Peter Ammann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Ammann has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Christian Sticherling
Department of Cardiology, University Hospital Basel, University Basel , Basel
5 shared publications Hans Rickli
Division of Cardiology, Kantonsspital St. Gallen, St. Gallen, Switzerland
5 shared publications- Hans Rickli
Cardiology Division, Kantonsspital St. Gallen, Switzerland
3 shared publications - Beat Schaer
Department of Cardiology, University Hospital Basel , Universitätsspital CH, Petersgraben 4, 4031 Basel
2 shared publications - Firat Duru
Department of Cardiology, University Hospital Zurich, Zurich, Switzerland
2 shared publications Markus Sagmeister
Department of Internal Medicine, Kantonsspital St. Gallen, St. Gallen, Switzerland
2 shared publications
Latest Publications
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Impact of comorbidities on survival and complications in patients implanted with leadless pacemakers: a national, multicenter study
Background: The number of leadless cardiac pacemaker (LCP) implantations has increased over the recent years, being more frequently performed in elderly patients with multiple comorbidities. Purpose: The aim of this study is to analyze periprocedural complications and outcome of LCP patients according to their comorbidity status. Methods: This is a Swiss multi-centre, retrospective cohort study including all consecutive patients implanted with a LCP (Medtronic Micra VR or AV) between 2015 and 2022. Charlson Comorbidity Index (CCI) was determined and patients were divided into two groups: CCI ≤ 5 (low comorbidity) and CCI > 5 (high comorbidity). Periprocedural complications, in-hospital death, and all-cause mortality were assessed. Results: A total of 863 patients (median age 81 years (IQR 76 – 86), male sex 65%) were included in the study, of which 58% had a CCI ≤ 5. Baseline characteristics of the 2 groups are summarized in the table. Patients in the high comorbidity group were older male presenting more frequently with ischemic cardiomyopathy, diabetes, chronic obstructive pulmonary disease, moderate to severe chronic kidney disease and malignancies. Urgent implantations were more frequent in the high comorbidity than in the low comorbidity group (65% vs. 50%, p<0.001). Overall periprocedural complication rate was 2.9% (n = 25) without significant differences between the two groups (2.9% in both groups, p = 1.0). Pericardial effusion requiring pericardiocentesis was the most frequent periprocedural complication (n = 8, 0.9%). Median hospitalization was significantly longer (5 vs. 3 days, p<0.001), and in-hospital mortality significantly higher (3.6% vs. 0.6%, p=0.002) in the high comorbidity group. None of the in-hospital deaths was deemed a periprocedural complication. Median follow-up was 15.4 months. As shown in the figure, all-cause mortality was significantly higher in the high morbidity group (HR 2.9, 95%-CI 2.2-3.8, p<0.001) resulting in a mortality of 58% at 3 years. Conclusions: LCP implantation in patients with multiple comorbidities was equally safe with similar peri-procedural complication rates as compared to patients with less comorbidities. However, both in-hospital death and all-cause mortality during follow-up were significantly higher in the high comorbidity group, because patients were older and sicker. Given that costs of LCPs are substantially higher than standard transvenous pacemakers, further studies are necessary to assess cost-effectiveness in patients with high comorbidity and reduced life expectancy.Figure - Survival estimate according CCITable - Baseline characteristics
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessImpact of comorbidities on survival and complications in patients implanted with leadless pacemakers: a national, multicenter study
Background: The number of leadless cardiac pacemaker (LCP) implantations has increased over the recent years, being more frequently performed in elderly patients with multiple comorbidities. Purpose: The aim of this study is to analyze periprocedural complications and outcome of LCP patients according to their comorbidity status. Methods: This is a Swiss multi-centre, retrospective cohort study including all consecutive patients implanted with a LCP (Medtronic Micra VR or AV) between 2015 and 2022. Charlson Comorbidity Index (CCI) was determined and patients were divided into two groups: CCI ≤ 5 (low comorbidity) and CCI > 5 (high comorbidity). Periprocedural complications, in-hospital death, and all-cause mortality were assessed. Results: A total of 863 patients (median age 81 years (IQR 76 – 86), male sex 65%) were included in the study, of which 58% had a CCI ≤ 5. Baseline characteristics of the 2 groups are summarized in the table. Patients in the high comorbidity group were older male presenting more frequently with ischemic cardiomyopathy, diabetes, chronic obstructive pulmonary disease, moderate to severe chronic kidney disease and malignancies. Urgent implantations were more frequent in the high comorbidity than in the low comorbidity group (65% vs. 50%, p<0.001). Overall periprocedural complication rate was 2.9% (n = 25) without significant differences between the two groups (2.9% in both groups, p = 1.0). Pericardial effusion requiring pericardiocentesis was the most frequent periprocedural complication (n = 8, 0.9%). Median hospitalization was significantly longer (5 vs. 3 days, p<0.001), and in-hospital mortality significantly higher (3.6% vs. 0.6%, p=0.002) in the high comorbidity group. None of the in-hospital deaths was deemed a periprocedural complication. Median follow-up was 15.4 months. As shown in the figure, all-cause mortality was significantly higher in the high morbidity group (HR 2.9, 95%-CI 2.2-3.8, p<0.001) resulting in a mortality of 58% at 3 years. Conclusions: LCP implantation in patients with multiple comorbidities was equally safe with similar peri-procedural complication rates as compared to patients with less comorbidities. However, both in-hospital death and all-cause mortality during follow-up were significantly higher in the high comorbidity group, because patients were older and sicker. Given that costs of LCPs are substantially higher than standard transvenous pacemakers, further studies are necessary to assess cost-effectiveness in patients with high comorbidity and reduced life expectancy.Figure - Survival estimate according CCITable - Baseline characteristics
- Open Access
- 13 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (10) , 2879
Pulmonary Vein Isolation for Atrial Fibrillation: Comparison of a Very High-Power Very Short-Duration (vHPvSD) Ablation Protocol versus a Hybrid Ablation Approach—Procedural and Mid-Term Outcome Data
Background: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is a standard-of-care treatment in the rhythm control strategy of symptomatic atrial fibrillation (AF). Ablation protocols, varying in the power and duration of energy delivery, have changed rapidly in recent years. Very high-power very short-duration ablation (vHPvSD) is expected to shorten procedural times compared to conventional ablation approaches. However, the existing data suggest that this might come at the cost of lower first-pass isolation rates, a predictor of poor ablation long-term outcomes. This study aims to compare a vHPvSD protocol to a hybrid strategy, in which the power and duration of the energy transfer are adapted depending on the anatomical location. Methods: We retrospectively analyzed procedural and outcome data from 93 patients (55 vHPvSD vs. 38 hybrid) scheduled for de novo pulmonary vein isolation. A vHPvSD ablation protocol (90 Watt (W), 4 s) was compared to a hybrid protocol using vHPvSD on the posterior wall and 50 W HPSD (high-power short-duration) ablation guided by the Ablation Index along the remaining spots. Results: Ablation times were significantly shorter in the vHPvSD cohort (5.4 min. vs. 14.2 min, p < 0.001), thus resulting in a significant reduction in the overall procedural duration (91 min vs. 106 min, p = 0.003). The non-significant slightly higher first-pass isolation rates in the vHPvSD cohort (85% vs. 76%, p = 0.262) did not affect freedom from AF 6 months after the procedure (83% vs. 87%, p = 0.622). Conclusions: vHPvSD helps in shortening the PVI procedural duration, thus neither affecting first-pass isolation rates nor freedom from atrial tachyarrhythmia recurrence at 6 months after the index procedure.
- 13 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (10) , 2879
Open AccessPulmonary Vein Isolation for Atrial Fibrillation: Comparison of a Very High-Power Very Short-Duration (vHPvSD) Ablation Protocol versus a Hybrid Ablation Approach—Procedural and Mid-Term Outcome Data
Background: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is a standard-of-care treatment in the rhythm control strategy of symptomatic atrial fibrillation (AF). Ablation protocols, varying in the power and duration of energy delivery, have changed rapidly in recent years. Very high-power very short-duration ablation (vHPvSD) is expected to shorten procedural times compared to conventional ablation approaches. However, the existing data suggest that this might come at the cost of lower first-pass isolation rates, a predictor of poor ablation long-term outcomes. This study aims to compare a vHPvSD protocol to a hybrid strategy, in which the power and duration of the energy transfer are adapted depending on the anatomical location. Methods: We retrospectively analyzed procedural and outcome data from 93 patients (55 vHPvSD vs. 38 hybrid) scheduled for de novo pulmonary vein isolation. A vHPvSD ablation protocol (90 Watt (W), 4 s) was compared to a hybrid protocol using vHPvSD on the posterior wall and 50 W HPSD (high-power short-duration) ablation guided by the Ablation Index along the remaining spots. Results: Ablation times were significantly shorter in the vHPvSD cohort (5.4 min. vs. 14.2 min, p < 0.001), thus resulting in a significant reduction in the overall procedural duration (91 min vs. 106 min, p = 0.003). The non-significant slightly higher first-pass isolation rates in the vHPvSD cohort (85% vs. 76%, p = 0.262) did not affect freedom from AF 6 months after the procedure (83% vs. 87%, p = 0.622). Conclusions: vHPvSD helps in shortening the PVI procedural duration, thus neither affecting first-pass isolation rates nor freedom from atrial tachyarrhythmia recurrence at 6 months after the index procedure.
- Open Access
- 28 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (19) , 4453
Prospective Evaluation of a Standardized Screening for Atrial Fibrillation after Ablation of Cavotricuspid Isthmus Dependent Atrial Flutter
Aims: We aimed to prospectively investigate the effectiveness of a standardized follow-up for AF-detection after common atrial flutter (cAFL) ablation. Methods: A total of 309 patients after cAFL ablation without known AF, from 5 centers, and at least one completed, standardized follow-up at 3, 6 and 12 months, including a 24 h Holter-electrocardiogram (ECG), were included. The primary outcome was incident atrial fibrillation (AF), or atrial tachycardia (AT). Predictors were investigated by Cox proportional-hazards models. Results: The mean age was 67.9 years; 15.2% were female and the mean CHA2DS2-VASc (Congestive heart failure, Hypertension, Age, Diabetes, Stroke, Vascular disease, Sex category) score was 2.4 points. The great majority of patients (90.3%) were anticoagulated. Over a mean follow-up of 12.2 months with a standardized approach, AF/AT was detected in 73 patients, corresponding to 11.7% at 3 months, 18.4% at 6 months and 28.2% at 12 months of follow-up. AF was found in 64 patients, AT in 9 and both in 2 patients. Occurrence of AF was recorded in 40 (60.6%) patients by Holter-ECG and in the remaining 26 (39.4%) by clinical follow-up only. There was no difference in male versus female (p = 0.08), or in younger versus older patients (p = 0.96) for AF/AT detection. Only coronary artery disease (hazard ratio [95% confidence intervals] 1.03 [1.01–1.05], p = 0.01) was associated with the primary outcome. Conclusions: AF or AT was detected in a large proportion of cAFL patients after cavotricuspid-isthmus (CTI) ablation, using a standardized follow-up over 1 year. This standardized screening can be easily implemented with high patient acceptance. The high proportion of post-ablation AF needs to be taken into consideration when deciding on long-term oral anticoagulation.
- 28 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (19) , 4453
Open AccessProspective Evaluation of a Standardized Screening for Atrial Fibrillation after Ablation of Cavotricuspid Isthmus Dependent Atrial Flutter
Aims: We aimed to prospectively investigate the effectiveness of a standardized follow-up for AF-detection after common atrial flutter (cAFL) ablation. Methods: A total of 309 patients after cAFL ablation without known AF, from 5 centers, and at least one completed, standardized follow-up at 3, 6 and 12 months, including a 24 h Holter-electrocardiogram (ECG), were included. The primary outcome was incident atrial fibrillation (AF), or atrial tachycardia (AT). Predictors were investigated by Cox proportional-hazards models. Results: The mean age was 67.9 years; 15.2% were female and the mean CHA2DS2-VASc (Congestive heart failure, Hypertension, Age, Diabetes, Stroke, Vascular disease, Sex category) score was 2.4 points. The great majority of patients (90.3%) were anticoagulated. Over a mean follow-up of 12.2 months with a standardized approach, AF/AT was detected in 73 patients, corresponding to 11.7% at 3 months, 18.4% at 6 months and 28.2% at 12 months of follow-up. AF was found in 64 patients, AT in 9 and both in 2 patients. Occurrence of AF was recorded in 40 (60.6%) patients by Holter-ECG and in the remaining 26 (39.4%) by clinical follow-up only. There was no difference in male versus female (p = 0.08), or in younger versus older patients (p = 0.96) for AF/AT detection. Only coronary artery disease (hazard ratio [95% confidence intervals] 1.03 [1.01–1.05], p = 0.01) was associated with the primary outcome. Conclusions: AF or AT was detected in a large proportion of cAFL patients after cavotricuspid-isthmus (CTI) ablation, using a standardized follow-up over 1 year. This standardized screening can be easily implemented with high patient acceptance. The high proportion of post-ablation AF needs to be taken into consideration when deciding on long-term oral anticoagulation.
- Open Access
- 25 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (17) , 3811
High Incidence of Inappropriate Alarms in Patients with Wearable Cardioverter-Defibrillators: Findings from the Swiss WCD Registry
Background: The wearable cardioverter defibrillator (WCD) uses surface electrodes to detect arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. Objective: The aim of this study is to assess the alarm burden in patients and its impact on clinical outcomes. Methods: Patients from the nationwide Swiss WCD Registry were included. Clinical characteristics and data were obtained from the WCDs. Arrhythmia recordings ≥30 s in length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia (SVT) or artefact. Results: A total of 10653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0 ± 1.6 months. Episode duration was 30 s or more in 2996 alarms (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) SVT). Two-hundred and seven patients (45%) had three or more alarms per month. Obesity was significantly associated with three or more alarms per month (p = 0.01, 27.7% vs. 15.9%). High alarm burden was not associated with a lower average daily wear time (20.8 h vs. 20.7 h, p = 0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs. 47.3%, p = 0.156). Conclusions: In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden was associated with obesity but did not lead to a decreased adherence.
- 25 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (17) , 3811
Open AccessHigh Incidence of Inappropriate Alarms in Patients with Wearable Cardioverter-Defibrillators: Findings from the Swiss WCD Registry
Background: The wearable cardioverter defibrillator (WCD) uses surface electrodes to detect arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. Objective: The aim of this study is to assess the alarm burden in patients and its impact on clinical outcomes. Methods: Patients from the nationwide Swiss WCD Registry were included. Clinical characteristics and data were obtained from the WCDs. Arrhythmia recordings ≥30 s in length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia (SVT) or artefact. Results: A total of 10653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0 ± 1.6 months. Episode duration was 30 s or more in 2996 alarms (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) SVT). Two-hundred and seven patients (45%) had three or more alarms per month. Obesity was significantly associated with three or more alarms per month (p = 0.01, 27.7% vs. 15.9%). High alarm burden was not associated with a lower average daily wear time (20.8 h vs. 20.7 h, p = 0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs. 47.3%, p = 0.156). Conclusions: In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden was associated with obesity but did not lead to a decreased adherence.
- Open Access
- 3 February 2010
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 5 (2) , e9017
Elevated Cardiac Troponin I in Sepsis and Septic Shock: No Evidence for Thrombus Associated Myocardial Necrosis
Elevated cardiac troponin I (cTnI) is frequently observed in patients with severe sepsis and septic shock. However, the mechanisms underlying cTnI release in these patients are still unknown. To date no data regarding coagulation disturbances as a possible mechanism for cTnI release during sepsis are available. Consecutive patients with systemic inflammatory response syndrome (SIRS), sepsis or septic shock without evidence of an acute coronary syndrome were analyzed. Coagulation parameters (clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), α-angle) were assessed in native whole blood samples, and using specific activators to evaluate the extrinsic and intrinsic as well as the fibrin component of the coagulation pathway with the use of rotational thrombelastometry (ROTEM). Thirty-eight patients were included and 22 (58%) were cTnI-positive. Baseline characteristics between TnI-positive and -negative patients were similar. The CT, CFT, MCF and the α-angle were similar between the groups with trends towards shorter CT in the extrinsic and fibrin activation. We found no differences in coagulation parameters analyzed with rotational thrombelastometry between cTnI-positive and -negative patients with SIRS, severe sepsis, and septic shock. These findings suggest that pathophysiological mechanisms other than thrombus-associated myocardial damage might play a major role, including reversible myocardial membrane leakage and/or cytokine mediated apoptosis in these patients.
- 3 February 2010
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 5 (2) , e9017
Open AccessElevated Cardiac Troponin I in Sepsis and Septic Shock: No Evidence for Thrombus Associated Myocardial Necrosis
Elevated cardiac troponin I (cTnI) is frequently observed in patients with severe sepsis and septic shock. However, the mechanisms underlying cTnI release in these patients are still unknown. To date no data regarding coagulation disturbances as a possible mechanism for cTnI release during sepsis are available. Consecutive patients with systemic inflammatory response syndrome (SIRS), sepsis or septic shock without evidence of an acute coronary syndrome were analyzed. Coagulation parameters (clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), α-angle) were assessed in native whole blood samples, and using specific activators to evaluate the extrinsic and intrinsic as well as the fibrin component of the coagulation pathway with the use of rotational thrombelastometry (ROTEM). Thirty-eight patients were included and 22 (58%) were cTnI-positive. Baseline characteristics between TnI-positive and -negative patients were similar. The CT, CFT, MCF and the α-angle were similar between the groups with trends towards shorter CT in the extrinsic and fibrin activation. We found no differences in coagulation parameters analyzed with rotational thrombelastometry between cTnI-positive and -negative patients with SIRS, severe sepsis, and septic shock. These findings suggest that pathophysiological mechanisms other than thrombus-associated myocardial damage might play a major role, including reversible myocardial membrane leakage and/or cytokine mediated apoptosis in these patients.
- 5 January 2010
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 99 (4) , 243-245
Unusual cause of syncope in young girl: arrhythmogenic right ventricular cardiomyopathy
- 5 January 2010
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 99 (4) , 243-245
Unusual cause of syncope in young girl: arrhythmogenic right ventricular cardiomyopathy
- 1 March 2008
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 120 (5-6) , 128-135
Medikamentös induzierte Verlängerung des QT-Intervalls
Prolongation of the ventricular repolarisation manifests itself as a prolongation of the QT intervall on the surface ECG and represents a major risk for a special form of ventricular tachycardia called "torsades de pointes". Torsades de pointes are often self limited and are associated with palpitations, dizziness or syncope. Degeneration into ventricular fibrillation and sudden cardiac death can occur. In addition to the various forms of the congenital long QT syndrome many drugs, such as antiarrhythmic drugs class IA and III, antibiotics, antihistamines, antidepressants, and methadone are known to prolong the QT interval. Most of these drugs block a specific potassium channel substantially involved in the ventricular repolarisation. In addition, drug interaction or disturbances of drug metabolism may play a major role in the acquired form of the long QT syndrome. The individual risk and the potential of a pharmacologic substance to prolong the QT interval are not predictable. Certain risk factors identify patients at higher risk for drug-induced prolongation of the QT interval. Correctable factors include electrolyte disorders (e.g. hypokalemia) and concomitant administration of different QT prolonging drugs. External defibrillation is the therapy of choice in the hemodynamic unstable patient presenting torsades de pointes. In hemodynamic more stable patients application of intravenous magnesium can terminate torsades de pointes (membrane stabilizing properties). Temporary external or transvenous pacing at high heart rate might terminate incessant torsades de pointes by decreasing QT interval. Repeated ECG controls during therapy with QT prolonging drugs are mandatory, especially when drug doses are changed, additional drugs are prescribed, or in case of vomiting and diarrhea. QT prolongation in individual medical therapy is not always predictable. Therefore, updated lists of drugs with the potential of QT prolongation are available on the Internet (e.g. www.qtdrugs.org ).
- 1 March 2008
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 120 (5-6) , 128-135
Medikamentös induzierte Verlängerung des QT-Intervalls
Prolongation of the ventricular repolarisation manifests itself as a prolongation of the QT intervall on the surface ECG and represents a major risk for a special form of ventricular tachycardia called "torsades de pointes". Torsades de pointes are often self limited and are associated with palpitations, dizziness or syncope. Degeneration into ventricular fibrillation and sudden cardiac death can occur. In addition to the various forms of the congenital long QT syndrome many drugs, such as antiarrhythmic drugs class IA and III, antibiotics, antihistamines, antidepressants, and methadone are known to prolong the QT interval. Most of these drugs block a specific potassium channel substantially involved in the ventricular repolarisation. In addition, drug interaction or disturbances of drug metabolism may play a major role in the acquired form of the long QT syndrome. The individual risk and the potential of a pharmacologic substance to prolong the QT interval are not predictable. Certain risk factors identify patients at higher risk for drug-induced prolongation of the QT interval. Correctable factors include electrolyte disorders (e.g. hypokalemia) and concomitant administration of different QT prolonging drugs. External defibrillation is the therapy of choice in the hemodynamic unstable patient presenting torsades de pointes. In hemodynamic more stable patients application of intravenous magnesium can terminate torsades de pointes (membrane stabilizing properties). Temporary external or transvenous pacing at high heart rate might terminate incessant torsades de pointes by decreasing QT interval. Repeated ECG controls during therapy with QT prolonging drugs are mandatory, especially when drug doses are changed, additional drugs are prescribed, or in case of vomiting and diarrhea. QT prolongation in individual medical therapy is not always predictable. Therefore, updated lists of drugs with the potential of QT prolongation are available on the Internet (e.g. www.qtdrugs.org ).
- 21 June 2005
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 142 (12_Part_1) , 968-973
An Electrocardiogram-Based Algorithm To Detect Loss of Left Ventricular Capture during Cardiac Resynchronization Therapy
Loss of left ventricular capture in patients with cardiac resynchronization devices may account for worsening heart failure and can be difficult to diagnose without a programmer. To determine whether distinct morphologic changes on the surface electrocardiogram indicate loss of left ventricular capture. After analysis of the R–S spike ratio in the 12-lead electrocardiogram during right ventricular and biventricular pacing in 10 patients, an algorithm to detect loss of left ventricular capture was developed. University hospital. 54 patients with a cardiac resynchronization device and underlying left bundle-branch block. Leads V1 and I of a 12-lead electrocardiogram were assessed after biventricular pacing was confirmed and after the device was programmed to right ventricular pacing only (simulating loss of left ventricular capture). The sensitivity of the algorithm to correctly identify loss of left ventricular capture was 94% (95% CI, 88.2% to 97.7%), and the specificity was 93% (CI, 86.3% to 95.8%). The likelihood ratio of a positive test result was 12.8 (CI, 6.443 to 23.310), and the likelihood ratio of a negative test result was 0.06 (CI, 0.024 to 0.137). The algorithm was tested in patients in whom the right ventricular electrode was placed in the apex of the right ventricle only. Presence of biventricular capture—the prerequisite for successful cardiac resynchronization therapy—and loss of left ventricular capture can be accurately detected by an algorithm based on analysis of the R–S ratio on leads V1 and I of the surface electrocardiogram.
- 21 June 2005
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 142 (12_Part_1) , 968-973
An Electrocardiogram-Based Algorithm To Detect Loss of Left Ventricular Capture during Cardiac Resynchronization Therapy
Loss of left ventricular capture in patients with cardiac resynchronization devices may account for worsening heart failure and can be difficult to diagnose without a programmer. To determine whether distinct morphologic changes on the surface electrocardiogram indicate loss of left ventricular capture. After analysis of the R–S spike ratio in the 12-lead electrocardiogram during right ventricular and biventricular pacing in 10 patients, an algorithm to detect loss of left ventricular capture was developed. University hospital. 54 patients with a cardiac resynchronization device and underlying left bundle-branch block. Leads V1 and I of a 12-lead electrocardiogram were assessed after biventricular pacing was confirmed and after the device was programmed to right ventricular pacing only (simulating loss of left ventricular capture). The sensitivity of the algorithm to correctly identify loss of left ventricular capture was 94% (95% CI, 88.2% to 97.7%), and the specificity was 93% (CI, 86.3% to 95.8%). The likelihood ratio of a positive test result was 12.8 (CI, 6.443 to 23.310), and the likelihood ratio of a negative test result was 0.06 (CI, 0.024 to 0.137). The algorithm was tested in patients in whom the right ventricular electrode was placed in the apex of the right ventricle only. Presence of biventricular capture—the prerequisite for successful cardiac resynchronization therapy—and loss of left ventricular capture can be accurately detected by an algorithm based on analysis of the R–S ratio on leads V1 and I of the surface electrocardiogram.
- 16 February 2005
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (4) , 399-401
Induction Ovens and Electromagnetic Interference: What Is the Risk for Patients with Implantable Cardioverter Defibrillators?
- 16 February 2005
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 16 (4) , 399-401
Induction Ovens and Electromagnetic Interference: What Is the Risk for Patients with Implantable Cardioverter Defibrillators?
- 16 July 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 62 (4) , 432-438
Coronary anatomy and left ventricular ejection fraction in patients with type 2 diabetes admitted for elective coronary angiography
- 16 July 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 62 (4) , 432-438
Coronary anatomy and left ventricular ejection fraction in patients with type 2 diabetes admitted for elective coronary angiography