Chuan-Jong Tung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chuan-Jong Tung has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Tsi-Chian Chao
Chang Gung Univ. (Taiwan)
10 shared publications - Chung-Chi Lee
Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Kwei-Shan, Tao-Yuan 333, Taiwan
6 shared publications Ji-Hong Hong
Department of Radiation Oncology, Chang Gung Memorial Hospital, Guishan, Taoyuan 333, Taiwan
3 shared publicationsPei-Chieh Yu
3 shared publications- Cher Ming Tan
Chang Gung University
2 shared publications Ching-Jung Wu
2 shared publications
Latest Publications
- Open Access
- 26 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1113
Lineal Energy of Proton in Silicon by a Microdosimetry Simulation
Single event upset, or Single Event Effect (SEE) is increasingly important as semiconductor devices are entering into nano-meter scale. The Linear Energy Transfer (LET) concept is commonly used to estimate the rate of SEE. The SEE, however, should be related to energy deposition of each stochastic event, but not LET which is a non-stochastic quantity. Instead, microdosimetry, which uses a lineal calculation of energy lost per step for each specific track, should be used to replace LET to predict microelectronic failure from SEEs. Monte Carlo simulation is used for the demonstration, and there are several parameters needed to optimise for SEE simulation, such as the target size, physical models and scoring techniques. We also show the thickness of the sensitive volume, which also correspond to the size of a device, will change the spectra of lineal energy. With a more comprehensive Monte Carlo simulation performed in this work, we also show and explain the differences in our results and the reported results such as those from Hiemstra et al. which are commonly used in semiconductor industry for the prediction of SEE in devices.
- 26 January 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1113
Open AccessLineal Energy of Proton in Silicon by a Microdosimetry Simulation
Single event upset, or Single Event Effect (SEE) is increasingly important as semiconductor devices are entering into nano-meter scale. The Linear Energy Transfer (LET) concept is commonly used to estimate the rate of SEE. The SEE, however, should be related to energy deposition of each stochastic event, but not LET which is a non-stochastic quantity. Instead, microdosimetry, which uses a lineal calculation of energy lost per step for each specific track, should be used to replace LET to predict microelectronic failure from SEEs. Monte Carlo simulation is used for the demonstration, and there are several parameters needed to optimise for SEE simulation, such as the target size, physical models and scoring techniques. We also show the thickness of the sensitive volume, which also correspond to the size of a device, will change the spectra of lineal energy. With a more comprehensive Monte Carlo simulation performed in this work, we also show and explain the differences in our results and the reported results such as those from Hiemstra et al. which are commonly used in semiconductor industry for the prediction of SEE in devices.
- 1 January 2021
- Published by Elsevier in Physica Medica
- Vol. 81, 185-190
MOSFET dose measurements for proton SOBP beam
- 1 January 2021
- Published by Elsevier in Physica Medica
- Vol. 81, 185-190
MOSFET dose measurements for proton SOBP beam
- 1 December 2020
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 225, 106443
Assessment of resident doses near nuclear power plants in Taiwan for epidemiology study
- 1 December 2020
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 225, 106443
Assessment of resident doses near nuclear power plants in Taiwan for epidemiology study
- Open Access
- 6 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3234
Investigate the Equivalence of Neutrons and Protons in Single Event Effects Testing: A Geant4 Study
Neutron radiation on advanced integrated circuits (ICs) is becoming important for their reliable operation. However, a neutron test on ICs is expensive and time-consuming. In this work, we employ Monte Carlo simulation to examine if a proton test can replace or even accelerate the neutron test, and we found that 200 MeV protons are the closest to resembling neutron radiation with five main differences. This 200 MeV concur with the suggestion from National Aeronautics and Space Administration (NASA, Washington, DC, USA). However, the impacts of the five differences on single event effects (SEEs) require future work for examination.
- 6 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3234
Open AccessInvestigate the Equivalence of Neutrons and Protons in Single Event Effects Testing: A Geant4 Study
Neutron radiation on advanced integrated circuits (ICs) is becoming important for their reliable operation. However, a neutron test on ICs is expensive and time-consuming. In this work, we employ Monte Carlo simulation to examine if a proton test can replace or even accelerate the neutron test, and we found that 200 MeV protons are the closest to resembling neutron radiation with five main differences. This 200 MeV concur with the suggestion from National Aeronautics and Space Administration (NASA, Washington, DC, USA). However, the impacts of the five differences on single event effects (SEEs) require future work for examination.
- 1 November 2018
- Published by Elsevier in Radiation Measurements
- Vol. 118, 67-71
GNP enhanced responses in microdosimetric spectra for 192Ir source
- 1 November 2018
- Published by Elsevier in Radiation Measurements
- Vol. 118, 67-71
GNP enhanced responses in microdosimetric spectra for 192Ir source
- 1 October 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 140, 193-200
A Monte Carlo study of bone-tissue interface microdosimeters
- 1 October 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 140, 193-200
A Monte Carlo study of bone-tissue interface microdosimeters
- 1 August 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 137, 169-172
Comparisons of longitudinal and lateral dose profiles and relative biological effectiveness for DNA double strand breaks among 1H, 4He and 12C beams
- 1 August 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 137, 169-172
Comparisons of longitudinal and lateral dose profiles and relative biological effectiveness for DNA double strand breaks among 1H, 4He and 12C beams
- 1 March 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 97, 101-105
Microdosimetry spectra and relative biological effectiveness of 15 and 30 MeV proton beams
- 1 March 2015
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 97, 101-105
Microdosimetry spectra and relative biological effectiveness of 15 and 30 MeV proton beams
- 1 March 2012
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 70 (3) , 456-461
Ambient and personal dose assessment of a container inspection site using a mobile X-ray system
- 1 March 2012
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 70 (3) , 456-461
Ambient and personal dose assessment of a container inspection site using a mobile X-ray system
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 2003-2005
Monte Carlo simulation of small field electron beams for small animal irradiation
- 1 December 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 2003-2005
Monte Carlo simulation of small field electron beams for small animal irradiation