Tomokazu Fukui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomokazu Fukui has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Shinichi Yoshiya
Department of Orthopaedic Surgery Nishinomiya Kaisei Hospital Nishinomiya Hyogo Japan
2 shared publications - Hiroki Yamanaka
Department of Anatomy and Neuroscience, Hyogo College of Medicine, Nishinomiya, Hyogo, Japan
1 shared publication - Hiroshi Kamo
Department of Physiology, School of Dentistry, Nihon University, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
1 shared publication - Kimiko Kobayashi
Department of Anatomy and Neuroscience, Hyogo College of Medicine, Nishinomiya, Hyogo 663-8501, Japan
1 shared publication - Koichi Iwata
Department of Physiology, Nihon University School of Dentistry, 1-8-13 Kandasurugadai, Chiyoda-ku, Tokyo 101-8310, Japan
1 shared publication - Koichi Noguchi
Hyogo Medical University, Laboratory of Pain Mechanism Research, Nishinomiya, Hyogo, Japan
1 shared publication
Latest Publications
- 11 October 2010
- Published by SLACK, Inc.
- Vol. 33 (10) , 38-42
Use of Image-Free Navigation in Determination of Acetabular Cup Orientation: Analysis of Factors Affecting Precision
Feature Article Tomokazu Fukui, MD; Shigeo Fukunishi, MD; Shoji Nishio, MD; Nao Shibanuma, MD; Shinichi Yoshiya, MD We have been using an image-free total hip arthroplasty (THA) navigation system (OrthoPilot; Aesculap, Tuttlingen, Germany) to ensure accurate and reproducible acetabular cup orientation. In this study, the accuracy of this system in the assessment of acetabular cup orientation was evaluated by comparing the intraoperative inclination and anteversion angles presented by the navigation system and the corresponding postoperative values obtained by computed tomography measurement. In the intraoperative accuracy analysis, we additionally examined the influence of factors such as body mass index and soft tissue thickness on assessment error. Intraoperative and postoperative results obtained from 115 consecutive navigated THAs were compared and analyzed. In both inclination and anteversion angles, good agreement was observed; a discrepancy of more than 5° was observed in 1 and 3 cases, respectively. In the analysis of factors potentially affecting the accuracy of the intraoperative assessment, no correlation between each parameter and the intraoperative and postoperative discrepancy was demonstrated. Drs Fukui, Fukunishi, Nishio, and Yoshiya are from the Department of Orthopaedic Surgery, Hyogo College of Medicine, Nishinomiya, and Dr Shibanuma is from the Department of Orthopaedic Surgery, Kobe Kaisei Hospital, Kobe, Japan. Drs Fukui, Fukunishi, Nishio, Shibanuma, and Yoshiya have no relevant financial relationships to disclose. Correspondence should be addressed to: Tomokazu Fukui, MD, Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho Nishinomiya, Hyogo 663-8501, Japan. Use of a computer-assisted navigation system in total hip arthroplasty (THA) has been introduced with expectations of achieving optimum implant alignment.1–8 Current THA navigation systems can be divided into 2 groups based on the operation principle: image-based or image-free. In the image-free system, the position and orientation of the patient’s pelvis are recognized intraoperatively by palpation and registration of the bony landmarks. Thus, a discrepancy between the locations of the bony landmark and the registered point may cause assessment errors. In several clinical studies, the accuracy of the image-free THA navigation system has been assessed and reported.3–5,9–12 In most studies, satisfactory agreement between the intraoperative navigation results and the postoperative values obtained from radiologic examination has been reported.3–5,13,14 We have been using the OrthoPilot image-free navigation system (B. Braun Aesculap, Tuttlingen, Germany) since 2006. In order to examine the accuracy and potential source of error in the use of this navigation system, we conducted a study comparing the intraoperative cup positioning angles shown by the navigation and the corresponding values calculated from postoperative computed tomography (CT) data. In the CT evaluation, we analyzed Digital Imaging and Communications in Medicine (DICOM) data using the Medical Image Processing, Analysis and Visualization (MIPAV) computer program developed by the National Institutes of Health (Bethesda, Maryland), which allows the consistent creation of an analysis coordinate system.15,16 We reported preliminary results of the analysis for the initial 25 THAs in 2008.17 Although a reasonably high accuracy with the use of this system was observed, the small sample size in the study precluded us from analyzing the factors affecting the accuracy and presenting a conclusive statement. One of the potential factors leading to assessment error in the use of the image-free system is inaccurate localization of the bony landmarks.12,18,19 In particular, the presence of thick subcutaneous tissue in an obese patient can cause a discrepancy. In this study, we increased the number of patients and examined the effects of soft tissue on assessment error in the intraoperative evaluation. Moreover, it was expected that the accuracy of this system could be more substantially assessed than in our previous report17 due to the analysis of a larger patient population. In 2005, we began using the OrthoPilot CT-free navigation system. After an initial series of 38 hips, we designed and started this study in April 2006 after approval by the Institutional Review Board and with informed consent from the patients. From April 2006 to March 2008, both acetabular alignment data based on navigation system and acetabular alignment data based on postoperative CT evaluation were obtained and compared in 115 consecutive navigated THAs in 110 patients. Mean patient age was 63.4 years (range, 21–88 years). Fifteen patients were men and 95 were women. Preoperative diagnosis was osteoarthritis in 85, osteonecrosis in 25, rheumatoid arthritis in 3, and hemophilic arthropathy in 2 patients. Preoperatively, 2 metal markers were attached to the bilateral anterosuperior iliac spines, and the location of the markers was confirmed by a plain anteroposterior pelvic radiograph (Figure 1). These markers showed the location of the bony landmarks both in the intraoperative and postoperative evaluations. Before surgery, the tracker was inserted and fixed to the iliac crest through a stab incision with the patient in the supine position. As the anatomic landmarks, the bilateral anterosuperior iliac spines and the upper margin of the symphysis were located by percutaneous palpation of the markers and bony prominence. The reference plane in the analysis was...
- 11 October 2010
- Published by SLACK, Inc.
- Vol. 33 (10) , 38-42
Use of Image-Free Navigation in Determination of Acetabular Cup Orientation: Analysis of Factors Affecting Precision
Feature Article Tomokazu Fukui, MD; Shigeo Fukunishi, MD; Shoji Nishio, MD; Nao Shibanuma, MD; Shinichi Yoshiya, MD We have been using an image-free total hip arthroplasty (THA) navigation system (OrthoPilot; Aesculap, Tuttlingen, Germany) to ensure accurate and reproducible acetabular cup orientation. In this study, the accuracy of this system in the assessment of acetabular cup orientation was evaluated by comparing the intraoperative inclination and anteversion angles presented by the navigation system and the corresponding postoperative values obtained by computed tomography measurement. In the intraoperative accuracy analysis, we additionally examined the influence of factors such as body mass index and soft tissue thickness on assessment error. Intraoperative and postoperative results obtained from 115 consecutive navigated THAs were compared and analyzed. In both inclination and anteversion angles, good agreement was observed; a discrepancy of more than 5° was observed in 1 and 3 cases, respectively. In the analysis of factors potentially affecting the accuracy of the intraoperative assessment, no correlation between each parameter and the intraoperative and postoperative discrepancy was demonstrated. Drs Fukui, Fukunishi, Nishio, and Yoshiya are from the Department of Orthopaedic Surgery, Hyogo College of Medicine, Nishinomiya, and Dr Shibanuma is from the Department of Orthopaedic Surgery, Kobe Kaisei Hospital, Kobe, Japan. Drs Fukui, Fukunishi, Nishio, Shibanuma, and Yoshiya have no relevant financial relationships to disclose. Correspondence should be addressed to: Tomokazu Fukui, MD, Department of Orthopaedic Surgery, Hyogo College of Medicine, 1-1 Mukogawa-cho Nishinomiya, Hyogo 663-8501, Japan. Use of a computer-assisted navigation system in total hip arthroplasty (THA) has been introduced with expectations of achieving optimum implant alignment.1–8 Current THA navigation systems can be divided into 2 groups based on the operation principle: image-based or image-free. In the image-free system, the position and orientation of the patient’s pelvis are recognized intraoperatively by palpation and registration of the bony landmarks. Thus, a discrepancy between the locations of the bony landmark and the registered point may cause assessment errors. In several clinical studies, the accuracy of the image-free THA navigation system has been assessed and reported.3–5,9–12 In most studies, satisfactory agreement between the intraoperative navigation results and the postoperative values obtained from radiologic examination has been reported.3–5,13,14 We have been using the OrthoPilot image-free navigation system (B. Braun Aesculap, Tuttlingen, Germany) since 2006. In order to examine the accuracy and potential source of error in the use of this navigation system, we conducted a study comparing the intraoperative cup positioning angles shown by the navigation and the corresponding values calculated from postoperative computed tomography (CT) data. In the CT evaluation, we analyzed Digital Imaging and Communications in Medicine (DICOM) data using the Medical Image Processing, Analysis and Visualization (MIPAV) computer program developed by the National Institutes of Health (Bethesda, Maryland), which allows the consistent creation of an analysis coordinate system.15,16 We reported preliminary results of the analysis for the initial 25 THAs in 2008.17 Although a reasonably high accuracy with the use of this system was observed, the small sample size in the study precluded us from analyzing the factors affecting the accuracy and presenting a conclusive statement. One of the potential factors leading to assessment error in the use of the image-free system is inaccurate localization of the bony landmarks.12,18,19 In particular, the presence of thick subcutaneous tissue in an obese patient can cause a discrepancy. In this study, we increased the number of patients and examined the effects of soft tissue on assessment error in the intraoperative evaluation. Moreover, it was expected that the accuracy of this system could be more substantially assessed than in our previous report17 due to the analysis of a larger patient population. In 2005, we began using the OrthoPilot CT-free navigation system. After an initial series of 38 hips, we designed and started this study in April 2006 after approval by the Institutional Review Board and with informed consent from the patients. From April 2006 to March 2008, both acetabular alignment data based on navigation system and acetabular alignment data based on postoperative CT evaluation were obtained and compared in 115 consecutive navigated THAs in 110 patients. Mean patient age was 63.4 years (range, 21–88 years). Fifteen patients were men and 95 were women. Preoperative diagnosis was osteoarthritis in 85, osteonecrosis in 25, rheumatoid arthritis in 3, and hemophilic arthropathy in 2 patients. Preoperatively, 2 metal markers were attached to the bilateral anterosuperior iliac spines, and the location of the markers was confirmed by a plain anteroposterior pelvic radiograph (Figure 1). These markers showed the location of the bony landmarks both in the intraoperative and postoperative evaluations. Before surgery, the tracker was inserted and fixed to the iliac crest through a stab incision with the patient in the supine position. As the anatomic landmarks, the bilateral anterosuperior iliac spines and the upper margin of the symphysis were located by percutaneous palpation of the markers and bony prominence. The reference plane in the analysis was...
- Open Access
- 1 January 2007
- Published by SAGE Publications in Molecular Pain
- Vol. 3, 18
Frequency-Dependent ERK Phosphorylation in Spinal Neurons by Electric Stimulation of the Sciatic Nerve and the Role in Electrophysiological Activity
The phosphorylation of extracellular signal-regulated kinase (pERK) in DRG and dorsal horn neurons is induced by the C-fiber electrical stimulation to the peripheral nerve. The present study was designed to investigate the expression and modulation of pERK in the rat dorsal horn neurons produced by repetitive electrical stimulation, and its involvement in the electrophysiological activity of dorsal horn neurons. Electrical stimulation of C-fiber intensity at different frequencies was applied to the sciatic nerve; the stimuli-induced pERK expression and the activity in dorsal horn neurons were studied by immunohistochemistry and extracellular recording, respectively. Electrical stimulation of C-fibers (3 mA) induced pERK expression in dorsal horn neurons in a frequency-dependent manner, indicating that the frequency of electrical stimulation is an important factor which activates the intracellular signal pathway in the spinal cord. To demonstrate the underlying mechanism of this frequency-dependent pERK expression, an NMDA receptor antagonist, MK-801, and a voltage sensitive calcium channel antagonist, nifedipine, were administrated intrathecally before the stimulation. We found that high frequency (0.5 Hz and 10 Hz) but not low frequent (0.05 Hz) stimulus-evoked pERK was partially inhibited by MK-801. Both high and low frequency stimulus-evoked pERK were inhibited by the nifedipine treatment. The extracellular single unit activities were recorded from the laminae I-II and V of the L4-5 dorsal horn, and we found that blockage of the intracellular ERK signal suppressed the wind-up responses in a dose-dependent manner. In contrast, any change in the mechanically evoked responses was not observed following the administration of ERK inhibitor. These observations indicate that ERK activation plays an important role in the induction of the wind-up responses in dorsal horn nociceptive neurons.
- 1 January 2007
- Published by SAGE Publications in Molecular Pain
- Vol. 3, 18
Open AccessFrequency-Dependent ERK Phosphorylation in Spinal Neurons by Electric Stimulation of the Sciatic Nerve and the Role in Electrophysiological Activity
The phosphorylation of extracellular signal-regulated kinase (pERK) in DRG and dorsal horn neurons is induced by the C-fiber electrical stimulation to the peripheral nerve. The present study was designed to investigate the expression and modulation of pERK in the rat dorsal horn neurons produced by repetitive electrical stimulation, and its involvement in the electrophysiological activity of dorsal horn neurons. Electrical stimulation of C-fiber intensity at different frequencies was applied to the sciatic nerve; the stimuli-induced pERK expression and the activity in dorsal horn neurons were studied by immunohistochemistry and extracellular recording, respectively. Electrical stimulation of C-fibers (3 mA) induced pERK expression in dorsal horn neurons in a frequency-dependent manner, indicating that the frequency of electrical stimulation is an important factor which activates the intracellular signal pathway in the spinal cord. To demonstrate the underlying mechanism of this frequency-dependent pERK expression, an NMDA receptor antagonist, MK-801, and a voltage sensitive calcium channel antagonist, nifedipine, were administrated intrathecally before the stimulation. We found that high frequency (0.5 Hz and 10 Hz) but not low frequent (0.05 Hz) stimulus-evoked pERK was partially inhibited by MK-801. Both high and low frequency stimulus-evoked pERK were inhibited by the nifedipine treatment. The extracellular single unit activities were recorded from the laminae I-II and V of the L4-5 dorsal horn, and we found that blockage of the intracellular ERK signal suppressed the wind-up responses in a dose-dependent manner. In contrast, any change in the mechanically evoked responses was not observed following the administration of ERK inhibitor. These observations indicate that ERK activation plays an important role in the induction of the wind-up responses in dorsal horn nociceptive neurons.