    The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty

    by James P. Lever, Rad Zdero, Markku T. Nousiainen, James P. Waddell, Emil H. Schemitsch

    Background A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty. Methods Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values. Results All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05). Conclusions Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty.

  • Open Access

    The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty

    by James P. Lever, Rad Zdero, Markku T. Nousiainen, James P. Waddell, Emil H. Schemitsch

    Background A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty. Methods Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values. Results All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05). Conclusions Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty.

    • 1 July 2014
      • Vol. 35, 27-38

    Biomechanical fatigue analysis of an advanced new carbon fiber/flax/epoxy plate for bone fracture repair using conventional fatigue tests and thermography.

    by Zahra S Bagheri, Ihab El Sawi, Habiba Bougherara, Radovan Zdero

    The current study is part of an ongoing research program to develop an advanced new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite with a “sandwich structure” as a substitute for metallic materials for orthopedic long bone fracture plate applications. The purpose of this study was to assess the fatigue properties of this composite, since cyclic loading is one of the main types of loads carried by a femur fracture plate during normal daily activities. Conventional fatigue testing, thermographic analysis, and scanning electron microscopy (SEM) were used to analyze the damage progress that occurred during fatigue loading. Fatigue strength obtained using thermography analysis (51% of ultimate tensile strength) was confirmed using the conventional fatigue test (50–55% of ultimate tensile strength). The dynamic modulus (E⁎) was found to stay almost constant at 47 GPa versus the number of cycles, which can be related to the contribution of both flax/epoxy and CF/epoxy laminae to the stiffness of the composite. SEM images showed solid bonding at the CF/epoxy and flax/epoxy laminae, with a crack density of only 0.48% for the plate loaded for 2 million cycles. The current composite plate showed much higher fatigue strength than the main loads experienced by a typical patient during cyclic activities; thus, it may be a potential candidate for bone fracture plate applications. Moreover, the fatigue strength from thermographic analysis was the same as that obtained by the conventional fatigue tests, thus demonstrating its potential use as an alternate tool to rapidly evaluate fatigue strength of composite biomaterials.


  • The Biomechanical Effect of Proximal Tumor Defect Location on Femur Pathological Fractures

    by Ramanan Mbbs Sivasundaram, Suraj Masc Shah, Shahryar Ahmadi, Jay S. Md Wunder, Emil H. Md Schemitsch, Peter C. Msc Ferguson, Rad Zdero

    Objectives: The femur is the most common long bone affected by cancerous metastasis. Femoral tumor defects are known to induce pain and functional impairment in patients. Although prior studies exist evaluating the clinical and biomechanical effect of tumor defect size, no biomechanical studies have experimentally examined the risk of pathological fracture with respect to the anterior, posterior, medial, and lateral surfaces on which a proximal tumor defect is located on the femur. Methods: Circular tumor-like defects of 40-mm diameter were created proximally in the subtrochanteric region on the Anterior (n = 5), Posterior (n = 5), Medial (n = 5), and Lateral (n = 5) sides of 20 synthetic femurs. Intact femurs served as a control group (n = 4). Femurs were tested for lateral, “offset” torsional, and axial stiffness, as well as axial strength. Results: Lateral stiffnesses (range, 121–162 N/mm) yielded no differences between groups (P = 0.069). “Offset” torsional stiffnesses (range, 135–188 N/mm) demonstrated that the Medial group was less stiff than the Intact, Anterior, and Lateral groups (P ≤ 0.012). Axial stiffnesses (range, 1057–1993 N/mm) showed that the Medial group was less stiff than the Intact group (P = 0.006). Axial strengths (range, 3250–6590 N) for the Medial group were lower than Anterior (P = 0.001) and Posterior (P = 0.001) specimens, whereas the Lateral group had a lower strength than Anterior specimens (P = 0.019). No other statistical differences were noted. Axial failure of Medial and Lateral specimens involved the tumor-like defect in 100% of cases, whereas 100% of Intact femurs and 80% of Anterior and Posterior femur groups failed only through the neck. Conclusions: In 2 of 3 test modes, the Medial tumor-like defect group resulted in statistically lower stiffness values compared with Intact femurs and had lower strength than Anterior and Posterior groups in axial failure.


  • Biomechanical Measurements of Surgical Drilling Force and Torque in Human Versus Artificial Femurs

    by Troy MacAvelia, Meisam Salahi, Michael Olsen, Meghan Crookshank, Emil H. Schemitsch, Ahmad Ghasempoor, Farrokh Janabi-Sharifi, Rad Zdero

    Few experimental studies have examined surgical drilling in human bone, and no studies have inquired into this aspect for a popular commercially-available artificial bone used in biomechanical studies. Sixteen fresh-frozen human femurs and five artificial femurs were obtained. Cortical specimens were mounted into a clamping system equipped with a thrust force and torque transducer. Using a CNC machine, unicortical holes were drilled in each specimen at 1000 rpm, 1250 rpm, and 1500 rpm with a 3.2 mm diameter surgical drill bit. Feed rate was 120 mm/min. Statistical significance was set at p < 0.05. Force at increasing spindle speed (1000 rpm, 1250 rpm, and 1500 rpm), respectively, showed a range for human femurs (198.4 ± 14.2 N, 180.6 ± 14.0 N, and 176.3 ± 11.2 N) and artificial femurs (87.2 ± 19.3 N, 82.2 ± 11.2 N, and 75.7 ± 8.8 N). For human femurs, force at 1000 rpm was greater than at other speeds (p ≤ 0.018). For artificial femurs, there was no speed effect on force (p ≥ 0.991). Torque at increasing spindle speed (1000 rpm, 1250 rpm, and 1500 rpm), respectively, showed a range for human femurs (186.3 ± 16.9 N·mm, 157.8 ± 16.1 N·mm, and 140.2 ± 16.4 N·mm) and artificial femurs (67.2 ± 8.4 N·mm, 61.0 ± 2.9 N·mm, and 53.3 ± 2.9 N·mm). For human femurs, torque at 1000 rpm was greater than at other speeds (p < 0.001). For artificial femurs, there was no difference in torque for 1000 rpm versus higher speeds (p ≥ 0.228), and there was only a borderline difference between the higher speeds (p = 0.046). Concerning human versus artificial femurs, their behavior was different at every speed (force, p ≤ 0.001; torque, p < 0.001). For human specimens at 1500 rpm, force and torque were linearly correlated with standardized bone mineral density (sBMD) and the T-score used to clinically categorize bone quality (R ≥ 0.56), but there was poor correlation with age at all speeds (R ≤ 0.37). These artificial bones fail to replicate force and torque in human cortical bone during surgical drilling. To date, this is the largest series of human long bones biomechanically tested for surgical drilling.


  • A Preliminary Study of Platelet Activation After Embolization of Marrow Contents

    by Michael Blankstein, Robert J. Byrick, Masaki Nakane, Annie K. W. Bang, John Freedman, M. B. Garvey, Rad Zdero, Emil H. Md Schemitsch

    Objectives: Intravasation of bone marrow contents into venous circulation and pulmonary embolization after intramedullary nailing may be coupled with the activation of coagulation and fibrinolytic cascades. The objective of this study was to assess hemostatic response to pulmonary extravasated marrow contents. We hypothesize that activation of platelet activity and the coagulation cascade may occur after embolization of marrow contents in an experimental animal model of intramedullary nailing. Methods: Fifteen New Zealand white male rabbits were randomly assigned to control or fat embolism (FE) groups. In the FE group (n = 8), femurs were surgically instrumented with retrograde intramedullary nails and pressurized with bone cement. In the control group (n = 7), a sham knee incision was made that was immediately closed without drilling, reaming, or pressurization. Fibrinogen, D-dimer latex screen assay, 1 stage prothrombin time, and activated partial thromboplastin time were analyzed. Results: As the main platelet activation indicators, the marker Annexin-V percent binding increased in the FE group at 2 hours (P = 0.04) and 4 hours (P = 0.04), and the marker CD62P percent expression increased in the FE group at 2 hours (P = 0.04). Conclusions: This preliminary study showed that pressurization of marrow and intravasation of fat and marrow products cause activation of platelets and the coagulation cascade, with or without tissue trauma. This may be relevant to the treatment of multiply injured patients with prior respiratory and coagulation abnormalities. A future larger study may be needed.


  • The Physiologic and Pathologic Effects of the Reamer Irrigator Aspirator on Fat Embolism Outcome

    by Robert Y. Wang, Ru Li, Rad Zdero, David Bell, Michael Blankstein, Emil H. Md Schemitsch

    Objectives: Intramedullary reaming of long bones before nail insertion has been known to cause an increase in fat emboli introduction into the bloodstream, which is a potentially fatal phenomenon. The goal of this study was to assess whether the reamer irrigator aspirator (RIA) reamer can reduce fat embolic load compared with the standard AO reamer. Methods: Fifteen pigs were prepared using an intravenous catheter inserted into the marginal ear vein for fluid balance and drug administration. One third of the pig's blood volume was withdrawn to simulate hemorrhagic shock. Each animal underwent bilateral retrograde femoral reaming, cementing, and nailing using either an RIA or AO reamer. Assignment of a reamer type to the left or right side was done randomly and allowed for direct comparison of matching femur results. Outcome measures were obtained, namely, pulmonary arterial pressure, mean arterial pressure, partial pressure of arterial oxygen, and cardiac output. Staining techniques were used to ascertain fat emboli counts from lung tissue samples. Results: For mean arterial pressure, partial pressure of arterial oxygen, and cardiac output after cement injection, the RIA reamer group showed statistically higher values than the AO reamer group. In corollary, the RIA showed statistically lower pulmonary arterial pressure levels. No differences were noted at baseline, during hypovolemia, and post resuscitation. With the Student t test, no statistical differences were found between reamers regarding fat emboli counts for both staining methods. With the Mann–Whitney test, the RIA reamer showed statistically fewer emboli (7.0 versus 74.5) (P = 0.02, Z = 2.33) using Oil Red “O” staining. Conclusions: The RIA reamer demonstrated superior results with respect to physiologic measures and fat emboli counts and may provide optimal results compared with the AO reamer.


  • A Preliminary Biomechanical Study of Cyclic Preconditioning Effects on Canine Cadaveric Whole Femurs

    by Rad Zdero, Chris H. Gallimore, Alison J. McConnell, Harshita Patel, Rosane Nisenbaum, Golam Morshed, Henry Koo, Michael D. McKee, Emil H. Schemitsch, Habiba Bougherara

    Biomechanical preconditioning of biological specimens by cyclic loading is routinely done presumably to stabilize properties prior to the main phase of a study. However, no prior studies have actually measured these effects for whole bone of any kind. The aim of this study, therefore, was to quantify these effects for whole bones. Fourteen matched pairs of fresh-frozen intact cadaveric canine femurs were sinusoidally loaded in 4-point bending from 50 N to 300 N at 1 Hz for 25 cycles. All femurs were tested in both anteroposterior (AP) and mediolateral (ML) bending planes. Bending stiffness (i.e., slope of the force-vs-displacement curve) and linearity R2 (i.e., coefficient of determination) of each loading cycle were measured and compared statistically to determine the effect of limb side, cycle number, and bending plane. Stiffnesses rose from 809.7 to 867.7 N/mm (AP, left), 847.3 to 915.6 N/mm (AP, right), 829.2 to 892.5 N/mm (AP, combined), 538.7 to 580.4 N/mm (ML, left), 568.9 to 613.8 N/mm (ML, right), and 553.8 to 597.1 N/mm (ML, combined). Linearity R2 rose from 0.96 to 0.99 (AP, left), 0.97 to 0.99 (AP, right), 0.96 to 0.99 (AP, combined), 0.95 to 0.98 (ML, left), 0.94 to 0.98 (ML, right), and 0.95 to 0.98 (ML, combined). Stiffness and linearity R2 versus cycle number were well-described by exponential curves whose values leveled off, respectively, starting at 12 and 5 cycles. For stiffness, there were no statistical differences for left versus right femurs (p = 0.166), but there were effects due to cycle number (p < 0.0001) and AP versus ML bending plane (p < 0.0001). Similarly, for linearity, no statistical differences were noted due to limb side (p = 0.533), but there were effects due to cycle number (p < 0.0001) and AP versus ML bending plane (p = 0.006). A minimum of 12 preconditioning cycles was needed to fully stabilize both the stiffness and linearity of the canine femurs. This is the first study to measure the effects of mechanical preconditioning on whole bones, having some practical implications on research practices.


  • The Biomechanical Effect of Torsion on Humeral Shaft Repair Techniques for Completed Pathological Fractures

    by Ahmed Al-Jahwari, Emil H. Schemitsch, Jay S. Wunder, Peter C. Ferguson, Rad Zdero

    In the presence of a tumor defect, completed humeral shaft fractures continue to be a major surgical challenge since there is no “gold standard” treatment. This is due, in part, to the fact that only one prior biomechanical study exists on the matter, but which only compared 2 repair methods. The current authors measured the humeral torsional performance of 5 fixation constructs for completed pathological fractures. In 40 artificial humeri, a 2-cm hemi-cylindrical cortical defect with a transverse fracture was created in the lateral cortex. Specimens were divided into 5 different constructs and tested in torsion. Construct A was a broad 10-hole 4.5-mm dynamic compression plate (DCP). Construct B was the same as A except that the screw holes and the tumor defect were filled with bone cement and the screws were inserted into soft cement. Construct C was the same as A except that the canal and tumor defect were filled with bone cement and the screws were inserted into dry cement. Construct D was a locked intramedullary nail inserted in the antegrade direction. Construct E was the same as D except that bone cement filled the defect. For torsional stiffness, construct C (4.45 ± 0.20 Nm/deg) was not different than B or E (p > 0.16), but was higher than A and D (p < 0.001). For failure torque, construct C achieved a higher failure torque (69.65 ± 5.35 Nm) than other groups (p < 0.001). For the failure angle, there were no differences between plating constructs A to C (p ≥ 0.11), except for B versus C (p < 0.05), or between nailing groups D versus E (p = 0.97), however, all plating groups had smaller failure angles than both nailing groups (p < 0.05). For failure energy, construct C (17.97 ± 3.59 J) had a higher value than other groups (p < 0.005), except for A (p = 0.057). Torsional failure always occurred in the bone in the classic “spiral” pattern. Construct C provided the highest torsional stability for a completed pathological humeral shaft fracture.


  • Ideal Tibial Intramedullary Nail Insertion Point Varies With Tibial Rotation

    by Richard M Walker, Rad Zdero, Michael D MD McKee, James P Md Waddell, Emil H Md Schemitsch

    Objectives: The aim of the study was to investigate how superior entry point varies with tibial rotation and to identify landmarks that can be used to identify suitable radiographs for successful intramedullary nail insertion. Methods: The proximal tibia and knee were imaged for 12 cadaveric limbs undergoing 5° increments of internal and external rotation. Medial and lateral arthrotomies were performed, the ideal superior entry point was identified, and a 2-mm Kirschner wire inserted. A second Kirschner wire was sequentially placed at the 5-mm and then the 10-mm position, both medial and lateral to the initial Kirschner wire. Radiographs of the knee were obtained for all increments. The changing position of the ideal nail insertion point was recorded. Results: A 30° arc (range, 25°–40°) provided a suitable anteroposterior radiograph. On the neutral anteroposterior radiograph, the Kirschner wire was 54% ± 1.5% (range, 51–56%) from the medial edge of the tibial plateau. For every 5° of rotation, the Kirschner wire moved 3% of the plateau width. During external rotation, a misleading medial entry point was obtained. A fibular bisector line correlated with an entry point that was ideal or up to 5 mm lateral to this but never medial. The film that best showed the fibular bisector line was between 0° and 10° of internal rotation of the tibia. Conclusions: The fibula head bisector line can be used to avoid choosing external rotation views and, thus, avoid medial insertion points. The current results may help the surgeon prevent malalignment during intramedullary nailing in proximal tibial fractures.