  • Occupational exposure in MRI

    by D W Mcrobbie

    This article reviews occupational exposure in clinical MRI; it specifically considers units of exposure, basic physical interactions, health effects, guideline limits, dosimetry, results of exposure surveys, calculation of induced fields and the status of the European Physical Agents Directive. Electromagnetic field exposure in MRI from the static field B(0), imaging gradients and radiofrequency transmission fields induces electric fields and currents in tissue, which are responsible for various acute sensory effects. The underlying theory and its application to the formulation of incident and induced field limits are presented. The recent International Commission on Non-Ionizing Radiation Protection (ICNIRP) Bundesministerium für Arbeit und Soziales and Institute of Electrical and Electronics Engineers limits for incident field exposure are interpreted in a manner applicable to MRI. Field measurements show that exposure from movement within the B(0) fringe field can exceed ICNIRP reference levels within 0.5 m of the bore entrance. Rate of change of field dB/dt from the imaging gradients is unlikely to exceed the new limits, although incident field limits can be exceeded for radiofrequency (RF) exposure within 0.2-0.5 m of the bore entrance. Dosimetric surveys of routine clinical practice show that staff are exposed to peak values of 42 ± 24% of B(0), with time-averaged exposures of 5.2 ± 2.8 mT for magnets in the range 0.6-4 T. Exposure to time-varying fields arising from movement within the B(0) fringe resulted in peak dB/dt of approximately 2 T s(-1). Modelling of induced electric fields from the imaging gradients shows that ICNIRP-induced field limits are unlikely to be exceeded in most situations; however, movement through the static field may still present a problem. The likely application of the limits is discussed with respect to the reformulation of the European Union (EU) directive and its possible implications for MRI.


  • Open Access

    Contact heat evoked potentials using simultaneous EEG and fMRI and their correlation with evoked pain

    by Katherine Roberts, Anastasia Papadaki, Carla Gonçalves, Mary Tighe, Duncan Atherton, Ravikiran Shenoy, Donald McRobbie, Praveen Anand

    The Contact Heat Evoked Potential Stimulator (CHEPS) utilises rapidly delivered heat pulses with adjustable peak temperatures to stimulate the differential warm/heat thresholds of receptors expressed by Aδ and C fibres. The resulting evoked potentials can be recorded and measured, providing a useful clinical tool for the study of thermal and nociceptive pathways. Concurrent recording of contact heat evoked potentials using electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) has not previously been reported with CHEPS. Developing simultaneous EEG and fMRI with CHEPS is highly desirable, as it provides an opportunity to exploit the high temporal resolution of EEG and the high spatial resolution of fMRI to study the reaction of the human brain to thermal and nociceptive stimuli. In this study we have recorded evoked potentials stimulated by 51°C contact heat pulses from CHEPS using EEG, under normal conditions (baseline), and during continuous and simultaneous acquisition of fMRI images in ten healthy volunteers, during two sessions. The pain evoked by CHEPS was recorded on a Visual Analogue Scale (VAS). Analysis of EEG data revealed that the latencies and amplitudes of evoked potentials recorded during continuous fMRI did not differ significantly from baseline recordings. fMRI results were consistent with previous thermal pain studies, and showed Blood Oxygen Level Dependent (BOLD) changes in the insula, post-central gyrus, supplementary motor area (SMA), middle cingulate cortex and pre-central gyrus. There was a significant positive correlation between the evoked potential amplitude (EEG) and the psychophysical perception of pain on the VAS. The results of this study demonstrate the feasibility of recording contact heat evoked potentials with EEG during continuous and simultaneous fMRI. The combined use of the two methods can lead to identification of distinct patterns of brain activity indicative of pain and pro-nociceptive sensitisation in healthy subjects and chronic pain patients. Further studies are required for the technique to progress as a useful tool in clinical trials of novel analgesics.


  • Studies of the Human Oropharyngeal Airspaces Using Magnetic Resonance Imaging. III. The Effects of Device Resistance with Forced Maneuver and Tidal Breathing on Upper Airway Geometry

    by Donald W. McRobbie, Susan E. Pritchard

    The anatomical geometry of the upper airways of five healthy volunteers were studied using three-dimensional inhalation-gated magnetic resonance imaging (MRI) for two dummy inhalation devices of varying airflow resistances (0.0490.5 and 0.0040.5 kPa0.5(L/min)−1) using a forced maneuver (sharp inhalation) and tidal breathing. The range of maximum inspiratory pressures (MIP) was 0.02–6 kPa. Significant airway expansion occurred for the lower resistance device with forced maneuver compared with tidal breathing. The mean upper airway volume for forced maneuver through a low-resistance device was 60 (SD 15) cm3 compared with 38 (SD 9) cm3 for tidal breathing through the same device. Regionally, these increases occurred in the oropharynx (factor of three increase) and the laryngo-pharynx (factor of two increase). Significant changes did not occur for the buccal and laryngeal regions. No significant airway volume change occurred between the two breathing modes using the high-resistance device. In contrast to an earlier study using tidal breathing, device-related volume changes occurred with forced maneuvers in the oropharynx and laryngopharynx. For the lowresistance device, significant differences for the minimum airway equivalent radius at the epiglottis occurred between forced maneuver (8.0 mm) and tidal breathing (5.2 mm), and for the maximum airway diameter in the laryngo-pharynx (12.4 mm vs 9.1 mm). For forced maneuvers, significant differences in maximum airway diameter in the oropharynx were also apparent between the devices (12.6 mm low vs. 9.1 mm high) and also in the laryngopharynx (12.4 mm low vs. 9.4 mm high). The minimum radius at the epiglottis varied significantly between devices under forced maneuver breathing (8.0 mm low vs. 8.3 mm high). There was no correlation between airway expansion or contraction and MIP. A linear relationship was found between airway volume changes and maximum calculated volumetric airflow. This work has implication for the modeling of inhaled aerosol dynamics and in vitro particle impaction studies.


  • Studies of the Human Oropharyngeal Airspaces using Magnetic Resonance Imaging. I. Validation of a Three-Dimensional MRI Method for Producing Ex Vivo Virtual and Physical Casts of the Oropharyngeal Airways During Inspiration

    by Donald W. McRobbie, Susan Pritchard, Rebecca A. Quest

    The oropharyngeal region of the human airways has been scanned using 3D MRI and the data used to produce a model cast. The scanning method used a triggering device, which enabled data collection at the same pressure drop in each breathing cycle to produce clear images free of motion-related artefacts. A comparison between two differing MR acquisition strategies was made in a single subject, multi-session study. 3D FISP MR imaging was found to produce the most reliable data. Excluding the buccal cavity, where tongue position was critical, the reproducibility of measured airway volumes and cross sectional areas between sessions was demonstrated. Inter-session total airway volume (excluding the mouth) reproducibility was of the order of 5% and for minimum cross sectional areas at the epiglottis and vocal cords was 10%. The production of a physical cast from the images led to a 5% increase in airway volume compared with the anatomical images but with some loss of fine detail. The data demonstrated the robustness of an ex-vivo means of studying oropharyngeal dimensions and dynamics which may contribute to advancements in the understanding of aerosol delivery of therapeutic agents.