Keding Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Keding Cheng has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Angela Sloan
National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
11 shared publicationsStuart McCorrister
National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, MB, Canada
7 shared publications- Gehua Wang
National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, MB, Canada
6 shared publications Celine Nadon
National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, MB, Canada Department of Medical Microbiology, College of Medicine, University of Manitoba, Winnipeg, MB, Canada
5 shared publicationsGehua Wang
National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Manitoba, Canada
5 shared publicationsHuixia Chui
Henan Center of Disease Control and Prevention, Zhengzhou, Henan Province, China
5 shared publications
Latest Publications
- 1 May 2018
- Published by Elsevier in Journal of Proteomics
- Vol. 180, 36-40
Mass spectrometry-based Shiga toxin identification: An optimized approach
- 1 May 2018
- Published by Elsevier in Journal of Proteomics
- Vol. 180, 36-40
Mass spectrometry-based Shiga toxin identification: An optimized approach
- Open Access
- 1 March 2018
- Published by Elsevier in Protein Expression and Purification
- Vol. 143, 20-27
Altered rPrP substrate structures and their influence on real-time quaking induced conversion reactions
- 1 March 2018
- Published by Elsevier in Protein Expression and Purification
- Vol. 143, 20-27
Open AccessAltered rPrP substrate structures and their influence on real-time quaking induced conversion reactions
- 1 October 2017
- Published by Elsevier in Clinica Chimica Acta
- Vol. 473, 180-185
Traditional approaches versus mass spectrometry in bacterial identification and typing
- 1 October 2017
- Published by Elsevier in Clinica Chimica Acta
- Vol. 473, 180-185
Traditional approaches versus mass spectrometry in bacterial identification and typing
- Open Access
- 1 August 2016
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 54 (8) , 2162-2168
Phenotypic H-Antigen Typing by Mass Spectrometry Combined with Genetic Typing of H Antigens, O Antigens, and Toxins by Whole-Genome Sequencing Enhances Identification of Escherichia coli Isolates
Mass spectrometry-based phenotypic H-antigen typing (MS-H) combined with whole-genome-sequencing-based genetic identification of H antigens, O antigens, and toxins (WGS-HOT) was used to type 60 clinicalEscherichia coliisolates, 43 of which were previously identified as nonmotile, H type undetermined, or O rough by serotyping or having shown discordant MS-H and serotyping results. Whole-genome sequencing confirmed that MS-H was able to provide more accurate data regarding H antigen expression than serotyping. Further, enhanced and more confident O antigen identification resulted from gene cluster based typing in combination with conventional typing based on the gene pair comprisingwzxandwzyand that comprisingwzmandwzt. The O antigen was identified in 94.6% of the isolates when the two genetic O typing approaches (gene pair and gene cluster) were used in conjunction, in comparison to 78.6% when the gene pair database was used alone. In addition, 98.2% of the isolates showed the existence of genes for various toxins and/or virulence factors, among which verotoxins (Shiga toxin 1 and/or Shiga toxin 2) were 100% concordant with conventional PCR based testing results. With more applications of mass spectrometry and whole-genome sequencing in clinical microbiology laboratories, this combined phenotypic and genetic typing platform (MS-H plus WGS-HOT) should be ideal for pathogenicE. colityping.
- 1 August 2016
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 54 (8) , 2162-2168
Open AccessPhenotypic H-Antigen Typing by Mass Spectrometry Combined with Genetic Typing of H Antigens, O Antigens, and Toxins by Whole-Genome Sequencing Enhances Identification of Escherichia coli Isolates
Mass spectrometry-based phenotypic H-antigen typing (MS-H) combined with whole-genome-sequencing-based genetic identification of H antigens, O antigens, and toxins (WGS-HOT) was used to type 60 clinicalEscherichia coliisolates, 43 of which were previously identified as nonmotile, H type undetermined, or O rough by serotyping or having shown discordant MS-H and serotyping results. Whole-genome sequencing confirmed that MS-H was able to provide more accurate data regarding H antigen expression than serotyping. Further, enhanced and more confident O antigen identification resulted from gene cluster based typing in combination with conventional typing based on the gene pair comprisingwzxandwzyand that comprisingwzmandwzt. The O antigen was identified in 94.6% of the isolates when the two genetic O typing approaches (gene pair and gene cluster) were used in conjunction, in comparison to 78.6% when the gene pair database was used alone. In addition, 98.2% of the isolates showed the existence of genes for various toxins and/or virulence factors, among which verotoxins (Shiga toxin 1 and/or Shiga toxin 2) were 100% concordant with conventional PCR based testing results. With more applications of mass spectrometry and whole-genome sequencing in clinical microbiology laboratories, this combined phenotypic and genetic typing platform (MS-H plus WGS-HOT) should be ideal for pathogenicE. colityping.
- Open Access
- 1 July 2016
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 54 (7) , 1751-1754
Endpoint Quaking-Induced Conversion: a Sensitive, Specific, and High-Throughput Method for Antemortem Diagnosis of Creutzfeldt-Jacob Disease
The Prion Laboratory Section of the Public Health Agency of Canada supports heath care professionals dealing with patients suspected to have Creutzfeldt-Jakob disease (CJD) by testing cerebrospinal fluid (CSF) for protein markers of CJD. To better serve Canadian diagnostic requirements, a quaking-induced conversion (QuIC)-based assay has been added to the test panel. The QuIC tests exploit the ability of disease-associated prion protein, found in the CSF of a majority of CJD patients, to convert a recombinant prion protein (rPrP) into detectable amounts of a misfolded, aggregated form of rPrP. The rPrP aggregates interact with a specific dye, causing a measurable change in the dye's fluorescence emission spectrum. Optimal test and analysis parameters were empirically determined. Taking both practical and performance considerations into account, an endpoint QuIC (EP-QuIC) configuration was chosen. EP-QuIC uses a thermo-mixer to perform the shaking necessary to produce the quaking-induced conversions. Fluorescence readings are obtained from a microwell fluorescence reader only at the beginning and the end of EP-QuIC reactions. Samples for which the relative fluorescence unit ratio between the initial and final readings represent a ≥4 increase in signal intensity in at least two of the three replicates are classified as positive. A retrospective analysis of 91 CSF samples that included 45 confirmed cases of CJD and 46 non-CJD cases was used to estimate the performance characteristics of the EP-QuIC assay. The diagnostic sensitivity and specificity of the EP-QuIC test of this set of samples were 98 and 91%, respectively.
- 1 July 2016
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 54 (7) , 1751-1754
Open AccessEndpoint Quaking-Induced Conversion: a Sensitive, Specific, and High-Throughput Method for Antemortem Diagnosis of Creutzfeldt-Jacob Disease
The Prion Laboratory Section of the Public Health Agency of Canada supports heath care professionals dealing with patients suspected to have Creutzfeldt-Jakob disease (CJD) by testing cerebrospinal fluid (CSF) for protein markers of CJD. To better serve Canadian diagnostic requirements, a quaking-induced conversion (QuIC)-based assay has been added to the test panel. The QuIC tests exploit the ability of disease-associated prion protein, found in the CSF of a majority of CJD patients, to convert a recombinant prion protein (rPrP) into detectable amounts of a misfolded, aggregated form of rPrP. The rPrP aggregates interact with a specific dye, causing a measurable change in the dye's fluorescence emission spectrum. Optimal test and analysis parameters were empirically determined. Taking both practical and performance considerations into account, an endpoint QuIC (EP-QuIC) configuration was chosen. EP-QuIC uses a thermo-mixer to perform the shaking necessary to produce the quaking-induced conversions. Fluorescence readings are obtained from a microwell fluorescence reader only at the beginning and the end of EP-QuIC reactions. Samples for which the relative fluorescence unit ratio between the initial and final readings represent a ≥4 increase in signal intensity in at least two of the three replicates are classified as positive. A retrospective analysis of 91 CSF samples that included 45 confirmed cases of CJD and 46 non-CJD cases was used to estimate the performance characteristics of the EP-QuIC assay. The diagnostic sensitivity and specificity of the EP-QuIC test of this set of samples were 98 and 91%, respectively.
- Open Access
- 1 June 2016
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 62 (6) , 839-847
Mass Spectrometry–Based Escherichia coli H Antigen/Flagella Typing: Validation and Comparison with Traditional Serotyping
BACKGROUND: Escherichia coli H antigen typing with antisera, a useful method for flagella clinical identification and classification, is a time-consuming process because of the need to induce flagella growth and the occurrence of undetermined strains. We developed an alternative rapid and analytically sensitive mass spectrometry (MS) method, termed MS-based H antigen typing (MS-H), and applied it at the protein sequence level for H antigen typing. We also performed a comparison with traditional serotyping on reference strains and clinical isolates.METHODS: On the basis of international guidelines, the analytical selectivity and sensitivity, imprecision, correlation, repeatability, and reproducibility of the MS-H platform was evaluated using reference strains. Comparison of MS-H typing and serotyping was performed using 302 clinical isolates from 5 Canadian provinces, and discrepant results between the 2 platforms were resolved through whole genome sequencing.RESULTS: Repeated tests on reference strain EDL933 demonstrated a lower limit of the measuring interval at the subsingle colony (16.97 μg or 1.465 × 107 cells) level and close correlation (r2 > 0.99) between cell culture biomass and sequence coverage. The CV was <10.0% among multiple repeats with 4 reference strains. Intra- and interlaboratory tests demonstrated that the MS-H method was robust and reproducible under various sample preparation and instrumentation conditions. Using discrepancy analysis via whole genome sequencing, performed on isolates with discrepant results, MS-H accurately identified 12.3% more isolates than conventional serotyping.CONCLUSIONS: MS-H typing of E. coli is useful for fast and accurate flagella typing and could be very useful during E. coli outbreaks.
- 1 June 2016
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 62 (6) , 839-847
Open AccessMass Spectrometry–Based Escherichia coli H Antigen/Flagella Typing: Validation and Comparison with Traditional Serotyping
BACKGROUND: Escherichia coli H antigen typing with antisera, a useful method for flagella clinical identification and classification, is a time-consuming process because of the need to induce flagella growth and the occurrence of undetermined strains. We developed an alternative rapid and analytically sensitive mass spectrometry (MS) method, termed MS-based H antigen typing (MS-H), and applied it at the protein sequence level for H antigen typing. We also performed a comparison with traditional serotyping on reference strains and clinical isolates.METHODS: On the basis of international guidelines, the analytical selectivity and sensitivity, imprecision, correlation, repeatability, and reproducibility of the MS-H platform was evaluated using reference strains. Comparison of MS-H typing and serotyping was performed using 302 clinical isolates from 5 Canadian provinces, and discrepant results between the 2 platforms were resolved through whole genome sequencing.RESULTS: Repeated tests on reference strain EDL933 demonstrated a lower limit of the measuring interval at the subsingle colony (16.97 μg or 1.465 × 107 cells) level and close correlation (r2 > 0.99) between cell culture biomass and sequence coverage. The CV was <10.0% among multiple repeats with 4 reference strains. Intra- and interlaboratory tests demonstrated that the MS-H method was robust and reproducible under various sample preparation and instrumentation conditions. Using discrepancy analysis via whole genome sequencing, performed on isolates with discrepant results, MS-H accurately identified 12.3% more isolates than conventional serotyping.CONCLUSIONS: MS-H typing of E. coli is useful for fast and accurate flagella typing and could be very useful during E. coli outbreaks.
- Open Access
- 2 February 2016
- Published by Wiley in Proteomics – Clinical Applications
- Vol. 10 (4) , 346-357
Recent development of mass spectrometry and proteomics applications in identification and typing of bacteria
Identification and typing of bacteria occupy a large fraction of time and work in clinical microbiology laboratories. With the certification of some MS platforms in recent years, more applications and tests of MS‐based diagnosis methods for bacteria identification and typing have been created, not only on well‐accepted MALDI‐TOF‐MS‐based fingerprint matches, but also on solving the insufficiencies of MALDI‐TOF‐MS‐based platforms and advancing the technology to areas such as targeted MS identification and typing of bacteria, bacterial toxin identification, antibiotics susceptibility/resistance tests, and MS‐based diagnostic method development on unique bacteria such as Clostridium and Mycobacteria. This review summarizes the recent development in MS platforms and applications in bacteria identification and typing of common pathogenic bacteria.
- 2 February 2016
- Published by Wiley in Proteomics – Clinical Applications
- Vol. 10 (4) , 346-357
Open AccessRecent development of mass spectrometry and proteomics applications in identification and typing of bacteria
Identification and typing of bacteria occupy a large fraction of time and work in clinical microbiology laboratories. With the certification of some MS platforms in recent years, more applications and tests of MS‐based diagnosis methods for bacteria identification and typing have been created, not only on well‐accepted MALDI‐TOF‐MS‐based fingerprint matches, but also on solving the insufficiencies of MALDI‐TOF‐MS‐based platforms and advancing the technology to areas such as targeted MS identification and typing of bacteria, bacterial toxin identification, antibiotics susceptibility/resistance tests, and MS‐based diagnostic method development on unique bacteria such as Clostridium and Mycobacteria. This review summarizes the recent development in MS platforms and applications in bacteria identification and typing of common pathogenic bacteria.
- Open Access
- 1 August 2015
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 53 (8) , 2480-2485
Rapid, Sensitive, and Specific Escherichia coli H Antigen Typing by Matrix-Assisted Laser Desorption Ionization–Time of Flight-Based Peptide Mass Fingerprinting
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has gained popularity in recent years for rapid bacterial identification, mostly at the genus or species level. In this study, a rapid method to identify theEscherichia coliflagellar antigen (H antigen) at the subspecies level was developed using a MALDI-TOF MS platform with high specificity and sensitivity. Flagella were trapped on a filter membrane, and on-filter trypsin digestion was performed. The tryptic digests of each flagellin then were collected and analyzed by MALDI-TOF MS through peptide mass fingerprinting. Sixty-one reference strains containing all 53 H types and 85 clinical strains were tested and compared to serotyping designations. Whole-genome sequencing was used to resolve conflicting results between the two methods. It was found that DHB (2,5-dihydroxybenzoic acid) worked better than CHCA (α-cyano-4-hydroxycinnamic acid) as the matrix for MALDI-TOF MS, with higher confidence during protein identification. After method optimization, reference strains representing all 53E. coliH types were identified correctly by MALDI-TOF MS. A customE. coliflagellar/H antigen database was crucial for clearly identifying theE. coliH antigens. Of 85 clinical isolates tested by MALDI-TOF MS-H, 75 identified MS-H types (88.2%) matched results obtained from traditional serotyping. Among 10 isolates where the results of MALDI-TOF MS-H and serotyping did not agree, 60% of H types characterized by whole-genome sequencing agreed with those identified by MALDI-TOF MS-H, compared to only 20% by serotyping. This MALDI-TOF MS-H platform can be used for rapid and cost-effectiveE. coliH antigen identification, especially duringE. colioutbreaks.
- 1 August 2015
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 53 (8) , 2480-2485
Open AccessRapid, Sensitive, and Specific Escherichia coli H Antigen Typing by Matrix-Assisted Laser Desorption Ionization–Time of Flight-Based Peptide Mass Fingerprinting
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has gained popularity in recent years for rapid bacterial identification, mostly at the genus or species level. In this study, a rapid method to identify theEscherichia coliflagellar antigen (H antigen) at the subspecies level was developed using a MALDI-TOF MS platform with high specificity and sensitivity. Flagella were trapped on a filter membrane, and on-filter trypsin digestion was performed. The tryptic digests of each flagellin then were collected and analyzed by MALDI-TOF MS through peptide mass fingerprinting. Sixty-one reference strains containing all 53 H types and 85 clinical strains were tested and compared to serotyping designations. Whole-genome sequencing was used to resolve conflicting results between the two methods. It was found that DHB (2,5-dihydroxybenzoic acid) worked better than CHCA (α-cyano-4-hydroxycinnamic acid) as the matrix for MALDI-TOF MS, with higher confidence during protein identification. After method optimization, reference strains representing all 53E. coliH types were identified correctly by MALDI-TOF MS. A customE. coliflagellar/H antigen database was crucial for clearly identifying theE. coliH antigens. Of 85 clinical isolates tested by MALDI-TOF MS-H, 75 identified MS-H types (88.2%) matched results obtained from traditional serotyping. Among 10 isolates where the results of MALDI-TOF MS-H and serotyping did not agree, 60% of H types characterized by whole-genome sequencing agreed with those identified by MALDI-TOF MS-H, compared to only 20% by serotyping. This MALDI-TOF MS-H platform can be used for rapid and cost-effectiveE. coliH antigen identification, especially duringE. colioutbreaks.
- 30 October 2014
- Published by Wiley in Proteomics – Clinical Applications
- Vol. 8 (11-12) , 963-970
Quality evaluation of LC‐MS/MS‐based E. coli H antigen typing (MS‐H) through label‐free quantitative data analysis in a clinical sample setup
Purpose: The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS‐H, a method originally developed for rapid H antigen typing of E. coli using LC‐MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation.Experimental design: Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC‐MS/MS batch run procedures and MS‐H typing rules were compared and summarized through quantitative analysis of MS‐H data output for a standard method development.Results: Label‐free quantitative data analysis of MS‐H typing was proven very useful for examining the quality of MS‐H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS‐H typing was established and validated.Conclusions and clinical relevance: With LC‐MS/MS batch run procedure and database search parameter unique for E. coli MS‐H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established.
- 30 October 2014
- Published by Wiley in Proteomics – Clinical Applications
- Vol. 8 (11-12) , 963-970
Quality evaluation of LC‐MS/MS‐based E. coli H antigen typing (MS‐H) through label‐free quantitative data analysis in a clinical sample setup
Purpose: The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS‐H, a method originally developed for rapid H antigen typing of E. coli using LC‐MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation.Experimental design: Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC‐MS/MS batch run procedures and MS‐H typing rules were compared and summarized through quantitative analysis of MS‐H data output for a standard method development.Results: Label‐free quantitative data analysis of MS‐H typing was proven very useful for examining the quality of MS‐H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS‐H typing was established and validated.Conclusions and clinical relevance: With LC‐MS/MS batch run procedure and database search parameter unique for E. coli MS‐H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established.
- Open Access
- 10 July 2014
- Published by Springer Nature in BMC Research Notes
- Vol. 7 (1) , 444
Fit-for-purpose curated database application in mass spectrometry-based targeted protein identification and validation
Mass spectrometry (MS) is a very sensitive and specific method for protein identification, biomarker discovery, and biomarker validation. Protein identification is commonly carried out by comparing MS data with public databases. However, with the development of high throughput and accurate genomic sequencing technology, public databases are being overwhelmed with new entries from different species every day. The application of these databases can also be problematic due to factors such as size, specificity, and unharmonized annotation of the molecules of interest. Current databases representing liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based searches focus on enzyme digestion patterns and sequence information and consequently, important functional information can be missed within the search output. Protein variants displaying similar sequence homology can interfere with database identification when only certain homologues are examined. In addition, recombinant DNA technology can result in products that may not be accurately annotated in public databases. Curated databases, which focus on the molecule of interest with clearer functional annotation and sequence information, are necessary for accurate protein identification and validation. Here, four cases of curated database application have been explored and summarized.
- 10 July 2014
- Published by Springer Nature in BMC Research Notes
- Vol. 7 (1) , 444
Open AccessFit-for-purpose curated database application in mass spectrometry-based targeted protein identification and validation
Mass spectrometry (MS) is a very sensitive and specific method for protein identification, biomarker discovery, and biomarker validation. Protein identification is commonly carried out by comparing MS data with public databases. However, with the development of high throughput and accurate genomic sequencing technology, public databases are being overwhelmed with new entries from different species every day. The application of these databases can also be problematic due to factors such as size, specificity, and unharmonized annotation of the molecules of interest. Current databases representing liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based searches focus on enzyme digestion patterns and sequence information and consequently, important functional information can be missed within the search output. Protein variants displaying similar sequence homology can interfere with database identification when only certain homologues are examined. In addition, recombinant DNA technology can result in products that may not be accurately annotated in public databases. Curated databases, which focus on the molecule of interest with clearer functional annotation and sequence information, are necessary for accurate protein identification and validation. Here, four cases of curated database application have been explored and summarized.