J. Michael Hasenkam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
J. Michael Hasenkam has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Hans Nygaard
Institute of Experimental Clinical Research, Aarhus University Hospital, Skejby Sygehus, Aarhus, Denmark
11 shared publications - Morten Smerup
Department of Cardiothoracic & Vascular Surgery T and the Institute of Clinical Medicine, Aarhus University Hospital, Skejby, Denmark
7 shared publications Henrik Jensen
6 shared publicationsPer Wierup
6 shared publications- Peter Johansen
Department of Cardiothoracic and Vascular Research, Aarhus University Hospital, Skejby, Aarhus, Denmark
6 shared publications Steffen Ringgaard
6 shared publications
Latest Publications
- 1 January 2017
- Vol. 26 (1) , 63-71
How Heart Valves Evolve to Adapt to an Extreme-Pressure System: Morphologic and Biomechanical Properties of Giraffe Heart Valves.
Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid in developing techniques to design improved pressure-resistant biological heart valves. Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations. The aortic valve was shown to be 70% (95% CI 42-103%) stronger in the giraffe than in its bovine counterpart (p <0.001). No significant difference was found between mitral or pulmonary valves. After normalization for collagen, no significant differences were found in strength between species. The giraffe aortic valve was found to be significantly stiffer than the bovine aortic valve (p <0.001), with no significant difference between mitral and pulmonary valves. On a dry weight basis, the aortic (10.9%), pulmonary (4.3%), and mitral valves (9.6%) of giraffes contained significantly more collagen than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength, stiffness, and collagen content.
- 1 January 2017
- Vol. 26 (1) , 63-71
How Heart Valves Evolve to Adapt to an Extreme-Pressure System: Morphologic and Biomechanical Properties of Giraffe Heart Valves.
Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid in developing techniques to design improved pressure-resistant biological heart valves. Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations. The aortic valve was shown to be 70% (95% CI 42-103%) stronger in the giraffe than in its bovine counterpart (p <0.001). No significant difference was found between mitral or pulmonary valves. After normalization for collagen, no significant differences were found in strength between species. The giraffe aortic valve was found to be significantly stiffer than the bovine aortic valve (p <0.001), with no significant difference between mitral and pulmonary valves. On a dry weight basis, the aortic (10.9%), pulmonary (4.3%), and mitral valves (9.6%) of giraffes contained significantly more collagen than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength, stiffness, and collagen content.
- 1 July 2013
- Vol. 22 (4) , 524-31
Surgical relocation of the papillary muscles in functional ischemic mitral regurgitation: what are the forces of the relocation stitches acting on the myocardium?
In patients with chronic functional ischemic mitral regurgitation (FIMR), papillary muscle relocation has the potential to induce reverse left ventricular remodeling. However, in order to optimize function and durability, the forces imposed on the left ventricular myocardium by papillary muscle relocation should be assessed. Eight pigs with FIMR were subjected to down-sized ring annuloplasty in combination with relocation of the anterior (5 mm) and posterior (15 mm) papillary muscles towards the respective trigone. Papillary muscle relocation was obtained by a 2-0 expanded polytetrafluoroethylene stitch fixed to the trigone, exteriorized through the myocardium overlying the papillary muscle, and fixed to an epicardial disc. Tension in these stitches was measured at a systolic blood pressure > 80 mmHg using a custom-made sliding caliper with a strain gauge mounted in line. This allowed assessment of the cyclic change from minimal diastolic to maximum systolic papillary muscle relocation stitch tension. Maximum cyclic change in the posterior papillary muscle (PPM) stitch tension was 1.1 N at 15 mm relocation. In comparison, the anterior papillary muscle (APM) tension was increased to a maximum of 1.4 N with only 5 mm relocation. Surprisingly, during each step of isolated PPM relocation, the APM stitch tension increased concomitantly, but in contrast APM relocation did not influence the magnitude of PPM stitch tension. There was no statistically significant difference between cyclic changes in APM and PPM stitch tension at any step of relocation. Papillary muscle relocation using stitches attached between epicardial discs and respective trigones induced a cyclic change in papillary muscle relocation stitch tension of 1.1-1.4 N. These values were in the range of normal tension in the mitral valve apparatus, and equivalent to only 19-24% of the total papillary muscle forces. Therefore, this technique does not appear to induce a non-physiologically high cyclic load on the mitral valve complex.
- 1 July 2013
- Vol. 22 (4) , 524-31
Surgical relocation of the papillary muscles in functional ischemic mitral regurgitation: what are the forces of the relocation stitches acting on the myocardium?
In patients with chronic functional ischemic mitral regurgitation (FIMR), papillary muscle relocation has the potential to induce reverse left ventricular remodeling. However, in order to optimize function and durability, the forces imposed on the left ventricular myocardium by papillary muscle relocation should be assessed. Eight pigs with FIMR were subjected to down-sized ring annuloplasty in combination with relocation of the anterior (5 mm) and posterior (15 mm) papillary muscles towards the respective trigone. Papillary muscle relocation was obtained by a 2-0 expanded polytetrafluoroethylene stitch fixed to the trigone, exteriorized through the myocardium overlying the papillary muscle, and fixed to an epicardial disc. Tension in these stitches was measured at a systolic blood pressure > 80 mmHg using a custom-made sliding caliper with a strain gauge mounted in line. This allowed assessment of the cyclic change from minimal diastolic to maximum systolic papillary muscle relocation stitch tension. Maximum cyclic change in the posterior papillary muscle (PPM) stitch tension was 1.1 N at 15 mm relocation. In comparison, the anterior papillary muscle (APM) tension was increased to a maximum of 1.4 N with only 5 mm relocation. Surprisingly, during each step of isolated PPM relocation, the APM stitch tension increased concomitantly, but in contrast APM relocation did not influence the magnitude of PPM stitch tension. There was no statistically significant difference between cyclic changes in APM and PPM stitch tension at any step of relocation. Papillary muscle relocation using stitches attached between epicardial discs and respective trigones induced a cyclic change in papillary muscle relocation stitch tension of 1.1-1.4 N. These values were in the range of normal tension in the mitral valve apparatus, and equivalent to only 19-24% of the total papillary muscle forces. Therefore, this technique does not appear to induce a non-physiologically high cyclic load on the mitral valve complex.
- 1 March 2012
- Vol. 21 (2) , 181-8
Aortic root distensibility after subcoronary stentless valve implantation.
The preservation of aortic root dynamics is considered important for the durability of aortic valve bioprostheses. Stentless heart valves are believed to support physiologic biomechanics. To date, dynamic analysis has been limited to the full root prosthesis, and exclusively in the radial direction. The study aim was to investigate and compare the radial and longitudinal aortic root distensibilities of subcoronary stentless valves, and of stented and native pig valves. Stented pericardial (Mitroflow) or stentless (Solo, Toronto SPV) valve prostheses, or native porcine valves, were investigated in 32 pigs. Postoperatively, 12 sonomicrometry crystals were placed on the aortic root in order to measure aortic root distensibility, in both radial and longitudinal directions. Sonomicrometry data were obtained from 23 pigs (72%). At the annular level, the native and Solo valves were significantly more distensible in a radial direction than the Mitroflow valve (p = 0.04). However, at the level of the sinotubular junction (STJ), commissures and aorta, the native valve was significantly more distensible than all of the artificial valves (p = 0.006, p = 0.006, and p = 0.02, respectively). The Solo valve exhibited less longitudinal distensibility than the Toronto SPV and Mitroflow valves. The Toronto SPV initiated a radial expansion at the STJ significantly later in the cardiac cycle than did both the Solo and native valves (p = 0.03), but showed no difference compared to the Mitroflow valve. Longitudinal expansion between the annulus and the STJ started significantly earlier for the Solo valve than for both the Toronto SPV (p = 0.03) and Mitroflow (p = 0.02) valves. The Solo valve proved to be superior in maintaining annular distensibility immediately following implantation when compared to the Mitroflow valve. The Solo valve did not, however, preserve longitudinal distensibility as well as the other investigated valves. Finally, the Solo valve appeared to provide a more physiologic aortic root expansion pattern than its prosthetic counterparts.
- 1 March 2012
- Vol. 21 (2) , 181-8
Aortic root distensibility after subcoronary stentless valve implantation.
The preservation of aortic root dynamics is considered important for the durability of aortic valve bioprostheses. Stentless heart valves are believed to support physiologic biomechanics. To date, dynamic analysis has been limited to the full root prosthesis, and exclusively in the radial direction. The study aim was to investigate and compare the radial and longitudinal aortic root distensibilities of subcoronary stentless valves, and of stented and native pig valves. Stented pericardial (Mitroflow) or stentless (Solo, Toronto SPV) valve prostheses, or native porcine valves, were investigated in 32 pigs. Postoperatively, 12 sonomicrometry crystals were placed on the aortic root in order to measure aortic root distensibility, in both radial and longitudinal directions. Sonomicrometry data were obtained from 23 pigs (72%). At the annular level, the native and Solo valves were significantly more distensible in a radial direction than the Mitroflow valve (p = 0.04). However, at the level of the sinotubular junction (STJ), commissures and aorta, the native valve was significantly more distensible than all of the artificial valves (p = 0.006, p = 0.006, and p = 0.02, respectively). The Solo valve exhibited less longitudinal distensibility than the Toronto SPV and Mitroflow valves. The Toronto SPV initiated a radial expansion at the STJ significantly later in the cardiac cycle than did both the Solo and native valves (p = 0.03), but showed no difference compared to the Mitroflow valve. Longitudinal expansion between the annulus and the STJ started significantly earlier for the Solo valve than for both the Toronto SPV (p = 0.03) and Mitroflow (p = 0.02) valves. The Solo valve proved to be superior in maintaining annular distensibility immediately following implantation when compared to the Mitroflow valve. The Solo valve did not, however, preserve longitudinal distensibility as well as the other investigated valves. Finally, the Solo valve appeared to provide a more physiologic aortic root expansion pattern than its prosthetic counterparts.
- Open Access
- 22 August 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 100
Subcoronary versus supracoronary aortic stenosis. an experimental evaluation
Background: Valvular aortic stenosis is the most common cause of left ventricular hypertrophy due to gradually increasing pressure work. As the stenosis develop the left ventricular hypertrophy may lead to congestive heart failure, increased risk of perioperative complications and also increased risk of sudden death. A functional porcine model imitating the pathophysiological nature of valvular aortic stenosis is very much sought after in order to study the geometrical and pathophysiological changes of the left ventricle, timing of surgery and also pharmacological therapy in this patient group. Earlier we developed a porcine model for aortic stenosis based on supracoronary aortic banding, this model may not completely imitate the pathophysiological changes that occurs when valvular aortic stenosis is present including the coronary blood flow. It would therefore be desirable to optimize this model according to the localization of the stenosis. Methods: In 20 kg pigs subcoronary (n = 8), supracoronary aortic banding (n = 8) or sham operation (n = 4) was preformed via a left lateral thoracotomy. The primary endpoint was left ventricular wall thickness; secondary endpoints were heart/body weight ratio and the systolic/diastolic blood flow ratio in the left anterior descending coronary. Statistical evaluation by oneway anova and unpaired t-test. Results: Sub- and supracoronary banding induce an equal degree of left ventricular hypertrophy compared with the control group. The coronary blood flow ratio was slightly but not significantly higher in the supracoronary group (ratio = 0.45) compared with the two other groups (subcoronary ratio = 0.36, control ratio = 0.34). Conclusions: A human pathophysiologically compatible porcine model for valvular aortic stenosis was developed by performing subcoronary aortic banding. Sub- and supracoronary aortic banding induce an equal degree of left ventricular hypertrophy. This model may be valid for experimental investigations of aortic valve stenosis but studies of left ventricular hypertrophy can be studied equally well by graduated constriction of the ascending aorta.
- 22 August 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 100
Open AccessSubcoronary versus supracoronary aortic stenosis. an experimental evaluation
Background: Valvular aortic stenosis is the most common cause of left ventricular hypertrophy due to gradually increasing pressure work. As the stenosis develop the left ventricular hypertrophy may lead to congestive heart failure, increased risk of perioperative complications and also increased risk of sudden death. A functional porcine model imitating the pathophysiological nature of valvular aortic stenosis is very much sought after in order to study the geometrical and pathophysiological changes of the left ventricle, timing of surgery and also pharmacological therapy in this patient group. Earlier we developed a porcine model for aortic stenosis based on supracoronary aortic banding, this model may not completely imitate the pathophysiological changes that occurs when valvular aortic stenosis is present including the coronary blood flow. It would therefore be desirable to optimize this model according to the localization of the stenosis. Methods: In 20 kg pigs subcoronary (n = 8), supracoronary aortic banding (n = 8) or sham operation (n = 4) was preformed via a left lateral thoracotomy. The primary endpoint was left ventricular wall thickness; secondary endpoints were heart/body weight ratio and the systolic/diastolic blood flow ratio in the left anterior descending coronary. Statistical evaluation by oneway anova and unpaired t-test. Results: Sub- and supracoronary banding induce an equal degree of left ventricular hypertrophy compared with the control group. The coronary blood flow ratio was slightly but not significantly higher in the supracoronary group (ratio = 0.45) compared with the two other groups (subcoronary ratio = 0.36, control ratio = 0.34). Conclusions: A human pathophysiologically compatible porcine model for valvular aortic stenosis was developed by performing subcoronary aortic banding. Sub- and supracoronary aortic banding induce an equal degree of left ventricular hypertrophy. This model may be valid for experimental investigations of aortic valve stenosis but studies of left ventricular hypertrophy can be studied equally well by graduated constriction of the ascending aorta.
- Open Access
- 15 May 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 72
Degenerative processes in bioprosthetic mitral valves in juvenile pigs
Background: Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. Materials: The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. Results: Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00) and 1.20 (SD = ±0.25), respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55) and 6.51 mmHg (SD = ±2.57), respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. Conclusions: Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.
- 15 May 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 72
Open AccessDegenerative processes in bioprosthetic mitral valves in juvenile pigs
Background: Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. Materials: The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. Results: Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00) and 1.20 (SD = ±0.25), respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55) and 6.51 mmHg (SD = ±2.57), respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. Conclusions: Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.
- 1 January 2011
- Published by Bentham Science Publishers Ltd. in Current Signal Transduction Therapy
- Vol. 6 (1) , 65-70
Multiplex Analysis of Cardiac Hypertrophic Signaling: Reduced in vivo Phosphorylation of Glycogen Synthase Kinase-3β and Proline-Rich Akt Substrate (PRAS40)
The serine/threonine kinase Akt (PKB) is activated in response to growth factors, cytokines and other growth promoting stimuli and is involved in the regulation of a number of cellular processes including metabolism, cell growth, proliferation and survival. To study intracellular metabolic effects of left ventricular hypertrophy (LVH) induced by chronic aortic banding in a recently established swine model, protein arrays can be used to analyze changes in cytosolic protein phosphorylation levels such as cell signal transduction and protein kinase pathways. Miniaturized sandwich immunoassays allow the simultaneous analysis of several parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. Cytosolic proteins were extracted from pig hearts. Using the bead-based Luminex system, multiplexed sandwich immunoassays have been developed to analyze the phosphorylated proteins IR[pYpY1162/1163], IGF-1R[pYpY1135 /1136], IRS-1[pS312], Akt[pS473], PRAS40[pT246], p70S6K[pTpS421/424], and GSK-3β[pS9], which were measured simultaneously in extracted myocardial tissue homogenates with the Akt Pathway Phospho 7-Plex Panel using a Luminex 100 IS system. Using this assay, tissue homogenates derived from myocardial tissue samples from 28 individual porcine in vivo model experiments in normal hearts (n=17) and LVH hearts (n=11) were analyzed for phosphorylated protein concentrations. Results obtained allowed grouping of myocardial tissue samples into a LVH and a normal group. Two candidate molecules: PRAS40 (normal vs. LVH two-tailed probability P= 0.0022) and GSK-3β (P=0.003), had lower concentrations in LVH pigs than in normal animals, suggesting loss of GSK-3β inhibitory activity and contributing to speculation of altered insulin sensitivity associated with LVH.
- 1 January 2011
- Published by Bentham Science Publishers Ltd. in Current Signal Transduction Therapy
- Vol. 6 (1) , 65-70
Multiplex Analysis of Cardiac Hypertrophic Signaling: Reduced in vivo Phosphorylation of Glycogen Synthase Kinase-3β and Proline-Rich Akt Substrate (PRAS40)
The serine/threonine kinase Akt (PKB) is activated in response to growth factors, cytokines and other growth promoting stimuli and is involved in the regulation of a number of cellular processes including metabolism, cell growth, proliferation and survival. To study intracellular metabolic effects of left ventricular hypertrophy (LVH) induced by chronic aortic banding in a recently established swine model, protein arrays can be used to analyze changes in cytosolic protein phosphorylation levels such as cell signal transduction and protein kinase pathways. Miniaturized sandwich immunoassays allow the simultaneous analysis of several parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. Cytosolic proteins were extracted from pig hearts. Using the bead-based Luminex system, multiplexed sandwich immunoassays have been developed to analyze the phosphorylated proteins IR[pYpY1162/1163], IGF-1R[pYpY1135 /1136], IRS-1[pS312], Akt[pS473], PRAS40[pT246], p70S6K[pTpS421/424], and GSK-3β[pS9], which were measured simultaneously in extracted myocardial tissue homogenates with the Akt Pathway Phospho 7-Plex Panel using a Luminex 100 IS system. Using this assay, tissue homogenates derived from myocardial tissue samples from 28 individual porcine in vivo model experiments in normal hearts (n=17) and LVH hearts (n=11) were analyzed for phosphorylated protein concentrations. Results obtained allowed grouping of myocardial tissue samples into a LVH and a normal group. Two candidate molecules: PRAS40 (normal vs. LVH two-tailed probability P= 0.0022) and GSK-3β (P=0.003), had lower concentrations in LVH pigs than in normal animals, suggesting loss of GSK-3β inhibitory activity and contributing to speculation of altered insulin sensitivity associated with LVH.
- 1 November 2010
- Vol. 19 (6) , 692-700
Does down-sized ring annuloplasty induce papillary muscle relocation in ischemic mitral regurgitation?
Down-sized ring annuloplasty has been shown to induce left ventricular remodeling in patients with functional ischemic mitral regurgitation (FIMR). To determine if this remodeling comprised papillary muscle (PM) relocation, a chronic FIMR porcine model was used to assess the impact on three-dimensional (3D) PM positioning, by implanting a down-sized rigid ring annuloplasty. Six out of ten FIMR pigs that underwent a down-sized mitral ring annuloplasty (CE Classic size 26-28) survived for six weeks postoperatively. 3D cardiac magnetic resonance imaging was carried out at one week preoperatively, and repeated at one and six weeks postoperatively, to assess the direct distances (in mm) from the anterior papillary muscle (APM) and posterior papillary muscle (PPM) to each trigone. Three reference planes were also constructed to determine APM and PPM displacement in the lateral, anterioposterior, and apical directions. Relative to the preoperative situation, at one week postoperatively a reduced displacement of the APM was observed in an anterior direction (from 18.8 to 16.2 mm; p < 0.05) and from the posterior trigone (from 40.5 to 37.4 mm; p < 0.05) at end-diastole. Relative to one week postoperatively, at six weeks postoperatively a reduced PPM displacement was observed from the anterior trigone (43.0 versus 42.0 mm; p < 0.05) at end-systole. Relative to the preoperative situation, no overall tendency of surgically induced PM relocation was observed at one or six weeks postoperatively. A down-sized ring annuloplasty did not induce an overall pattern of PM relocation in pigs with chronic FIMR.
- 1 November 2010
- Vol. 19 (6) , 692-700
Does down-sized ring annuloplasty induce papillary muscle relocation in ischemic mitral regurgitation?
Down-sized ring annuloplasty has been shown to induce left ventricular remodeling in patients with functional ischemic mitral regurgitation (FIMR). To determine if this remodeling comprised papillary muscle (PM) relocation, a chronic FIMR porcine model was used to assess the impact on three-dimensional (3D) PM positioning, by implanting a down-sized rigid ring annuloplasty. Six out of ten FIMR pigs that underwent a down-sized mitral ring annuloplasty (CE Classic size 26-28) survived for six weeks postoperatively. 3D cardiac magnetic resonance imaging was carried out at one week preoperatively, and repeated at one and six weeks postoperatively, to assess the direct distances (in mm) from the anterior papillary muscle (APM) and posterior papillary muscle (PPM) to each trigone. Three reference planes were also constructed to determine APM and PPM displacement in the lateral, anterioposterior, and apical directions. Relative to the preoperative situation, at one week postoperatively a reduced displacement of the APM was observed in an anterior direction (from 18.8 to 16.2 mm; p < 0.05) and from the posterior trigone (from 40.5 to 37.4 mm; p < 0.05) at end-diastole. Relative to one week postoperatively, at six weeks postoperatively a reduced PPM displacement was observed from the anterior trigone (43.0 versus 42.0 mm; p < 0.05) at end-systole. Relative to the preoperative situation, no overall tendency of surgically induced PM relocation was observed at one or six weeks postoperatively. A down-sized ring annuloplasty did not induce an overall pattern of PM relocation in pigs with chronic FIMR.
- 1 September 2010
- Vol. 19 (5) , 584-92
Recellularization of decellularized mitral heart valves in juvenile pigs.
Glutaraldehyde-preserved bioprosthetic heart valves are non-viable and have a limited durability because of calcification, tissue wear, and inflammation, especially in children. Decellularized porcine heart valves, when treated with deoxycholic acid (DOA), have exhibited complete recellularization and an absence of calcification when implanted into the pulmonary position in juvenile sheep. The study aim was to determine the degree of recellularization and calcification in DOA-treated heart valve prostheses in the mitral position in juvenile pigs. A mitral heart valve prosthesis was implanted into each of 17 pigs, and subsequently explanted and fixed in formaldehyde after between five and 26 weeks. A gross pathologic assessment, high-resolution X-ray imaging and histological examination were then performed on each valve. Eight pigs survived the observational period. Five valves had only a slight fibrin deposition and calcification foci within the fibrin deposits. Three valves had severe thrombotic material deposits with disseminated calcification and valve stenosis, and one valve had infective endocarditis. A myofibroblast-like cell ingrowth was observed at different locations of the valve housing in all explanted heart valves, but ingrowth in the basal part of the cusp matrix was limited. In four valve prostheses, endothelial cells covered up to 10% of the cusp surface after six months. Inflammatory cells were observed in large numbers in those valves showing endocarditis and severe thrombosis, but in only limited numbers in the other valves. All valves showed the deposition of fibrin and platelet material, in three cases to a severe degree. A limited ingrowth of both endothelial and myofibroblast-like cells was observed in five valves in which calcification was limited to a few commissural foci. The non-endothelialized surface of the decellularized valves makes them very susceptible to platelet and fibrin deposition; however, slow revitalization seems possible.
- 1 September 2010
- Vol. 19 (5) , 584-92
Recellularization of decellularized mitral heart valves in juvenile pigs.
Glutaraldehyde-preserved bioprosthetic heart valves are non-viable and have a limited durability because of calcification, tissue wear, and inflammation, especially in children. Decellularized porcine heart valves, when treated with deoxycholic acid (DOA), have exhibited complete recellularization and an absence of calcification when implanted into the pulmonary position in juvenile sheep. The study aim was to determine the degree of recellularization and calcification in DOA-treated heart valve prostheses in the mitral position in juvenile pigs. A mitral heart valve prosthesis was implanted into each of 17 pigs, and subsequently explanted and fixed in formaldehyde after between five and 26 weeks. A gross pathologic assessment, high-resolution X-ray imaging and histological examination were then performed on each valve. Eight pigs survived the observational period. Five valves had only a slight fibrin deposition and calcification foci within the fibrin deposits. Three valves had severe thrombotic material deposits with disseminated calcification and valve stenosis, and one valve had infective endocarditis. A myofibroblast-like cell ingrowth was observed at different locations of the valve housing in all explanted heart valves, but ingrowth in the basal part of the cusp matrix was limited. In four valve prostheses, endothelial cells covered up to 10% of the cusp surface after six months. Inflammatory cells were observed in large numbers in those valves showing endocarditis and severe thrombosis, but in only limited numbers in the other valves. All valves showed the deposition of fibrin and platelet material, in three cases to a severe degree. A limited ingrowth of both endothelial and myofibroblast-like cells was observed in five valves in which calcification was limited to a few commissural foci. The non-endothelialized surface of the decellularized valves makes them very susceptible to platelet and fibrin deposition; however, slow revitalization seems possible.
- 1 July 2010
- Vol. 19 (4) , 492-8
Leaflet opening and closing dynamics of stentless bioprostheses.
Stiffening of the aortic root may entail asynchronous aortic leaflet movement, and result in enhanced flexion-stress in specific areas of the cusps. As stentless prostheses are more flexible than their stented counterparts, they are more likely to exhibit physiologic leaflet movements. The study aim was to compare leaflet movement dynamics in stented versus non-stented aortic valves implanted in pigs. Aortic bioprostheses were implanted surgically into adult pigs as follows: stented Mitroflow (n = 6), stentless Solo (n = 5), and stentless Toronto SPV (n = 4). In five control animals, the native aortic valve leaflets were untouched. Postoperatively, the aortic valve was displayed by epicardial echocardiography. M-mode display of the non-coronary leaflet was applied to assess rapid valve-opening velocity (V(open)) and rapid valve-closing velocity (V(close)). The mean V(open) values were 29.2, 25.5, 37.8, and 31.9 cm/s, respectively, for the native, Toronto SPV, Solo, and Mitroflow valves. The mean V(close) values were 23.2, 21.9, 34.1, and 34.3 cm/s, respectively. A comparison of V(open) values showed no statistically significant difference between the valves. The Mitroflow and Solo valves yielded significantly higher V(close) values than the native and Toronto SPV valves. The Toronto SPV exhibited marked systolic leaflet folding. The stent of a bioprosthetic valve does not appear to affect leaflet velocities when compared to the stentless bioprosthetic valve. The Solo and Mitroflow valves closed more abruptly than the porcine native aortic valve; however, the Toronto SPV valve displayed diverging systolic leaflet movement patterns.
- 1 July 2010
- Vol. 19 (4) , 492-8
Leaflet opening and closing dynamics of stentless bioprostheses.
Stiffening of the aortic root may entail asynchronous aortic leaflet movement, and result in enhanced flexion-stress in specific areas of the cusps. As stentless prostheses are more flexible than their stented counterparts, they are more likely to exhibit physiologic leaflet movements. The study aim was to compare leaflet movement dynamics in stented versus non-stented aortic valves implanted in pigs. Aortic bioprostheses were implanted surgically into adult pigs as follows: stented Mitroflow (n = 6), stentless Solo (n = 5), and stentless Toronto SPV (n = 4). In five control animals, the native aortic valve leaflets were untouched. Postoperatively, the aortic valve was displayed by epicardial echocardiography. M-mode display of the non-coronary leaflet was applied to assess rapid valve-opening velocity (V(open)) and rapid valve-closing velocity (V(close)). The mean V(open) values were 29.2, 25.5, 37.8, and 31.9 cm/s, respectively, for the native, Toronto SPV, Solo, and Mitroflow valves. The mean V(close) values were 23.2, 21.9, 34.1, and 34.3 cm/s, respectively. A comparison of V(open) values showed no statistically significant difference between the valves. The Mitroflow and Solo valves yielded significantly higher V(close) values than the native and Toronto SPV valves. The Toronto SPV exhibited marked systolic leaflet folding. The stent of a bioprosthetic valve does not appear to affect leaflet velocities when compared to the stentless bioprosthetic valve. The Solo and Mitroflow valves closed more abruptly than the porcine native aortic valve; however, the Toronto SPV valve displayed diverging systolic leaflet movement patterns.
- 1 May 2010
- Vol. 19 (3) , 292-303
In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves.
Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. The native valves had a significantly lower peak velocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: 229 +/- 18 cm/s). The native valves exhibited a flat velocity profile during systole, whereas the Solo valve, and especially the Toronto SPV valve, displayed more parabola-shaped velocity profiles; velocity profiles downstream of the Mitroflow valve exhibited a flat shape. The native valves had a lower mean velocity gradient at peak systole (p < 0.0001). The velocity gradient percentage above mean was lowest for the native valve (0.14 +/- 0.11; p < 0.0001), while the Mitroflow valve had a percentage of 0.57 +/- 0.09, which was lower than the Solo valve (0.69 +/- 0.12; p = 0.074), and significantly lower than the Toronto valve (0.70 +/- 0.08; p = 0.015). All valves displayed high velocity gradients adjacent to the aortic wall; in particular, the Toronto SPV which also had high velocity gradients at the center of the vessel. All of the artificial valves tested had a significantly higher mean velocity gradient and peak velocity than the native valves. However, the Mitroflow had a mean velocity and a velocity gradient percentage lower than the two stentless valves. The Solo and Mitroflow valves displayed velocity profiles most like native valves, while the Toronto valve had a more irregular asymmetric velocity profile.
- 1 May 2010
- Vol. 19 (3) , 292-303
In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves.
Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. The native valves had a significantly lower peak velocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: 229 +/- 18 cm/s). The native valves exhibited a flat velocity profile during systole, whereas the Solo valve, and especially the Toronto SPV valve, displayed more parabola-shaped velocity profiles; velocity profiles downstream of the Mitroflow valve exhibited a flat shape. The native valves had a lower mean velocity gradient at peak systole (p < 0.0001). The velocity gradient percentage above mean was lowest for the native valve (0.14 +/- 0.11; p < 0.0001), while the Mitroflow valve had a percentage of 0.57 +/- 0.09, which was lower than the Solo valve (0.69 +/- 0.12; p = 0.074), and significantly lower than the Toronto valve (0.70 +/- 0.08; p = 0.015). All valves displayed high velocity gradients adjacent to the aortic wall; in particular, the Toronto SPV which also had high velocity gradients at the center of the vessel. All of the artificial valves tested had a significantly higher mean velocity gradient and peak velocity than the native valves. However, the Mitroflow had a mean velocity and a velocity gradient percentage lower than the two stentless valves. The Solo and Mitroflow valves displayed velocity profiles most like native valves, while the Toronto valve had a more irregular asymmetric velocity profile.