    • 1 March 2012
      • Vol. 21  (2) , 181-8

    Aortic root distensibility after subcoronary stentless valve implantation.

    by Jonas A Funder, Markus W Frost, Kaj-Erik Klaaborg, Per Wierup, Vibeke Hjortdal, Hans Nygaard, J Michael Hasenkam

    The preservation of aortic root dynamics is considered important for the durability of aortic valve bioprostheses. Stentless heart valves are believed to support physiologic biomechanics. To date, dynamic analysis has been limited to the full root prosthesis, and exclusively in the radial direction. The study aim was to investigate and compare the radial and longitudinal aortic root distensibilities of subcoronary stentless valves, and of stented and native pig valves. Stented pericardial (Mitroflow) or stentless (Solo, Toronto SPV) valve prostheses, or native porcine valves, were investigated in 32 pigs. Postoperatively, 12 sonomicrometry crystals were placed on the aortic root in order to measure aortic root distensibility, in both radial and longitudinal directions. Sonomicrometry data were obtained from 23 pigs (72%). At the annular level, the native and Solo valves were significantly more distensible in a radial direction than the Mitroflow valve (p = 0.04). However, at the level of the sinotubular junction (STJ), commissures and aorta, the native valve was significantly more distensible than all of the artificial valves (p = 0.006, p = 0.006, and p = 0.02, respectively). The Solo valve exhibited less longitudinal distensibility than the Toronto SPV and Mitroflow valves. The Toronto SPV initiated a radial expansion at the STJ significantly later in the cardiac cycle than did both the Solo and native valves (p = 0.03), but showed no difference compared to the Mitroflow valve. Longitudinal expansion between the annulus and the STJ started significantly earlier for the Solo valve than for both the Toronto SPV (p = 0.03) and Mitroflow (p = 0.02) valves. The Solo valve proved to be superior in maintaining annular distensibility immediately following implantation when compared to the Mitroflow valve. The Solo valve did not, however, preserve longitudinal distensibility as well as the other investigated valves. Finally, the Solo valve appeared to provide a more physiologic aortic root expansion pattern than its prosthetic counterparts.

    • 1 July 2010
      • Vol. 19  (4) , 492-8

    Leaflet opening and closing dynamics of stentless bioprostheses.

    by Markus Winther Frost, Jonas A Funderl, Kaj Erik Klaaborg, Per Wierup, Erik Sloth, Hans Nygaard, J Michael Hasenkam

    Stiffening of the aortic root may entail asynchronous aortic leaflet movement, and result in enhanced flexion-stress in specific areas of the cusps. As stentless prostheses are more flexible than their stented counterparts, they are more likely to exhibit physiologic leaflet movements. The study aim was to compare leaflet movement dynamics in stented versus non-stented aortic valves implanted in pigs. Aortic bioprostheses were implanted surgically into adult pigs as follows: stented Mitroflow (n = 6), stentless Solo (n = 5), and stentless Toronto SPV (n = 4). In five control animals, the native aortic valve leaflets were untouched. Postoperatively, the aortic valve was displayed by epicardial echocardiography. M-mode display of the non-coronary leaflet was applied to assess rapid valve-opening velocity (V(open)) and rapid valve-closing velocity (V(close)). The mean V(open) values were 29.2, 25.5, 37.8, and 31.9 cm/s, respectively, for the native, Toronto SPV, Solo, and Mitroflow valves. The mean V(close) values were 23.2, 21.9, 34.1, and 34.3 cm/s, respectively. A comparison of V(open) values showed no statistically significant difference between the valves. The Mitroflow and Solo valves yielded significantly higher V(close) values than the native and Toronto SPV valves. The Toronto SPV exhibited marked systolic leaflet folding. The stent of a bioprosthetic valve does not appear to affect leaflet velocities when compared to the stentless bioprosthetic valve. The Solo and Mitroflow valves closed more abruptly than the porcine native aortic valve; however, the Toronto SPV valve displayed diverging systolic leaflet movement patterns.

    • 1 May 2010
      • Vol. 19  (3) , 292-303

    In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves.

    by Jonas A Funder, Markus W Frost, Steffen Ringgaard, Kaj-Erik Klaaborg, Per Wierup, Vibeke Hjortdal, Hans Nygaard, J Michael Hasenkam

    Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. The native valves had a significantly lower peak velocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: 229 +/- 18 cm/s). The native valves exhibited a flat velocity profile during systole, whereas the Solo valve, and especially the Toronto SPV valve, displayed more parabola-shaped velocity profiles; velocity profiles downstream of the Mitroflow valve exhibited a flat shape. The native valves had a lower mean velocity gradient at peak systole (p < 0.0001). The velocity gradient percentage above mean was lowest for the native valve (0.14 +/- 0.11; p < 0.0001), while the Mitroflow valve had a percentage of 0.57 +/- 0.09, which was lower than the Solo valve (0.69 +/- 0.12; p = 0.074), and significantly lower than the Toronto valve (0.70 +/- 0.08; p = 0.015). All valves displayed high velocity gradients adjacent to the aortic wall; in particular, the Toronto SPV which also had high velocity gradients at the center of the vessel. All of the artificial valves tested had a significantly higher mean velocity gradient and peak velocity than the native valves. However, the Mitroflow had a mean velocity and a velocity gradient percentage lower than the two stentless valves. The Solo and Mitroflow valves displayed velocity profiles most like native valves, while the Toronto valve had a more irregular asymmetric velocity profile.

    • 1 September 2008
      • Vol. 17  (5) , 579-82

    Are sounds from mechanical heart valves equal for different valve types?

    by Thais A L Pedersen, Peter Johansen, J Michael Hasenkam, Reiner Koerfer, Heinrich Koertke, Hans Nygaard

    The closing 'click' sounds from mechanical heart valve prostheses are often clearly audible for patients and their relatives. These sounds have been recognized as a disturbing factor causing sleeping disturbances or social embarrassment, which patients must endure for the rest of their lives. The study aim was to determine whether the intensity of the transmitted sounds varies according to the type of valve implanted. Closing sounds were measured from 15 patients with ATS valves, 29 with Medtronic-Hall valves, and 40 with St. Jude Medical (SJM) valve prostheses; all prostheses were implanted in the aortic position. The sounds were recorded by a microphone placed 5 cm above the chest of the patient when placed in a supine position in a bioacoustical laboratory. The mean sound pressure levels (SPLs) from the valves were measured in dB(A). The mean SPL values were 43 +/- 5 dB(A) for ATS valves, 41 +/- 4 dB(A) for Medtronic-Hall valves and 40 +/- 4 dB(A) for SJM valves (p < 0.05, ATS versus SJM). The study results showed a statistically significant difference in SPLs among the three investigated mechanical heart valve prostheses. The highest levels were in the ATS valves, and the lowest in the SJM valves. These objectively measured SPLs must be correlated with the sound as perceived by the patient in order to determine the annoyance that they cause.


    • 1 May 2008
      • Vol. 17  (3) , 267

    What forces act on a flat rigid mitral annuloplasty ring?

    by Morten Ø Jensen, Henrik Jensen, Sten L Nielsen, Morten Smerup, Peter Johansen, Ajit P Yoganathan, Hans Nygaard, J Michael Hasenkam

    Increasing mitral valve repair durability requires successful restoration and support with annuloplasty rings. The stress distribution in these devices indirectly determines the success of the repair. It is hypothesized that changes in annular geometry throughout the cardiac cycle result in adverse strain distribution in stiff, flat annuloplasty rings, and hence non-physiological loading of the myocardium. The study aim was to identify the three-dimensional (3-D) force distribution in mitral annuloplasty rings. Eight animals were included in an acute porcine study. The mitral annulus 3-D dynamic geometry was assessed with sonomicrometry prior to ring insertion. Strain gauges mounted on dedicated D-shaped rigid flat annuloplasty rings enabled dynamic force measurements to be made perpendicular to the annulus plane. The average systolic annular height to commissural width ratio before ring implantation was 13.7 +/- 1.4%. Following ring implantation, the annulus was fixed in the diastolic flat configuration (p <0.01). Force accumulation was seen from the anterior (0.7 +/- 0.4 N) and commissural (1.4 +/- 1.0 N) annular segments; both forces were acting in opposite directions and were statistically significantly larger than zero (p <0.01; n = 8). These data demonstrate highest strains at the anterior and commissural areas of flat mitral annuloplasty rings, and support the hypothesis that the mitral valve annulus and its attached valvular and subvalvular structures apply systolic torque onto the flat annuloplasty ring in an attempt to conform it into the saddle-shaped configuration.


    • 1 July 2004
      • Vol. 13  (4) , 651-8

    In-vivo prediction of cavitation near a Medtronic Hall valve.

    by Peter Johansen, Tina S Andersen, J Michael Hasenkam, Hans Nygaard

    Quantification of cavitation near mechanical heart valves in vivo is currently based on measurements of high-frequency pressure fluctuations (HFPF). Until now, mechanical resonance components have been removed using a high-pass filter. However, isolating cavitation and resonance signal components by separating the deterministic and non-deterministic parts of the HFPF signal has recently been proposed as a new method. It was hypothesized that the non-deterministic signal energy, Enon-det, of the HFPF signal correlates with previous parameters indicating cavitation in vivo, specifically the root mean square pressure after appropriate high-pass filtering (P(RMS)) and the rate of change in transvalvular pressure with respect to time (dP/dt). Medtronic Hall 29 mm mitral valves were implanted in five pigs (body weight 80 kg). The hemodynamic condition was varied by infusion of dobutamine and blood volume regulation to achieve a wide range of dP/dt (100 to 4,700 mmHg/s). According to previous studies, P(RMS) was deduced using the HP-filtering cut-off frequency of 50 kHz for this particular valve. The transvalvular dP/dt was derived as the average slope 5 ms prior to valve closure. Power relationships were found between Enon-det and P(RMS) (P(RMS) = 1.27 x Enon-det0.49), and between Enon-det and dP/dt. The correlation between Enon-det and P(RMS) was very strong (r = 0.98), whereas the correlation between Enon-det and dP/dt was notably weaker (r = 0.68). Enon-det was an excellent predictor of P(RMS), obtained after appropriate filtering. The present data suggested that the signal energy above 50 kHz was almost completely non-deterministic. It can therefore be proposed that Enon-det is a more direct and easily accessible parameter than those previously suggested for the purpose of cavitation quantification. This parameter is able to quantify the pressure fluctuations thought to occur from cavitation in vivo, and may be applicable for non-invasive recordings.


  • MRI assessment of the influence of body position on the shape and position of the urinary bladder

    by Niels Kristian Kristiansen, Steffen Ringgaard, Hans Nygaard, Jens Christian Djurhuus

    Objective: Continuous surveillance of patients' bladder volume may be of benefit during the treatment of various urologic disorders. In order to design optimal bladder volume monitoring equipment, information about the shape and position of the bladder, not at least in relation to posture, is crucial. The purpose of this study was consequently to evaluate the influence of body position on the change in shape and position of the bladder. Material and Methods: MRI was performed in three young volunteers during posture changes. MRI scans in the transverse, frontal and sagittal planes were recorded in bladders of various sizes. The position of the bladder midpoint in the three planes was determined. Moreover, to account for its shape, the compactness of the cross‐section of the bladder was calculated on the basis of its perimeter and area. Results: For the medial–lateral and cranial–caudal positions, the maximal displacements were 4 and 5 mm, respectively. In the ventral–dorsal direction the displacement varied, but was Conclusion: In young subjects, the position and shape of the bladder only change modestly for different body positions, thus eliminating the need for special correction measures when designing bladder volume monitoring equipment.


    • 1 November 2003
      • Vol. 12  (6) , 764-71

    Noise levels of closing sounds in vivo are equal for different bileaflet mechanical heart valves.

    by Peter Johansen, Søren Berndt Hansen, J Michael Hasenkam, Hans Nygaard

    Patients with mechanical heart valves must endure the valve's closing sounds for the rest of their life. Sound pressure levels (SPLs) recorded show wide patient-to-patient variation, even for the same type of valve. The variation was attributed to body constitution variability and differences in hemodynamic status. It was hypothesized that aortic mechanical valves generate closing clicks which correlate in magnitude with hemodynamic parameters, such as the rate of relaxation of the left ventricle (dp/dt) and potential energy stored in the aortic windkessel. Three different aortic mechanical heart valves were investigated in a porcine model (n = 9), namely St. Jude Medical, CarboMedics and ATS. Closing sounds were measured with a microphone placed in a portable anechoic chamber 10 cm above the exposed heart. Left ventricular pressure (LVP) and cardiac output were also measured. Different hemodynamic conditions were produced by intravenous infusion of isotonic saline and dobutamine. Volume regulation and atrial pacing were also applied. Different hemodynamic situations were established (cardiac output, 1.2-6.5 l/min; heart rate, 99-171 bpm). The measured mean SPLs were 49.5-53.9 dB(A), and there were no statistically significant differences in noise between the valves (p = 0.8; one-way ANOVA). Likewise, only a weak relationship was identified between different hemodynamic parameters and the SPLs recorded. The SPLs of the investigated bileaflet mechanical heart valves did not differ significantly. Moreover, the SPL was only weakly related to LVP during closure and estimated stroke work.


    • 1 November 2003
      • Vol. 12  (6) , 790-6

    Indication of cavitation in mechanical heart valve patients.

    by Tina S Andersen, Peter Johansen, Peter K Paulsen, Hans Nygaard, J Michael Hasenkam

    Cavitation may cause erosion of prosthetic heart valve material. The phenomenon has been extensively studied in vitro, and an association between the presence of cavitation bubbles and high-frequency pressure fluctuations (HFPF) has been established. In-vivo studies examining this phenomenon are scarce; hence, the study aim was to compare HFPF in patients with native, bioprosthetic or mechanical aortic valves, using both invasive and non-invasive measuring techniques. Measurements were carried out in 16 patients implanted with a St. Jude Medical aortic valve; two control groups comprised 10 patients with normal aortic valves after coronary artery bypass surgery, and five patients implanted with a Carpentier-Edwards pericardial aortic bioprosthesis. HFPF were measured intraoperatively using a hydrophone placed near the aortic annulus, and postoperatively using the same hydrophone mounted in a specially designed water-filled sound chamber. The frequency spectrum was evaluated using Fast Fourier transformation, and the root mean square (RMS) value of the pressure signals was calculated in the frequency range 50-150 kHz. HFPF with intensities significantly above the noise floor were registered using both methods in the vicinity of mechanical heart valves. The RMS values of the HFPF for all three patient groups measured intra- and postoperatively disclosed a significant difference between the mechanical valves and the two control groups, indicating that there is no cavitation in the vicinity of the biological or the native valves. HFPF are present in the vicinity of mechanical aortic valves and can be measured in patients, both invasively and non-invasively. This indication of cavitation was not observed in patients with either native or bioprosthetic aortic valves.


    • 1 January 2003
      • No. 109,p. 108-12

    Cavitation caused by mechanical heart valve prostheses--a review.

    by Peter Johansen, Brandon R Travis, Peter K Paulsen, Hans Nygaard, J Michael Hasenkam

    Heart valve dysfunction often necessitates surgical implantation of a mechanical heart valve (MHV). Although implantation of a MHV is a life-saving procedure, the patient still faces potentially complications such as thromboembolic events and material failure. These complications may be caused by cavitation, which can occur during valve closure. Cavitation is an erosive phenomenon that can be generated in fluids when the pressure locally drops below the vapor pressure. This paper reviews the literature on cavitation and MHVs and particular features of the valve and closing conditions that potentially increase the intensity of cavitation. Techniques for detecting cavitation will be discussed. Of these, an acoustic approach will be emphasized, since it is currently the only technique able to detect and quantify cavitation in vivo.