RPRamin Pashaie

Ramin Pashaie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ramin Pashaie has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Farid Atry

    University of Wisconsin Madison, Madison, Wisconsin, United States

    5 shared publications
  • Hadi Esfandi

    Affiliations Electrical Engineering and Computer Science Department, Florida Atlantic University, Boca Raton, Florida, United States of America, Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, United States of America

    5 shared publications
  • Mehdi Azimipour

    Vision Science and Advanced Retinal Imaging Laboratory (VSRI)

    5 shared publications
  • Mahshad Javidan

    Affiliations Electrical Engineering and Computer Science Department, Florida Atlantic University, Boca Raton, Florida, United States of America, Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, United States of America

    4 shared publications
  • Aaron J Suminski

    University of Wisconsin Madison College of Engineering, Madison, Wisconsin, UNITED STATES

    2 shared publications
  • Fred J. Helmstetter

    Department of Psychology

    2 shared publications

Latest Publications

  • Design and implementation of an optical coherence tomography and fluorescence microscopy platform for retinal imaging in mice

    by Parisa Nategh, Mehrnoosh Neghabi, Stefania Volpe, Mahsa Ranji, Ramin Pashaie

    We describe an optical setup that performs optical coherence tomography (OCT) and fluorescence microscopy on the mouse retina through a shared sample arm. The crystalline lens of the animal’s eye is the objective lens for both, and a tube-lens and scan-lens relay in a modified 4 f configuration works around the small entrance pupil of the eye while leaving room to mount a dichroic mirror. The platform reaches a measured axial resolution of 3.33 µm in air across a 1.4 mm field of view and 3.9 µm lateral resolution in the fluorescence path. We report how the collimator was chosen, how the relay was designed, which aberrations dominate, and how we reduced them.

  • Open Access

    Depth-dependent contributions of various vascular zones to cerebral autoregulation and functional hyperemia: An in-silico analysis

    by Hadi Esfandi, Mahshad Javidan, Rozalyn M. Anderson, Ramin Pashaie

    Autoregulation and neurovascular coupling are key mechanisms that modulate myogenic tone (MT) in vessels to regulate cerebral blood flow (CBF) during resting state and periods of increased neural activity, respectively. To determine relative contributions of distinct vascular zones across different cortical depths in CBF regulation, we developed a simplified yet detailed and computationally efficient model of the mouse cerebrovasculature. The model integrates multiple simplifications and generalizations regarding vascular morphology, the hierarchical organization of mural cells, and potentiation/inhibition of MT in vessels. Our analysis showed that autoregulation is the result of the synergy between these factors, but achieving an optimal balance across all cortical depths and throughout the autoregulation range is a complex task. This complexity explains the non-uniformity observed experimentally in capillary blood flow at different cortical depths. In silico simulations of cerebral autoregulation support the idea that the cerebral vasculature does not maintain a plateau of blood flow throughout the autoregulatory range and consists of both flat and sloped phases. We learned that small-diameter vessels with large contractility, such as penetrating arterioles and precapillary arterioles, have major control over intravascular pressure at the entry points of capillaries and play a significant role in CBF regulation. However, temporal alterations in capillary diameter contribute moderately to cerebral autoregulation and minimally to functional hyperemia. In addition, hemodynamic analysis shows that while hemodynamics within capillaries remain relatively stable across all cortical depths throughout the entire autoregulation range, significant variability in hemodynamics can be observed within the first few branch orders of precapillary arterioles or transitional zone vessels. The computationally efficient cerebrovasculature model, proposed in this study, provides a novel framework for analyzing dynamics of the CBF regulation where hemodynamic and vasodynamic interactions are the foundation on which more sophisticated models can be developed.


  • Open Access

    Systems biology analysis of vasodynamics in mouse cerebral arterioles during resting state and functional hyperemia

    by Hadi Esfandi, Mahshad Javidan, Eric R. McGregor, Rozalyn M. Anderson, Ramin Pashaie

    Cerebral hemodynamics is tightly regulated by arteriolar vasodynamics. In this study, a systems biology approach was employed to investigate how the interplay between passive, myogenic, neurogenic, and astrocytic responses shapes arteriolar vasodynamics in small rodents. A model of neurovascular coupling is proposed in which neurons inhibit and dampen the myogenic response to promote vasodilation during activation, and facilitate the myogenic response to promote rapid vasoconstriction immediately post-activation. In this model, inhibition of the myogenic response is mediated by the hyperpolarization of smooth muscle and endothelial cells. Dampening and facilitation of the response are mediated by neuronal production of nitric oxide and release of neuropeptide Y, respectively. We also introduce a model for gliovascular coupling, in which astrocytes periodically inhibit the myogenic response upon detecting an increase in myogenic activity through interactions between their endfeet and arterioles. Our study revealed that in the resting state, the interplay between the delayed myogenic response and passive distension, acting as negative and positive feedbacks respectively, generates undamped oscillations in vessel diameter, known as vasomotion. In the active state, these oscillations are disrupted by the neurogenic and astrocytic responses. The biophysical model of arteriolar vasodynamics presented in this study lays the foundation for quantitative analysis of cerebral hemodynamics for cerebrovascular health diagnostics and hemodynamic neuroimaging.

  • Open Access

    Depth-Dependent Contributions of Various Vascular Zones to Cerebral Autoregulation and Functional; Hyperemia: An In-Silico Analysis

    by Ramin Pashaie

    Autoregulation and neurogliavascular coupling are key mechanisms that modulate myogenic tone (MT) in vessels to regulate cerebral blood flow (CBF) during resting state and periods of increased neural activity, respectively. To determine relative contributions of distinct vascular zones across different cortical depths in CBF regulation, we developed a simplified yet detailed and computationally efficient model of the mouse cerebrovasculature. The model integrates multiple simplifications and generalizations regarding vascular morphology, the hierarchical organization of mural cells, and potentiation/inhibition of MT in vessels. Our analysis showed that autoregulation is the result of the synergy between these factors, but achieving an optimal balance across all cortical depths and throughout the autoregulation range is a complex task. This complexity explains the non-uniformity observed experimentally in capillary blood flow at different cortical depths. In silico simulations of cerebral autoregulation support the idea that the cerebral vasculature does not maintain a plateau of blood flow throughout the autoregulatory range and consists of both flat and sloped phases. We learned that small-diameter vessels with large contractility, such as penetrating arterioles and precapillary arterioles, have major control over intravascular pressure at the entry points of capillaries and play a significant role in CBF regulation. However, temporal alterations in capillary diameter contribute moderately to cerebral autoregulation and minimally to functional hyperemia. In addition, hemodynamic analysis shows that while hemodynamics within capillaries remain relatively stable across all cortical depths throughout the entire autoregulation range, significant variability in hemodynamics can be observed within the first few branch orders of precapillary arterioles or transitional zone vessels. The computationally efficient cerebrovasculature model, proposed in this study, provides a novel framework for analyzing dynamics of the CBF regulation where hemodynamic and vasodynamic interactions are the foundation on which more sophisticated models can be developed.


  • Illumination pattern optimization in tomography based on the Kalman estimation filter and optimal experiment design

    by Ramin Pashaie

    Tomography is widely used in medical imaging or industrial non-destructive testing applications. One costly and time consuming operation in any form of tomography is the process of data acquisition where a large number of measurements are made and collected data is used for image reconstruction. Data acquisition can slow down tomography to the point that the scanner cannot catch up with the speed of changes in the medium under test. By optimizing the information content of each measurement, we can reduce the number of measurements needed to achieve the target precision. Development of algorithms to optimize the information content of tomography measurements is the main goal of this article. Here, the dynamics of the medium and tomography measurements are formulated in the form of a Kalman estimation filter. A mathematical algorithm is developed to compute the optimal measurement matrix which minimizes the uncertainty left in the estimation of the distribution the tomography scanner is reconstructing. Results, as presented in the paper, show noticeable improvement is the quality of generated images when the medium is scanned by optimal measurements instead of traditional raster or random scanning protocols.


  • Optimal data acquisition in tomography

    by Mahshad Javidan, Hadi Esfandi, Rozalyn Anderson, Ramin Pashaie

    In tomography, three-dimensional images of a medium are reconstructed from a set of two-dimensional projections. Each projection is the result of a measurement made by the scanner via radiating some form of energy and collecting the scattered field after interacting with the medium. The information content of these measurements is not equal, and one projection can be more informative than others. By choosing the most informative measurement at every step of scanning, an optimal tomography system can maximize the speed of data acquisition and temporal resolution of acquired images, reducing the operation cost and exposure to possible harmful radiations. The aim of this paper is to introduce mathematical algorithms that can be used to design measurements with optimal information content when imaging static or dynamically evolving objects.


  • Optimal Scanning Protocol for Optical Tomography

    by Mahshad Javidan, Hadi Esfandi, Ramin Pashaie

    Tomography is a two step process in which the sample under test is first scanned by the hardware of the system to acquire data and then the operating software reconstruct images from the gathered information. The main objective of this work is to optimize the scanning process to acquire maximum amount of information in each measurement when the system is scanning the sample. By exploiting our prior information about the sample and using estimation theory, we developed a systematic approach to implement the optimal scanning protocol. Results of this study provide strong evidence that the developed algorithms can speed up data acquisition. Also it is shown that the proposed method can reduce the impact of noise as well as improving the reconstruction error while performing less number of measurements.Clinical relevance— The proposed method can enhance data acquisition time, exposure dosage and cost of operation in medical applications of tomography.

  • Open Access

    Optimization of data acquisition operation in optical tomography based on estimation theory

    by Mahshad Javidan, Hadi Esfandi, Ramin Pashaie

    The data acquisition process is occasionally the most time consuming and costly operation in tomography. Currently, raster scanning is still the common practice in making sequential measurements in most tomography scanners. Raster scanning is known to be slow and such scanners usually cannot catch up with the speed of changes when imaging dynamically evolving objects. In this research, we studied the possibility of using estimation theory and our prior knowledge about the sample under test to reduce the number of measurements required to achieve a given image quality. This systematic approach for optimization of the data acquisition process also provides a vision toward improving the geometry of the scanner and reducing the effect of noise, including the common state-dependent noise of detectors. The theory is developed in the article and simulations are provided to better display discussed concepts.


  • A system identification analysis of optogenetically evoked electrocorticography and cerebral blood flow responses

    by Rex Chin-Hao Chen, Farid Atry, Thomas Richner, Sarah K Brodnick, Jane Pisaniello, Jared Ness, Aaron J Suminski, Justin C Williams, Ramin Pashaie

    Objective . The main objective of this research was to study the coupling between neural circuits and the vascular network in the cortex of small rodents from system engineering point of view and generate a mathematical model for the dynamics of neurovascular coupling. The model was adopted to implement closed-loop blood flow control algorithms. Approach. We used a combination of advanced technologies including optogenetics, electrocorticography, and optical coherence tomography to stimulate selected populations of neurons and simultaneously record induced electrocorticography and hemodynamic signals. We adopted system identification methods to analyze the acquired data and investigate the relation between optogenetic neural activation and consequential electrophysiology and blood flow responses. Main results. We showed that the developed model, once trained by the acquired data, could successfully regenerate subtle spatio-temporal features of evoked electrocorticography and cerebral blood flow responses following an onset of optogenetic stimulation. Significance. The long term goal of this research is to open a new line for computational analysis of neurovascular coupling particularly in pathologies where the normal process of blood flow regulation in the central nervous system is disrupted including Alzheimer’s disease.