Metal Artifact Reduction for Clipping and Coiling in Interventional C-Arm CT
Authors:
Open Access
- 26 November 2009
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 31 (4) , 634-639
Abstract
BACKGROUND AND PURPOSE: Metallic implants induce massive artifacts in CT images which deteriorate image quality and often superimpose structures of interest. The purpose of this study was to apply and evaluate a dedicated MAR method for neuroradiologic intracranial clips and detachable platinum coiling events. We here report the first clinical results for MAR in FDCT. MATERIALS AND METHODS: FDCT volume scans of several patients treated with endovascular coiling or intracranial clipping were corrected by using a dedicated FDCT MAR correction algorithm combined with an edge-preserving attenuation-normalization method in the projection space. Corrected and uncorrected images were compared by 2 experienced radiologists and evaluated for several image-quality features. RESULTS: After application of our algorithm, implant delineation and visibility were highly improved. CT values compared with values in metal artifact−unaffected areas showed good agreement (average correction of 1300 HU). Image noise was reduced overall by 27%. Intracranial hemorrhage in the direct surroundings of the implanted coil or clip material was displayed without worrisome metal artifacts, and our algorithm even allowed diagnosis in areas where extensive information losses were seen. The high spatial resolution provided by FDCT imaging was well preserved. CONCLUSIONS: Our MAR method provided metal artifact−reduced images in every studied case. It reduced image noise and corrected CT values to levels comparable with images measured without metallic implants. An overall improvement of brain tissue modeling and implant visibility was achieved. MAR in neuroradiologic FDCT imaging is a promising step forward for better image quality and diagnosis in the presence of metallic implants.Keywords
This publication has 24 references indexed in Scilit:
- Coil Migration after Endovascular Coil Occlusion of Internal Carotid Artery Pseudoaneurysms within the Sphenoid Sinusmin - Minimally Invasive Neurosurgery, 2009
- Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 casesEuropean Radiology, 2008
- Neuroradiologic Applications with Routine C-arm Flat Panel Detector CT: Evaluation of Patient Dose MeasurementsAmerican Journal of Neuroradiology, 2008
- Brain imaging with a flat detector C-armNeuroradiology, 2008
- Flat Panel Detector Angiographic CT in the Management of Aneurysmal Rupture During Coil EmbolizationAmerican Journal of Neuroradiology, 2008
- Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CTNeuroradiology, 2008
- Flat Panel Detector Angiographic CT for Stent-Assisted Coil Embolization of Broad-Based Cerebral AneurysmsAmerican Journal of Neuroradiology, 2007
- Flat-detector computed tomography (FD-CT)European Radiology, 2007
- International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusionThe Lancet, 2005
- Stenting plus Coiling bei akut rupturierten intrakraniellen AneurysmenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2005