Antoine P. Simons
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antoine P. Simons has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Patrick W. Weerwind
Department of Cardiothoracic Surgery, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center (MUMC), Maastricht, Netherlands
5 shared publicationsJos G. Maessen
Department of Cardiothoracic Surgery and Cardiovascular Research Institute Maastricht Maastricht The Netherlands
4 shared publicationsFrederik H. Van Der Veen
Department of Cardiothoracic Surgery and Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
2 shared publications- Marcus Daniel Lancé
Department of Anesthesiology, Intensive Care and Perioperative Medicine, Hamad Medical Corporation (HMC), Doha, Qatar
2 shared publications - Patrick W. Weerwind
Department of Cardiothoracic Surgery and Cardiovascular Research Institute Maastricht Maastricht The Netherlands
2 shared publications Pieter Wortel
Department of Cardiothoracic Surgery and Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 24 April 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (2) , 391
A volume buffer capacity device dynamically reduces excessive venous line pressure and arterial gaseous embolic load during minimized cardiopulmonary bypass.
- 24 April 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (2) , 391
Open AccessA volume buffer capacity device dynamically reduces excessive venous line pressure and arterial gaseous embolic load during minimized cardiopulmonary bypass.
- 18 February 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (3) , 276-282
Hypovolemia in Extracorporeal Life Support Can Lead to Arterial Gaseous Microemboli
Next to severely decreased pump flow, hypovolemia in extracorporeal life support (ELS) can result in subatmospheric venous line pressure. Such pressure may lead to degassing and resultant gaseous microemboli (GME), with potential changes in neurological clinical outcome. CME activity resulting from degassing was investigated in relation to subatmospheric venous line pressure, partial oxygen pressure (pO2 ), and hematocrit in a model of a centrifugal pump-based circuit for long-term ELS. Additionally, a device that provides instantaneous volume buffer capacity during hypovolemia was evaluated in relation to GME appearance. An exponential relationship was found between decreasing venous line pressure and GME downstream of the centrifugal pump (P = 0.001). Arterial bubble activity appeared at subatmospheric venous line pressures of -200 mm Hg and less. A rising (pO2 ) increased formation of GME (P = 0.05). A rise in hematocrit, in contrast, did not affect embolic activity (P = 0.22). With simulated hypovolemia, volume buffer capacity added to the venous line dampened fluctuations of venous line pressure by approximately 40%, but a significant reduction in GME formation could not be found (P = 0.22). Moreover, the device enabled a 14% higher support flow. With ELS flow being related to patient volume status, hypovolemia can diminish support. A coherent decrease of venous line pressure triggers degassing of blood-dissolved gases and causes arterial GME, which can become massive during persistent conditions of limited venous return. Incorporation of a volume buffer capacity device into the extracorporeal support circuit enables a higher and more stable support flow in critically low patient filling.
- 18 February 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (3) , 276-282
Hypovolemia in Extracorporeal Life Support Can Lead to Arterial Gaseous Microemboli
Next to severely decreased pump flow, hypovolemia in extracorporeal life support (ELS) can result in subatmospheric venous line pressure. Such pressure may lead to degassing and resultant gaseous microemboli (GME), with potential changes in neurological clinical outcome. CME activity resulting from degassing was investigated in relation to subatmospheric venous line pressure, partial oxygen pressure (pO2 ), and hematocrit in a model of a centrifugal pump-based circuit for long-term ELS. Additionally, a device that provides instantaneous volume buffer capacity during hypovolemia was evaluated in relation to GME appearance. An exponential relationship was found between decreasing venous line pressure and GME downstream of the centrifugal pump (P = 0.001). Arterial bubble activity appeared at subatmospheric venous line pressures of -200 mm Hg and less. A rising (pO2 ) increased formation of GME (P = 0.05). A rise in hematocrit, in contrast, did not affect embolic activity (P = 0.22). With simulated hypovolemia, volume buffer capacity added to the venous line dampened fluctuations of venous line pressure by approximately 40%, but a significant reduction in GME formation could not be found (P = 0.22). Moreover, the device enabled a 14% higher support flow. With ELS flow being related to patient volume status, hypovolemia can diminish support. A coherent decrease of venous line pressure triggers degassing of blood-dissolved gases and causes arterial GME, which can become massive during persistent conditions of limited venous return. Incorporation of a volume buffer capacity device into the extracorporeal support circuit enables a higher and more stable support flow in critically low patient filling.
- 14 February 2013
- Published by Springer Nature in Intensive Care Medicine
- Vol. 39 (5) , 984-985
Optimized safety and function of the bicaval dual-lumen cannula by refined positioning and bedside management
- 14 February 2013
- Published by Springer Nature in Intensive Care Medicine
- Vol. 39 (5) , 984-985
Optimized safety and function of the bicaval dual-lumen cannula by refined positioning and bedside management
- Open Access
- 1 June 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 39 (6) , 1084-1085
Re: How to perform a haemodialysis using the arterial and venous lines of an extracorporeal life support
- 1 June 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 39 (6) , 1084-1085
Open AccessRe: How to perform a haemodialysis using the arterial and venous lines of an extracorporeal life support
- 20 May 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (5) , 554
Microbubble Formation During Minimized Cardiopulmonary Bypass
- 20 May 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (5) , 554
Microbubble Formation During Minimized Cardiopulmonary Bypass
- Open Access
- 27 April 2010
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 5 (1) , 30
Quantitative assessment of cardiac load-responsiveness during extracorporeal life support: case and rationale
We describe a case of a patient assisted by extracorporeal life support, in which we obtained the dynamic filling index, a measure for venous volume during extracorporeal life support, and used this index to assess cardiac load-responsiveness during acute reloading. While reloading, the obtained findings on cardiac pump function by the dynamic filling index were supported by trans-esophageal echocardiography and standard pressure measurement. This suggests that the dynamic filling index can be used to assess cardiac load-responsiveness during extracorporeal life support.
- 27 April 2010
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 5 (1) , 30
Open AccessQuantitative assessment of cardiac load-responsiveness during extracorporeal life support: case and rationale
We describe a case of a patient assisted by extracorporeal life support, in which we obtained the dynamic filling index, a measure for venous volume during extracorporeal life support, and used this index to assess cardiac load-responsiveness during acute reloading. While reloading, the obtained findings on cardiac pump function by the dynamic filling index were supported by trans-esophageal echocardiography and standard pressure measurement. This suggests that the dynamic filling index can be used to assess cardiac load-responsiveness during extracorporeal life support.
- 13 April 2010
- Published by Wiley in Artificial Organs
- Vol. 34 (4) , 289-294
Pulse Conductance and Flow‐induced Hemolysis During Pulsatile Cardiopulmonary Bypass
In this study, the hypothesis was tested that a low-resistant, high-compliant oxygenator provides better pulse conductance and less hemolysis than a high-resistant, low-compliant oxygenator during pulsatile cardiopulmonary bypass. Forty adults undergoing coronary artery bypass surgery were randomly divided into two groups using either an oxygenator with a relatively low hydraulic resistance (Quadrox BE-HMO 2000, Maquet Cardiopulmonary AG, Hirrlingen, Germany) or with a relatively high hydraulic resistance (Capiox SX18, Terumo Cardiovascular Systems, Tokyo, Japan). The phase shift between the flow signals measured at the inlet and outlet of the oxygenator was used to assess compliance. Pulse conductance in terms of pressure attenuation was calculated by dividing the outlet pulse pressure of the oxygenator by the inlet pulse pressure. A normalized index was used to assess hemolysis. The phase shifts in time of the flow pulses were 36 +/- 6 ms in the low-resistant (high-compliant) oxygenator, and 14 +/- 2 ms in the high-resistant (low-compliant) oxygenator group (P < 0.001). The low-resistant, high-compliant oxygenator provided 27% better pulse conductance compared with the high-resistant, low-compliant oxygenator (0.84 +/- 0.02 and 0.66 +/- 0.01, respectively, P < 0.001). Inlet pulse pressures were significantly higher (29%) in the high-resistant, low-compliant (Capiox) group than in the low-resistant, high-compliant (Quadrox) group (838 +/- 38 mm Hg and 648 +/- 25 mm Hg respectively, P < 0.001), but no significant difference in hemolysis was found. A low-resistant, high-compliant oxygenator provides better pulse conduction than a high-resistant, low-compliant oxygenator. However, the study data could not confirm the association of high pressures with increased hemolysis.
- 13 April 2010
- Published by Wiley in Artificial Organs
- Vol. 34 (4) , 289-294
Pulse Conductance and Flow‐induced Hemolysis During Pulsatile Cardiopulmonary Bypass
In this study, the hypothesis was tested that a low-resistant, high-compliant oxygenator provides better pulse conductance and less hemolysis than a high-resistant, low-compliant oxygenator during pulsatile cardiopulmonary bypass. Forty adults undergoing coronary artery bypass surgery were randomly divided into two groups using either an oxygenator with a relatively low hydraulic resistance (Quadrox BE-HMO 2000, Maquet Cardiopulmonary AG, Hirrlingen, Germany) or with a relatively high hydraulic resistance (Capiox SX18, Terumo Cardiovascular Systems, Tokyo, Japan). The phase shift between the flow signals measured at the inlet and outlet of the oxygenator was used to assess compliance. Pulse conductance in terms of pressure attenuation was calculated by dividing the outlet pulse pressure of the oxygenator by the inlet pulse pressure. A normalized index was used to assess hemolysis. The phase shifts in time of the flow pulses were 36 +/- 6 ms in the low-resistant (high-compliant) oxygenator, and 14 +/- 2 ms in the high-resistant (low-compliant) oxygenator group (P < 0.001). The low-resistant, high-compliant oxygenator provided 27% better pulse conductance compared with the high-resistant, low-compliant oxygenator (0.84 +/- 0.02 and 0.66 +/- 0.01, respectively, P < 0.001). Inlet pulse pressures were significantly higher (29%) in the high-resistant, low-compliant (Capiox) group than in the low-resistant, high-compliant (Quadrox) group (838 +/- 38 mm Hg and 648 +/- 25 mm Hg respectively, P < 0.001), but no significant difference in hemolysis was found. A low-resistant, high-compliant oxygenator provides better pulse conduction than a high-resistant, low-compliant oxygenator. However, the study data could not confirm the association of high pressures with increased hemolysis.
- Open Access
- 1 August 2009
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 36 (2) , 330-334
Dynamic filling index: a novel parameter to monitor circulatory filling during minimized extracorporeal bypass
Objective: To evaluate the dynamic filling index, a novel parameter to monitor changes in venous return and drainable volume, in circulatory assisted patients. Minimized extracorporeal bypass systems lack volume buffering capacity, demanding tight control of drainable volume to maintain bypass flow. Therefore, with patients on minimized bypass quantitative assessment of venous drainable volume is crucial. Methods: In seven patients undergoing coronary artery bypass grafting using minimized extracorporeal bypass we utilized luxation of the heart to induce a reduction in venous return. The speed of the centrifugal pump was transiently and periodically reduced to monitor resultant changes in bypass flow. The dynamic filling index, a measure of drainable volume, was calculated as Δflow/Δspeed. Results: With luxation, the dynamic filling index was significantly reduced (from 2.4 ± 0.2 to 2.0 ± 0.2 ml/rotation, p = 0.001; 95% confidence interval of mean difference: 0.23–0.46 ml/rotation), whereas routinely recorded parameters, like bypass flow, pump inlet and arterial line pressure, did not change significantly. The intra-measurement reproducibility for the dynamic filling index was 0.5 ml/rotation (20% of the mean), suggesting good potential for this parameter to monitor on-pump venous return in patients. Conclusion: The dynamic filling index can detect small changes in venous return and drainable volume which remain unrevealed by routinely recorded parameters. This index could be a valuable tool to monitor and control circulatory filling in individual patients supported by minimized extracorporeal bypass.
- 1 August 2009
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 36 (2) , 330-334
Open AccessDynamic filling index: a novel parameter to monitor circulatory filling during minimized extracorporeal bypass
Objective: To evaluate the dynamic filling index, a novel parameter to monitor changes in venous return and drainable volume, in circulatory assisted patients. Minimized extracorporeal bypass systems lack volume buffering capacity, demanding tight control of drainable volume to maintain bypass flow. Therefore, with patients on minimized bypass quantitative assessment of venous drainable volume is crucial. Methods: In seven patients undergoing coronary artery bypass grafting using minimized extracorporeal bypass we utilized luxation of the heart to induce a reduction in venous return. The speed of the centrifugal pump was transiently and periodically reduced to monitor resultant changes in bypass flow. The dynamic filling index, a measure of drainable volume, was calculated as Δflow/Δspeed. Results: With luxation, the dynamic filling index was significantly reduced (from 2.4 ± 0.2 to 2.0 ± 0.2 ml/rotation, p = 0.001; 95% confidence interval of mean difference: 0.23–0.46 ml/rotation), whereas routinely recorded parameters, like bypass flow, pump inlet and arterial line pressure, did not change significantly. The intra-measurement reproducibility for the dynamic filling index was 0.5 ml/rotation (20% of the mean), suggesting good potential for this parameter to monitor on-pump venous return in patients. Conclusion: The dynamic filling index can detect small changes in venous return and drainable volume which remain unrevealed by routinely recorded parameters. This index could be a valuable tool to monitor and control circulatory filling in individual patients supported by minimized extracorporeal bypass.
- 1 December 2008
- Published by Wiley in Artificial Organs
- Vol. 32 (12) , 1000-1001
Letter to the Editor
- 8 July 2008
- Published by Wiley in Artificial Organs
- Vol. 32 (7) , 566-571
Laboratory Performance Testing of Venous Cannulae During Inlet Obstruction
Abstract: Venous cannulae undergo continuous improvements to achieve better and safer venous drainage. Several cannula tests have been reported, though cannula performance during inlet obstruction has never been a test criterion. In this study, five different cannulae for proximal venous drainage were tested in a mock circulation that enabled measurement of hydraulic conductance after inlet obstruction by vessel collapse. Values for hydraulic conductance ranged from 1.11 × 10–2 L/min/mm Hg for a Thin‐Flex Single Stage Venous Cannula with an open‐end lighthouse tip to 1.55 × 10–2 L/min/mm Hg for a DLP VAD Venous Cannula featuring a swirled tip profile, showing a difference that amounts to nearly 40% of the lowest conductance value. Excessive venous drainage results in potentially dangerous high‐negative venous line pressures independent of cannula design. Cannulatip design featuring swirled and grooved tip structures increases drainage capacity and enhances cannula performance during inlet obstruction.
- 8 July 2008
- Published by Wiley in Artificial Organs
- Vol. 32 (7) , 566-571
Laboratory Performance Testing of Venous Cannulae During Inlet Obstruction
Abstract: Venous cannulae undergo continuous improvements to achieve better and safer venous drainage. Several cannula tests have been reported, though cannula performance during inlet obstruction has never been a test criterion. In this study, five different cannulae for proximal venous drainage were tested in a mock circulation that enabled measurement of hydraulic conductance after inlet obstruction by vessel collapse. Values for hydraulic conductance ranged from 1.11 × 10–2 L/min/mm Hg for a Thin‐Flex Single Stage Venous Cannula with an open‐end lighthouse tip to 1.55 × 10–2 L/min/mm Hg for a DLP VAD Venous Cannula featuring a swirled tip profile, showing a difference that amounts to nearly 40% of the lowest conductance value. Excessive venous drainage results in potentially dangerous high‐negative venous line pressures independent of cannula design. Cannulatip design featuring swirled and grooved tip structures increases drainage capacity and enhances cannula performance during inlet obstruction.