128 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predicting Atrial Fibrillation Relapse Using Bayesian Networks: Explainable AI Approach

    by João Miguel Alves, Daniel Matos, Tiago Martins, Diogo Cavaco, Pedro Carmo, Pedro Galvão, Francisco Moscoso Costa, Francisco Morgado, António Miguel Ferreira, Pedro Freitas, et al.

    Background: Atrial fibrillation (AF) is a prevalent arrhythmia associated with significant morbidity and mortality. Despite advancements in ablation techniques, predicting recurrence of AF remains a challenge, necessitating reliable models to identify patients at risk of relapse. Traditional scoring systems often lack applicability in diverse clinical settings and may not incorporate the latest evidence-based factors influencing AF outcomes. This study aims to develop an explainable artificial intelligence model using Bayesian networks to predict AF relapse postablation, leveraging on easily obtainable clinical variables. Objective: This study aims to investigate the effectiveness of Bayesian networks as a predictive tool for AF relapse following a percutaneous pulmonary vein isolation (PVI) procedure. The objectives include evaluating the model’s performance using various clinical predictors, assessing its adaptability to incorporate new risk factors, and determining its potential to enhance clinical decision-making in the management of AF. Methods: This study analyzed data from 480 patients with symptomatic drug-refractory AF who underwent percutaneous PVI. To predict AF relapse following the procedure, an explainable artificial intelligence model based on Bayesian networks was developed. The model used a variable number of clinical predictors, including age, sex, smoking status, preablation AF type, left atrial volume, epicardial fat, obstructive sleep apnea, and BMI. The predictive performance of the model was evaluated using the area under the receiver operating characteristic curve (AUC-ROC) metrics across different configurations of predictors (5, 6, and 7 variables). Validation was conducted through four distinct sampling techniques to ensure robustness and reliability of the predictions. Results: The Bayesian network model demonstrated promising predictive performance for AF relapse. Using 5 predictors (age, sex, smoking, preablation AF type, and obstructive sleep apnea), the model achieved an AUC-ROC of 0.661 (95% CI 0.603‐0.718). Incorporating additional predictors improved performance, with a 6-predictor model (adding BMI) achieving an AUC-ROC of 0.703 (95% CI 0.652‐0.753) and a 7-predictor model (adding left atrial volume and epicardial fat) achieving an AUC-ROC of 0.752 (95% CI 0.701‐0.800). These results indicate that the model can effectively estimate the risk of AF relapse using readily available clinical variables. Notably, the model maintained acceptable diagnostic accuracy even in scenarios where some predictive features were missing, highlighting its adaptability and potential use in real-world clinical settings. Conclusions: The developed Bayesian network model provides a reliable and interpretable tool for predicting AF relapse in patients undergoing percutaneous PVI. By using easily accessible clinical variables, presenting acceptable diagnostic accuracy, and showing adaptability to incorporate new medical knowledge over time, the model demonstrates a flexibility and robustness that makes it suitable for real-world clinical scenarios.


  • Open Access

    Leadless vs. transvenous single-chamber pacing - propensity-matched comparison of outcomes

    by R Amador, J Presume, P Carmo, J Carmo, A R R Santos, D Matos, G Rodrigues, P G Santos, F M Costa, M S Carvalho, et al.

    Background: Clinical Trials have demonstrated the safety and efficacy of the leadless pacemaker. However, real-world outcome comparisons between patients receiving conventional VVI and leadless pacemakers are still scarce. The aim of this study was to evaluate short and long-term complications of patients receiving leadless pacemakers in comparison to a population of conventional VVI. Methods: We conducted a single-centre retrospective study of patients receiving the leadless or a conventional VVI between 2014 and 2022. Propensity score matching was performed on 725 patients (156 leadless and 569 conventional) and according to age, sex, coronary artery disease (CAD), chronic kidney disease (CKD), haemodialysis and AF, with a 1:1 matching protocol without replacement (matching tolerance 5%). Complications that occurred up to one month after implantation were considered acute and included access site BARC ≥ 3 bleeding events, pacemaker pocket hematoma requiring medical intervention (either drainage o antibiotic therapy), femoral access infection, pneumothorax, pericardial effusion, cardiac tamponade, and dysfunction of the implanted device. Long-term complications were defined as those occurring at least one month after implantation and included device infection, need for reintervention, and device upgrades due to left ventricular dysfunction. The primary outcome was a composite of acute and long-term complications. Results: A total of 312 patients (80 [73 - 86] years, 63% male, 79% with AF and 7% on dialysis) were included, 156 within each group. The main indication for PM implantation was AF with low ventricular rate (48%), followed by atrioventricular block (31%) and sick sinus syndrome (13%). In total, 19 patients (16%) had a previously implanted device, and 14 (4%) had previously been submitted to lead extraction, of which 10 (71%) were due to device-related infection. All of these were more frequent in patients receiving the leadless pacemaker (p = 0.001). During a median follow-up of 26 [11 - 47] months, a total of 32 patients (10%) had a complication related to the implantation of the device – table 1. While intra-hospital complications showed only a tendency towards higher incidence in the VVI group (5% vs 3%; p = 0.124), overall complications (16% vs 5%) and long-term complications (12% vs 2%) were higher in the VVI group (p < 0.001 for both). The Kaplan-Meier curves for the primary outcome showed a significantly lower event-rate for patients receiving the leadless pacemaker – Figure 1. Conclusions: In this propensity-matched study, leadless pacemaker implantation was associated with a lower incidence of complications during follow-up, in comparison to conventional VVI pacemaker.

  • Open Access

    Using the 3D architecture of scar to predict life-threatening ventricular arrhythmias, still a long way to go

    by R Amador, A R Bello, P Freitas, S Guerreiro, J Abecasis, A Coutinho Santos, C Saraiva, P G Santos, F M Costa, M S Carvalho, et al.

    Background: Late gadolinium enhancement (LGE) has been proposed as an independent predictor of ventricular arrhythmias. Purpose: The purpose of this study was to assess if myocardial scar characterization could enhance the risk stratification for life-threatening arrhythmias and sudden cardiac death (SCD). Methods: We included patients with an indication for ICD or CRT-D implantation who underwent cardiac magnetic resonance for clinical proposes since February/2018 and in whom a 3D-LGE dataset was obtained. Patients with channelopathies (n=2) or inappropriate imaging quality (imaging artifacts; n=7) were excluded. Scar characterization using ADAS software was performed in 3D-LGE datasets in all but 16 patients, where 2D datasets were used. The primary endpoint was the composite of appropriate ICD therapy (classified as ATP or shock), sustained ventricular tachycardia or SCD. Results: A total of 116 patients were analysed (mean age 66 ± 14 years; 81% male; mean LVEF 34 ± 14%; 74 patients with ischemic and 42 with non-ischemic cardiomyopathy; 40 patients received a device in the setting of secondary prevention). During a median follow-up of 2.3 years (IQR 1.3 – 3.3 years) there were 23 events (18 appropriate ICD therapies [9 shocks and 9 ATP], 3 episodes of VT under the threshold for ICD therapy and 2 SCD). No statistically significant differences were found between patients with or without events in terms of scar mass, border zone (BZ) mass, BZ channels (BZC), BZC mass, number of channels detected, and scar heterogeneity (BZ mass / scar mass ratio) - all p values > 0.2 – Figure. Restricting the analysis to only primary prevention cases yielded similar results. Overall, 26 patients did not show any channel. Four of these (all with non-ischemic LGE) experienced an arrhythmic event, yielding a negative predictive value of 83% (95% CI 64-93%) for the absence of channels. Conclusion: In this cohort with still relatively limited follow-up duration, no single parameter reflecting scar tissue characterization was able to predict appropriate device therapies or sudden cardiac death.

  • Open Access

    Using the 3D architecture of scar to predict life-threatening ventricular arrythmias - still a long way to go

    by R Amador, A R Bello, P Freitas, S Guerreiro, J Abecasis, A Coutinho Santos, C Saraiva, P Galvao Santos, F Moscoso Costa, M S Carvalho, et al.

    Funding Acknowledgements: Type of funding sources: None. Background: Late gadolinium enhancement (LGE) has been proposed as an independent predictor of ventricular arrhythmias. Purpose: The purpose of this study was to assess if myocardial scar characterization could enhance the risk stratification for life-threatening arrhythmias and sudden cardiac death (SCD). Methods: We included patients with an indication for ICD or CRT-D implantation who underwent cardiac magnetic resonance for clinical proposes since February/2018 and in whom a 3D-LGE dataset was obtained. Patients with channelopathies (n=2) or inappropriate imaging quality (imaging artifacts; n=7) were excluded. Scar characterization using ADAS software was performed in 3D-LGE datasets in all but 5 patients, where 2D datasets were used. The primary endpoint was the composite of appropriate ICD therapy (classified as ATP or shock) or SCD. Results: A total of 75 patients were analysed (mean age 63 ± 13 years; 83% male; mean LVEF 31 ± 13%; 50 patients with ischemic and 25 with non-ischemic cardiomyopathy; 14 patients received a device in the setting of secondary prevention). During a median follow-up of 1.4 years (IQR 0.7 – 2.4 years) there were 15 events (12 appropriate ICD therapies [8 shocks and 4 ATP] and 3 SCD). No statistically significant differences were found between patients with or without events in terms of scar mass, border zone (BZ) mass, BZ channels (BZC), BZC mass, number of channels detected, and scar heterogeneity (BZ mass / scar mass ratio) - all p values > 0.2 – Figure. Restricting the analysis to only primary prevention cases yielded similar results. Overall, 11 patients did not show any channel. Two of these experienced an arrhythmic event, yielding a negative predictive value of 80% (95% CI 75-83%) for the absence of channels. Conclusion: In this cohort with still relatively limited follow-up duration, no single parameter reflecting scar tissue characterization was able to predict appropriate device therapies or sudden cardiac death.

  • Open Access

    Association between left ventricular wall-thickness by CT and endocardial voltage potentials in patients with ischemic cardiomyopathy

    by D Gomes, G Cunha, P Freitas, S Guerreiro, J Abecasis, G Rodrigues, D Matos, J Carmo, P Galvao Santos, F Moscoso Costa, et al.

    Funding Acknowledgements: Type of funding sources: None. Background: Although cardiac magnetic resonance (CMR) is the gold standard for planning ventricular tachycardia (VT) ablation, its accuracy is hindered in patients with implanted cardiac defibrillators (ICD) and resynchronization therapy (CRT). Cardiac computed tomography (CT) has emerged as an alternative for ablation planning in these patients. This pilot study aimed to evaluate the relationship between wall thickness (WT) on CT and voltage of electrical potentials on endocardial electroanatomic mapping (EAM) in patients with ischemic cardiomyopathy. Methods: Single centre retrospective study enrolling consecutive patients with ischemic cardiomyopathy referred for endocardial VT ablation that underwent cardiac CT for procedure planning since 2021. Patients were excluded if EAM had < 1000 data points. ADAS 3D® software was used to analyse CT images, automatically segmenting the left ventricle (LV) into the 17 American Heart Association segments and calculating end-diastolic WT for each one. Four standardized views (anterior-posterior, posterior-anterior, superior, and inferior) of the segmented LV on ADAS 3D® were used to aid in manual segmentation of the EAM. The endocardial voltage maps were created using CARTO3® software (Figure 1). For each patient, EAM was interpreted to create 2 different bulls’ eye maps, according to the presence or absence of bipolar potentials < 0.5 (dense scar) or < 1.5mV (low voltage). Only segments with >20% extension of low bipolar voltage were considered as altered. Results: We included a cohort of 8 patients (mean age 67±12 years, 87.5% male, median LVEF of 32% [IQR 25-49]). All but one patient had implanted cardiac device (6 ICD, 1 CRT-D). Cardiac CT was performed 1 day (IQR 0-2) before the ablation. Overall, 136 segments were analysed, 8 of which did not have voltage information. Of the remaining 128, 51 (39.8%) had dense scar and 57 (41.9%) had low voltage. There was a good correlation between mean WT and the presence or absence of both dense scar (area under de curve (AUC) 0.799, p<0.001) and low voltage (AUC 0.838, p<0.001) in each LV segment. Conclusion: WT measured by CT appears to have a strong correlation with dense scar and low voltage in EAM in patients with ischemic cardiomyopathy undergoing VT ablation. This technique may be useful to plan interventions in patients in whom CMR is not feasible.


  • Open Access

    Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site

    by Leonor Parreira, Alexey Tsyganov, Elena Artyukhina, Kevin Vernooy, Claudio Tondo, Pedro Adragao, Ciro Ascione, Pedro Carmo, Salomé Carvalho, Matthias Egger, et al.

    Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6–24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931). The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.


  • Trainees as simulated patients in family medicine/general practice OSCE stations for undergraduate students: Unintended (positive) consequences

    by Raquel Ascenção, David Afonso, Sandra Lopes, Pedro Carmo, Inês Coelho, Sara Coelho e Silva, Catarina Gaspar, Ivone Gonçalves Gaspar, Luís Fortuna, Margarida Morais Lopes, et al.

    Dear EditorIn our medical school, an OSCE was recently introduced as a high-stakes exam in the 4th year. For the first time, Family Medicine/General Practice (FM/GP) faculty members were involved i...

  • Open Access

    Analysis of a 10-year period of lead removal in a referral centre

    by Rita Marinheiro, José Pedro Neves, Francisco Morgado, Márcio Madeira, Pedro Magro, Pedro Carmo, Pedro Adragão

    OBJECTIVES: Our goal was to analyse all lead extraction procedures (transvenous or open surgery) performed in our centre and the short- and long-term follow-up data from these patients. METHODS: All lead extractions performed from 2008 to 2017 were retrospectively reviewed for patient characteristics and indications for device implantation; indications for lead extraction; techniques used; peri- and postprocedural complications and short- and long-term follow-up data. RESULTS: A total of 159 patients (282 leads) were included [age 70 (62–78) years; 72% men]. The median follow-up time was 57 (25–90) months. Patients with lead explants were excluded. The most common indication for lead removal was infection (77%). A surgical approach was necessary in 14 patients (9%) owing to unsuccessful transvenous removal (n = 3), large vegetation in the lead (n = 4), concomitant valvular endocarditis (n = 2), other indications for open surgery (n = 4) and complicated transvenous removal (n = 1). Removal was tried for 282 leads. Of those, 256 were completely removed. Clinical success was achieved in 155 individual patients (98%). Complications occurred in 6 patients: 3 persistent infections, 1 stroke and 2 blood vessel ruptures. The procedure-related mortality rate was 2% (n = 3). CONCLUSIONS: Lead removal was associated with a high success rate and low all-cause complication and mortality rates. Emergency surgery because of acute complications was rare, and open-heart surgery was most frequently elective and not associated with a worse outcome.