Thomas Schrom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thomas Schrom has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Hansjoerg Scherer
Physikalisch-Technische Bundesanstalt 7 , 38116 Braunschweig
5 shared publications H. Scherer
Universitätsmedizin Berlin — Charité Campus Mitte
4 shared publicationsB Mazurek
3 shared publicationsA Debelius
2 shared publicationsA. Berghaus
Klinik und Poliklinik für Hals-, Nasen-, Ohrenkrankheiten der Universität München
2 shared publicationsA. Habermann
Klinik für Augenheilkunde, Martin-Luther-Universität Halle-Wittenberg
2 shared publications
Latest Publications
- 31 August 2013
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 92 (09) , 589-593
Peritonsillarabszess - Analyse zu Rauchverhalten, präoperativer Gerinnungsdiagnostik und Therapie
Der Peritonsillarabszess (PTA) ist ein häufiges Erkrankungsbild der Hals-Nasen-Ohrenheilkunde. Die genaue Pathogenese, fördernde Faktoren und optimale Therapie sind Gegenstand zahlreicher Untersuchungen. Im Rahmen einer retrospektiven Analyse sollte geklärt werden, welchen Stellenwert das Rauchverhalten, die präoperative Gerinnungsdiagnostik und die angewandte Therapie beim PTA haben. Von 460 Patienten mit einem PTA wurden die Daten aus dem Behandlungszeitraum vom 01.01.2000 bis zum 31.12.2009 retrospektiv analysiert. Die höchste Inzidenz beim PTA zeigte sich bei jungen Männern, die Prävalenz des Nikotinkonsums war im Vergleich zur Gesamtbevölkerung deutlich erhöht. Die Therapie erfolgte hauptsächlich mittels Abszesstonsillektomie. Auch bei präoperativ pathologischen Gerinnungsparametern zeigte sich kein erhöhtes Nachblutungsrisiko. Der Anteil von Rauchern unter Patienten mit PTA ist im Vergleich zur altersentsprechenden Normalbevölkerung erhöht. Eine routinemäßige präoperative Analyse der Blutgerinnung vor operativer Therapie bei PTA hat nur einen geringen prognostischen Nutzen bezüglich der Vorhersagekraft des Nachblutungsrisikos. Die operative Therapie mittels Abszesstonsillektomie ist ein sicheres Verfahren und hat sich im klinischen Alltag bewährt. Peritonsillar abscess (PTA) is a common problem in otorhinolaryngology. The pathogenesis, supporting factors and optimal therapy are matter of numerous investigations. We studied retrospectively smoking habits, preoperative coagulation screening and the applied therapy of PTA. Data from 460 patients who underwent treatment for PTA between 2000 and 2009 at Dessau Medical Center were retrospectively analysed. The highest incidence of PTA was found in young men, the prevalence of nicotine consumption was clearly increased in relation to the general population. The therapy of first choice was abscess tonsillectomy. Even with preoperative pathological coagulation-parameters no increased risk of secondary bleeding was shown. The part of smokers of patients with PTA is increased in comparison to the correspondent population of same age. A routine preoperative coagulation screening has a low benefit relating to the prediction of the risk of secondary bleeding. Abscess tonsillectomy is a safe method and has proved itself in clinical daily routine.
- 31 August 2013
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 92 (09) , 589-593
Peritonsillarabszess - Analyse zu Rauchverhalten, präoperativer Gerinnungsdiagnostik und Therapie
Der Peritonsillarabszess (PTA) ist ein häufiges Erkrankungsbild der Hals-Nasen-Ohrenheilkunde. Die genaue Pathogenese, fördernde Faktoren und optimale Therapie sind Gegenstand zahlreicher Untersuchungen. Im Rahmen einer retrospektiven Analyse sollte geklärt werden, welchen Stellenwert das Rauchverhalten, die präoperative Gerinnungsdiagnostik und die angewandte Therapie beim PTA haben. Von 460 Patienten mit einem PTA wurden die Daten aus dem Behandlungszeitraum vom 01.01.2000 bis zum 31.12.2009 retrospektiv analysiert. Die höchste Inzidenz beim PTA zeigte sich bei jungen Männern, die Prävalenz des Nikotinkonsums war im Vergleich zur Gesamtbevölkerung deutlich erhöht. Die Therapie erfolgte hauptsächlich mittels Abszesstonsillektomie. Auch bei präoperativ pathologischen Gerinnungsparametern zeigte sich kein erhöhtes Nachblutungsrisiko. Der Anteil von Rauchern unter Patienten mit PTA ist im Vergleich zur altersentsprechenden Normalbevölkerung erhöht. Eine routinemäßige präoperative Analyse der Blutgerinnung vor operativer Therapie bei PTA hat nur einen geringen prognostischen Nutzen bezüglich der Vorhersagekraft des Nachblutungsrisikos. Die operative Therapie mittels Abszesstonsillektomie ist ein sicheres Verfahren und hat sich im klinischen Alltag bewährt. Peritonsillar abscess (PTA) is a common problem in otorhinolaryngology. The pathogenesis, supporting factors and optimal therapy are matter of numerous investigations. We studied retrospectively smoking habits, preoperative coagulation screening and the applied therapy of PTA. Data from 460 patients who underwent treatment for PTA between 2000 and 2009 at Dessau Medical Center were retrospectively analysed. The highest incidence of PTA was found in young men, the prevalence of nicotine consumption was clearly increased in relation to the general population. The therapy of first choice was abscess tonsillectomy. Even with preoperative pathological coagulation-parameters no increased risk of secondary bleeding was shown. The part of smokers of patients with PTA is increased in comparison to the correspondent population of same age. A routine preoperative coagulation screening has a low benefit relating to the prediction of the risk of secondary bleeding. Abscess tonsillectomy is a safe method and has proved itself in clinical daily routine.
- 8 December 2008
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 88 (04) , 236-240
Verhalten von Titan-Mittelohrimplantaten bei 1,5 und 3 Tesla Feldstärke in der Magnetresonanztomographie
Hintergrund: Untersuchungen über die MRT-Tauglichkeit von Mittelohrimplantaten aus Titan bei 1,5 und 3 Tesla Feldstärke (TF) MRT-Systemen. Methode: Die Erwärmung von 17 verschiedenen Mittelohr-Implantaten (Mittelohr: MO) aus Titan unter dem Einfluss von starken Hochfrequenzimpulsen wurde in vitro untersucht. Die Beurteilung der Anziehungskräfte der Implantate erfolgte schwimmend auf Moosgummi (MG) im Wasserbad. Ergebnisse: Eine Erwärmung der Implantate wurde bei keiner der verwendeten Sequenzen sowohl bei 3 als auch bei 1,5 TF beobachtet. Alle 17 Implantate schwammen mit geringer Geschwindigkeit (0,0004–0,0014 m/s) auf das Magnetfeld zu. Bei 1,5 TF kam es bei den getesteten MO-Implantaten schwimmend zu einer Geschwindigkeit von max. 0,0002 m/s und 0,0005 m/s bei den Paukenröhrchen. Schlussfolgerung: Es fand sich keine Erwärmung bei allen untersuchten MO-Implantaten sowohl bei 1,5 und 3 TF. Die durch das statische Magnetfeld wirkenden Anziehungskräfte sind bei 1,5 und 3 TF insgesamt gering, sodass bei sachgerechter intraoperativer Verankerung keine Dislokation zu erwarten ist. Die Indikation zur Untersuchung sollte bei 3 TF aufgrund der anatomisch sensiblen Region streng geprüft werden. Behaviour of Titanium Middle Ear Implants at 1.5 and 3 Tesla Field Strength in Magnetic Resonance Imaging Background: Investigations into the MRI compatibility of middle ear implants made from titanium alloys with 1.5 and 3.0 tesla MRI systems which are frequently used for imaging diagnostics. Method: 17 different middle ear (ME) implants (ossicular replacement prosthesis (ORP) and ventilation tubes) made from titanium were tested in vitro. Potential warming was determined via an MRI-compatible fibre optic temperature sensor under the influence of sequences with high-level high frequency impulses. An assessment of the attractive force of the implants was carried out placed on a Petri dish under vibration and floating on rubber-sponge (RS) in a water bath. Results: No significant warming of the implants was observed with any of the used sequences at either 3 or 1.5 Tesla field strength (TF). With 3 TF, all 17 implants changed their position on the surface of the water and moved at a slow speed (0.0004–0.0014 m/s) towards the magnetic field. With 1.5 TF, the tested ME implants moved at a maximum speed of 0.0002 m/s and in the case of the ventilation tubes at 0.0005 m/s. Conclusion: No warming occurred in any of the tested middle ear implants at either 1.5 or 3 TF. The attractive forces exerted through the static magnetic field were overall low at 1.5 and 3 TF, indicating that no dislocation is to be expected if intraoperative anchoring is correctly conducted. Nevertheless, the indication for examination at 3 TF should be carefully considered due to the anatomically sensitive region.
- 8 December 2008
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 88 (04) , 236-240
Verhalten von Titan-Mittelohrimplantaten bei 1,5 und 3 Tesla Feldstärke in der Magnetresonanztomographie
Hintergrund: Untersuchungen über die MRT-Tauglichkeit von Mittelohrimplantaten aus Titan bei 1,5 und 3 Tesla Feldstärke (TF) MRT-Systemen. Methode: Die Erwärmung von 17 verschiedenen Mittelohr-Implantaten (Mittelohr: MO) aus Titan unter dem Einfluss von starken Hochfrequenzimpulsen wurde in vitro untersucht. Die Beurteilung der Anziehungskräfte der Implantate erfolgte schwimmend auf Moosgummi (MG) im Wasserbad. Ergebnisse: Eine Erwärmung der Implantate wurde bei keiner der verwendeten Sequenzen sowohl bei 3 als auch bei 1,5 TF beobachtet. Alle 17 Implantate schwammen mit geringer Geschwindigkeit (0,0004–0,0014 m/s) auf das Magnetfeld zu. Bei 1,5 TF kam es bei den getesteten MO-Implantaten schwimmend zu einer Geschwindigkeit von max. 0,0002 m/s und 0,0005 m/s bei den Paukenröhrchen. Schlussfolgerung: Es fand sich keine Erwärmung bei allen untersuchten MO-Implantaten sowohl bei 1,5 und 3 TF. Die durch das statische Magnetfeld wirkenden Anziehungskräfte sind bei 1,5 und 3 TF insgesamt gering, sodass bei sachgerechter intraoperativer Verankerung keine Dislokation zu erwarten ist. Die Indikation zur Untersuchung sollte bei 3 TF aufgrund der anatomisch sensiblen Region streng geprüft werden. Behaviour of Titanium Middle Ear Implants at 1.5 and 3 Tesla Field Strength in Magnetic Resonance Imaging Background: Investigations into the MRI compatibility of middle ear implants made from titanium alloys with 1.5 and 3.0 tesla MRI systems which are frequently used for imaging diagnostics. Method: 17 different middle ear (ME) implants (ossicular replacement prosthesis (ORP) and ventilation tubes) made from titanium were tested in vitro. Potential warming was determined via an MRI-compatible fibre optic temperature sensor under the influence of sequences with high-level high frequency impulses. An assessment of the attractive force of the implants was carried out placed on a Petri dish under vibration and floating on rubber-sponge (RS) in a water bath. Results: No significant warming of the implants was observed with any of the used sequences at either 3 or 1.5 Tesla field strength (TF). With 3 TF, all 17 implants changed their position on the surface of the water and moved at a slow speed (0.0004–0.0014 m/s) towards the magnetic field. With 1.5 TF, the tested ME implants moved at a maximum speed of 0.0002 m/s and in the case of the ventilation tubes at 0.0005 m/s. Conclusion: No warming occurred in any of the tested middle ear implants at either 1.5 or 3 TF. The attractive forces exerted through the static magnetic field were overall low at 1.5 and 3 TF, indicating that no dislocation is to be expected if intraoperative anchoring is correctly conducted. Nevertheless, the indication for examination at 3 TF should be carefully considered due to the anatomically sensitive region.
- Open Access
- 21 July 2008
- Published by Springer Nature in Head & Face Medicine
- Vol. 4 (1) , 12
Temporary ectropion therapy by adhesive taping: a case study
Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip.
- 21 July 2008
- Published by Springer Nature in Head & Face Medicine
- Vol. 4 (1) , 12
Open AccessTemporary ectropion therapy by adhesive taping: a case study
Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip.
- 1 November 2006
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 22 (6) , 480-482
Effect of 7.0 Tesla MRI on Upper Eyelid Implants
To ensure the MRI compatibility of various eyelid implants in high-field MRI, 3 eyelid weights made of pure gold (99.99%), pure platinum (99.95%), and a platinum (97%)/iridium (3%) alloy were examined in vitro. Temperature changes, position changes, and imaging artifacts of the different implants were determined in a small-bore 7.0 Tesla MRI system. The 7.0 Tesla MRI system demonstrated that none of the eyelid implants carried a risk of heating or dislocation; therefore, these implants are MRI compatible up to a magnetic field strength of 7.0 Tesla.
- 1 November 2006
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 22 (6) , 480-482
Effect of 7.0 Tesla MRI on Upper Eyelid Implants
To ensure the MRI compatibility of various eyelid implants in high-field MRI, 3 eyelid weights made of pure gold (99.99%), pure platinum (99.95%), and a platinum (97%)/iridium (3%) alloy were examined in vitro. Temperature changes, position changes, and imaging artifacts of the different implants were determined in a small-bore 7.0 Tesla MRI system. The 7.0 Tesla MRI system demonstrated that none of the eyelid implants carried a risk of heating or dislocation; therefore, these implants are MRI compatible up to a magnetic field strength of 7.0 Tesla.
- 1 August 2006
- Published by Springer Nature in HNO
- Vol. 54 (8) , 591-598
Histopathologie nach Implantation von Lidgewichten
Zur Therapie des Lagophthalmus bei Fazialisparese kommen unterschiedliche Implantate zum Einsatz. Die Implantation von Lidgewichten (Lidloading) aus Gold oder Platin hat sich zunehmend durchgesetzt. Systematische Untersuchungen histologischer Veränderungen der Implantatkapsel im Rahmen einer Explantation der Lidgewichte sind bisher nicht erfolgt.
- 1 August 2006
- Published by Springer Nature in HNO
- Vol. 54 (8) , 591-598
Histopathologie nach Implantation von Lidgewichten
Zur Therapie des Lagophthalmus bei Fazialisparese kommen unterschiedliche Implantate zum Einsatz. Die Implantation von Lidgewichten (Lidloading) aus Gold oder Platin hat sich zunehmend durchgesetzt. Systematische Untersuchungen histologischer Veränderungen der Implantatkapsel im Rahmen einer Explantation der Lidgewichte sind bisher nicht erfolgt.
- 26 April 2006
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 223 (4) , 285-288
Sonographie des Oberlids zur Beurteilung der Tarsuskrümmung bei Fazialisparese
Hintergrund: Zur Therapie des paralytischen Lagophthalmus kommen chirurgische Verfahren zum Einsatz. Dazu ist die genaue Kenntnis der Lidanatomie erforderlich. Während umfangreiche Untersuchungen der anatomischen Abmessungen der Lider bei Augengesunden vorliegen, existieren keinerlei Daten über Änderungen der funktionellen Anatomie des Oberlids beim paralytischen Lagophthalmus. Ziel der Studie war, blickrichtungsabhängige Änderungen des Oberlidtarsus sonographisch zu untersuchen und die Frage zu beantworten, ob sich der Krümmungsradius des Tarsus aufgrund einer Fazialisparese mit resultierendem Lagophthalmus ändert. Material und Methoden: Es wurden zwei Gruppen gebildet. Die erste Gruppe bestand aus 50 augengesunden Probanden, die zweite Gruppe bildeten 47 Patienten mit einem paralytischen Lagophthalmus. In beiden Gruppen wurde der Radius des Oberlidtarsus bei Blick geradeaus und in Abduktionsstellung sonographisch mit einem 7,5-MHz-Scanner im Non-Kontakt-Verfahren bestimmt und statistisch miteinander verglichen. Ergebnisse: Beim Blick geradeaus und beim Blick zur Seite kam es in beiden Gruppen zu einem statistisch hochsignifikanten Unterschied des Krümmungsradius des Tarsus. Während beim Blick zur Seite zwischen beiden Gruppen kein statistisch signifikanter Unterschied besteht, zeigte sich beim Blick geradeaus ein statistisch signifikanter Unterschied. Der Vergleich der augengesunden Probanden mit dem gesunden Auge der Patienten ergab auch statistisch signifikante Unterschiede. Schlussfolgerungen: Die Änderung des Radius der Tarsuskrümmung beim Blick geradeaus lässt sich durch den Tonusverlust des paralytischen Musculus orbicularis oculi erklären. Das bedeutet, dass es bei der Fazialisparese neben dem resultierenden Lagophthalmus zu einer Änderung der funktionellen Anatomie des Oberlids kommt, was bei chirurgischen Korrekturen berücksichtigt werden muss. Zusätzlich besitzt der altersphysiologische Tonusverlust des Oberlidtarsus einen gewissen Einfluss. Background: Treatment of paralytic lagophthalmos involves surgical repair, requiring exact knowledge of eyelid anatomy. While there are extensive studies on anatomical eyelid measurements in healthy eyes, no data exist on the changes in the functional anatomy of the upper eyelid in paralytic lagophthalmos. The aim of this study, was to examine by ultrasound the upper lid tarsus during changes in the patient’s line of vision, and to answer the question of whether there are changes in the curvature radius of the tarsus, caused by facial paralysis with resultant lagophthalmos. Material and methods: Two groups were formed. The first group consisted of 50 subjects with healthy eyes, and the second contained 47 patients with paralytic lagophthalmos. The upper lid tarsal radius, when looking straight ahead and in the abducted position, was determined by ultrasound with a 7.5 MHz scanner in the non-contact mode, and then compared statistically. Results: Both groups showed a highly significant difference in the tarsus curvature, when looking straight ahead and in the abduction position. While there was no significant difference between both groups in the abduction position, they differed significantly when looking straight ahead. Also, a significant difference was noted, between the eyes of healthy subjects and the healthy eye in patients with facial palsy. Conclusion: The changes in curvature of the tarsal plate, when looking straight ahead, can be explained by the loss of tone in the paralyzed Orbicularis Occuli muscle. This means, that in addition to the lagophthalmos resulting from facial paralysis, changes occur in the functional anatomy of the upper eyelid, which must be considered during surgical correction. Additionally, the physiological loss of tone of the upper eyelid tarsal plate, which comes with age, has a certain influence.
- 26 April 2006
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 223 (4) , 285-288
Sonographie des Oberlids zur Beurteilung der Tarsuskrümmung bei Fazialisparese
Hintergrund: Zur Therapie des paralytischen Lagophthalmus kommen chirurgische Verfahren zum Einsatz. Dazu ist die genaue Kenntnis der Lidanatomie erforderlich. Während umfangreiche Untersuchungen der anatomischen Abmessungen der Lider bei Augengesunden vorliegen, existieren keinerlei Daten über Änderungen der funktionellen Anatomie des Oberlids beim paralytischen Lagophthalmus. Ziel der Studie war, blickrichtungsabhängige Änderungen des Oberlidtarsus sonographisch zu untersuchen und die Frage zu beantworten, ob sich der Krümmungsradius des Tarsus aufgrund einer Fazialisparese mit resultierendem Lagophthalmus ändert. Material und Methoden: Es wurden zwei Gruppen gebildet. Die erste Gruppe bestand aus 50 augengesunden Probanden, die zweite Gruppe bildeten 47 Patienten mit einem paralytischen Lagophthalmus. In beiden Gruppen wurde der Radius des Oberlidtarsus bei Blick geradeaus und in Abduktionsstellung sonographisch mit einem 7,5-MHz-Scanner im Non-Kontakt-Verfahren bestimmt und statistisch miteinander verglichen. Ergebnisse: Beim Blick geradeaus und beim Blick zur Seite kam es in beiden Gruppen zu einem statistisch hochsignifikanten Unterschied des Krümmungsradius des Tarsus. Während beim Blick zur Seite zwischen beiden Gruppen kein statistisch signifikanter Unterschied besteht, zeigte sich beim Blick geradeaus ein statistisch signifikanter Unterschied. Der Vergleich der augengesunden Probanden mit dem gesunden Auge der Patienten ergab auch statistisch signifikante Unterschiede. Schlussfolgerungen: Die Änderung des Radius der Tarsuskrümmung beim Blick geradeaus lässt sich durch den Tonusverlust des paralytischen Musculus orbicularis oculi erklären. Das bedeutet, dass es bei der Fazialisparese neben dem resultierenden Lagophthalmus zu einer Änderung der funktionellen Anatomie des Oberlids kommt, was bei chirurgischen Korrekturen berücksichtigt werden muss. Zusätzlich besitzt der altersphysiologische Tonusverlust des Oberlidtarsus einen gewissen Einfluss. Background: Treatment of paralytic lagophthalmos involves surgical repair, requiring exact knowledge of eyelid anatomy. While there are extensive studies on anatomical eyelid measurements in healthy eyes, no data exist on the changes in the functional anatomy of the upper eyelid in paralytic lagophthalmos. The aim of this study, was to examine by ultrasound the upper lid tarsus during changes in the patient’s line of vision, and to answer the question of whether there are changes in the curvature radius of the tarsus, caused by facial paralysis with resultant lagophthalmos. Material and methods: Two groups were formed. The first group consisted of 50 subjects with healthy eyes, and the second contained 47 patients with paralytic lagophthalmos. The upper lid tarsal radius, when looking straight ahead and in the abducted position, was determined by ultrasound with a 7.5 MHz scanner in the non-contact mode, and then compared statistically. Results: Both groups showed a highly significant difference in the tarsus curvature, when looking straight ahead and in the abduction position. While there was no significant difference between both groups in the abduction position, they differed significantly when looking straight ahead. Also, a significant difference was noted, between the eyes of healthy subjects and the healthy eye in patients with facial palsy. Conclusion: The changes in curvature of the tarsal plate, when looking straight ahead, can be explained by the loss of tone in the paralyzed Orbicularis Occuli muscle. This means, that in addition to the lagophthalmos resulting from facial paralysis, changes occur in the functional anatomy of the upper eyelid, which must be considered during surgical correction. Additionally, the physiological loss of tone of the upper eyelid tarsal plate, which comes with age, has a certain influence.
- 1 March 2006
- Published by Springer Nature in HNO
- Vol. 54 (3) , 202-206
Innenohrschwerhörigkeit beim LEOPARD-Syndrom
- 1 March 2006
- Published by Springer Nature in HNO
- Vol. 54 (3) , 202-206
Innenohrschwerhörigkeit beim LEOPARD-Syndrom
- 1 December 2005
- Published by Springer Nature in Der Ophthalmologe
- Vol. 102 (12) , 1186-1192
Implantation von Lidgewichten zur Therapie des Lagophthalmus
- 1 December 2005
- Published by Springer Nature in Der Ophthalmologe
- Vol. 102 (12) , 1186-1192
Implantation von Lidgewichten zur Therapie des Lagophthalmus
- 1 August 2005
- Published by Springer Nature in HNO
- Vol. 53 (8) , 741-746
Einfluss der Magnetresonanztomographie auf Oberlidimplantate
Zur Therapie des paralytischen Lagophthalmus bei Fazialisparese werden Lidgewichte aus reinem Gold (99,99%), reinem Platin (99,95%) oder einer Platin(97%)-Iridium(3%)-Legierung implantiert. Untersuchungen über die MRT-Tauglichkeit der Lidimplantate bei 1,5- und 3,0-T-MRT-Systemen, die oft zur Diagnostik bei Kopf-Hals-Tumoren eingesetzt werden, stehen bisher noch aus.
- 1 August 2005
- Published by Springer Nature in HNO
- Vol. 53 (8) , 741-746
Einfluss der Magnetresonanztomographie auf Oberlidimplantate
Zur Therapie des paralytischen Lagophthalmus bei Fazialisparese werden Lidgewichte aus reinem Gold (99,99%), reinem Platin (99,95%) oder einer Platin(97%)-Iridium(3%)-Legierung implantiert. Untersuchungen über die MRT-Tauglichkeit der Lidimplantate bei 1,5- und 3,0-T-MRT-Systemen, die oft zur Diagnostik bei Kopf-Hals-Tumoren eingesetzt werden, stehen bisher noch aus.
- 1 June 2005
- Published by Springer Nature in HNO
- Vol. 53 (6) , 554-556
Endolaryngeale Schwellung mit Dyspnoe
- 1 June 2005
- Published by Springer Nature in HNO
- Vol. 53 (6) , 554-556
Endolaryngeale Schwellung mit Dyspnoe