Duncan Donald Atherton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Duncan Donald Atherton has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Anastasia Papadaki
Imperial College Healthcare NHS Trust, London, UK
1 shared publication - Carla Gonçalves
Cardiovascular Magnetic Resonance and Cardiovascular Biomedical Research Units, Royal Brompton Hospital, London, UK
1 shared publication David Elliot
From the Hand Surgery Department, St. Andrew’s Centre for Plastic Surgery, Broomfield Hospital, Chelmsford, Essex, UK
1 shared publication- Donald W. McRobbie
Radiological Sciences Unit, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London, UK
1 shared publication Jan Fabre
From the Hand Surgery Department, St. Andrew’s Centre for Plastic Surgery, Broomfield Hospital, Chelmsford, Essex, UK
1 shared publication- Katherine Roberts
Imperial College Healthcare NHS Trust, London, UK
1 shared publication
Latest Publications
- 1 July 2014
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 43 (7) , 824-826
Midfacial augmentation in teenage cleft patients using malar and paranasal Medpor implants
- 1 July 2014
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 43 (7) , 824-826
Midfacial augmentation in teenage cleft patients using malar and paranasal Medpor implants
- 1 October 2010
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 63 (10) , 1629-1634
Augmentation of temporal fossa hollowing with Mersilene mesh
- 1 October 2010
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 63 (10) , 1629-1634
Augmentation of temporal fossa hollowing with Mersilene mesh
- Open Access
- 17 December 2008
- Published by Springer Nature in BMC Anesthesiology
- Vol. 8 (1) , 8
Contact heat evoked potentials using simultaneous EEG and fMRI and their correlation with evoked pain
The Contact Heat Evoked Potential Stimulator (CHEPS) utilises rapidly delivered heat pulses with adjustable peak temperatures to stimulate the differential warm/heat thresholds of receptors expressed by Aδ and C fibres. The resulting evoked potentials can be recorded and measured, providing a useful clinical tool for the study of thermal and nociceptive pathways. Concurrent recording of contact heat evoked potentials using electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) has not previously been reported with CHEPS. Developing simultaneous EEG and fMRI with CHEPS is highly desirable, as it provides an opportunity to exploit the high temporal resolution of EEG and the high spatial resolution of fMRI to study the reaction of the human brain to thermal and nociceptive stimuli. In this study we have recorded evoked potentials stimulated by 51°C contact heat pulses from CHEPS using EEG, under normal conditions (baseline), and during continuous and simultaneous acquisition of fMRI images in ten healthy volunteers, during two sessions. The pain evoked by CHEPS was recorded on a Visual Analogue Scale (VAS). Analysis of EEG data revealed that the latencies and amplitudes of evoked potentials recorded during continuous fMRI did not differ significantly from baseline recordings. fMRI results were consistent with previous thermal pain studies, and showed Blood Oxygen Level Dependent (BOLD) changes in the insula, post-central gyrus, supplementary motor area (SMA), middle cingulate cortex and pre-central gyrus. There was a significant positive correlation between the evoked potential amplitude (EEG) and the psychophysical perception of pain on the VAS. The results of this study demonstrate the feasibility of recording contact heat evoked potentials with EEG during continuous and simultaneous fMRI. The combined use of the two methods can lead to identification of distinct patterns of brain activity indicative of pain and pro-nociceptive sensitisation in healthy subjects and chronic pain patients. Further studies are required for the technique to progress as a useful tool in clinical trials of novel analgesics.
- 17 December 2008
- Published by Springer Nature in BMC Anesthesiology
- Vol. 8 (1) , 8
Open AccessContact heat evoked potentials using simultaneous EEG and fMRI and their correlation with evoked pain
The Contact Heat Evoked Potential Stimulator (CHEPS) utilises rapidly delivered heat pulses with adjustable peak temperatures to stimulate the differential warm/heat thresholds of receptors expressed by Aδ and C fibres. The resulting evoked potentials can be recorded and measured, providing a useful clinical tool for the study of thermal and nociceptive pathways. Concurrent recording of contact heat evoked potentials using electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) has not previously been reported with CHEPS. Developing simultaneous EEG and fMRI with CHEPS is highly desirable, as it provides an opportunity to exploit the high temporal resolution of EEG and the high spatial resolution of fMRI to study the reaction of the human brain to thermal and nociceptive stimuli. In this study we have recorded evoked potentials stimulated by 51°C contact heat pulses from CHEPS using EEG, under normal conditions (baseline), and during continuous and simultaneous acquisition of fMRI images in ten healthy volunteers, during two sessions. The pain evoked by CHEPS was recorded on a Visual Analogue Scale (VAS). Analysis of EEG data revealed that the latencies and amplitudes of evoked potentials recorded during continuous fMRI did not differ significantly from baseline recordings. fMRI results were consistent with previous thermal pain studies, and showed Blood Oxygen Level Dependent (BOLD) changes in the insula, post-central gyrus, supplementary motor area (SMA), middle cingulate cortex and pre-central gyrus. There was a significant positive correlation between the evoked potential amplitude (EEG) and the psychophysical perception of pain on the VAS. The results of this study demonstrate the feasibility of recording contact heat evoked potentials with EEG during continuous and simultaneous fMRI. The combined use of the two methods can lead to identification of distinct patterns of brain activity indicative of pain and pro-nociceptive sensitisation in healthy subjects and chronic pain patients. Further studies are required for the technique to progress as a useful tool in clinical trials of novel analgesics.
- 28 April 2008
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 33 (2) , 155-162
Relocation of Painful Neuromas in Zone III of the Hand and Forearm
Painful nerves are a difficult and complex clinical problem. We describe the result of treatment by proximal relocation of 51 painful end neuromas and scarred nerves of the forearm in 33 patients. The relocated nerves included 29 superficial radial nerves, 16 lateral antebrachial cutaneous nerves, two medial cutaneous nerves and four posterior cutaneous nerves. These relocations achieved no, or only mild, pain in 100% of nerves at the original site and 94% of nerves at the relocation site. It also achieved no, or only mild, hypersensitivity in 96% of nerves at the original site and 98% of nerves at the relocation site. The technical difficulties encountered in this region, in particular on the radial aspect of the wrist, are discussed.
- 28 April 2008
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 33 (2) , 155-162
Relocation of Painful Neuromas in Zone III of the Hand and Forearm
Painful nerves are a difficult and complex clinical problem. We describe the result of treatment by proximal relocation of 51 painful end neuromas and scarred nerves of the forearm in 33 patients. The relocated nerves included 29 superficial radial nerves, 16 lateral antebrachial cutaneous nerves, two medial cutaneous nerves and four posterior cutaneous nerves. These relocations achieved no, or only mild, pain in 100% of nerves at the original site and 94% of nerves at the relocation site. It also achieved no, or only mild, hypersensitivity in 96% of nerves at the original site and 98% of nerves at the relocation site. The technical difficulties encountered in this region, in particular on the radial aspect of the wrist, are discussed.