FSFlorian Stelzle

Florian Stelzle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Florian Stelzle has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optical nerve identification in head and neck surgery after Er:YAG laser ablation

    by Florian Stelzle, Christian Knipfer, Bastian Bergauer, Maximilian Rohde, Werner Adler, Katja Tangermann-Gerk, Emeka Nkenke, Michael Schmidt

    Facial nerve function may be hampered by iatrogenic damage during head and neck laser surgery procedures. Optical techniques can serve as a basis for feedback-controlled tissue-specific laser surgery on the jaw bone and the parotid gland. In order to preserve nerve tissue during laser surgery, the alteration of optical tissue properties through laser-tissue interactions have to be taken into account. It was the aim of this study to evaluate the viability of optical tissue differentiation through diffuse reflectance spectroscopy after exposure to laser light as a basis for a feedback system for tissue-specific laser surgery. Spectra of diffuse reflectance (wavelength, 350–650 nm) of nerves, salivary glands, and cortical and cancellous bone of the midfacial region (ex vivo domestic pig heads) were acquired before/after Er:YAG laser (wavelength, 2.94 μm) ablation (each 16,800 spectra). Principal component analysis was computed followed by quadratic discriminant analysis. The tissue classification performance as well as area under the curve (AUC) sensitivity and specificity for tissue differentiation was assessed before and after laser-tissue exposure. A high classification performance was observed before laser ablation (total error, 7.74 %). Nerve tissue was differentiated from bone and salivary glands with results greater than 0.96 in AUC, sensitivity and specificity. After laser exposure, a total classification error of 18.61 % was observed. The differentiation of nerve tissue was reduced with an AUC of >0.94, sensitivity of >0.95, and specificity >0.87. Er:YAG laser ablation only slightly reduces the differentiation performance through diffuse reflectance in the investigated tissue types. The results show the general viability of diffuse reflectance spectroscopy in identifying neural structures in the vicinity of salivary glands and bone as a basis for nerve preservation during feedback-controlled laser surgery.


  • Open Access

    Tissue Discrimination by Uncorrected Autofluorescence Spectra: A Proof-of-Principle Study for Tissue-Specific Laser Surgery

    by Florian Stelzle, Christian Knipfer, Werner Adler, Maximilian Rohde, Nicolai Oetter, Emeka Nkenke, Michael Schmidt, Katja Tangermann-Gerk

    Laser surgery provides a number of advantages over conventional surgery. However, it implies large risks for sensitive tissue structures due to its characteristic non-tissue-specific ablation. The present study investigates the discrimination of nine different ex vivo tissue types by using uncorrected (raw) autofluorescence spectra for the development of a remote feedback control system for tissue-selective laser surgery. Autofluorescence spectra (excitation wavelength 377 ± 50 nm) were measured from nine different ex vivo tissue types, obtained from 15 domestic pig cadavers. For data analysis, a wavelength range between 450 nm and 650 nm was investigated. Principal Component Analysis (PCA) and Quadratic Discriminant Analysis (QDA) were used to discriminate the tissue types. ROC analysis showed that PCA, followed by QDA, could differentiate all investigated tissue types with AUC results between 1.00 and 0.97. Sensitivity reached values between 93% and 100% and specificity values between 94% and 100%. This ex vivo study shows a high differentiation potential for physiological tissue types when performing autofluorescence spectroscopy followed by PCA and QDA. The uncorrected autofluorescence spectra are suitable for reliable tissue discrimination and have a high potential to meet the challenges necessary for an optical feedback system for tissue-specific laser surgery.


  • Dependence of the Capillary/Vessel Spatial Pattern Estimated by Measuring Diffuse Reflectance Spectra on the Hemoglobin Concentration Level

    by Rajesh Kanawade, Johannes Häuβermann, Florian Klämpfl, Michael Schmidt, Florian Stelzle

    The goal of this research is to study the behavior of the blood vessel density/spatial pattern estimated by measuring diffuce reflectance spectra depending on hemoglobin concentrations level for the application of early sign of the clinical shock detection.

  • The effect of load on heat production, thermal effects and expenditure of time during implant site preparation – an experimental ex vivo comparison between piezosurgery and conventional drilling

    by Florian Stelzle, Carsten Frenkel, Max Riemann, Christian Knipfer, Philipp Stockmann, Emeka Nkenke

    Piezoelectric surgery (PS) is meant to be a gentle osteotomy method. The aim of this study was to compare piezosurgical vs. conventional drilling methods for implant site preparation (ISP) - focusing on load-dependent thermal effect on hard tissue and the expenditure of ISP time. Three hundred and sixty ISP were performed on ex vivo pig heads using piezosurgery, spiral burs (SB) and trephine burs (TB). The load applied was increased from 0 to 1000 g in 100-g intervals. Temperature within the bone was measured with a thermocouple, and duration was recorded with a stop watch. Thermal effects were histomorphometrically analysed. Twelve ISPs per technique were performed at the lateral wall of the maxillary sinus. PS yields the highest mean temperatures (48.6 ± 3.4°C) and thermal effects (200.7 ± 44.4 μm), both at 900-1000 g. Duration is reduced with a plus of load and significantly longer in either case for PS (P < 0.05). There is a correlation of the applied load with all other examined factors for PS and TB. Temperature and histological effects decrease for SB beyond 500 g. PS yields significantly higher temperatures and thermal tissue alterations on load levels higher than 500 g and is significantly slower for ISP compared to SB and TB. For ISP with PS, a maximum load of 400 g should be maintained.


  • Open Access

    Acceptance of virtual dental implant planning software in an undergraduate curriculum: a pilot study

    by Emeka Nkenke, Elefterios Vairaktaris, Anne Bauersachs, Stephan Eitner, Alexander Budach, Christian Knipfer, Florian Stelzle

    Advances in healthcare such as virtual dental implant planning have the capacity to result in greater accuracy, speed, and efficiencies leading to improvement in patient care. It has been suggested that the acceptance of new technology is influenced by a variety of factors including individual differences, social and situational influences, user beliefs, and user attitudes. Despite the large volume of work in this area, only limited research has been conducted in the field of dental education. Therefore, the present study aimed at assessing the acceptance of virtual dental implant planning software by undergraduate students.


  • Open Access

    The impact of laser ablation on optical soft tissue differentiation for tissue specific laser surgery-an experimental ex vivo study

    by Florian Stelzle, Ingo Terwey, Christian Knipfer, Werner Adler, Katja Tangermann-Gerk, Emeka Nkenke, Michael Schmidt

    Optical diffuse reflectance can remotely differentiate various bio tissues. To implement this technique in an optical feedback system to guide laser surgery in a tissue-specific way, the alteration of optical tissue properties by laser ablation has to be taken into account. It was the aim of this study to evaluate the general feasibility of optical soft tissue differentiation by diffuse reflectance spectroscopy under the influence of laser ablation, comparing the tissue differentiation results before and after laser intervention.


    • 23 May 2012
      • Vol. 27  (3) , 513-22

    Load-dependent heat development, thermal effects, duration, and soft tissue preservation in piezosurgical implant site preparation: an experimental ex vivo study.

    by Florian Stelzle, Friedrich Wilhelm Neukam, Emeka Nkenke

    Piezoelectric surgery is meant to be a gentle method for implant site preparation (ISP). However, the application of load and its influence on heat development over time and effects on soft tissue are unknown. Therefore, this study sought to evaluate heat development in the bone and the duration of the procedure according to load application, as well as preservation of the sinus floor mucosa during piezoelectric ISP. One hundred twenty implant sites (6 mm deep x 3 mm wide) were prepared in the calvaria of ex vivo pig heads using piezoelectric surgery. The load applied to the working tip was increased in 100-g intervals up to 1,000 g. The bone temperature was measured, and thermal effects were analyzed histomorphometrically. The duration of each ISP was recorded. Another 12 ISPs were performed at the lateral wall of the maxillary sinus in the vicinity of the sinus floor mucosa, and sites were checked for perforation. Temperature and histologic effects of heat demonstrated a significant positive correlation with the applied load. The duration of ISP was significantly negatively correlated with load application. The maximum temperature generated by piezoelectric surgery was 64.5°C (load of 901 to 1,000 g). At a load of 401 to 500 g, the average temperature was 40.2°C ± 3.3°C, the average thermal damage extended 115.9 ± 16.3 Μm beyond the ISP area, and the maximum temperature did not exceed 47°C. The average duration of ISP using this load interval was 45.5 ± 9.4 seconds. Two perforations of the sinus floor mucosa were detected. In the present setting, the applied load during piezoelectric ISP should not exceed 500 g to prevent temperatures above 47°C in the bony implant socket. With a load of 400 to 500 g, ISP took 40 to 50 seconds.


  • Open Access

    Spaced education activates students in a theoretical radiological science course: a pilot study

    by Emeka Nkenke, Elefterios Vairaktaris, Anne Bauersachs, Stephan Eitner, Alexander Budach, Christian Knipfer, Florian Stelzle

    The present study aimed at determining if the addition of spaced education to traditional face-to-face lectures increased the time students kept busy with the learning content of a theoretical radiological science course.