DPDaniel Prell

Daniel Prell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Prell has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT

    by D Prell, W A Kalender, Y Kyriakou

    The purpose of this study was to develop, implement and evaluate a dedicated metal artefact reduction (MAR) method for flat-detector CT (FDCT). The algorithm uses the multidimensional raw data space to calculate surrogate attenuation values for the original metal traces in the raw data domain. The metal traces are detected automatically by a three-dimensional, threshold-based segmentation algorithm in an initial reconstructed image volume, based on twofold histogram information for calculating appropriate metal thresholds. These thresholds are combined with constrained morphological operations in the projection domain. A subsequent reconstruction of the modified raw data yields an artefact-reduced image volume that is further processed by a combining procedure that reinserts the missing metal information. For image quality assessment, measurements on semi-anthropomorphic phantoms containing metallic inserts were evaluated in terms of CT value accuracy, image noise and spatial resolution before and after correction. Measurements of the same phantoms without prostheses were used as ground truth for comparison. Cadaver measurements were performed on complex and realistic cases and to determine the influences of our correction method on the tissue surrounding the prostheses. The results showed a significant reduction of metal-induced streak artefacts (CT value differences were reduced to below 22 HU and image noise reduction of up to 200%). The cadaver measurements showed excellent results for imaging areas close to the implant and exceptional artefact suppression in these areas. Furthermore, measurements in the knee and spine regions confirmed the superiority of our method to standard one-dimensional, linear interpolation.


  • Reducing Metal Artifacts in Computed Tomography Caused by Hip Endoprostheses Using a Physics-Based Approach

    by Daniel Prell, Yiannis Kyriakou, Marc Kachelrie, Willi A. Kalender

    Metal-induced artifacts may cause severe problems in clinical computed tomography (CT) imaging and may impair diagnosis as well as overall image quality. Many approaches for reducing these artifacts tackle the problem by simply ignoring or interpolating the metal traces in the raw data, which results in a general information loss and additional artifacts in the corrected image. It was the objective of this study to develop an approach aiming at correcting several physical artifact sources. We have also tried to minimize the impact on spatial resolution and attempted to avoid new artifacts resulting from the correction. The algorithm works with a first volumetric reconstruction followed by threshold-based metal prostheses segmentation. The segmented metal implants are then forward projected and the resulting sinogram entries are squared and combined, followed by a second reconstruction to yield correction volumes. The resulting volumes are then combined linearly with a combination weight determined to minimize the flatness of the initial image. A directional filtering algorithm following the beam hardening correction applies a nonlinear convolution in the metal traces of the sinogram which reduces existing metal-induced noise artifacts. Phantom measurements on a polyethylene (PE) disc with different inserts and a semi-anthropomorphic hip phantom with optional bone and titanium inserts were used for evaluating the algorithm. Patient datasets containing uni- and bilateral hip endoprostheses verified the applicability and efficiency on realistic clinical cases. Deviations in CT values were reduced to below 3 HU on average. Image noise reduction of up to 70% was achieved (average noise reduction of 37%) with a more homogeneous CT value distribution in soft-tissue areas. A comparison to standard interpolation methods showed superior artifact suppression without producing artifacts caused by interpolation and without the general information loss in the close vicinity to the implants. The impact on spatial resolution was minimized as compared with interpolation algorithms. Metal artifacts caused by hip-endoprostheses were strongly reduced. Soft tissue areas and skeletal structures surrounding the implants were well restored. The correction works by postprocessing CT datasets and it is applicable to any reconstructed image without a priori knowledge.


  • Open Access

    Metal Artifact Reduction for Clipping and Coiling in Interventional C-Arm CT

    by D. Prell, Y. Kyriakou, T. Struffert, A. Dörfler, W.A. Kalender

    BACKGROUND AND PURPOSE: Metallic implants induce massive artifacts in CT images which deteriorate image quality and often superimpose structures of interest. The purpose of this study was to apply and evaluate a dedicated MAR method for neuroradiologic intracranial clips and detachable platinum coiling events. We here report the first clinical results for MAR in FDCT. MATERIALS AND METHODS: FDCT volume scans of several patients treated with endovascular coiling or intracranial clipping were corrected by using a dedicated FDCT MAR correction algorithm combined with an edge-preserving attenuation-normalization method in the projection space. Corrected and uncorrected images were compared by 2 experienced radiologists and evaluated for several image-quality features. RESULTS: After application of our algorithm, implant delineation and visibility were highly improved. CT values compared with values in metal artifact−unaffected areas showed good agreement (average correction of 1300 HU). Image noise was reduced overall by 27%. Intracranial hemorrhage in the direct surroundings of the implanted coil or clip material was displayed without worrisome metal artifacts, and our algorithm even allowed diagnosis in areas where extensive information losses were seen. The high spatial resolution provided by FDCT imaging was well preserved. CONCLUSIONS: Our MAR method provided metal artifact−reduced images in every studied case. It reduced image noise and corrected CT values to levels comparable with images measured without metallic implants. An overall improvement of brain tissue modeling and implant visibility was achieved. MAR in neuroradiologic FDCT imaging is a promising step forward for better image quality and diagnosis in the presence of metallic implants.


  • A novel forward projection-based metal artifact reduction method for flat-detector computed tomography

    by Daniel Prell, Yiannis Kyriakou, Marcel Beister, Willi A Kalender

    Metallic implants generate streak-like artifacts in flat-detector computed tomography (FD-CT) reconstructed volumetric images. This study presents a novel method for reducing these disturbing artifacts by inserting discarded information into the original rawdata using a three-step correction procedure and working directly with each detector element. Computation times are minimized by completely implementing the correction process on graphics processing units (GPUs). First, the original volume is corrected using a three-dimensional interpolation scheme in the rawdata domain, followed by a second reconstruction. This metal artifact-reduced volume is then segmented into three materials, i.e. air, soft-tissue and bone, using a threshold-based algorithm. Subsequently, a forward projection of the obtained tissue-class model substitutes the missing or corrupted attenuation values directly for each flat detector element that contains attenuation values corresponding to metal parts, followed by a final reconstruction. Experiments using tissue-equivalent phantoms showed a significant reduction of metal artifacts (deviations of CT values after correction compared to measurements without metallic inserts reduced typically to below 20 HU, differences in image noise to below 5 HU) caused by the implants and no significant resolution losses even in areas close to the inserts. To cover a variety of different cases, cadaver measurements and clinical images in the knee, head and spine region were used to investigate the effectiveness and applicability of our method. A comparison to a three-dimensional interpolation correction showed that the new approach outperformed interpolation schemes. Correction times are minimized, and initial and corrected images are made available at almost the same time (12.7 s for the initial reconstruction, 46.2 s for the final corrected image compared to 114.1 s and 355.1 s on central processing units (CPUs)).