Dieter Drescher
Research Subjects
Dieter Drescher has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Benedict Wilmes
Department of Orthodontics, University of Düsseldorf, Düsseldorf, Germany.
26 shared publications - Manuel Nienkemper
A Instructor, Department of Orthodontics, Heinrich-Heine-University, Düsseldorf, Germany
16 shared publications - Björn Ludwig
Department of Orthodontics, University of Homburg, Saar, Germany; Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Private Practice of Orthodontics in Traben-Trarbach, Germany.
11 shared publications - Alexander Pauls
Kieferorthopädische Fachpraxis, Baden-Baden
8 shared publications - Kathrin Becker
Department of Orthodontics and Dentofacial Orthopaedics Charité – Universitätsmedizin Berlin Berlin Germany
5 shared publications - Beryl Schwarz-Herzke
Institute of Anatomy II, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany
3 shared publications
Latest Publications
- Open Access
- 4 March 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 269-278
Is simultaneous placement of orthodontic mini-implants and skeletally anchored appliances advisable?
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.
- 4 March 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 269-278
Open AccessIs simultaneous placement of orthodontic mini-implants and skeletally anchored appliances advisable?
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.
- Open Access
Micro finite element analysis of continuously loaded mini-implants – A micro-CT study in the rat tail model
- Open Access
- 11 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (16) , 9162
Accuracy of Two Variants of 3D-Printed Insertion Guides for Orthodontic Mini-Implants: An Ex Vivo Study in Human Cadavers
Insertion guides are becoming popular for orthodontic mini-implant positioning. The aim of this study was to evaluate and compare the accuracy of two different mini-implant insertion guides, with or without pre-drilling, in a human cadaveric model. Maxillary casts of six fresh frozen specimens were digitized to create insertion guides. Sixty mini-implants were randomly inserted with full-arch or skeletonized guides, either with or without predrilling. Pre- and post-treatment CBCTs were superimposed using rigid registration. Transformation matrices of the planned and real positions were obtained, and distances at the mini-implant neck and apex, as well as the angular deviation, were calculated. The Kruskal–Wallis test was performed, followed by a post hoc test when indicated. Out of 60 inserted mini-implants, 46 could be evaluated. Of these, 10 initially assigned to no pre-drilling required this procedure due to very high bone density. Therefore, 32 implants were inserted with pre-drilling (n = 15 full-arch; n = 17 skeletonized) and 14 without (n = 7 full-arch; n = 7 skeletonized). The lowest mean deviation at the neck was 1.22 ± 0.6 mm, registered in the full-arch/pre-drilling group. The skeletonized/no pre-drilling group presented the lowest mean values at the apex, i.e., 1.72 ± 1.22 mm, as well as the lowest mean angular deviation, i.e., 8.23 ± 4.24°. Significant differences among groups were observed only at the neck, with higher mean deviation in the skeletonized/pre-drilling group than in the full-arch/pre-drilling one (p = 0.014). In conclusion, within the limitations of the study, rather high deviations between planned and real mini-implant positions were found. Further studies are needed on how to improve the accuracy within in vivo settings.
- 11 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (16) , 9162
Open AccessAccuracy of Two Variants of 3D-Printed Insertion Guides for Orthodontic Mini-Implants: An Ex Vivo Study in Human Cadavers
Insertion guides are becoming popular for orthodontic mini-implant positioning. The aim of this study was to evaluate and compare the accuracy of two different mini-implant insertion guides, with or without pre-drilling, in a human cadaveric model. Maxillary casts of six fresh frozen specimens were digitized to create insertion guides. Sixty mini-implants were randomly inserted with full-arch or skeletonized guides, either with or without predrilling. Pre- and post-treatment CBCTs were superimposed using rigid registration. Transformation matrices of the planned and real positions were obtained, and distances at the mini-implant neck and apex, as well as the angular deviation, were calculated. The Kruskal–Wallis test was performed, followed by a post hoc test when indicated. Out of 60 inserted mini-implants, 46 could be evaluated. Of these, 10 initially assigned to no pre-drilling required this procedure due to very high bone density. Therefore, 32 implants were inserted with pre-drilling (n = 15 full-arch; n = 17 skeletonized) and 14 without (n = 7 full-arch; n = 7 skeletonized). The lowest mean deviation at the neck was 1.22 ± 0.6 mm, registered in the full-arch/pre-drilling group. The skeletonized/no pre-drilling group presented the lowest mean values at the apex, i.e., 1.72 ± 1.22 mm, as well as the lowest mean angular deviation, i.e., 8.23 ± 4.24°. Significant differences among groups were observed only at the neck, with higher mean deviation in the skeletonized/pre-drilling group than in the full-arch/pre-drilling one (p = 0.014). In conclusion, within the limitations of the study, rather high deviations between planned and real mini-implant positions were found. Further studies are needed on how to improve the accuracy within in vivo settings.
- Open Access
- 2 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1590
Digital Design of Different Transpalatal Arches Made of Polyether Ether Ketone (PEEK) and Determination of the Force Systems
The aim of this study was to investigate whether the polymer polyether ether ketone (PEEK), which is approved for (dental) medical appliances, is suitable for the production of orthodontic treatment appliances. Different geometries of transpalatal arches (TPAs) were designed by Computer Aided Design (CAD). Out of a number of different designs and dimensions, four devices were selected and manufactured by milling out of PEEK. A finite element analysis (FEA) and a mechanical in vitro testing were performed to analyze the force systems acting on the first upper molars. Up to an activation (transversal compression) of 4 mm per side (total 8 mm), the PEEK TPAs generated forces between 1.3 and 3.1 Newton (N) in the FEA and between 0.7 and 3.2 N in the mechanical testing. The moments in the oro-vestibular direction were measured between 2.1 and 6.6 Nmm in the FEA and between 1.1 and 6.0 Nmm in the mechanical testing, depending on the individual TPA geometry. With the help of the FEA, it was possible to calculate the von Mises stresses and the deformation patterns of the different TPAs. In some areas, local von Mises stresses exceeded 154–165 MPa, which could lead to a permanent deformation of the respective appliances. In the in vitro testing, however, none of the TPAs showed any visible deformation or fractures. With the help of the FEA and the mechanical testing, it could be shown that PEEK might be suitable as a material for the production of orthodontic TPAs.
- 2 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1590
Open AccessDigital Design of Different Transpalatal Arches Made of Polyether Ether Ketone (PEEK) and Determination of the Force Systems
The aim of this study was to investigate whether the polymer polyether ether ketone (PEEK), which is approved for (dental) medical appliances, is suitable for the production of orthodontic treatment appliances. Different geometries of transpalatal arches (TPAs) were designed by Computer Aided Design (CAD). Out of a number of different designs and dimensions, four devices were selected and manufactured by milling out of PEEK. A finite element analysis (FEA) and a mechanical in vitro testing were performed to analyze the force systems acting on the first upper molars. Up to an activation (transversal compression) of 4 mm per side (total 8 mm), the PEEK TPAs generated forces between 1.3 and 3.1 Newton (N) in the FEA and between 0.7 and 3.2 N in the mechanical testing. The moments in the oro-vestibular direction were measured between 2.1 and 6.6 Nmm in the FEA and between 1.1 and 6.0 Nmm in the mechanical testing, depending on the individual TPA geometry. With the help of the FEA, it was possible to calculate the von Mises stresses and the deformation patterns of the different TPAs. In some areas, local von Mises stresses exceeded 154–165 MPa, which could lead to a permanent deformation of the respective appliances. In the in vitro testing, however, none of the TPAs showed any visible deformation or fractures. With the help of the FEA and the mechanical testing, it could be shown that PEEK might be suitable as a material for the production of orthodontic TPAs.
- Open Access
- 24 November 2021
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 49 (2) , 188-197
Micro‐angiogenic patterns around orthodontic implants migrating in bone: A micro‐CT study in the rat tail model
Aim: Recent studies revealed that implants can migrate in bone when subjected to continuous loading. Since this process is suspected to be accompanied by bone remodelling, which requires blood vessel formation, the present work aimed at assessing the micro‐angiogenic patterns around migrating implants.Materials and methods: In 16 rats, two customized implants were placed in a single tail vertebra and connected with contraction springs (forces: 0 N, 0.5 N, 1.0 N, 1.5 N). After 2 or 8 weeks of loading, the animals were scanned by micro‐CT before and after vasculature perfusion with a silicone rubber. Vessels were segmented by subtraction of the two micro‐CT scans. Vessel thickness (V.Th), vessel volume per total volume (VV/TV), and vascular spacing (V.Sp) were assessed in a peri‐implant volume of interest (VOI) around each implant.Results: At 2 weeks of loading, force magnitude was significantly associated with VV/TV and V.Th values (χ2 = 10.942, p < .001 and χ2 = 6.028, p = .010, respectively). No significant differences were observed after 8 weeks of loading.Conclusions: Within the limitations of an animal study, peri‐implant vessel thickness and density were associated with force magnitude in the early loading phase, whereas effects diminished after 8 weeks of loading.
- 24 November 2021
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 49 (2) , 188-197
Open AccessMicro‐angiogenic patterns around orthodontic implants migrating in bone: A micro‐CT study in the rat tail model
Aim: Recent studies revealed that implants can migrate in bone when subjected to continuous loading. Since this process is suspected to be accompanied by bone remodelling, which requires blood vessel formation, the present work aimed at assessing the micro‐angiogenic patterns around migrating implants.Materials and methods: In 16 rats, two customized implants were placed in a single tail vertebra and connected with contraction springs (forces: 0 N, 0.5 N, 1.0 N, 1.5 N). After 2 or 8 weeks of loading, the animals were scanned by micro‐CT before and after vasculature perfusion with a silicone rubber. Vessels were segmented by subtraction of the two micro‐CT scans. Vessel thickness (V.Th), vessel volume per total volume (VV/TV), and vascular spacing (V.Sp) were assessed in a peri‐implant volume of interest (VOI) around each implant.Results: At 2 weeks of loading, force magnitude was significantly associated with VV/TV and V.Th values (χ2 = 10.942, p < .001 and χ2 = 6.028, p = .010, respectively). No significant differences were observed after 8 weeks of loading.Conclusions: Within the limitations of an animal study, peri‐implant vessel thickness and density were associated with force magnitude in the early loading phase, whereas effects diminished after 8 weeks of loading.
- Open Access
- 6 July 2021
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 83 (1) , 59-72
Friction behavior of the wire material Gummetal®
Objectives: Gummetal® (Maruemu Works, Osaka, Japan), a new orthodontic wire material successfully used in clinical applications since 2006, is biocompatible and exhibits exceptionally high elasticity, nonlinear elastic behavior, plasticity and strength. Systematic comparisons of friction behavior are lacking; thus, the friction of Gummetal® in the binding modus was compared to commonly used low friction wires. Materials and methods: In vivo tests were run with Gummetal®, CoCr (cobalt-chromium Elgiloy®, Rocky Mountain Orthodontics, Denver, CO, USA), β‑Ti (β-Titanium TMA®, Ormco, Orange, CA, USA), NiTi (nickel–titanium, NiTi-SE, Dentalline, Birkenfeld, Germany), and stainless steel (SS; Ref. 251-925, 3M Unitek, Monrovia, CA, USA) [dimensions: 0.014 inch (0.35 mm), 0.016 inch (0.40 mm), 0.016 × 0.022 inch (0.40 × 0.56 mm), and 0.019 × 0.025 inch (0.48 × 0.64 mm)—β-Ti not available in the dimension 0.014 inch]. These were combined with Discovery® (Dentaurum, Ispringen, Germany), Micro Sprint® (Forestadent, Pforzheim, Germany), Clarity™ (3M Unitek), and Inspire Ice™ (Ormco) and slots in the dimension 0.022 inch (0.56 mm) and, except for the 0.019 × 0.025 inch wires, in the dimension 0.018 inch (0.46 mm). They were ligated with a 0.010 inch (0.25 mm) steel ligature (Smile Dental, Ratingen, Germany). Brackets were angulated by applying a moment of force of 10 Nmm against the wire, which was pulled through the slot at 0.2 mm/s. Results: In 660 tests using 132 bracket–wire combinations, friction loss for Gummetal® was comparable to and, in a few combinations with Micro Sprint®, significantly lower (p < 0.05) than SS and CoCr. The friction for Gummetal® was significantly lower (p < 0.05) than NiTi, and β‑Ti. In some bracket–wire combinations, lower friction was found with round wires compared to rectangular wires, except for the combination with Inspire Ice™, which was higher but not significant. Slot size did not have a significant effect on friction in most combinations. Conclusion: The low friction associated with Gummetal® wires during arch-guided tooth movement will be a valuable addition to the armamentarium of orthodontists.
- 6 July 2021
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 83 (1) , 59-72
Open AccessFriction behavior of the wire material Gummetal®
Objectives: Gummetal® (Maruemu Works, Osaka, Japan), a new orthodontic wire material successfully used in clinical applications since 2006, is biocompatible and exhibits exceptionally high elasticity, nonlinear elastic behavior, plasticity and strength. Systematic comparisons of friction behavior are lacking; thus, the friction of Gummetal® in the binding modus was compared to commonly used low friction wires. Materials and methods: In vivo tests were run with Gummetal®, CoCr (cobalt-chromium Elgiloy®, Rocky Mountain Orthodontics, Denver, CO, USA), β‑Ti (β-Titanium TMA®, Ormco, Orange, CA, USA), NiTi (nickel–titanium, NiTi-SE, Dentalline, Birkenfeld, Germany), and stainless steel (SS; Ref. 251-925, 3M Unitek, Monrovia, CA, USA) [dimensions: 0.014 inch (0.35 mm), 0.016 inch (0.40 mm), 0.016 × 0.022 inch (0.40 × 0.56 mm), and 0.019 × 0.025 inch (0.48 × 0.64 mm)—β-Ti not available in the dimension 0.014 inch]. These were combined with Discovery® (Dentaurum, Ispringen, Germany), Micro Sprint® (Forestadent, Pforzheim, Germany), Clarity™ (3M Unitek), and Inspire Ice™ (Ormco) and slots in the dimension 0.022 inch (0.56 mm) and, except for the 0.019 × 0.025 inch wires, in the dimension 0.018 inch (0.46 mm). They were ligated with a 0.010 inch (0.25 mm) steel ligature (Smile Dental, Ratingen, Germany). Brackets were angulated by applying a moment of force of 10 Nmm against the wire, which was pulled through the slot at 0.2 mm/s. Results: In 660 tests using 132 bracket–wire combinations, friction loss for Gummetal® was comparable to and, in a few combinations with Micro Sprint®, significantly lower (p < 0.05) than SS and CoCr. The friction for Gummetal® was significantly lower (p < 0.05) than NiTi, and β‑Ti. In some bracket–wire combinations, lower friction was found with round wires compared to rectangular wires, except for the combination with Inspire Ice™, which was higher but not significant. Slot size did not have a significant effect on friction in most combinations. Conclusion: The low friction associated with Gummetal® wires during arch-guided tooth movement will be a valuable addition to the armamentarium of orthodontists.
- Open Access
- 22 October 2018
- Published by Springer Nature in Progress in Orthodontics
- Vol. 19 (1) , 1-8
Early Class III treatment with Hybrid-Hyrax -Facemask in comparison to Hybrid-Hyrax-Mentoplate – skeletal and dental outcomes
Protraction of maxilla is usually the preferred and more commonly used treatment approach for skeletal Class III with a retrognathic maxilla. The aim of this study was the comparison of the skeletal and dental effects of two skeletally borne appliances for maxillary protraction: a) Hybrid-Hyrax in combination with facemask (FM), b) Hybrid-Hyrax in combination with Mentoplate (ME). Thirty four Patients (17 facemask, 17 Mentoplate) were investigated by means of pre- and posttreatment cephalograms. The two groups matched with regard to treatment time, age gender and type of dentoskeletal deformity before treatment. Both groups showed a significant forward movement of A-point (FM GROUP: SNA + 2.23° ± 1.30°— p 0.000*; ME: 2.23° ± 1.43°— p 0.000*). B-Point showed a larger sagittal change in the FM Group (SNB 1.51° ± 1.1°— p 0.000*) compared to the ME group (SNB: − 0.30° ± 0.9°— p 0.070). The FM group showed a significant increase of the ML-NL + 1.86° ± 1.65° (p 0.000*) and NSL-ML + 1.17° ± 1.48 (p 0.006*). Upper Incisor inclination did not change significantly during treatment in both groups as well as the distance of the first upper Molar in relation to A-point. Both treatments achieve comparable rates of maxillary protraction, without dentoalveolar side effects. Skeletal anchorage with symphysial plates in the mandible provides greater vertical control and might be the treatment of choice in high angle patients.
- 22 October 2018
- Published by Springer Nature in Progress in Orthodontics
- Vol. 19 (1) , 1-8
Open AccessEarly Class III treatment with Hybrid-Hyrax -Facemask in comparison to Hybrid-Hyrax-Mentoplate – skeletal and dental outcomes
Protraction of maxilla is usually the preferred and more commonly used treatment approach for skeletal Class III with a retrognathic maxilla. The aim of this study was the comparison of the skeletal and dental effects of two skeletally borne appliances for maxillary protraction: a) Hybrid-Hyrax in combination with facemask (FM), b) Hybrid-Hyrax in combination with Mentoplate (ME). Thirty four Patients (17 facemask, 17 Mentoplate) were investigated by means of pre- and posttreatment cephalograms. The two groups matched with regard to treatment time, age gender and type of dentoskeletal deformity before treatment. Both groups showed a significant forward movement of A-point (FM GROUP: SNA + 2.23° ± 1.30°— p 0.000*; ME: 2.23° ± 1.43°— p 0.000*). B-Point showed a larger sagittal change in the FM Group (SNB 1.51° ± 1.1°— p 0.000*) compared to the ME group (SNB: − 0.30° ± 0.9°— p 0.070). The FM group showed a significant increase of the ML-NL + 1.86° ± 1.65° (p 0.000*) and NSL-ML + 1.17° ± 1.48 (p 0.006*). Upper Incisor inclination did not change significantly during treatment in both groups as well as the distance of the first upper Molar in relation to A-point. Both treatments achieve comparable rates of maxillary protraction, without dentoalveolar side effects. Skeletal anchorage with symphysial plates in the mandible provides greater vertical control and might be the treatment of choice in high angle patients.
- 20 December 2017
- Published by Georg Thieme Verlag KG in Informationen aus Orthodontie & Kieferorthopädie
- Vol. 49 (04) , 234-236
Der Beneslider
Der Beneslider ist eine auf 2 palatinalen Mini-Implantaten (Benefit-System, psm Medical Solutions, Tuttlingen, Deutschland) befestigte Apparatur zur Distalisierung oberer Molaren [1]. Zur Anwendung kommen Mini-Implantate mit einem Innengewinde in den Abmessungen 9×2 mm. Als Insertionsregion bietet sich der anteriore Gaumen median aufgrund von hoher Knochenqualität und ausreichendem Knochenangebot an [2] [3]. Die Distalisierung erfolgt mittels Gleitmechanik auf einem rigiden Stahldraht (1,1 mm) (Beneplate). Nach Insertion der Schrauben sowie der Bänder auf den ersten Molaren wird mittels Abdruckkappen und Transfersystem für die Palatinalschlösser ein Abdruck des Oberkiefers mit Alginat oder Silikon angefertigt. Die in die Abdruckkappen gesteckten Laborimplantate sowie die Übertragungselemente des Transfersystems werden ausgewachst und ein Gipsmodell erstellt ([Abb. 1a–d]).
- 20 December 2017
- Published by Georg Thieme Verlag KG in Informationen aus Orthodontie & Kieferorthopädie
- Vol. 49 (04) , 234-236
Der Beneslider
Der Beneslider ist eine auf 2 palatinalen Mini-Implantaten (Benefit-System, psm Medical Solutions, Tuttlingen, Deutschland) befestigte Apparatur zur Distalisierung oberer Molaren [1]. Zur Anwendung kommen Mini-Implantate mit einem Innengewinde in den Abmessungen 9×2 mm. Als Insertionsregion bietet sich der anteriore Gaumen median aufgrund von hoher Knochenqualität und ausreichendem Knochenangebot an [2] [3]. Die Distalisierung erfolgt mittels Gleitmechanik auf einem rigiden Stahldraht (1,1 mm) (Beneplate). Nach Insertion der Schrauben sowie der Bänder auf den ersten Molaren wird mittels Abdruckkappen und Transfersystem für die Palatinalschlösser ein Abdruck des Oberkiefers mit Alginat oder Silikon angefertigt. Die in die Abdruckkappen gesteckten Laborimplantate sowie die Übertragungselemente des Transfersystems werden ausgewachst und ein Gipsmodell erstellt ([Abb. 1a–d]).
- 1 July 2016
- Vol. 50 (7) , 420-6
Uprighting Mesially Impacted Lower Third Molars with Skeletal Anchorage.
- 1 July 2016
- Vol. 50 (7) , 420-6
Uprighting Mesially Impacted Lower Third Molars with Skeletal Anchorage.
- Open Access
- 1 January 2016
- Published by Walter de Gruyter GmbH in Australasian Orthodontic Journal
- Vol. 32 (1) , 88-96
The efficacy of Hybrid Hyrax-Mentoplate combination in early Class III treatment: a novel approach and pilot study
Introduction: The aim of the present study was to assess the skeletal, dental and soft tissue effects of a specific treatment protocol in consecutively treated patients who presented with a Class III malocclusion. Treatment involved the use of a Hybrid Hyrax (HH) in the maxilla, a Mentoplate in the mandible and the application of continuous intra-oral Class III elastics. Method: The treated group was comprised of seven males and seven females (mean pretreatment age 10.4 ± 1.7 yr, range 7.8 – 12.9 yr). Treatment changes were analysed on lateral cephalograms taken 6–12 months prior to commencing treatment (T1) and at the finish of the orthopaedic phase (T2). Where a normality assumption was met, a parametric paired-sample t -test was used to assess the change differences at T1 and T2. For non-normal data, a non-parametric Wilcoxon sign rank test for related samples was used to assess T1 and T2 differences. The level of statistical significance was set at p < 0.05 (2-tailed). Results: The average sagittal changes showed an improved SNA angle of 2.1 ± 2° ( p = 0.002), an ANB angle of 1.9 ± 1.8° ( p = 0.002), a Wits improvement of 3.4 ± 2.7 mm ( p < 0.001) and an overjet reduction of 2.0 ± 2.2 mm ( p = 0.005). There were no statistically significant correlations found between the age at T1, age at treatment start and age at T2 and the changes identified in the cephalometric variables (T2-T1). Conclusion: The HH-Mentoplate Class III treatment protocol induced a mean Wits improvement of 3.4 mm in the maxillary and mandibular sagittal base relationship at the functional occlusal level. This was primarily achieved by sagittal maxillary skeletal protraction with negligible effects on the mandible, facial vertical dimension and the incisor angulations. A controlled clinical study with larger sample sizes and longer follow-up times is needed.
- 1 January 2016
- Published by Walter de Gruyter GmbH in Australasian Orthodontic Journal
- Vol. 32 (1) , 88-96
Open AccessThe efficacy of Hybrid Hyrax-Mentoplate combination in early Class III treatment: a novel approach and pilot study
Introduction: The aim of the present study was to assess the skeletal, dental and soft tissue effects of a specific treatment protocol in consecutively treated patients who presented with a Class III malocclusion. Treatment involved the use of a Hybrid Hyrax (HH) in the maxilla, a Mentoplate in the mandible and the application of continuous intra-oral Class III elastics. Method: The treated group was comprised of seven males and seven females (mean pretreatment age 10.4 ± 1.7 yr, range 7.8 – 12.9 yr). Treatment changes were analysed on lateral cephalograms taken 6–12 months prior to commencing treatment (T1) and at the finish of the orthopaedic phase (T2). Where a normality assumption was met, a parametric paired-sample t -test was used to assess the change differences at T1 and T2. For non-normal data, a non-parametric Wilcoxon sign rank test for related samples was used to assess T1 and T2 differences. The level of statistical significance was set at p < 0.05 (2-tailed). Results: The average sagittal changes showed an improved SNA angle of 2.1 ± 2° ( p = 0.002), an ANB angle of 1.9 ± 1.8° ( p = 0.002), a Wits improvement of 3.4 ± 2.7 mm ( p < 0.001) and an overjet reduction of 2.0 ± 2.2 mm ( p = 0.005). There were no statistically significant correlations found between the age at T1, age at treatment start and age at T2 and the changes identified in the cephalometric variables (T2-T1). Conclusion: The HH-Mentoplate Class III treatment protocol induced a mean Wits improvement of 3.4 mm in the maxillary and mandibular sagittal base relationship at the functional occlusal level. This was primarily achieved by sagittal maxillary skeletal protraction with negligible effects on the mandible, facial vertical dimension and the incisor angulations. A controlled clinical study with larger sample sizes and longer follow-up times is needed.