Federica Censi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Federica Censi has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Giovanni Calcagnini
Dipartimento di Malattie Cardiovascolari, Endocrino-Metaboliche e Invecchiamento, Istituto Superiore di Sanità, Roma, Italia
24 shared publications- Eugenio Mattei
Department of Cardiovascular, Endocrine-Metabolic Diseases and Aging, Italian National Institute of Health, 00161 Rome, Italy
22 shared publications Pietro Bartolini
Dipartimento di Tecnologie e Salute, Istituto Superiore di Sanità, Rome, Italy
21 shared publications- Giovanni Calcagnini
Department of Cardiovascular, Endocrine-Metabolic Diseases and Aging, Italian National Institute of Health, 00161 Rome, Italy
11 shared publications - Michele Triventi
Italian National Institute of Health, Rome, Italy
9 shared publications - Giuseppe Boriani
Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, 41124 Modena, Italy
8 shared publications
Latest Publications
- Open Access
- 4 August 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (8)
Magnetic interference from consumer devices: a renewed challenge for the safety of cardiac implantable electronic devices
- 4 August 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (8)
Open AccessMagnetic interference from consumer devices: a renewed challenge for the safety of cardiac implantable electronic devices
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 66 (1) , 97-107
Electromagnetic Immunity of Pacemakers and Implantable Defibrillators to Wireless Power Transfer Systems for Automotive: A Provocative Study
Wireless power transfer (WPT) in automotive is an emerging technology that utilizes coupled coils to transfer power through time-varying magnetic fields, enabling the charging of electric vehicles. Like any electromagnetic field source, WPT systems can potentially interfere with other electronic devices, impacting their proper functioning. This risk requires evaluation, especially when the affected device is a cardiac implantable electronic device (CIED), as malfunctioning can pose serious hazards to the patient's safety. Currently, WPT technology is in its early stages and has not been explicitly considered during the drafting of current CIED regulations. Consequently, predicting the behavior of a CIED when in proximity to a WPT system is not straightforward, and new experimental data are necessary. The objective of this article is to conduct in-vitro testing on a representative sample of pacemakers (PMs) and implantable cardioverter/defibrillators exposed to a magnetic field at the frequency of WTP systems, with field levels gradually increasing up to ICNIRP occupational reference levels. Compared to previous studies, the main novelty is to assess, on 11 commercial CIEDs, a safety margin for the exposure to the magnetic field dispersed by a WPT system, under worst-case exposure condition. Over a total of 51 conducted tests 24 interfering events were observed: only 1 occurred with a magnetic field at 50 μ T while all the others were observed with higher field levels, at 75 and 100 μ T. Thus, the results of this research demonstrate that the risk of interference is very low. Electromagnetic interference phenomena were observed only under worst-case conditions (e.g., maximum sensitivity of the device, maximum lead loop area, pulsed modulation, and unipolar configuration for PMs) and at exposure levels above the ICNIRP general population reference levels.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 66 (1) , 97-107
Electromagnetic Immunity of Pacemakers and Implantable Defibrillators to Wireless Power Transfer Systems for Automotive: A Provocative Study
Wireless power transfer (WPT) in automotive is an emerging technology that utilizes coupled coils to transfer power through time-varying magnetic fields, enabling the charging of electric vehicles. Like any electromagnetic field source, WPT systems can potentially interfere with other electronic devices, impacting their proper functioning. This risk requires evaluation, especially when the affected device is a cardiac implantable electronic device (CIED), as malfunctioning can pose serious hazards to the patient's safety. Currently, WPT technology is in its early stages and has not been explicitly considered during the drafting of current CIED regulations. Consequently, predicting the behavior of a CIED when in proximity to a WPT system is not straightforward, and new experimental data are necessary. The objective of this article is to conduct in-vitro testing on a representative sample of pacemakers (PMs) and implantable cardioverter/defibrillators exposed to a magnetic field at the frequency of WTP systems, with field levels gradually increasing up to ICNIRP occupational reference levels. Compared to previous studies, the main novelty is to assess, on 11 commercial CIEDs, a safety margin for the exposure to the magnetic field dispersed by a WPT system, under worst-case exposure condition. Over a total of 51 conducted tests 24 interfering events were observed: only 1 occurred with a magnetic field at 50 μ T while all the others were observed with higher field levels, at 75 and 100 μ T. Thus, the results of this research demonstrate that the risk of interference is very low. Electromagnetic interference phenomena were observed only under worst-case conditions (e.g., maximum sensitivity of the device, maximum lead loop area, pulsed modulation, and unipolar configuration for PMs) and at exposure levels above the ICNIRP general population reference levels.
- Open Access
- 5 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2864
Personalized Antiarrhythmic Therapy Using a Self-Managed Daily-ECG Device
A 50-year-old Caucasian man arrived at the emergency department presenting paucisymptomatic atrial fibrillation. Once discharged after the appropriate treatments, the patient continued to have paucisymptomatic episodes. For this reason, he was provided with the Cardionica device which made it possible to better investigate the type of arrhythmic episodes, in order to tailor his therapy and to finally restore a normal sinus rhythm in the patient.
- 5 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2864
Open AccessPersonalized Antiarrhythmic Therapy Using a Self-Managed Daily-ECG Device
A 50-year-old Caucasian man arrived at the emergency department presenting paucisymptomatic atrial fibrillation. Once discharged after the appropriate treatments, the patient continued to have paucisymptomatic episodes. For this reason, he was provided with the Cardionica device which made it possible to better investigate the type of arrhythmic episodes, in order to tailor his therapy and to finally restore a normal sinus rhythm in the patient.
- 17 May 2023
- Published by Wolters Kluwer Health in Health Physics
- Vol. 125 (3) , 202-206
Pacemakers, Implantable Defibrillators, and 5G Technology: What We Need to Know
Pacemakers (PM) and implantable cardioverter defibrillators (ICD) are active implantable medical devices (AIMD) needed in case of cardiac arrhythmias. Given their potentially life-sustaining nature, the interaction between any source of electromagnetic field and these AIMDs is an ongoing concern of patients, industry, and regulators. According to the current regulatory framework, the required immunity of PM and ICD provides a reasonable unperturbed behavior in the presence of cell phones and base stations that use pre-5G technologies. PM/ICD international standards do not consider some peculiar characteristics of 5G technology and some of the 5G technology frequency bands (those above 3 GHz), since these frequencies are considered not to add risks to the AIMD functioning. Here we analyze the theoretical issues about the interference between 5G technology and PM/ICD and propose an experimental approach to perform a measurement campaign.
- 17 May 2023
- Published by Wolters Kluwer Health in Health Physics
- Vol. 125 (3) , 202-206
Pacemakers, Implantable Defibrillators, and 5G Technology: What We Need to Know
Pacemakers (PM) and implantable cardioverter defibrillators (ICD) are active implantable medical devices (AIMD) needed in case of cardiac arrhythmias. Given their potentially life-sustaining nature, the interaction between any source of electromagnetic field and these AIMDs is an ongoing concern of patients, industry, and regulators. According to the current regulatory framework, the required immunity of PM and ICD provides a reasonable unperturbed behavior in the presence of cell phones and base stations that use pre-5G technologies. PM/ICD international standards do not consider some peculiar characteristics of 5G technology and some of the 5G technology frequency bands (those above 3 GHz), since these frequencies are considered not to add risks to the AIMD functioning. Here we analyze the theoretical issues about the interference between 5G technology and PM/ICD and propose an experimental approach to perform a measurement campaign.
- Open Access
- 3 March 2023
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 20 (5) , 4512
5G Service and Pacemakers/Implantable Defibrillators: What Is the Actual Risk?
Rapidly growing worldwide, 5G service is expected to deeply change the way we communicate, connect and share data. It encompasses the whole spectrum of new technology, infrastructure and mobile connectivity, and will touch not only every sector in the industry, but also many aspects of our everyday life. Although the compliance with international regulations provides reasonable protection to public health and safety, there might be specific issues not fully covered by the current technical standards. Among the aspects that shall be carefully considered, there is the potential interference that can be induced on medical devices, and in particular on implantable medical devices that are critical for the patient’s life, such as pacemakers and implantable defibrillators. This study aims to assess the actual risk that 5G communication systems pose to pacemakers and implantable defibrillators. The setup proposed by the ISO 14117 standard was adapted to include 5G characteristic frequencies of 700 MHz and 3.6 GHz. A total number of 384 tests were conducted. Among them, 43 EMI events were observed. Collected results reveal that RF hand-held transmitters operating in these two frequency bands do not pose additional risk compared to pre-5G bands and that the safety distance of 15 cm typically indicted by the PM/ICD manufacturer is still able to guarantee the patient’s safety.
- 3 March 2023
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 20 (5) , 4512
Open Access5G Service and Pacemakers/Implantable Defibrillators: What Is the Actual Risk?
Rapidly growing worldwide, 5G service is expected to deeply change the way we communicate, connect and share data. It encompasses the whole spectrum of new technology, infrastructure and mobile connectivity, and will touch not only every sector in the industry, but also many aspects of our everyday life. Although the compliance with international regulations provides reasonable protection to public health and safety, there might be specific issues not fully covered by the current technical standards. Among the aspects that shall be carefully considered, there is the potential interference that can be induced on medical devices, and in particular on implantable medical devices that are critical for the patient’s life, such as pacemakers and implantable defibrillators. This study aims to assess the actual risk that 5G communication systems pose to pacemakers and implantable defibrillators. The setup proposed by the ISO 14117 standard was adapted to include 5G characteristic frequencies of 700 MHz and 3.6 GHz. A total number of 384 tests were conducted. Among them, 43 EMI events were observed. Collected results reveal that RF hand-held transmitters operating in these two frequency bands do not pose additional risk compared to pre-5G bands and that the safety distance of 15 cm typically indicted by the PM/ICD manufacturer is still able to guarantee the patient’s safety.
- Open Access
- 25 January 2022
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 45 (3) , 410-417
iPhone 12 MagSafe technology and cardiac implantable devices: Assessment of the actual risk
Background: Pacemaker (PM) and implantable cardioverter defibrillators (ICD) are equipped with a magnetic sensor activated by external application of magnets to easily manage some functions of these devices. If activated inadvertently or outside a controlled environment and without the supervision of clinical personnel, this magnetic mode introduces a potential risk. In reality, the possibility of a static magnetic field affecting a PM or ICD is remote. However, the presence of the magnet in the iPhone 12 made the possibility of inadvertently activating the magnetic switch of PM and ICD less remote.Objective: This study investigates the effects of magnetic interference of the iPhone 12 on a large set of cardiac implantable devices representative of the current market and proposes adequate rules of conduct.Methods: We investigated the risk of the magnetic interference of the iPhone 12 and its MagSafe accessories on a comprehensive set of PMs and ICDs, including the subcutaneous ICD. For the first time, the magnetic interference phenomena were correlated with the magnetic field levels measured all around iPhone 12.Results: We discovered that the magnets inside iPhone 12 trigger the magnetic mode in the 12 tested devices up to a distance of 1 cm.Conclusions: Considering the implications related to the activation of the magnetic switch, to date, it is advisable to follow Apple's indications relating to the safety distance of 15 cm, which is widely compatible with the results obtained from this paper and in line with the indications provided by the implantable cardiac device manufacturers.
- 25 January 2022
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 45 (3) , 410-417
Open AccessiPhone 12 MagSafe technology and cardiac implantable devices: Assessment of the actual risk
Background: Pacemaker (PM) and implantable cardioverter defibrillators (ICD) are equipped with a magnetic sensor activated by external application of magnets to easily manage some functions of these devices. If activated inadvertently or outside a controlled environment and without the supervision of clinical personnel, this magnetic mode introduces a potential risk. In reality, the possibility of a static magnetic field affecting a PM or ICD is remote. However, the presence of the magnet in the iPhone 12 made the possibility of inadvertently activating the magnetic switch of PM and ICD less remote.Objective: This study investigates the effects of magnetic interference of the iPhone 12 on a large set of cardiac implantable devices representative of the current market and proposes adequate rules of conduct.Methods: We investigated the risk of the magnetic interference of the iPhone 12 and its MagSafe accessories on a comprehensive set of PMs and ICDs, including the subcutaneous ICD. For the first time, the magnetic interference phenomena were correlated with the magnetic field levels measured all around iPhone 12.Results: We discovered that the magnets inside iPhone 12 trigger the magnetic mode in the 12 tested devices up to a distance of 1 cm.Conclusions: Considering the implications related to the activation of the magnetic switch, to date, it is advisable to follow Apple's indications relating to the safety distance of 15 cm, which is widely compatible with the results obtained from this paper and in line with the indications provided by the implantable cardiac device manufacturers.
- 2 December 2021
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (12) , 1203-1208
Estimate and reporting of longevity for cardiac implantable electronic devices: a proposal for standardized criteria
Cardiac implantable electronic devices (CIEDs) are widely used according to consensus guidelines in various patient categories. The longevity of CIED is a major determinant of the frequency with wh...
- 2 December 2021
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (12) , 1203-1208
Estimate and reporting of longevity for cardiac implantable electronic devices: a proposal for standardized criteria
Cardiac implantable electronic devices (CIEDs) are widely used according to consensus guidelines in various patient categories. The longevity of CIED is a major determinant of the frequency with wh...
- Open Access
- 15 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (18) , 9709
Workers with Cardiac AIMD Exposed to EMF: Methods and Case Studies for Risk Analysis in the Framework of the European Regulations
Workers with cardiac active implantable medical devices (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), are considered by the occupational health and safety regulation framework as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we first describe the general methodology that shall be followed for the risk assessment of employees with a cardiac AIMD exposed to EMF, according to the EU regulation, and in particular to the EN 50527-2-1:2016 and 50527-2-2:2018 standards. Then, three case studies related to specific EMF sources are presented, to better describe how the initial analysis of the risk assessment can be performed in practice, and to understand if a further specific risk assessment analysis is required or not.
- 15 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (18) , 9709
Open AccessWorkers with Cardiac AIMD Exposed to EMF: Methods and Case Studies for Risk Analysis in the Framework of the European Regulations
Workers with cardiac active implantable medical devices (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), are considered by the occupational health and safety regulation framework as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we first describe the general methodology that shall be followed for the risk assessment of employees with a cardiac AIMD exposed to EMF, according to the EU regulation, and in particular to the EN 50527-2-1:2016 and 50527-2-2:2018 standards. Then, three case studies related to specific EMF sources are presented, to better describe how the initial analysis of the risk assessment can be performed in practice, and to understand if a further specific risk assessment analysis is required or not.
- Open Access
- 15 November 2019
- Published by MDPI AG in Environments
- Vol. 6 (11) , 119
Workers with Active Implantable Medical Devices Exposed to EMF: In Vitro Test for the Risk Assessment
The occupational health and safety framework identifies workers with an active implantable medical device (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we describe the results of in vitro testing/measurements performed according to the EN50527-2-1:2016 standard, for the risk assessment of employees with a PM exposed to three EMF sources: (1) An electrosurgical unit (ESU); (2) a transcranial stimulator (TMS); and (3) an arc welder. The ESU did not affect the PM behavior in any of the configurations tested. For the TMS and the arc welder, interference phenomena were observed in limited experimental configurations, corresponding to the maximum magnetic field coupling between the EMF source and the implant. The in vitro measurements presented can be considered an example of how the specific risk assessment for a worker with a PM can be performed, according to one of the methodologies proposed in the EN50527-2-1:2016, and can be used as scientific evidence and literature data for future risk assessments on the same EMF sources.
- 15 November 2019
- Published by MDPI AG in Environments
- Vol. 6 (11) , 119
Open AccessWorkers with Active Implantable Medical Devices Exposed to EMF: In Vitro Test for the Risk Assessment
The occupational health and safety framework identifies workers with an active implantable medical device (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we describe the results of in vitro testing/measurements performed according to the EN50527-2-1:2016 standard, for the risk assessment of employees with a PM exposed to three EMF sources: (1) An electrosurgical unit (ESU); (2) a transcranial stimulator (TMS); and (3) an arc welder. The ESU did not affect the PM behavior in any of the configurations tested. For the TMS and the arc welder, interference phenomena were observed in limited experimental configurations, corresponding to the maximum magnetic field coupling between the EMF source and the implant. The in vitro measurements presented can be considered an example of how the specific risk assessment for a worker with a PM can be performed, according to one of the methodologies proposed in the EN50527-2-1:2016, and can be used as scientific evidence and literature data for future risk assessments on the same EMF sources.
- 25 October 2017
- Published by Springer Nature
- Vol. 1687, 75-89
System Biology Approach: Gene Network Analysis for Muscular Dystrophy
Phenotypic changes at different organization levels from cell to entire organism are associated to changes in the pattern of gene expression. These changes involve the entire genome expression pattern and heavily rely upon correlation patterns among genes. The classical approach used to analyze gene expression data builds upon the application of supervised statistical techniques to detect genes differentially expressed among two or more phenotypes (e.g., normal vs. disease). The use of an a posteriori, unsupervised approach based on principal component analysis (PCA) and the subsequent construction of gene correlation networks can shed a light on unexpected behaviour of gene regulation system while maintaining a more naturalistic view on the studied system. In this chapter we applied an unsupervised method to discriminate DMD patient and controls. The genes having the highest absolute scores in the discrimination between the groups were then analyzed in terms of gene expression networks, on the basis of their mutual correlation in the two groups. The correlation network structures suggest two different modes of gene regulation in the two groups, reminiscent of important aspects of DMD pathogenesis.
- 25 October 2017
- Published by Springer Nature
- Vol. 1687, 75-89
System Biology Approach: Gene Network Analysis for Muscular Dystrophy
Phenotypic changes at different organization levels from cell to entire organism are associated to changes in the pattern of gene expression. These changes involve the entire genome expression pattern and heavily rely upon correlation patterns among genes. The classical approach used to analyze gene expression data builds upon the application of supervised statistical techniques to detect genes differentially expressed among two or more phenotypes (e.g., normal vs. disease). The use of an a posteriori, unsupervised approach based on principal component analysis (PCA) and the subsequent construction of gene correlation networks can shed a light on unexpected behaviour of gene regulation system while maintaining a more naturalistic view on the studied system. In this chapter we applied an unsupervised method to discriminate DMD patient and controls. The genes having the highest absolute scores in the discrimination between the groups were then analyzed in terms of gene expression networks, on the basis of their mutual correlation in the two groups. The correlation network structures suggest two different modes of gene regulation in the two groups, reminiscent of important aspects of DMD pathogenesis.