Christoph Haberthür
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christoph Haberthür has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Annekathrin Mehlig
Kantonsspital Liestal, Department of Internal Medicine, Rheinstrasse 26, Liestal, 4410, Switzerland
1 shared publication Christine Stebler Gysi
Blutspendedienst SRK beider Basel, Basel, Switzerland
1 shared publication- Giovanna Brandi
Institute for Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
1 shared publication - Hans-Joachim Priebe
Department of Anesthesia and Critical Care Medicine, University Hospital Freiburg Hugstetter Street 55, 79106 Freiburg Germany
1 shared publication - Hartmut Schächinger
Department of Clinical Psychophysiology, Institute of Psychobiology, University of Trier, Trier, Germany
1 shared publication - John F. Stover
Surgical Intensive Care Medicine, University Hospital Zuerich, Raemistrasse 100, CH 8091 Zuerich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 8 February 2010
- Published by Springer Nature in Critical Care
- Vol. 14 (1) , R13
Brain metabolism is significantly impaired at blood glucose below 6 mM and brain glucose below 1 mM in patients with severe traumatic brain injury
Introduction: The optimal blood glucose target following severe traumatic brain injury (TBI) must be defined. Cerebral microdialysis was used to investigate the influence of arterial blood and brain glucose on cerebral glucose, lactate, pyruvate, glutamate, and calculated indices of downstream metabolism. Methods: In twenty TBI patients, microdialysis catheters inserted in the edematous frontal lobe were dialyzed at 1 μl/min, collecting samples at 60 minute intervals. Occult metabolic alterations were determined by calculating the lactate- pyruvate (L/P), lactate- glucose (L/Glc), and lactate- glutamate (L/Glu) ratios. Results: Brain glucose was influenced by arterial blood glucose. Elevated L/P and L/Glc were significantly reduced at brain glucose above 1 mM, reaching lowest values at blood and brain glucose levels between 6-9 mM (P < 0.001). Lowest cerebral glutamate was measured at brain glucose 3-5 mM with a significant increase at brain glucose below 3 mM and above 6 mM. While L/Glu was significantly increased at low brain glucose levels, it was significantly decreased at brain glucose above 5 mM (P < 0.001). Insulin administration increased brain glutamate at low brain glucose, but prevented increase in L/Glu. Conclusions: Arterial blood glucose levels appear to be optimal at 6-9 mM. While low brain glucose levels below 1 mM are detrimental, elevated brain glucose are to be targeted despite increased brain glutamate at brain glucose >5 mM. Pathogenity of elevated glutamate appears to be relativized by L/Glu and suggests to exclude insulin- induced brain injury.
- 8 February 2010
- Published by Springer Nature in Critical Care
- Vol. 14 (1) , R13
Open AccessBrain metabolism is significantly impaired at blood glucose below 6 mM and brain glucose below 1 mM in patients with severe traumatic brain injury
Introduction: The optimal blood glucose target following severe traumatic brain injury (TBI) must be defined. Cerebral microdialysis was used to investigate the influence of arterial blood and brain glucose on cerebral glucose, lactate, pyruvate, glutamate, and calculated indices of downstream metabolism. Methods: In twenty TBI patients, microdialysis catheters inserted in the edematous frontal lobe were dialyzed at 1 μl/min, collecting samples at 60 minute intervals. Occult metabolic alterations were determined by calculating the lactate- pyruvate (L/P), lactate- glucose (L/Glc), and lactate- glutamate (L/Glu) ratios. Results: Brain glucose was influenced by arterial blood glucose. Elevated L/P and L/Glc were significantly reduced at brain glucose above 1 mM, reaching lowest values at blood and brain glucose levels between 6-9 mM (P < 0.001). Lowest cerebral glutamate was measured at brain glucose 3-5 mM with a significant increase at brain glucose below 3 mM and above 6 mM. While L/Glu was significantly increased at low brain glucose levels, it was significantly decreased at brain glucose above 5 mM (P < 0.001). Insulin administration increased brain glutamate at low brain glucose, but prevented increase in L/Glu. Conclusions: Arterial blood glucose levels appear to be optimal at 6-9 mM. While low brain glucose levels below 1 mM are detrimental, elevated brain glucose are to be targeted despite increased brain glutamate at brain glucose >5 mM. Pathogenity of elevated glutamate appears to be relativized by L/Glu and suggests to exclude insulin- induced brain injury.
- Open Access
- 23 January 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (1) , R4
Expiratory automatic endotracheal tube compensation reduces dynamic hyperinflation in a physical lung model
Introduction: The effect of expiratory endotracheal tube (ETT) resistance on dynamic lung inflation is unknown. We hypothesized that ETT resistance causes dynamic lung hyperinflation by impeding lung emptying. We further hypothesized that compensation for expiratory ETT resistance by automatic tube compensation (ATC) attenuates dynamic lung hyperinflation. Methods: A ventilator equipped with the original ATC mode and operating in a pressure-targeted mode was connected to a physical lung model that consists of four equally sized glass bottles filled with copper wool. Inspiratory pressure, peak expiratory flow, trapped lung volume and intrinsic positive end-expiratory pressure (PEEP) were assessed at combinations of four inner ETT diameters (7.0, 7.5, 8.0 and 8.5 mm), four respiratory rates (15, 20, 25 and 30/minute), three inspiratory pressures (3.0, 4.5 and 6.0 cmH2O) and four lung compliances (113, 86, 58 and 28 ml/cmH2O). Intrinsic PEEP was measured at the end of an expiratory hold manoeuvre. Results: At a given test lung compliance, inspiratory pressure and ETT size, increasing respiratory rates from 15 to 30/minutes had the following effects: inspiratory tidal volume and peak expiratory flow were decreased by means of 25% (range 0% to 51%) and 11% (8% to 12%), respectively; and trapped lung volume and intrinsic PEEP were increased by means of 25% (0% to 51%) and 26% (5% to 45%), respectively (all P < 0.025). At otherwise identical baseline conditions, introduction of expiratory ATC significantly attenuated (P < 0.025), by approximately 50%, the respiratory rate-dependent decreases in inspiratory tidal volume and the increases in trapped lung volume and intrinsic PEEP. Conclusions: In a lung model of pressure-targeted ventilation, expiratory ETT resistance caused dynamic lung hyperinflation during increases in respiratory rates, thereby reducing inspiratory tidal volume. Expiratory ATC attenuated these adverse effects.
- 23 January 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (1) , R4
Open AccessExpiratory automatic endotracheal tube compensation reduces dynamic hyperinflation in a physical lung model
Introduction: The effect of expiratory endotracheal tube (ETT) resistance on dynamic lung inflation is unknown. We hypothesized that ETT resistance causes dynamic lung hyperinflation by impeding lung emptying. We further hypothesized that compensation for expiratory ETT resistance by automatic tube compensation (ATC) attenuates dynamic lung hyperinflation. Methods: A ventilator equipped with the original ATC mode and operating in a pressure-targeted mode was connected to a physical lung model that consists of four equally sized glass bottles filled with copper wool. Inspiratory pressure, peak expiratory flow, trapped lung volume and intrinsic positive end-expiratory pressure (PEEP) were assessed at combinations of four inner ETT diameters (7.0, 7.5, 8.0 and 8.5 mm), four respiratory rates (15, 20, 25 and 30/minute), three inspiratory pressures (3.0, 4.5 and 6.0 cmH2O) and four lung compliances (113, 86, 58 and 28 ml/cmH2O). Intrinsic PEEP was measured at the end of an expiratory hold manoeuvre. Results: At a given test lung compliance, inspiratory pressure and ETT size, increasing respiratory rates from 15 to 30/minutes had the following effects: inspiratory tidal volume and peak expiratory flow were decreased by means of 25% (range 0% to 51%) and 11% (8% to 12%), respectively; and trapped lung volume and intrinsic PEEP were increased by means of 25% (0% to 51%) and 26% (5% to 45%), respectively (all P < 0.025). At otherwise identical baseline conditions, introduction of expiratory ATC significantly attenuated (P < 0.025), by approximately 50%, the respiratory rate-dependent decreases in inspiratory tidal volume and the increases in trapped lung volume and intrinsic PEEP. Conclusions: In a lung model of pressure-targeted ventilation, expiratory ETT resistance caused dynamic lung hyperinflation during increases in respiratory rates, thereby reducing inspiratory tidal volume. Expiratory ATC attenuated these adverse effects.
- 1 February 2006
- Published by Springer Nature in European Journal of Trauma
- Vol. 32 (1) , 28-36
New Aspects in Mechanical Ventilation
- 1 February 2006
- Published by Springer Nature in European Journal of Trauma
- Vol. 32 (1) , 28-36
New Aspects in Mechanical Ventilation
- Open Access
- 9 June 2005
- Published by Springer Nature in Critical Care
- Vol. 9 (4) , R407-15
Short-term effects of positive end-expiratory pressure on breathing pattern: an interventional study in adult intensive care patients
Introduction: Positive end-expiratory pressure (PEEP) is used in mechanically ventilated patients to increase pulmonary volume and improve gas exchange. However, in clinical practice and with respect to adult, ventilator-dependent patients, little is known about the short-term effects of PEEP on breathing patterns. Methods: In 30 tracheally intubated, spontaneously breathing patients, we sequentially applied PEEP to the trachea at 0, 5 and 10 cmH2O, and then again at 5 cmH2O for 30 s each, using the automatic tube compensation mode. Results: Increases in PEEP were strongly associated with drops in minute ventilation (P < 0.0001) and respiratory rate (P < 0.0001). For respiratory rate, a 1 cmH2O change in PEEP in either direction resulted in a change in rate of 0.4 breaths/min. The effects were exclusively due to changes in expiratory time. Effects began to manifest during the first breath and became fully established in the second breath for each PEEP level. Identical responses were found when PEEP levels were applied for 10 or 60 s. Post hoc analysis revealed a similar but stronger response in patients with impaired respiratory system compliance. Conclusion: In tracheally intubated, spontaneously breathing adult patients, the level of PEEP significantly influences the resting short-term breathing pattern by selectively affecting expiratory time. These findings are best explained by the Hering–Breuer inflation/deflation reflex.
- 9 June 2005
- Published by Springer Nature in Critical Care
- Vol. 9 (4) , R407-15
Open AccessShort-term effects of positive end-expiratory pressure on breathing pattern: an interventional study in adult intensive care patients
Introduction: Positive end-expiratory pressure (PEEP) is used in mechanically ventilated patients to increase pulmonary volume and improve gas exchange. However, in clinical practice and with respect to adult, ventilator-dependent patients, little is known about the short-term effects of PEEP on breathing patterns. Methods: In 30 tracheally intubated, spontaneously breathing patients, we sequentially applied PEEP to the trachea at 0, 5 and 10 cmH2O, and then again at 5 cmH2O for 30 s each, using the automatic tube compensation mode. Results: Increases in PEEP were strongly associated with drops in minute ventilation (P < 0.0001) and respiratory rate (P < 0.0001). For respiratory rate, a 1 cmH2O change in PEEP in either direction resulted in a change in rate of 0.4 breaths/min. The effects were exclusively due to changes in expiratory time. Effects began to manifest during the first breath and became fully established in the second breath for each PEEP level. Identical responses were found when PEEP levels were applied for 10 or 60 s. Post hoc analysis revealed a similar but stronger response in patients with impaired respiratory system compliance. Conclusion: In tracheally intubated, spontaneously breathing adult patients, the level of PEEP significantly influences the resting short-term breathing pattern by selectively affecting expiratory time. These findings are best explained by the Hering–Breuer inflation/deflation reflex.
- 1 December 2003
- Published by SAGE Publications in Technology and Health Care
- Vol. 11 (6) , 413-424
Continuous monitoring of tracheal pressure including spot-check of endotracheal tube resistance
During mechanical ventilation, the resistance of the endotracheal and tracheostomy tube (ETT) highly influences analysis of respiratory system mechanics and imposes additional work of breathing for the spontaneously breathing patient which both can b
- 1 December 2003
- Published by SAGE Publications in Technology and Health Care
- Vol. 11 (6) , 413-424
Continuous monitoring of tracheal pressure including spot-check of endotracheal tube resistance
During mechanical ventilation, the resistance of the endotracheal and tracheostomy tube (ETT) highly influences analysis of respiratory system mechanics and imposes additional work of breathing for the spontaneously breathing patient which both can b
- 6 May 2003
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 23 (3) , 159-165
Effect of non-hypotensive haemorrhage on plasma catecholamine levels and cardiovascular variability in man*
- 6 May 2003
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 23 (3) , 159-165
Effect of non-hypotensive haemorrhage on plasma catecholamine levels and cardiovascular variability in man*