Francisco Morgado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francisco Morgado has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Adragão
Hospital de Santa Cruz, Lisbon, Portugal
6 shared publications - Pedro Carmo
Hospital Santa Cruz , Lisbon , Portugal
6 shared publications - Diogo Cavaco
Department of Cardiology, Hospital de Santa Cruz, Carnaxide, Portugal; Department of Cardiology, Hospital da Luz, Lisboa, Portugal
5 shared publications - Francisco Moscoso Costa
Department of Cardiology, Hospital Santa Cruz , Lisbon
4 shared publications - Maria Salomé Carvalho
Hospital Santa Cruz , Lisbon , Portugal
3 shared publications - Rosalís Amador
Hospital Santa Cruz , Lisbon , Portugal
3 shared publications
Latest Publications
- Open Access
- 1 April 2024
- Published by International Scientific Invention Journals in International Journal of Innovative Research in Medical Science
- Vol. 9 (04) , 199-201
Pseudomyxoma Peritonei: A Case Report of a 73-Year-Old Male Presenting with Abdominal Distension
Pseudomyxoma peritonei is characterized by diffuse mucinous ascites and mucinous implants on the peritoneal surfaces. The authors report a case of a 73-year-old man with complaints of abdominal distention, nausea, fatigue, and asthenia for the past two months. The patient underwent diagnostic laparoscopy, and histological examination revealed pseudomyxoma peritonei secondary to low-grade mucinous carcinoma with intestinal differentiation. The patient was referred to Oncology for hyperthermic intraperitoneal chemotherapy along with complete cytoreduction surgery.
- 1 April 2024
- Published by International Scientific Invention Journals in International Journal of Innovative Research in Medical Science
- Vol. 9 (04) , 199-201
Open AccessPseudomyxoma Peritonei: A Case Report of a 73-Year-Old Male Presenting with Abdominal Distension
Pseudomyxoma peritonei is characterized by diffuse mucinous ascites and mucinous implants on the peritoneal surfaces. The authors report a case of a 73-year-old man with complaints of abdominal distention, nausea, fatigue, and asthenia for the past two months. The patient underwent diagnostic laparoscopy, and histological examination revealed pseudomyxoma peritonei secondary to low-grade mucinous carcinoma with intestinal differentiation. The patient was referred to Oncology for hyperthermic intraperitoneal chemotherapy along with complete cytoreduction surgery.
- Open Access
- 9 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (Supplement)
Leadless vs. transvenous single-chamber pacing - propensity-matched comparison of outcomes
Background: Clinical Trials have demonstrated the safety and efficacy of the leadless pacemaker. However, real-world outcome comparisons between patients receiving conventional VVI and leadless pacemakers are still scarce. The aim of this study was to evaluate short and long-term complications of patients receiving leadless pacemakers in comparison to a population of conventional VVI. Methods: We conducted a single-centre retrospective study of patients receiving the leadless or a conventional VVI between 2014 and 2022. Propensity score matching was performed on 725 patients (156 leadless and 569 conventional) and according to age, sex, coronary artery disease (CAD), chronic kidney disease (CKD), haemodialysis and AF, with a 1:1 matching protocol without replacement (matching tolerance 5%). Complications that occurred up to one month after implantation were considered acute and included access site BARC ≥ 3 bleeding events, pacemaker pocket hematoma requiring medical intervention (either drainage o antibiotic therapy), femoral access infection, pneumothorax, pericardial effusion, cardiac tamponade, and dysfunction of the implanted device. Long-term complications were defined as those occurring at least one month after implantation and included device infection, need for reintervention, and device upgrades due to left ventricular dysfunction. The primary outcome was a composite of acute and long-term complications. Results: A total of 312 patients (80 [73 - 86] years, 63% male, 79% with AF and 7% on dialysis) were included, 156 within each group. The main indication for PM implantation was AF with low ventricular rate (48%), followed by atrioventricular block (31%) and sick sinus syndrome (13%). In total, 19 patients (16%) had a previously implanted device, and 14 (4%) had previously been submitted to lead extraction, of which 10 (71%) were due to device-related infection. All of these were more frequent in patients receiving the leadless pacemaker (p = 0.001). During a median follow-up of 26 [11 - 47] months, a total of 32 patients (10%) had a complication related to the implantation of the device – table 1. While intra-hospital complications showed only a tendency towards higher incidence in the VVI group (5% vs 3%; p = 0.124), overall complications (16% vs 5%) and long-term complications (12% vs 2%) were higher in the VVI group (p < 0.001 for both). The Kaplan-Meier curves for the primary outcome showed a significantly lower event-rate for patients receiving the leadless pacemaker – Figure 1. Conclusions: In this propensity-matched study, leadless pacemaker implantation was associated with a lower incidence of complications during follow-up, in comparison to conventional VVI pacemaker.
- 9 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (Supplement)
Open AccessLeadless vs. transvenous single-chamber pacing - propensity-matched comparison of outcomes
Background: Clinical Trials have demonstrated the safety and efficacy of the leadless pacemaker. However, real-world outcome comparisons between patients receiving conventional VVI and leadless pacemakers are still scarce. The aim of this study was to evaluate short and long-term complications of patients receiving leadless pacemakers in comparison to a population of conventional VVI. Methods: We conducted a single-centre retrospective study of patients receiving the leadless or a conventional VVI between 2014 and 2022. Propensity score matching was performed on 725 patients (156 leadless and 569 conventional) and according to age, sex, coronary artery disease (CAD), chronic kidney disease (CKD), haemodialysis and AF, with a 1:1 matching protocol without replacement (matching tolerance 5%). Complications that occurred up to one month after implantation were considered acute and included access site BARC ≥ 3 bleeding events, pacemaker pocket hematoma requiring medical intervention (either drainage o antibiotic therapy), femoral access infection, pneumothorax, pericardial effusion, cardiac tamponade, and dysfunction of the implanted device. Long-term complications were defined as those occurring at least one month after implantation and included device infection, need for reintervention, and device upgrades due to left ventricular dysfunction. The primary outcome was a composite of acute and long-term complications. Results: A total of 312 patients (80 [73 - 86] years, 63% male, 79% with AF and 7% on dialysis) were included, 156 within each group. The main indication for PM implantation was AF with low ventricular rate (48%), followed by atrioventricular block (31%) and sick sinus syndrome (13%). In total, 19 patients (16%) had a previously implanted device, and 14 (4%) had previously been submitted to lead extraction, of which 10 (71%) were due to device-related infection. All of these were more frequent in patients receiving the leadless pacemaker (p = 0.001). During a median follow-up of 26 [11 - 47] months, a total of 32 patients (10%) had a complication related to the implantation of the device – table 1. While intra-hospital complications showed only a tendency towards higher incidence in the VVI group (5% vs 3%; p = 0.124), overall complications (16% vs 5%) and long-term complications (12% vs 2%) were higher in the VVI group (p < 0.001 for both). The Kaplan-Meier curves for the primary outcome showed a significantly lower event-rate for patients receiving the leadless pacemaker – Figure 1. Conclusions: In this propensity-matched study, leadless pacemaker implantation was associated with a lower incidence of complications during follow-up, in comparison to conventional VVI pacemaker.
- Open Access
- 9 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (Supplement)
Using the 3D architecture of scar to predict life-threatening ventricular arrhythmias, still a long way to go
Background: Late gadolinium enhancement (LGE) has been proposed as an independent predictor of ventricular arrhythmias. Purpose: The purpose of this study was to assess if myocardial scar characterization could enhance the risk stratification for life-threatening arrhythmias and sudden cardiac death (SCD). Methods: We included patients with an indication for ICD or CRT-D implantation who underwent cardiac magnetic resonance for clinical proposes since February/2018 and in whom a 3D-LGE dataset was obtained. Patients with channelopathies (n=2) or inappropriate imaging quality (imaging artifacts; n=7) were excluded. Scar characterization using ADAS software was performed in 3D-LGE datasets in all but 16 patients, where 2D datasets were used. The primary endpoint was the composite of appropriate ICD therapy (classified as ATP or shock), sustained ventricular tachycardia or SCD. Results: A total of 116 patients were analysed (mean age 66 ± 14 years; 81% male; mean LVEF 34 ± 14%; 74 patients with ischemic and 42 with non-ischemic cardiomyopathy; 40 patients received a device in the setting of secondary prevention). During a median follow-up of 2.3 years (IQR 1.3 – 3.3 years) there were 23 events (18 appropriate ICD therapies [9 shocks and 9 ATP], 3 episodes of VT under the threshold for ICD therapy and 2 SCD). No statistically significant differences were found between patients with or without events in terms of scar mass, border zone (BZ) mass, BZ channels (BZC), BZC mass, number of channels detected, and scar heterogeneity (BZ mass / scar mass ratio) - all p values > 0.2 – Figure. Restricting the analysis to only primary prevention cases yielded similar results. Overall, 26 patients did not show any channel. Four of these (all with non-ischemic LGE) experienced an arrhythmic event, yielding a negative predictive value of 83% (95% CI 64-93%) for the absence of channels. Conclusion: In this cohort with still relatively limited follow-up duration, no single parameter reflecting scar tissue characterization was able to predict appropriate device therapies or sudden cardiac death.
- 9 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 44 (Supplement)
Open AccessUsing the 3D architecture of scar to predict life-threatening ventricular arrhythmias, still a long way to go
Background: Late gadolinium enhancement (LGE) has been proposed as an independent predictor of ventricular arrhythmias. Purpose: The purpose of this study was to assess if myocardial scar characterization could enhance the risk stratification for life-threatening arrhythmias and sudden cardiac death (SCD). Methods: We included patients with an indication for ICD or CRT-D implantation who underwent cardiac magnetic resonance for clinical proposes since February/2018 and in whom a 3D-LGE dataset was obtained. Patients with channelopathies (n=2) or inappropriate imaging quality (imaging artifacts; n=7) were excluded. Scar characterization using ADAS software was performed in 3D-LGE datasets in all but 16 patients, where 2D datasets were used. The primary endpoint was the composite of appropriate ICD therapy (classified as ATP or shock), sustained ventricular tachycardia or SCD. Results: A total of 116 patients were analysed (mean age 66 ± 14 years; 81% male; mean LVEF 34 ± 14%; 74 patients with ischemic and 42 with non-ischemic cardiomyopathy; 40 patients received a device in the setting of secondary prevention). During a median follow-up of 2.3 years (IQR 1.3 – 3.3 years) there were 23 events (18 appropriate ICD therapies [9 shocks and 9 ATP], 3 episodes of VT under the threshold for ICD therapy and 2 SCD). No statistically significant differences were found between patients with or without events in terms of scar mass, border zone (BZ) mass, BZ channels (BZC), BZC mass, number of channels detected, and scar heterogeneity (BZ mass / scar mass ratio) - all p values > 0.2 – Figure. Restricting the analysis to only primary prevention cases yielded similar results. Overall, 26 patients did not show any channel. Four of these (all with non-ischemic LGE) experienced an arrhythmic event, yielding a negative predictive value of 83% (95% CI 64-93%) for the absence of channels. Conclusion: In this cohort with still relatively limited follow-up duration, no single parameter reflecting scar tissue characterization was able to predict appropriate device therapies or sudden cardiac death.
- Open Access
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Using the 3D architecture of scar to predict life-threatening ventricular arrythmias - still a long way to go
Funding Acknowledgements: Type of funding sources: None. Background: Late gadolinium enhancement (LGE) has been proposed as an independent predictor of ventricular arrhythmias. Purpose: The purpose of this study was to assess if myocardial scar characterization could enhance the risk stratification for life-threatening arrhythmias and sudden cardiac death (SCD). Methods: We included patients with an indication for ICD or CRT-D implantation who underwent cardiac magnetic resonance for clinical proposes since February/2018 and in whom a 3D-LGE dataset was obtained. Patients with channelopathies (n=2) or inappropriate imaging quality (imaging artifacts; n=7) were excluded. Scar characterization using ADAS software was performed in 3D-LGE datasets in all but 5 patients, where 2D datasets were used. The primary endpoint was the composite of appropriate ICD therapy (classified as ATP or shock) or SCD. Results: A total of 75 patients were analysed (mean age 63 ± 13 years; 83% male; mean LVEF 31 ± 13%; 50 patients with ischemic and 25 with non-ischemic cardiomyopathy; 14 patients received a device in the setting of secondary prevention). During a median follow-up of 1.4 years (IQR 0.7 – 2.4 years) there were 15 events (12 appropriate ICD therapies [8 shocks and 4 ATP] and 3 SCD). No statistically significant differences were found between patients with or without events in terms of scar mass, border zone (BZ) mass, BZ channels (BZC), BZC mass, number of channels detected, and scar heterogeneity (BZ mass / scar mass ratio) - all p values > 0.2 – Figure. Restricting the analysis to only primary prevention cases yielded similar results. Overall, 11 patients did not show any channel. Two of these experienced an arrhythmic event, yielding a negative predictive value of 80% (95% CI 75-83%) for the absence of channels. Conclusion: In this cohort with still relatively limited follow-up duration, no single parameter reflecting scar tissue characterization was able to predict appropriate device therapies or sudden cardiac death.
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Open AccessUsing the 3D architecture of scar to predict life-threatening ventricular arrythmias - still a long way to go
Funding Acknowledgements: Type of funding sources: None. Background: Late gadolinium enhancement (LGE) has been proposed as an independent predictor of ventricular arrhythmias. Purpose: The purpose of this study was to assess if myocardial scar characterization could enhance the risk stratification for life-threatening arrhythmias and sudden cardiac death (SCD). Methods: We included patients with an indication for ICD or CRT-D implantation who underwent cardiac magnetic resonance for clinical proposes since February/2018 and in whom a 3D-LGE dataset was obtained. Patients with channelopathies (n=2) or inappropriate imaging quality (imaging artifacts; n=7) were excluded. Scar characterization using ADAS software was performed in 3D-LGE datasets in all but 5 patients, where 2D datasets were used. The primary endpoint was the composite of appropriate ICD therapy (classified as ATP or shock) or SCD. Results: A total of 75 patients were analysed (mean age 63 ± 13 years; 83% male; mean LVEF 31 ± 13%; 50 patients with ischemic and 25 with non-ischemic cardiomyopathy; 14 patients received a device in the setting of secondary prevention). During a median follow-up of 1.4 years (IQR 0.7 – 2.4 years) there were 15 events (12 appropriate ICD therapies [8 shocks and 4 ATP] and 3 SCD). No statistically significant differences were found between patients with or without events in terms of scar mass, border zone (BZ) mass, BZ channels (BZC), BZC mass, number of channels detected, and scar heterogeneity (BZ mass / scar mass ratio) - all p values > 0.2 – Figure. Restricting the analysis to only primary prevention cases yielded similar results. Overall, 11 patients did not show any channel. Two of these experienced an arrhythmic event, yielding a negative predictive value of 80% (95% CI 75-83%) for the absence of channels. Conclusion: In this cohort with still relatively limited follow-up duration, no single parameter reflecting scar tissue characterization was able to predict appropriate device therapies or sudden cardiac death.
- Open Access
- 21 January 2021
- Published by SMC Media in European Journal of Case Reports in Internal Medicine
- Vol. 8 (1) , 002161
Persistent Left Superior Vena Cava: A Finding After Central Venous Catheterization
Introduction: Persistence of the left superior vena cava (LSVC) is a rare anatomical variant in the general population with an estimated incidence of 0.3-0.5% in healthy individuals. Its diagnosis can be made incidentally after imaging control of central venous catheter (CVC) or other types of devices placements. Patient and Methods: We present the case of a patient with an acute disease which required central venous catheterization for the administration of intravenous chemotherapy. Results: Central venous catheterization proved difficult and after imaging control it revealed an unusual position of the catheter tip. Additional study to verify catheter tip position was performed and computed tomography (CT-scan) revealed the presence of a persistent left superior vena cava. The patient was then submitted to the planned treatment without any record of complications associated with CVC. Conclusion: Although uncommon the persistence of the LSVC can have an important impact in clinical practice, particularly when more invasive procedures are required. Its recognition is relevant in order to minimize the potential complications inherent to these procedures.
- 21 January 2021
- Published by SMC Media in European Journal of Case Reports in Internal Medicine
- Vol. 8 (1) , 002161
Open AccessPersistent Left Superior Vena Cava: A Finding After Central Venous Catheterization
Introduction: Persistence of the left superior vena cava (LSVC) is a rare anatomical variant in the general population with an estimated incidence of 0.3-0.5% in healthy individuals. Its diagnosis can be made incidentally after imaging control of central venous catheter (CVC) or other types of devices placements. Patient and Methods: We present the case of a patient with an acute disease which required central venous catheterization for the administration of intravenous chemotherapy. Results: Central venous catheterization proved difficult and after imaging control it revealed an unusual position of the catheter tip. Additional study to verify catheter tip position was performed and computed tomography (CT-scan) revealed the presence of a persistent left superior vena cava. The patient was then submitted to the planned treatment without any record of complications associated with CVC. Conclusion: Although uncommon the persistence of the LSVC can have an important impact in clinical practice, particularly when more invasive procedures are required. Its recognition is relevant in order to minimize the potential complications inherent to these procedures.
- Open Access
- 28 May 2020
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 31 (2) , 166-173
Analysis of a 10-year period of lead removal in a referral centre
OBJECTIVES: Our goal was to analyse all lead extraction procedures (transvenous or open surgery) performed in our centre and the short- and long-term follow-up data from these patients. METHODS: All lead extractions performed from 2008 to 2017 were retrospectively reviewed for patient characteristics and indications for device implantation; indications for lead extraction; techniques used; peri- and postprocedural complications and short- and long-term follow-up data. RESULTS: A total of 159 patients (282 leads) were included [age 70 (62–78) years; 72% men]. The median follow-up time was 57 (25–90) months. Patients with lead explants were excluded. The most common indication for lead removal was infection (77%). A surgical approach was necessary in 14 patients (9%) owing to unsuccessful transvenous removal (n = 3), large vegetation in the lead (n = 4), concomitant valvular endocarditis (n = 2), other indications for open surgery (n = 4) and complicated transvenous removal (n = 1). Removal was tried for 282 leads. Of those, 256 were completely removed. Clinical success was achieved in 155 individual patients (98%). Complications occurred in 6 patients: 3 persistent infections, 1 stroke and 2 blood vessel ruptures. The procedure-related mortality rate was 2% (n = 3). CONCLUSIONS: Lead removal was associated with a high success rate and low all-cause complication and mortality rates. Emergency surgery because of acute complications was rare, and open-heart surgery was most frequently elective and not associated with a worse outcome.
- 28 May 2020
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 31 (2) , 166-173
Open AccessAnalysis of a 10-year period of lead removal in a referral centre
OBJECTIVES: Our goal was to analyse all lead extraction procedures (transvenous or open surgery) performed in our centre and the short- and long-term follow-up data from these patients. METHODS: All lead extractions performed from 2008 to 2017 were retrospectively reviewed for patient characteristics and indications for device implantation; indications for lead extraction; techniques used; peri- and postprocedural complications and short- and long-term follow-up data. RESULTS: A total of 159 patients (282 leads) were included [age 70 (62–78) years; 72% men]. The median follow-up time was 57 (25–90) months. Patients with lead explants were excluded. The most common indication for lead removal was infection (77%). A surgical approach was necessary in 14 patients (9%) owing to unsuccessful transvenous removal (n = 3), large vegetation in the lead (n = 4), concomitant valvular endocarditis (n = 2), other indications for open surgery (n = 4) and complicated transvenous removal (n = 1). Removal was tried for 282 leads. Of those, 256 were completely removed. Clinical success was achieved in 155 individual patients (98%). Complications occurred in 6 patients: 3 persistent infections, 1 stroke and 2 blood vessel ruptures. The procedure-related mortality rate was 2% (n = 3). CONCLUSIONS: Lead removal was associated with a high success rate and low all-cause complication and mortality rates. Emergency surgery because of acute complications was rare, and open-heart surgery was most frequently elective and not associated with a worse outcome.
- Open Access
- 1 September 2019
- Published by Elsevier in Revista Portuguesa de Cardiologia (English Edition)
- Vol. 38 (9) , 675.e1-675.e5
Pacemaker lead as an iatrogenic cause of right heart failure: Case report
- 1 September 2019
- Published by Elsevier in Revista Portuguesa de Cardiologia (English Edition)
- Vol. 38 (9) , 675.e1-675.e5
Open AccessPacemaker lead as an iatrogenic cause of right heart failure: Case report
- Open Access
- 10 May 2018
- Published by Wiley in Case Reports in Gastrointestinal Medicine
- Vol. 2018, 1-4
Ascites in a Young Woman: A Rare Presentation of Eosinophilic Gastroenteritis
Introduction. Eosinophilic gastroenteritis (EGE) is a rare idiopathic disease that can affect one or more organs of the digestive tract. It has an estimated incidence of 1–20 cases per 100,000 patients. Klein et al. classified EGE into 3 subtypes: predominant mucosal, muscular, or subserosal. Clinical Case. We report a case of a 32-year-old woman, who presented with diffuse abdominal pain, nausea, postprandial infarction, diarrhea, and moderate ascites of three-week evolution. The rest of physical examination did not show alterations. The past medical history was unremarkable. Laboratory test results revealed peripheral blood eosinophilia. Abdominal CT scan revealed diffuse and concentric parietal thickening of the distal of esophagus, moderate volume ascites, and small bowel wall thickening and distension on the left quadrants. The paracentesis revealed 93.3% of eosinophils. The colon biopsies evidenced an increase in the number of eosinophils. Secondary causes of eosinophilia were excluded. The patient was treated with oral prednisolone 40 mg/day with immediate clinical and analytical improvement. Conclusion. Eosinophilic gastroenteritis is a rare condition with a nonspecific and highly variable clinical presentation, which requires a high level of clinical suspicion. It is a diagnosis of exclusion. Secondary causes of eosinophilia such as intestinal tuberculosis, parasitosis, and malignant neoplasms should be excluded.- 10 May 2018
- Published by Wiley in Case Reports in Gastrointestinal Medicine
- Vol. 2018, 1-4
Open AccessAscites in a Young Woman: A Rare Presentation of Eosinophilic Gastroenteritis
Introduction. Eosinophilic gastroenteritis (EGE) is a rare idiopathic disease that can affect one or more organs of the digestive tract. It has an estimated incidence of 1–20 cases per 100,000 patients. Klein et al. classified EGE into 3 subtypes: predominant mucosal, muscular, or subserosal. Clinical Case. We report a case of a 32-year-old woman, who presented with diffuse abdominal pain, nausea, postprandial infarction, diarrhea, and moderate ascites of three-week evolution. The rest of physical examination did not show alterations. The past medical history was unremarkable. Laboratory test results revealed peripheral blood eosinophilia. Abdominal CT scan revealed diffuse and concentric parietal thickening of the distal of esophagus, moderate volume ascites, and small bowel wall thickening and distension on the left quadrants. The paracentesis revealed 93.3% of eosinophils. The colon biopsies evidenced an increase in the number of eosinophils. Secondary causes of eosinophilia were excluded. The patient was treated with oral prednisolone 40 mg/day with immediate clinical and analytical improvement. Conclusion. Eosinophilic gastroenteritis is a rare condition with a nonspecific and highly variable clinical presentation, which requires a high level of clinical suspicion. It is a diagnosis of exclusion. Secondary causes of eosinophilia such as intestinal tuberculosis, parasitosis, and malignant neoplasms should be excluded. - 6 March 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 52 (1) , 39-45
Very long-term outcomes after a single catheter ablation procedure for the treatment of atrial fibrillation—the protective role of antiarrhythmic drug therapy
Pulmonary vein isolation (PVI) is the cornerstone of AF ablation, but its long-term clinical outcomes, predictors of relapse, and optimal pharmacological treatment remain controversial.
- 6 March 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 52 (1) , 39-45
Very long-term outcomes after a single catheter ablation procedure for the treatment of atrial fibrillation—the protective role of antiarrhythmic drug therapy
Pulmonary vein isolation (PVI) is the cornerstone of AF ablation, but its long-term clinical outcomes, predictors of relapse, and optimal pharmacological treatment remain controversial.
- Open Access
- 10 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (suppl_1) , i9
16-33: Long-term outcomes of ischemic ventricular tachycardia submitted to catheter ablation
Purpose: Catheter ablation for ventricular tachycardia (VT) has undergone a significant technical development in recent years . Electroanatomical mapping systems (EAM) have acutely improved the outcome of these procedures and helped in the prevention of VT recurrence. We analyzed how EAM influences treatment, prognosis, reduces ICD shocks and improves long-term prognosis. Methods: We retrospectively analysed the last 50 ischemic patients from our prospective registry up to December 2015. These patients underwent catheter ablation with a recent 3D cardiovascular navigation system (CARTO3 Biosense Webster, Diamond Bar, USA ) and used a pressure catheter (voltage criteria of >0.5-1.5mV). With the help of EAM, we determined the total area and volume of the left ventricle for each patient and the corresponding low voltage area (myocardial scar). The ablation was performed with an irrigated catheter with a 3.5mm sensor - SmartTouch ( Biosense Webster, Diamond Bar, USA ), guided by scar homogenization and by activation, whenever possible. Mean age was 68 ± 10years, 13 % female, and a median follow-up of 453 days. Summary: There was 1 serious complication and no deaths associated with the ablation procedure. There were 13 deaths (26%) and 1 heart transplant during the follow-up. Arrhythmic load was signicantly decreased with an average reduction of 2.5 shocks per year (p = 0.020). The absence of beta blockers, the width of the QTc interval and the number of shocks after ablation were all associated with higher mortality. Higher number of radiofrequency (RF) applications related to a increased risk of relapse, as well as the absence of RF applications in low-voltage areas. Multivariate Cox regression model revealed that the presence of atrial fibrillation, decreased ejection fraction, wider QRS, partial success of the catheter ablation and larger LV volume in the EAM were independent predictors of mortality. Conclusion: VT catheter ablation safely and significantly reduced the arrhythmic burden in this population. The inability to reduce arrhythmic load after ablation is associated with an increased mortality. The ablation of all the low-voltage territories appears to be necessary to reduce recurrence.
- 10 June 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (suppl_1) , i9
Open Access16-33: Long-term outcomes of ischemic ventricular tachycardia submitted to catheter ablation
Purpose: Catheter ablation for ventricular tachycardia (VT) has undergone a significant technical development in recent years . Electroanatomical mapping systems (EAM) have acutely improved the outcome of these procedures and helped in the prevention of VT recurrence. We analyzed how EAM influences treatment, prognosis, reduces ICD shocks and improves long-term prognosis. Methods: We retrospectively analysed the last 50 ischemic patients from our prospective registry up to December 2015. These patients underwent catheter ablation with a recent 3D cardiovascular navigation system (CARTO3 Biosense Webster, Diamond Bar, USA ) and used a pressure catheter (voltage criteria of >0.5-1.5mV). With the help of EAM, we determined the total area and volume of the left ventricle for each patient and the corresponding low voltage area (myocardial scar). The ablation was performed with an irrigated catheter with a 3.5mm sensor - SmartTouch ( Biosense Webster, Diamond Bar, USA ), guided by scar homogenization and by activation, whenever possible. Mean age was 68 ± 10years, 13 % female, and a median follow-up of 453 days. Summary: There was 1 serious complication and no deaths associated with the ablation procedure. There were 13 deaths (26%) and 1 heart transplant during the follow-up. Arrhythmic load was signicantly decreased with an average reduction of 2.5 shocks per year (p = 0.020). The absence of beta blockers, the width of the QTc interval and the number of shocks after ablation were all associated with higher mortality. Higher number of radiofrequency (RF) applications related to a increased risk of relapse, as well as the absence of RF applications in low-voltage areas. Multivariate Cox regression model revealed that the presence of atrial fibrillation, decreased ejection fraction, wider QRS, partial success of the catheter ablation and larger LV volume in the EAM were independent predictors of mortality. Conclusion: VT catheter ablation safely and significantly reduced the arrhythmic burden in this population. The inability to reduce arrhythmic load after ablation is associated with an increased mortality. The ablation of all the low-voltage territories appears to be necessary to reduce recurrence.