Günther Zick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Günther Zick has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Inéz Frerichs
University Hospital Schleswig-Holstein
4 shared publications - Norbert Weiler
Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
4 shared publications - Dirk Schädler
University Hospital Schleswig-Holstein
3 shared publications - Gunnar Elke
Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Arnold-Heller-Strasse 3 Haus 12, D-24105 Kiel, Germany
3 shared publications - Jens Scholz
University Medical Center Schleswig-Holstein, 24105 Kiel, Germany
2 shared publications - Sven Pulletz
Department of Anaesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein, Campus Kiel, Kiel, Germany
2 shared publications
Latest Publications
- Open Access
- 7 January 2011
- Published by Springer Nature in Critical Care
- Vol. 15 (1) , R8
A new technique for bedside placement of enteral feeding tubes: a prospective cohort study
Introduction: To accomplish early enteral feeding in the critically ill patient a new transnasal endoscopic approach to the placement of postpyloric feeding tubes by intensive care physicians was evaluated. Methods: This was a prospective cohort study in 27 critically ill patients subjected to transnasal endoscopy and intubation of the pylorus. Attending intensive care physicians were trained in the handling of the new endoscope for transnasal gastroenteroscopy for two days. A jejunal feeding tube was advanced via the instrument channel and the correct position assessed by contrast radiography. The primary outcome measure was successful postpyloric placement of the tube. Secondary outcome measures were time needed for the placement, complications such as bleeding and formation of loops, and the score of the placement difficulty graded from 1 (easy) to 4 (difficult). Data are given as mean values and standard deviation. Results: Out of 34 attempted jejunal tube placements, 28 tubes (82%) were placed correctly in the jejunum. The duration of the procedure was 28 ± 12 minutes. The difficulty of the tube placement was judged as follows: grade 1: 17 patients, grade 2: 8 patients, grade 3: 7 patients, grade 4: 2 patients. In three cases, the tube position was incorrect, and in another three cases, the procedure had to be aborted. In one patient bleeding occurred that required no further treatment. Conclusions: Fast and reliable transnasal insertion of postpyloric feeding tubes can be accomplished by trained intensive care physicians at the bedside using the presented procedure. This new technique may facilitate early initiation of enteral feeding in intensive care patients.
- 7 January 2011
- Published by Springer Nature in Critical Care
- Vol. 15 (1) , R8
Open AccessA new technique for bedside placement of enteral feeding tubes: a prospective cohort study
Introduction: To accomplish early enteral feeding in the critically ill patient a new transnasal endoscopic approach to the placement of postpyloric feeding tubes by intensive care physicians was evaluated. Methods: This was a prospective cohort study in 27 critically ill patients subjected to transnasal endoscopy and intubation of the pylorus. Attending intensive care physicians were trained in the handling of the new endoscope for transnasal gastroenteroscopy for two days. A jejunal feeding tube was advanced via the instrument channel and the correct position assessed by contrast radiography. The primary outcome measure was successful postpyloric placement of the tube. Secondary outcome measures were time needed for the placement, complications such as bleeding and formation of loops, and the score of the placement difficulty graded from 1 (easy) to 4 (difficult). Data are given as mean values and standard deviation. Results: Out of 34 attempted jejunal tube placements, 28 tubes (82%) were placed correctly in the jejunum. The duration of the procedure was 28 ± 12 minutes. The difficulty of the tube placement was judged as follows: grade 1: 17 patients, grade 2: 8 patients, grade 3: 7 patients, grade 4: 2 patients. In three cases, the tube position was incorrect, and in another three cases, the procedure had to be aborted. In one patient bleeding occurred that required no further treatment. Conclusions: Fast and reliable transnasal insertion of postpyloric feeding tubes can be accomplished by trained intensive care physicians at the bedside using the presented procedure. This new technique may facilitate early initiation of enteral feeding in intensive care patients.
- Open Access
- 29 November 2010
- Published by Bentham Science Publishers Ltd. in The Open Nuclear Medicine Journal
- Vol. 2 (1) , 110-118
Electrical Impedance Tomography in Acute Respiratory Distress Syndrome
- 29 November 2010
- Published by Bentham Science Publishers Ltd. in The Open Nuclear Medicine Journal
- Vol. 2 (1) , 110-118
Open AccessElectrical Impedance Tomography in Acute Respiratory Distress Syndrome
- Open Access
- 11 February 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (1) , R17
Effects of interventional lung assist on haemodynamics and gas exchange in cardiopulmonary resuscitation: a prospective experimental study on animals with acute respiratory distress syndrome
Introduction: Interventional lung assist (ILA), based on the use of a pumpless extracorporeal membrane oxygenator, facilitates carbon dioxide (CO2) elimination in acute respiratory distress syndrome (ARDS). It is unclear whether an ILA system should be clamped during cardiopulmonary resuscitation (CPR) in patients with ARDS or not. The aim of our study was to test the effects of an ILA on haemodynamics and gas exchange during CPR on animals with ARDS and to establish whether the ILA should be kept open or clamped under these circumstances. Methods: The study was designed to be prospective and experimental. The experiments were performed on 12 anaesthetised and mechanically ventilated pigs (weighing 41 to 58 kg). One femoral artery and one femoral vein were cannulated and connected to an ILA. ARDS was induced by repeated bronchoalveolar lavage. An indwelling pacemaker was used to initiate ventricular fibrillation and chest compressions were immediately started and continued for 30 minutes. In six animals, the ILA was kept open and in the other six it was clamped. Results: Systolic and mean arterial pressures did not differ significantly between the groups. With the ILA open mean ± standard deviation systolic blood pressures were 89 ± 26 mmHg at 5 minutes, 71 ± 28 mmHg at 10 minutes, 63 ± 33 mmHg at 20 minutes and 83 ± 23 mmHg at 30 minutes. The clamped ILA system resulted in systolic pressures of 77 ± 30 mmHg, 90 ± 23 mmHg, 72 ± 11 mmHg and 72 ± 22 mmHg, respectively. In the group with the ILA system open, arterial partial pressure of CO2 was significantly lower after 10, 20 and 30 minutes of CPR and arterial partial pressure of oxygen was higher 20 minutes after the onset of CPR (191 ± 140 mmHg versus 57 ± 14 mmHg). End-tidal partial pressure of CO2 decreased from 46 ± 23 Torr (ILA open) and 37 ± 9 Torr (ILA clamped) before intervention to 8 ± 5 Torr and 8 ± 10 Torr, respectively, in both groups after 30 minutes of CPR. Conclusions: Our results indicate that in an animal model of ARDS, blood pressures were not impaired by keeping the ILA system open during CPR compared with the immediate clamping of the ILA with the onset of CPR. The effect of ILA on gas exchange implied a beneficial effect.
- 11 February 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (1) , R17
Open AccessEffects of interventional lung assist on haemodynamics and gas exchange in cardiopulmonary resuscitation: a prospective experimental study on animals with acute respiratory distress syndrome
Introduction: Interventional lung assist (ILA), based on the use of a pumpless extracorporeal membrane oxygenator, facilitates carbon dioxide (CO2) elimination in acute respiratory distress syndrome (ARDS). It is unclear whether an ILA system should be clamped during cardiopulmonary resuscitation (CPR) in patients with ARDS or not. The aim of our study was to test the effects of an ILA on haemodynamics and gas exchange during CPR on animals with ARDS and to establish whether the ILA should be kept open or clamped under these circumstances. Methods: The study was designed to be prospective and experimental. The experiments were performed on 12 anaesthetised and mechanically ventilated pigs (weighing 41 to 58 kg). One femoral artery and one femoral vein were cannulated and connected to an ILA. ARDS was induced by repeated bronchoalveolar lavage. An indwelling pacemaker was used to initiate ventricular fibrillation and chest compressions were immediately started and continued for 30 minutes. In six animals, the ILA was kept open and in the other six it was clamped. Results: Systolic and mean arterial pressures did not differ significantly between the groups. With the ILA open mean ± standard deviation systolic blood pressures were 89 ± 26 mmHg at 5 minutes, 71 ± 28 mmHg at 10 minutes, 63 ± 33 mmHg at 20 minutes and 83 ± 23 mmHg at 30 minutes. The clamped ILA system resulted in systolic pressures of 77 ± 30 mmHg, 90 ± 23 mmHg, 72 ± 11 mmHg and 72 ± 22 mmHg, respectively. In the group with the ILA system open, arterial partial pressure of CO2 was significantly lower after 10, 20 and 30 minutes of CPR and arterial partial pressure of oxygen was higher 20 minutes after the onset of CPR (191 ± 140 mmHg versus 57 ± 14 mmHg). End-tidal partial pressure of CO2 decreased from 46 ± 23 Torr (ILA open) and 37 ± 9 Torr (ILA clamped) before intervention to 8 ± 5 Torr and 8 ± 10 Torr, respectively, in both groups after 30 minutes of CPR. Conclusions: Our results indicate that in an animal model of ARDS, blood pressures were not impaired by keeping the ILA system open during CPR compared with the immediate clamping of the ILA with the onset of CPR. The effect of ILA on gas exchange implied a beneficial effect.
- Open Access
- 7 April 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (2) , R56
Oxygenation effect of interventional lung assist in a lavage model of acute lung injury: a prospective experimental study
Introduction: The aim of the study was to test the hypothesis that a pumpless arteriovenous extracorporeal membrane oxygenator (interventional lung assist (ILA)) does not significantly improve oxygenation in a lavage model of acute lung injury. Methods: The study was designed as a prospective experimental study. The experiments were performed on seven pigs (48–60 kg body weight). The pigs were anesthetized and mechanically ventilated. Both femoral arteries and one femoral vein were cannulated and connected with ILA. Acute lung injury was induced by repeated bronchoalveolar lavage until the arterial partial pressure of O2 was lower than 100 Torr for at least 30 minutes during ventilation with 100% O2. Results: ILA was applied with different blood flow rates through either one or both femoral arteries. Measurements were repeated at different degrees of pulmonary gas exchange impairment with the pulmonary venous admixture ranging from 35.0% to 70.6%. The mean (± standard deviation) blood flow through ILA was 15.5 (± 3.9)% and 21.7 (± 4.9)% of cardiac output with one and both arteries open, respectively. ILA significantly increased the arterial partial pressure of O2 from 64 (± 13) Torr to 71 (± 14) Torr and 74 (± 17) Torr with blood flow through one and both femoral arteries, respectively. O2 delivery through ILA increased with extracorporeal shunt flow (36 (± 14) ml O2/min versus 47 (± 17) ml O2/min) and reduced arterialization of the inlet blood. Pulmonary artery pressures were significantly reduced when ILA was in operation. Conclusion: Oxygenation is increased by ILA in severe lung injury. This effect is significant but small. The results indicate that the ILA use may not be justified if the improvement of oxygenation is the primary therapy goal.
- 7 April 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (2) , R56
Open AccessOxygenation effect of interventional lung assist in a lavage model of acute lung injury: a prospective experimental study
Introduction: The aim of the study was to test the hypothesis that a pumpless arteriovenous extracorporeal membrane oxygenator (interventional lung assist (ILA)) does not significantly improve oxygenation in a lavage model of acute lung injury. Methods: The study was designed as a prospective experimental study. The experiments were performed on seven pigs (48–60 kg body weight). The pigs were anesthetized and mechanically ventilated. Both femoral arteries and one femoral vein were cannulated and connected with ILA. Acute lung injury was induced by repeated bronchoalveolar lavage until the arterial partial pressure of O2 was lower than 100 Torr for at least 30 minutes during ventilation with 100% O2. Results: ILA was applied with different blood flow rates through either one or both femoral arteries. Measurements were repeated at different degrees of pulmonary gas exchange impairment with the pulmonary venous admixture ranging from 35.0% to 70.6%. The mean (± standard deviation) blood flow through ILA was 15.5 (± 3.9)% and 21.7 (± 4.9)% of cardiac output with one and both arteries open, respectively. ILA significantly increased the arterial partial pressure of O2 from 64 (± 13) Torr to 71 (± 14) Torr and 74 (± 17) Torr with blood flow through one and both femoral arteries, respectively. O2 delivery through ILA increased with extracorporeal shunt flow (36 (± 14) ml O2/min versus 47 (± 17) ml O2/min) and reduced arterialization of the inlet blood. Pulmonary artery pressures were significantly reduced when ILA was in operation. Conclusion: Oxygenation is increased by ILA in severe lung injury. This effect is significant but small. The results indicate that the ILA use may not be justified if the improvement of oxygenation is the primary therapy goal.