Manuel Nienkemper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manuel Nienkemper has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Dieter Drescher
Department of Orthodontics, University of Homburg, Saar, Germany
16 shared publications - Benedict Wilmes
Department of Orthodontics, University of Düsseldorf, Düsseldorf, Germany.
14 shared publications - Björn Ludwig
Department of Orthodontics, University of Homburg, Saar, Germany; Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Private Practice of Orthodontics in Traben-Trarbach, Germany.
7 shared publications Dieter Drescher
Department of Orthodontics, Heinrich-Heine University, Moorenstrasse 5, 40225, Düsseldorf, Germany
7 shared publications- Alexander Pauls
Kieferorthopädische Fachpraxis, Baden-Baden
6 shared publications Benedict Wilmes
B Associate Professor, Department of Orthodontics, Heinrich-Heine-University, Düsseldorf, Germany
5 shared publications
Latest Publications
- Open Access
- 17 February 2020
- Published by Springer Nature in Progress in Orthodontics
- Vol. 21 (1) , 1-7
RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period
Background: In dental implantology, the development of stability over time is a well-investigated topic. In case of orthodontic mini-implants, quantitative data for long-term stability is not available yet. This study aims to clinically investigate the long-term stability of mini-implants inserted in the midsagittal suture of the anterior palate. Moreover, the influence of the length of implants was elucidated. The stability of 2 × 9 and 2 × 11 mm mini-implants after orthodontic treatment (9 mm, 2.84 years ± 1.25 years; 11 mm, 3.17 years ± 0.96 years) was assessed by resonance frequency analysis (RFA). The obtained long-term pieces of data were compared with each other (9 mm vs 11 mm), as well as with the data from the matched early stability groups, to assess the initial and early secondary stability after the insertion from previous clinical trials. Results: For both lengths, the long-term stability (2 × 9 mm, 25.12 ± 7.11, n = 21; 2 × 11 mm, 24.39 ± 5.82, n = 18) was significantly lower than primary stability (2 × 9 mm, 36.14 ± 6.08, n = 19; 2 × 11 mm, 33.35 ± 3.53, n = 20). The differences within the groups disappeared over the initial healing period: after 4 weeks for the 2 × 9 mm implants and after 2 weeks for the 2 × 11 mm implants. Also, the 2 × 9 mm and 2 × 11 mm implants showed comparable long-term stability values. Conclusion: The stability of midpalatal mini-implants does not change in the long term after the initial healing period. Moreover, 2 × 9 mm mini-implants seem to be appropriate for orthodontic anchorage, as the stability of 2 × 11 mm implants is not higher. Therefore, owing to lower invasiveness, 2 × 9 mm implants should be preferred.
- 17 February 2020
- Published by Springer Nature in Progress in Orthodontics
- Vol. 21 (1) , 1-7
Open AccessRFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period
Background: In dental implantology, the development of stability over time is a well-investigated topic. In case of orthodontic mini-implants, quantitative data for long-term stability is not available yet. This study aims to clinically investigate the long-term stability of mini-implants inserted in the midsagittal suture of the anterior palate. Moreover, the influence of the length of implants was elucidated. The stability of 2 × 9 and 2 × 11 mm mini-implants after orthodontic treatment (9 mm, 2.84 years ± 1.25 years; 11 mm, 3.17 years ± 0.96 years) was assessed by resonance frequency analysis (RFA). The obtained long-term pieces of data were compared with each other (9 mm vs 11 mm), as well as with the data from the matched early stability groups, to assess the initial and early secondary stability after the insertion from previous clinical trials. Results: For both lengths, the long-term stability (2 × 9 mm, 25.12 ± 7.11, n = 21; 2 × 11 mm, 24.39 ± 5.82, n = 18) was significantly lower than primary stability (2 × 9 mm, 36.14 ± 6.08, n = 19; 2 × 11 mm, 33.35 ± 3.53, n = 20). The differences within the groups disappeared over the initial healing period: after 4 weeks for the 2 × 9 mm implants and after 2 weeks for the 2 × 11 mm implants. Also, the 2 × 9 mm and 2 × 11 mm implants showed comparable long-term stability values. Conclusion: The stability of midpalatal mini-implants does not change in the long term after the initial healing period. Moreover, 2 × 9 mm mini-implants seem to be appropriate for orthodontic anchorage, as the stability of 2 × 11 mm implants is not higher. Therefore, owing to lower invasiveness, 2 × 9 mm implants should be preferred.
- Open Access
- 22 October 2018
- Published by Springer Nature in Progress in Orthodontics
- Vol. 19 (1) , 1-8
Early Class III treatment with Hybrid-Hyrax -Facemask in comparison to Hybrid-Hyrax-Mentoplate – skeletal and dental outcomes
Protraction of maxilla is usually the preferred and more commonly used treatment approach for skeletal Class III with a retrognathic maxilla. The aim of this study was the comparison of the skeletal and dental effects of two skeletally borne appliances for maxillary protraction: a) Hybrid-Hyrax in combination with facemask (FM), b) Hybrid-Hyrax in combination with Mentoplate (ME). Thirty four Patients (17 facemask, 17 Mentoplate) were investigated by means of pre- and posttreatment cephalograms. The two groups matched with regard to treatment time, age gender and type of dentoskeletal deformity before treatment. Both groups showed a significant forward movement of A-point (FM GROUP: SNA + 2.23° ± 1.30°— p 0.000*; ME: 2.23° ± 1.43°— p 0.000*). B-Point showed a larger sagittal change in the FM Group (SNB 1.51° ± 1.1°— p 0.000*) compared to the ME group (SNB: − 0.30° ± 0.9°— p 0.070). The FM group showed a significant increase of the ML-NL + 1.86° ± 1.65° (p 0.000*) and NSL-ML + 1.17° ± 1.48 (p 0.006*). Upper Incisor inclination did not change significantly during treatment in both groups as well as the distance of the first upper Molar in relation to A-point. Both treatments achieve comparable rates of maxillary protraction, without dentoalveolar side effects. Skeletal anchorage with symphysial plates in the mandible provides greater vertical control and might be the treatment of choice in high angle patients.
- 22 October 2018
- Published by Springer Nature in Progress in Orthodontics
- Vol. 19 (1) , 1-8
Open AccessEarly Class III treatment with Hybrid-Hyrax -Facemask in comparison to Hybrid-Hyrax-Mentoplate – skeletal and dental outcomes
Protraction of maxilla is usually the preferred and more commonly used treatment approach for skeletal Class III with a retrognathic maxilla. The aim of this study was the comparison of the skeletal and dental effects of two skeletally borne appliances for maxillary protraction: a) Hybrid-Hyrax in combination with facemask (FM), b) Hybrid-Hyrax in combination with Mentoplate (ME). Thirty four Patients (17 facemask, 17 Mentoplate) were investigated by means of pre- and posttreatment cephalograms. The two groups matched with regard to treatment time, age gender and type of dentoskeletal deformity before treatment. Both groups showed a significant forward movement of A-point (FM GROUP: SNA + 2.23° ± 1.30°— p 0.000*; ME: 2.23° ± 1.43°— p 0.000*). B-Point showed a larger sagittal change in the FM Group (SNB 1.51° ± 1.1°— p 0.000*) compared to the ME group (SNB: − 0.30° ± 0.9°— p 0.070). The FM group showed a significant increase of the ML-NL + 1.86° ± 1.65° (p 0.000*) and NSL-ML + 1.17° ± 1.48 (p 0.006*). Upper Incisor inclination did not change significantly during treatment in both groups as well as the distance of the first upper Molar in relation to A-point. Both treatments achieve comparable rates of maxillary protraction, without dentoalveolar side effects. Skeletal anchorage with symphysial plates in the mandible provides greater vertical control and might be the treatment of choice in high angle patients.
- 20 December 2017
- Published by Georg Thieme Verlag KG in Informationen aus Orthodontie & Kieferorthopädie
- Vol. 49 (04) , 234-236
Der Beneslider
Der Beneslider ist eine auf 2 palatinalen Mini-Implantaten (Benefit-System, psm Medical Solutions, Tuttlingen, Deutschland) befestigte Apparatur zur Distalisierung oberer Molaren [1]. Zur Anwendung kommen Mini-Implantate mit einem Innengewinde in den Abmessungen 9×2 mm. Als Insertionsregion bietet sich der anteriore Gaumen median aufgrund von hoher Knochenqualität und ausreichendem Knochenangebot an [2] [3]. Die Distalisierung erfolgt mittels Gleitmechanik auf einem rigiden Stahldraht (1,1 mm) (Beneplate). Nach Insertion der Schrauben sowie der Bänder auf den ersten Molaren wird mittels Abdruckkappen und Transfersystem für die Palatinalschlösser ein Abdruck des Oberkiefers mit Alginat oder Silikon angefertigt. Die in die Abdruckkappen gesteckten Laborimplantate sowie die Übertragungselemente des Transfersystems werden ausgewachst und ein Gipsmodell erstellt ([Abb. 1a–d]).
- 20 December 2017
- Published by Georg Thieme Verlag KG in Informationen aus Orthodontie & Kieferorthopädie
- Vol. 49 (04) , 234-236
Der Beneslider
Der Beneslider ist eine auf 2 palatinalen Mini-Implantaten (Benefit-System, psm Medical Solutions, Tuttlingen, Deutschland) befestigte Apparatur zur Distalisierung oberer Molaren [1]. Zur Anwendung kommen Mini-Implantate mit einem Innengewinde in den Abmessungen 9×2 mm. Als Insertionsregion bietet sich der anteriore Gaumen median aufgrund von hoher Knochenqualität und ausreichendem Knochenangebot an [2] [3]. Die Distalisierung erfolgt mittels Gleitmechanik auf einem rigiden Stahldraht (1,1 mm) (Beneplate). Nach Insertion der Schrauben sowie der Bänder auf den ersten Molaren wird mittels Abdruckkappen und Transfersystem für die Palatinalschlösser ein Abdruck des Oberkiefers mit Alginat oder Silikon angefertigt. Die in die Abdruckkappen gesteckten Laborimplantate sowie die Übertragungselemente des Transfersystems werden ausgewachst und ein Gipsmodell erstellt ([Abb. 1a–d]).
- 1 July 2016
- Vol. 50 (7) , 420-6
Uprighting Mesially Impacted Lower Third Molars with Skeletal Anchorage.
- 1 July 2016
- Vol. 50 (7) , 420-6
Uprighting Mesially Impacted Lower Third Molars with Skeletal Anchorage.
- 7 June 2016
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 77 (4) , 296-303
Orthodontic mini-implant stability at different insertion depths
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 × 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest®. Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1–100], which increased from 6.95 ± 2.85 ISQ at 4 mm to 34.63 ± 5.51 ISQ at 8 mm, and with those of Periotest® [periotest values (PTV) range from −8 to 50], which decreased from 13.24 ± 4.03 PTV to −2.89 ± 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 ± 69.32 Nmm to 261 ± 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest® values were highly correlated (r = −0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest® yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
- 7 June 2016
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 77 (4) , 296-303
Orthodontic mini-implant stability at different insertion depths
The purpose of this work was to evaluate the influence of insertion depth on the stability of orthodontic mini-implants. Sensitivity of three different methods to measure implant stability based on differences in insertion depth were determined. A total of 82 mini-implants (2 × 9 mm) were inserted into pelvic bone of Swabian Hall pigs. Each implant was inserted stepwise to depths of 4, 5, 6, 7, and 8 mm. At each of these depths, three different methods were used to measure implant stability, including maximum insertion torque (MIT), resonance frequency analysis (RFA), and Periotest®. Differences between the recorded values were statistically analyzed and the methods tested for correlations. Almost linear changes from each insertion depth were measured with the values of RFA [implant stability quotient (ISQ) values range from 1–100], which increased from 6.95 ± 2.85 ISQ at 4 mm to 34.63 ± 5.51 ISQ at 8 mm, and with those of Periotest® [periotest values (PTV) range from −8 to 50], which decreased from 13.24 ± 4.03 PTV to −2.89 ± 1.87 PTV. Both methods were found to record highly significant (p < 0.0001) changes for each additional millimeter of insertion depth. The MIT increased significantly (p < 0.0001) from 153.67 ± 69.32 Nmm to 261 ± 103.73 Nmm between 4 and 5 mm of insertion depth but no further significant changes were observed as the implants were driven deeper. The RFA and Periotest® values were highly correlated (r = −0.907). Mini-implant stability varies significantly with insertion depth. The RFA and the Periotest® yielded a linear relationship between stability and insertion depth. MIT does not appear to be an adequate method to determine implant stability based on insertion depth.
- 1 September 2015
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 85 (5) , 764-770
Effectiveness of maxillary protraction using a hybrid hyrax-facemask combination: A controlled clinical study
Objective: : To evaluate the treatment effects of a hybrid hyrax-facemask (FM) combination in growing Class III patients. Material and Methods: : A sample of 16 prepubertal patients (mean age, 9.5 ± 1.6 years) was investigated by means of pre- and posttreatment cephalograms. The treatment comprised rapid palatal expansion with a hybrid hyrax, a bone- and toothborne device. Simultaneously, maxillary protraction using an FM was performed. Mean treatment duration was 5.8 ± 1.6 months. The treatment group was compared with a matched control group of 16 untreated Class III subjects. Statistical comparisons were performed with the Mann-Whitney U -test. Results: : Significant improvement in skeletal sagittal values could be observed in the treatment group over controls: SNA: 2.4°, SNB: −1.7°, Co-Gn: −2.3 mm, Wits appraisal: 4.5 mm. Regarding vertical changes, maintenance of vertical growth was obtained as shown by a small nonsignificant increase of FMA and a small significant decrease of the Co-Go-Me angle. Conclusions: : The hybrid hyrax-FM combination was found to be effective for orthopedic treatment in growing Class III patients in the short term. Favorable skeletal changes were observed both in the maxilla and in the mandible. No dentoalveolar compensations were found.
- 1 September 2015
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 85 (5) , 764-770
Effectiveness of maxillary protraction using a hybrid hyrax-facemask combination: A controlled clinical study
Objective: : To evaluate the treatment effects of a hybrid hyrax-facemask (FM) combination in growing Class III patients. Material and Methods: : A sample of 16 prepubertal patients (mean age, 9.5 ± 1.6 years) was investigated by means of pre- and posttreatment cephalograms. The treatment comprised rapid palatal expansion with a hybrid hyrax, a bone- and toothborne device. Simultaneously, maxillary protraction using an FM was performed. Mean treatment duration was 5.8 ± 1.6 months. The treatment group was compared with a matched control group of 16 untreated Class III subjects. Statistical comparisons were performed with the Mann-Whitney U -test. Results: : Significant improvement in skeletal sagittal values could be observed in the treatment group over controls: SNA: 2.4°, SNB: −1.7°, Co-Gn: −2.3 mm, Wits appraisal: 4.5 mm. Regarding vertical changes, maintenance of vertical growth was obtained as shown by a small nonsignificant increase of FMA and a small significant decrease of the Co-Go-Me angle. Conclusions: : The hybrid hyrax-FM combination was found to be effective for orthopedic treatment in growing Class III patients in the short term. Favorable skeletal changes were observed both in the maxilla and in the mandible. No dentoalveolar compensations were found.
- 2 March 2014
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 75 (2) , 118-132
Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption
The aim of this study was to evaluate the efficiency of molar distalization depending on age and second-molar eruption using the Beneslider. Treatment of 51 patients (mean age 17.8 ± 9.6 years) was investigated retrospectively by means of pre- and posttreatment cephalograms. Patients were divided into three groups: 14 children with unerupted upper second molars (group 1), 23 adolescents with second molar in place (group 2), and 14 adults (group 3). The distalization forces applied were 2.4 N in group 1 and 5.0 N in groups 2 and 3. Treatment changes were evaluated and examined statistically for significant differences. In all patients a Class I molar relationship was achieved. All mini-implants remained stable during treatment. Mean distalization distance as measured by the displacement of the center of resistance was 3.6 ± 1.9 mm (range 1.2–8.5 mm depending on treatment needs). Since no significant tipping was detected, the type of movement can be described as bodily movement. Mean overall distalization speed was 0.6 ± 0.4 mm per month. There were no statistical differences between the groups. We found the Beneslider to be an effective appliance that enables bodily distalization in adequate treatment time. The higher resistance due to erupted second molars can be compensated by the use of higher forces without significantly reducing distalization speed. Ziel dieser Studie war die Überprüfung der Effizienz der Distalisierung oberer Molaren mittels des Benesliders in Abhängigkeit vom Alter der Patienten und dem Durchbruchsstadium der zweiten Molaren. Evaluiert wurde die Behandlung von 51 Patienten (Durchschnittsalter 17,8 ± 9,6 Jahre). Die Effekte der Distalisierung wurden mithilfe von prä- und posttherapeutischen Fernröntgenseitenbildern untersucht. Es erfolgte eine Gruppeneinteilung in Kinder ohne durchgebrochene obere zweite Molaren (Gruppe 1, n = 14), Jugendliche mit durchgebrochenen oberen zweiten Molaren (Gruppe 2, n = 23) und Erwachsene (Gruppe 3, n = 14). In Gruppe 1 wurden zur Distalisierung Kräfte von 2,4 N, in den Gruppen 2 und 3 von 5 N appliziert. Die Veränderungen wurden anhand der Fernröntgenseitenbilder ausgewertet und hinsichtlich statistisch signifikanter Unterschiede untersucht. Bei allen Patienten konnte eine Klasse-I-Verzahnung erreicht werden. Alle inserierten Miniimplantate verblieben während der gesamten Behandlung stabil. Die Distalisierungsstrecke wurde anhand der Bewegung des Widerstandszentrums der oberen ersten Molaren festgestellt und betrug durchschnittlich 3,6 ± 1,9 mm. Das Ausmaß der Distalisierung variierte befundbezogen zwischen 1,2 und 8,5 mm. Es handelte sich um eine nahezu körperliche Bewegung der Molaren, eine signifikante Kippung konnte nicht beobachtet werden. Über die gesamte Behandlungszeit wurde eine Distalisierungsgeschwindigkeit von 0,6 ± 0,4 mm pro Monat festgestellt. Signifikante Unterschiede zwischen den Gruppen gab es nicht. Mittels Beneslider wurde eine effektive und körperliche Molarendistalisierung in angemessener Behandlungsdauer erreicht. Der höhere Widerstand, den durchgebrochene zweite Molaren bewirken, kann durch eine Steigerung der applizierten Kräfte ausgeglichen werden. Eine signifikante Verringerung der Distalisierungsgeschwindigkeit konnte vermieden werden.
- 2 March 2014
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 75 (2) , 118-132
Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption
The aim of this study was to evaluate the efficiency of molar distalization depending on age and second-molar eruption using the Beneslider. Treatment of 51 patients (mean age 17.8 ± 9.6 years) was investigated retrospectively by means of pre- and posttreatment cephalograms. Patients were divided into three groups: 14 children with unerupted upper second molars (group 1), 23 adolescents with second molar in place (group 2), and 14 adults (group 3). The distalization forces applied were 2.4 N in group 1 and 5.0 N in groups 2 and 3. Treatment changes were evaluated and examined statistically for significant differences. In all patients a Class I molar relationship was achieved. All mini-implants remained stable during treatment. Mean distalization distance as measured by the displacement of the center of resistance was 3.6 ± 1.9 mm (range 1.2–8.5 mm depending on treatment needs). Since no significant tipping was detected, the type of movement can be described as bodily movement. Mean overall distalization speed was 0.6 ± 0.4 mm per month. There were no statistical differences between the groups. We found the Beneslider to be an effective appliance that enables bodily distalization in adequate treatment time. The higher resistance due to erupted second molars can be compensated by the use of higher forces without significantly reducing distalization speed. Ziel dieser Studie war die Überprüfung der Effizienz der Distalisierung oberer Molaren mittels des Benesliders in Abhängigkeit vom Alter der Patienten und dem Durchbruchsstadium der zweiten Molaren. Evaluiert wurde die Behandlung von 51 Patienten (Durchschnittsalter 17,8 ± 9,6 Jahre). Die Effekte der Distalisierung wurden mithilfe von prä- und posttherapeutischen Fernröntgenseitenbildern untersucht. Es erfolgte eine Gruppeneinteilung in Kinder ohne durchgebrochene obere zweite Molaren (Gruppe 1, n = 14), Jugendliche mit durchgebrochenen oberen zweiten Molaren (Gruppe 2, n = 23) und Erwachsene (Gruppe 3, n = 14). In Gruppe 1 wurden zur Distalisierung Kräfte von 2,4 N, in den Gruppen 2 und 3 von 5 N appliziert. Die Veränderungen wurden anhand der Fernröntgenseitenbilder ausgewertet und hinsichtlich statistisch signifikanter Unterschiede untersucht. Bei allen Patienten konnte eine Klasse-I-Verzahnung erreicht werden. Alle inserierten Miniimplantate verblieben während der gesamten Behandlung stabil. Die Distalisierungsstrecke wurde anhand der Bewegung des Widerstandszentrums der oberen ersten Molaren festgestellt und betrug durchschnittlich 3,6 ± 1,9 mm. Das Ausmaß der Distalisierung variierte befundbezogen zwischen 1,2 und 8,5 mm. Es handelte sich um eine nahezu körperliche Bewegung der Molaren, eine signifikante Kippung konnte nicht beobachtet werden. Über die gesamte Behandlungszeit wurde eine Distalisierungsgeschwindigkeit von 0,6 ± 0,4 mm pro Monat festgestellt. Signifikante Unterschiede zwischen den Gruppen gab es nicht. Mittels Beneslider wurde eine effektive und körperliche Molarendistalisierung in angemessener Behandlungsdauer erreicht. Der höhere Widerstand, den durchgebrochene zweite Molaren bewirken, kann durch eine Steigerung der applizierten Kräfte ausgeglichen werden. Eine signifikante Verringerung der Distalisierungsgeschwindigkeit konnte vermieden werden.
- 1 January 2014
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 84 (1) , 127-133
Mini-implant stability at the initial healing period: A clinical pilot study
Objective: To evaluate the changes of mini-implant stability over the initial healing period in humans. Material and Methods: A sample of 19 consecutively treated patients (mean age 15.5 ± 7.3 years) was examined. In each patient, a mini-implant of a size of 2 × 9 mm was inserted into the anterior palate. Implant stability was assessed using resonance frequency analysis (RFA) immediately after insertion (T0), 2 weeks later (T1), 4 weeks later (T2), and 6 weeks later (T3). Insertion depth (ID) and the maximum insertion torque (IT) were measured. Data were tested for correlations between RFA, ID, and IT. All RFA values were tested for statistically significant differences between the different times. Results: The mean ID was 7.5 ± 0.6 mm, and the mean IT was 16.8 ± 0.6 Ncm. A correlation was found between RFA and ID ( r = .726, P < .0001), whereas no correlations between RFA and IT or between IT and ID were observed. From T0 to T1, the stability (36.1 ± 6.1 implant stability quotient [ISQ]) decreased nonsignificantly by 4.9 ± 6.1 ISQ values ( P > .05). Between T1 and T2, the stability decreased highly significantly ( P < .001) by 7.9 ± 5.9 ISQ values. From T2 on, RFA remained nearly unchanged (−1.7 ± 3.5 ISQ; P > .05). Conclusions: Mini-implant stability is subject to changes during the healing process. During weeks 3 and 4, a significant decrease of the stability was observed. After 4 weeks, the stability did not change significantly.
- 1 January 2014
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 84 (1) , 127-133
Mini-implant stability at the initial healing period: A clinical pilot study
Objective: To evaluate the changes of mini-implant stability over the initial healing period in humans. Material and Methods: A sample of 19 consecutively treated patients (mean age 15.5 ± 7.3 years) was examined. In each patient, a mini-implant of a size of 2 × 9 mm was inserted into the anterior palate. Implant stability was assessed using resonance frequency analysis (RFA) immediately after insertion (T0), 2 weeks later (T1), 4 weeks later (T2), and 6 weeks later (T3). Insertion depth (ID) and the maximum insertion torque (IT) were measured. Data were tested for correlations between RFA, ID, and IT. All RFA values were tested for statistically significant differences between the different times. Results: The mean ID was 7.5 ± 0.6 mm, and the mean IT was 16.8 ± 0.6 Ncm. A correlation was found between RFA and ID ( r = .726, P < .0001), whereas no correlations between RFA and IT or between IT and ID were observed. From T0 to T1, the stability (36.1 ± 6.1 implant stability quotient [ISQ]) decreased nonsignificantly by 4.9 ± 6.1 ISQ values ( P > .05). Between T1 and T2, the stability decreased highly significantly ( P < .001) by 7.9 ± 5.9 ISQ values. From T2 on, RFA remained nearly unchanged (−1.7 ± 3.5 ISQ; P > .05). Conclusions: Mini-implant stability is subject to changes during the healing process. During weeks 3 and 4, a significant decrease of the stability was observed. After 4 weeks, the stability did not change significantly.