Shih-Ming Hsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shih-Ming Hsu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Tung-Hsin Wu
Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
2 shared publications C.M. Chou
Health Physics Division, Institute of Nuclear Energy Research, 1000, Wen-Hua Road, Longtan Township, Taoyuan County 32546, Taiwan
1 shared publication- Cheng-Ting Shih
Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan
1 shared publication Chia-Jung Tsai
Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, 155 Li-Nong St., Sec. 2, Taipei 112, Taiwan
1 shared publication- Chuan-Jong Tung
Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Kwei-Shan, Tao-Yuan 333, Taiwan
1 shared publication - Fang-Yuh Hsu
Nuclear Science Technology and Development Center, National Tsing Hua University, Hsinchu, Taiwan
1 shared publication
Latest Publications
- Open Access
- 31 May 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (5) , e37769
Comparison of the Commercial Color LCD and the Medical Monochrome LCD Using Randomized Object Test Patterns
Workstations and electronic display devices in a picture archiving and communication system (PACS) provide a convenient and efficient platform for medical diagnosis. The performance of display devices has to be verified to ensure that image quality is not degraded. In this study, we designed a set of randomized object test patterns (ROTPs) consisting of randomly located spheres with various image characteristics to evaluate the performance of a 2.5 mega-pixel (MP) commercial color LCD and a 3 MP diagnostic monochrome LCD in several aspects, including the contrast, resolution, point spread effect, and noise. The ROTPs were then merged into 120 abdominal CT images. Five radiologists were invited to review the CT images, and receiver operating characteristic (ROC) analysis was carried out using a five-point rating scale. In the high background patterns of ROTPs, the sensitivity performance was comparable between both monitors in terms of contrast and resolution, whereas, in the low background patterns, the performance of the commercial color LCD was significantly poorer than that of the diagnostic monochrome LCD in all aspects. The average area under the ROC curve (AUC) for reviewing abdominal CT images was 0.717±0.0200 and 0.740±0.0195 for the color monitor and the diagnostic monitor, respectively. The observation time (OT) was 145±27.6 min and 127±19.3 min, respectively. No significant differences appeared in AUC (p = 0.265) and OT (p = 0.07). The overall results indicate that ROTPs can be implemented as a quality control tool to evaluate the intrinsic characteristics of display devices. Although there is still a gap in technology between different types of LCDs, commercial color LCDs could replace diagnostic monochrome LCDs as a platform for reviewing abdominal CT images after monitor calibration.
- 31 May 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (5) , e37769
Open AccessComparison of the Commercial Color LCD and the Medical Monochrome LCD Using Randomized Object Test Patterns
Workstations and electronic display devices in a picture archiving and communication system (PACS) provide a convenient and efficient platform for medical diagnosis. The performance of display devices has to be verified to ensure that image quality is not degraded. In this study, we designed a set of randomized object test patterns (ROTPs) consisting of randomly located spheres with various image characteristics to evaluate the performance of a 2.5 mega-pixel (MP) commercial color LCD and a 3 MP diagnostic monochrome LCD in several aspects, including the contrast, resolution, point spread effect, and noise. The ROTPs were then merged into 120 abdominal CT images. Five radiologists were invited to review the CT images, and receiver operating characteristic (ROC) analysis was carried out using a five-point rating scale. In the high background patterns of ROTPs, the sensitivity performance was comparable between both monitors in terms of contrast and resolution, whereas, in the low background patterns, the performance of the commercial color LCD was significantly poorer than that of the diagnostic monochrome LCD in all aspects. The average area under the ROC curve (AUC) for reviewing abdominal CT images was 0.717±0.0200 and 0.740±0.0195 for the color monitor and the diagnostic monitor, respectively. The observation time (OT) was 145±27.6 min and 127±19.3 min, respectively. No significant differences appeared in AUC (p = 0.265) and OT (p = 0.07). The overall results indicate that ROTPs can be implemented as a quality control tool to evaluate the intrinsic characteristics of display devices. Although there is still a gap in technology between different types of LCDs, commercial color LCDs could replace diagnostic monochrome LCDs as a platform for reviewing abdominal CT images after monitor calibration.
- 1 March 2012
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 70 (3) , 456-461
Ambient and personal dose assessment of a container inspection site using a mobile X-ray system
- 1 March 2012
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 70 (3) , 456-461
Ambient and personal dose assessment of a container inspection site using a mobile X-ray system
- 1 October 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 652 (1) , 771-774
Evaluation of radiation dose of triple rule-out coronary angiography protocols with different scan length using 256-slice CT
- 1 October 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 652 (1) , 771-774
Evaluation of radiation dose of triple rule-out coronary angiography protocols with different scan length using 256-slice CT
- 16 April 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 146 (1-3) , 100-102
Air kerma standard and measurement comparison on source strength determination for high-dose rate 192Ir brachytherapy in Taiwan
This paper describes the establishment by the Institute of Nuclear Energy Research (INER, Taiwan) of the reference air kerma rate (RAKR) calibration standard for measurement of high-dose rate (HDR) 192Ir brachytherapy source strength. A bilateral comparison has been made in the RAKR standards for HDR 192Ir brachytherapy sources at the INER and Physikalisch-Technische Bundesanstalt (PTB, Germany) and the measurement difference was within the overall standard uncertainty and showed good agreement between the two calibration standard systems established at the INER and the PTB. Besides, INER also worked with 20 domestic hospitals to organise an on-site measurement comparison programme to explore the status of HDR 192Ir brachytherapy source strength determination in Taiwan. The comparison results presented the ratios of RAKR with vendor values, as determined by INER and hospitals from the programme. The ratios fall in all cases within the ±3 % guaranteed by the vendors for a coverage factor of k=2 or at 95 % confidence level.
- 16 April 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 146 (1-3) , 100-102
Air kerma standard and measurement comparison on source strength determination for high-dose rate 192Ir brachytherapy in Taiwan
This paper describes the establishment by the Institute of Nuclear Energy Research (INER, Taiwan) of the reference air kerma rate (RAKR) calibration standard for measurement of high-dose rate (HDR) 192Ir brachytherapy source strength. A bilateral comparison has been made in the RAKR standards for HDR 192Ir brachytherapy sources at the INER and Physikalisch-Technische Bundesanstalt (PTB, Germany) and the measurement difference was within the overall standard uncertainty and showed good agreement between the two calibration standard systems established at the INER and the PTB. Besides, INER also worked with 20 domestic hospitals to organise an on-site measurement comparison programme to explore the status of HDR 192Ir brachytherapy source strength determination in Taiwan. The comparison results presented the ratios of RAKR with vendor values, as determined by INER and hospitals from the programme. The ratios fall in all cases within the ±3 % guaranteed by the vendors for a coverage factor of k=2 or at 95 % confidence level.
- 31 July 2010
- Published by Elsevier in Radiation Measurements
- Vol. 45 (3-6) , 704-706
Performance testing and dose verification for extremity ring dosimetry
- 31 July 2010
- Published by Elsevier in Radiation Measurements
- Vol. 45 (3-6) , 704-706
Performance testing and dose verification for extremity ring dosimetry