Mikko Taina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mikko Taina has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Marja Hedman
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland Heart Center, Kuopio University Hospital, Kuopio, Finland
5 shared publicationsPekka Jäkälä
Unit of Neurology, Institute of Clinical Medicine, University of Eastern Finland, Kuopio, Finland NeuroCenter, Kuopio University Hospital, Kuopio, Finland
5 shared publicationsRitva Vanninen
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland Unit of Radiology, Institute of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
5 shared publicationsAntti Muuronen
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland Unit of Radiology, Institute of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
3 shared publicationsPetri Sipola
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; Unit of Radiology, Institute of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
3 shared publications- Petri Sipola
Department of Clinical Radiology, University of Eastern Finland and Kuopio University Hospital, Kuopio, Finland
2 shared publications
Latest Publications
- 28 August 2016
- Vol. 30 (5) , 671-6
Cardiac CT Differentiates Left Atrial Appendage Thrombi from Circulatory Stasis in Acute Stroke Patients.
The left atrial appendage (LAA) is the most typical origin for a cardioembolic thrombusins' stroke etiology. Although transesophageal echocardiography (TEE) is widely used, this technique encounters difficulties in differentiating solid thrombus from circulatory stasis/spontaneous echo contrast (SEC). We assessed whether cardiac computed tomography (cCT) could more accurately detect LAA thrombi. A total of 102 patients with suspected acute cardioembolic stroke/ transient ischemic attack (TIA) without chronic atrial fibrillation underwent arterial and venous phase cCT and TEE. TEE and cCT were consensus read to define LAA thrombus, while TEE alone was used to determine SEC. The LAA/aorta Houndsfield unit (HU) ratio was measured in both phases independently and blinded to prior visual readings. The optimal LAA/aorta HU ratio cut-off value for differentiating thrombi and SEC was estimated. TEE indicated 10 SECs and three thrombi. Consensus reading of cCT and TEE indicated that all thrombi detected in TEE were false-positive but revealed three actual thrombi missed in TEE. The LAA/aorta HU ratio correlated significantly with the presence of SEC both in arterial (p=0.019) and venous phases (p=0.024) and with the presence of thrombi in both phases (p0.245 and 0.245 and <0.824 in the venous phase. Values of sensitivity, specificity, positive and negative predictive value and accuracy for detection of thrombi were 100% for cCT in both phases. cCT is more accurate than TEE in the detection of LAA thrombi, especially when combined with the measurement of LAA/aorta HU ratio.
- 28 August 2016
- Vol. 30 (5) , 671-6
Cardiac CT Differentiates Left Atrial Appendage Thrombi from Circulatory Stasis in Acute Stroke Patients.
The left atrial appendage (LAA) is the most typical origin for a cardioembolic thrombusins' stroke etiology. Although transesophageal echocardiography (TEE) is widely used, this technique encounters difficulties in differentiating solid thrombus from circulatory stasis/spontaneous echo contrast (SEC). We assessed whether cardiac computed tomography (cCT) could more accurately detect LAA thrombi. A total of 102 patients with suspected acute cardioembolic stroke/ transient ischemic attack (TIA) without chronic atrial fibrillation underwent arterial and venous phase cCT and TEE. TEE and cCT were consensus read to define LAA thrombus, while TEE alone was used to determine SEC. The LAA/aorta Houndsfield unit (HU) ratio was measured in both phases independently and blinded to prior visual readings. The optimal LAA/aorta HU ratio cut-off value for differentiating thrombi and SEC was estimated. TEE indicated 10 SECs and three thrombi. Consensus reading of cCT and TEE indicated that all thrombi detected in TEE were false-positive but revealed three actual thrombi missed in TEE. The LAA/aorta HU ratio correlated significantly with the presence of SEC both in arterial (p=0.019) and venous phases (p=0.024) and with the presence of thrombi in both phases (p0.245 and 0.245 and <0.824 in the venous phase. Values of sensitivity, specificity, positive and negative predictive value and accuracy for detection of thrombi were 100% for cCT in both phases. cCT is more accurate than TEE in the detection of LAA thrombi, especially when combined with the measurement of LAA/aorta HU ratio.
- 25 April 2016
- Published by Springer Nature in European Radiology
- Vol. 26 (12) , 4361-4370
Incidentally detected enhancing lesions found in breast MRI: analysis of apparent diffusion coefficient and T2 signal intensity significantly improves specificity
Objectives To evaluate the value of adding T2- and diffusion-weighted imaging (DWI) to the BI-RADS® classification in MRI-detected lesions. Methods This retrospective study included 112 consecutive patients who underwent 3.0T structural breast MRI with T2- and DWI on the basis of EUSOMA recommendations. Morphological and kinetic features, T2 signal intensity (T2 SI) and apparent diffusion coefficient (ADC) findings were assessed. Results Thirty-three (29.5 %) patients (mean age 57.0 ± 12.7 years) had 36 primarily MRI-detected incidental lesions of which 16 (44.4 %) proved to be malignant. No single morphological or kinetic feature was associated with malignancy. Both low T2 SI (P = 0.009) and low ADC values (≤0.87 × 10−3 mm2s−1, P < 0.001) yielded high specificity (80.0 %/80.0 %). The BI-RADS classification supplemented with information from DWI and T2-WI improved the diagnostic performance of the BI-RADS classification as sensitivity remained 100 % and specificity improved from 30 % to 65.0 %. The numbers of false positive lesions declined from 39 % (N = 14) to 19 % (N = 7). Conclusion MRI-detected incidental lesions may be challenging to characterize as they have few specific malignancy indicating features. The specificity of MRI can be improved by incorporating T2 SI and ADC values into the BI-RADS assessment. Key Points • MRI-detected incidental lesions have few specific malignancy indicating features. • ≥ 1 suspicious morphologic or kinetic feature may warrant biopsy. • T2 signal intensity and DWI assessment are feasible in primarily MRI-detected lesions. • T2 SI and DWI assessment improve the BI-RADS specificity in MRI-detected lesions.
- 25 April 2016
- Published by Springer Nature in European Radiology
- Vol. 26 (12) , 4361-4370
Incidentally detected enhancing lesions found in breast MRI: analysis of apparent diffusion coefficient and T2 signal intensity significantly improves specificity
Objectives To evaluate the value of adding T2- and diffusion-weighted imaging (DWI) to the BI-RADS® classification in MRI-detected lesions. Methods This retrospective study included 112 consecutive patients who underwent 3.0T structural breast MRI with T2- and DWI on the basis of EUSOMA recommendations. Morphological and kinetic features, T2 signal intensity (T2 SI) and apparent diffusion coefficient (ADC) findings were assessed. Results Thirty-three (29.5 %) patients (mean age 57.0 ± 12.7 years) had 36 primarily MRI-detected incidental lesions of which 16 (44.4 %) proved to be malignant. No single morphological or kinetic feature was associated with malignancy. Both low T2 SI (P = 0.009) and low ADC values (≤0.87 × 10−3 mm2s−1, P < 0.001) yielded high specificity (80.0 %/80.0 %). The BI-RADS classification supplemented with information from DWI and T2-WI improved the diagnostic performance of the BI-RADS classification as sensitivity remained 100 % and specificity improved from 30 % to 65.0 %. The numbers of false positive lesions declined from 39 % (N = 14) to 19 % (N = 7). Conclusion MRI-detected incidental lesions may be challenging to characterize as they have few specific malignancy indicating features. The specificity of MRI can be improved by incorporating T2 SI and ADC values into the BI-RADS assessment. Key Points • MRI-detected incidental lesions have few specific malignancy indicating features. • ≥ 1 suspicious morphologic or kinetic feature may warrant biopsy. • T2 signal intensity and DWI assessment are feasible in primarily MRI-detected lesions. • T2 SI and DWI assessment improve the BI-RADS specificity in MRI-detected lesions.
- 2 July 2015
- Vol. 29 (4) , 487-91
Diagnostic Performance of Left Atrial Diameter Measurement in Computed Tomography to Detect Increased Left Atrial Volume.
The left atrium (LA) is frequently imaged in cardiac computed tomographic (cCT) examinations. The LA volume can be accurately measured with three-dimensional (3D) volumetry but this method is time consuming and thus not routinely used in clinical practice. Accordingly, increased LA size may be overlooked although volume enlargement is associated with adverse cardiovascular events. We evaluated the accuracy of LA diameter measurement in cCT and in transthoracic echocardiography (TTE) in the diagnosis of LA enlargement using 3D cCT as the reference standard. Altogether, 146 patients with suspected cardiogenic stroke underwent cCT and TTE. LA volume by cCT was determined for all patients. LA diameter was measured in both modalities. Furthermore, 40 healthy controls were analyzed in order to assess the cut-off values for normal LA volume. Diagnostic performance of cCT and conventional TTE diametrical measurements for detecting enlarged LA volume were analyzed and compared using Cohen's kappa (κ). In controls, the mean LA volume was 59.8±15.3 ml and the mean LA diameter was 30.4±5.0 mm by cCT. The mean value plus twice the standard deviation, which was considered the upper limit, for normal LA volume and diameter were 90.4 ml and 40.4 mm, respectively. Age- and gender-matched patients with stroke had statistically significantly (p<0.001) larger LA volumes (85.5±21.1 vs. 59.8±15.3 ml) and diameters (37.6±5.7 vs. 30.4±5.0 mm) than controls. LA diameter measurement by cCT was more reliable in detecting an LA volume enlargement than the corresponding measurement with TTE (κ=0.489 vs. 0.234; p=0.002). An enlarged LA diameter measured by cCT was more reliable than TTE at detecting enlarged LA volume.
- 2 July 2015
- Vol. 29 (4) , 487-91
Diagnostic Performance of Left Atrial Diameter Measurement in Computed Tomography to Detect Increased Left Atrial Volume.
The left atrium (LA) is frequently imaged in cardiac computed tomographic (cCT) examinations. The LA volume can be accurately measured with three-dimensional (3D) volumetry but this method is time consuming and thus not routinely used in clinical practice. Accordingly, increased LA size may be overlooked although volume enlargement is associated with adverse cardiovascular events. We evaluated the accuracy of LA diameter measurement in cCT and in transthoracic echocardiography (TTE) in the diagnosis of LA enlargement using 3D cCT as the reference standard. Altogether, 146 patients with suspected cardiogenic stroke underwent cCT and TTE. LA volume by cCT was determined for all patients. LA diameter was measured in both modalities. Furthermore, 40 healthy controls were analyzed in order to assess the cut-off values for normal LA volume. Diagnostic performance of cCT and conventional TTE diametrical measurements for detecting enlarged LA volume were analyzed and compared using Cohen's kappa (κ). In controls, the mean LA volume was 59.8±15.3 ml and the mean LA diameter was 30.4±5.0 mm by cCT. The mean value plus twice the standard deviation, which was considered the upper limit, for normal LA volume and diameter were 90.4 ml and 40.4 mm, respectively. Age- and gender-matched patients with stroke had statistically significantly (p<0.001) larger LA volumes (85.5±21.1 vs. 59.8±15.3 ml) and diameters (37.6±5.7 vs. 30.4±5.0 mm) than controls. LA diameter measurement by cCT was more reliable in detecting an LA volume enlargement than the corresponding measurement with TTE (κ=0.489 vs. 0.234; p=0.002). An enlarged LA diameter measured by cCT was more reliable than TTE at detecting enlarged LA volume.
- Open Access
- 2 July 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (7) , e101580
Morphological and Volumetric Analysis of Left Atrial Appendage and Left Atrium: Cardiac Computed Tomography-Based Reproducibility Assessment
Left atrial appendage (LAA) dilatation and morphology may influence an individual's risk for intracardiac thrombi and ischemic stroke. LAA size and morphology can be evaluated using cardiac computed tomography (cCT). The present study evaluated the reproducibility of LAA volume and morphology assessments. A total of 149 patients (47 females; mean age 60.9±10.6 years) with suspected cardioembolic stroke/transient ischemic attack underwent cCT. Image quality was rated based on four categories. Ten patients were selected from each image quality category (N = 40) for volumetric reproducibility analysis by two individual readers. LAA and left atrium (LA) volume were measured in both two-chamber (2CV) and transversal view (TV) orientation. Intertechnique reproducibility was assessed between 2CV and TV (200 measurement pairs). LAA morphology (A = Cactus, B = ChickenWing, C = WindSock, D = CauliFlower), LAA opening height, number of LAA lobes, trabeculation, and orientation of the LAA tip was analysed in all study subjects by three individual readers (447 interobserver measurement pairs). The reproducibility of volume measurements was assessed by intra-class correlation (ICC) and the reproducibility of LAA morphology assessments by Cohen's kappa. The intra-observer and interobserver reproducibility of LAA and LA volume measurements was excellent (ICCs>0.9). The LAA (ICC = 0.954) and LA (ICC = 0.945) volume measurements were comparable between 2CV and TV. Morphological classification (ĸ = 0.24) and assessments of LAA opening height (ĸ = 0.1), number of LAA lobes (ĸ = 0.16), trabeculation (ĸ = 0.15), and orientation of the LAA tip (ĸ = 0.37) was only slightly to fairly reproducible. LA and LAA volume measurements on cCT provide excellent reproducibility, whereas visual assessment of LAA morphological features is challenging and results in unsatisfactory agreement between readers.
- 2 July 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (7) , e101580
Open AccessMorphological and Volumetric Analysis of Left Atrial Appendage and Left Atrium: Cardiac Computed Tomography-Based Reproducibility Assessment
Left atrial appendage (LAA) dilatation and morphology may influence an individual's risk for intracardiac thrombi and ischemic stroke. LAA size and morphology can be evaluated using cardiac computed tomography (cCT). The present study evaluated the reproducibility of LAA volume and morphology assessments. A total of 149 patients (47 females; mean age 60.9±10.6 years) with suspected cardioembolic stroke/transient ischemic attack underwent cCT. Image quality was rated based on four categories. Ten patients were selected from each image quality category (N = 40) for volumetric reproducibility analysis by two individual readers. LAA and left atrium (LA) volume were measured in both two-chamber (2CV) and transversal view (TV) orientation. Intertechnique reproducibility was assessed between 2CV and TV (200 measurement pairs). LAA morphology (A = Cactus, B = ChickenWing, C = WindSock, D = CauliFlower), LAA opening height, number of LAA lobes, trabeculation, and orientation of the LAA tip was analysed in all study subjects by three individual readers (447 interobserver measurement pairs). The reproducibility of volume measurements was assessed by intra-class correlation (ICC) and the reproducibility of LAA morphology assessments by Cohen's kappa. The intra-observer and interobserver reproducibility of LAA and LA volume measurements was excellent (ICCs>0.9). The LAA (ICC = 0.954) and LA (ICC = 0.945) volume measurements were comparable between 2CV and TV. Morphological classification (ĸ = 0.24) and assessments of LAA opening height (ĸ = 0.1), number of LAA lobes (ĸ = 0.16), trabeculation (ĸ = 0.15), and orientation of the LAA tip (ĸ = 0.37) was only slightly to fairly reproducible. LA and LAA volume measurements on cCT provide excellent reproducibility, whereas visual assessment of LAA morphological features is challenging and results in unsatisfactory agreement between readers.
- Open Access
- 4 March 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (3) , e90903
Determinants of Left Atrial Appendage Volume in Stroke Patients without Chronic Atrial Fibrillation
Left atrial appendage (LAA) volume has been shown to be increased in patients with acute cryptogenic stroke. Atrial fibrillation (AF) is a well-recognized risk factor but it is not the only one associated with LAA enlargement. The aim of the study was to clarify the multifactorial etiology of LAA enlargement in cardiogenic stroke/TIA patients without AF. Altogether 149 patients with suspected cardioembolic stroke/TIA (47 females; mean age 61 years) underwent cardiac CT. Diagnosed AF on admittance was an exclusion criteria but 24-hour Holter ambulatory ECG revealed paroxysmal AF (PAF) in 20 patients. Body surface area adjusted LAA volume was evaluated. Eighteen different variables were registered including general characteristics, definite and potential causal risk factors for ischemic stroke/TIA, clinical echoparameters and CT based cardiac volumetric and adipose tissue measurements. A stepwise linear regression analysis was performed to achieve a model adjusted for the number of predictors of LAA volume increase. In linear regression analysis, the best model accounted for 30% of the variability in LAA volume, including PAF (19%) and enlarged left atrial volume (6%), enlarged left ventricle end-systolic diameter (3%) and decreased pericardial adipose tissue (2%). No multi-colinearity between variables was observed. In addition to PAF, no other definitive or potential causal risk factors could account for the LAA volume in these patients. LAA volume increase seems to be poorly associated with currently known stroke/TIA risk factors, except for AF. Targeting more comprehensive ECG monitoring for stroke patients with increased LAA volume should be considered.
- 4 March 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (3) , e90903
Open AccessDeterminants of Left Atrial Appendage Volume in Stroke Patients without Chronic Atrial Fibrillation
Left atrial appendage (LAA) volume has been shown to be increased in patients with acute cryptogenic stroke. Atrial fibrillation (AF) is a well-recognized risk factor but it is not the only one associated with LAA enlargement. The aim of the study was to clarify the multifactorial etiology of LAA enlargement in cardiogenic stroke/TIA patients without AF. Altogether 149 patients with suspected cardioembolic stroke/TIA (47 females; mean age 61 years) underwent cardiac CT. Diagnosed AF on admittance was an exclusion criteria but 24-hour Holter ambulatory ECG revealed paroxysmal AF (PAF) in 20 patients. Body surface area adjusted LAA volume was evaluated. Eighteen different variables were registered including general characteristics, definite and potential causal risk factors for ischemic stroke/TIA, clinical echoparameters and CT based cardiac volumetric and adipose tissue measurements. A stepwise linear regression analysis was performed to achieve a model adjusted for the number of predictors of LAA volume increase. In linear regression analysis, the best model accounted for 30% of the variability in LAA volume, including PAF (19%) and enlarged left atrial volume (6%), enlarged left ventricle end-systolic diameter (3%) and decreased pericardial adipose tissue (2%). No multi-colinearity between variables was observed. In addition to PAF, no other definitive or potential causal risk factors could account for the LAA volume in these patients. LAA volume increase seems to be poorly associated with currently known stroke/TIA risk factors, except for AF. Targeting more comprehensive ECG monitoring for stroke patients with increased LAA volume should be considered.
- Open Access
- 4 November 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (11) , e79519
Left Atrial Appendage Volume Increased in More Than Half of Patients with Cryptogenic Stroke
Ischemic strokes without a well-defined etiology are labeled as cryptogenic, and account for 30–40% of strokes in stroke registries. The left atrial appendage (LAA) is the most typical origin for intracardiac thrombus formation when associated with atrial fibrillation. Here, we examined whether increased LAA volume detected with cardiac computed tomography (cCT) constitutes a risk factor in cryptogenic stroke patients. This study included 82 stroke/TIA patients (57 males; mean age, 58 years) with a diagnosis of cryptogenic stroke after extensive radiological and cardiological investigations. Cases were classified using the TOAST criteria modified by European Association of Echocardiography recommendations for defining cardiac sources of embolism. Forty age- and gender-matched control subjects without cardiovascular diseases were selected for pair-wise comparisons (21 males; mean age, 54 years). LAA volume adjusted for body surface area was measured three dimensionally by tracing the LAA borders on electrocardiogram-gated CT slices. In control subjects, mean LAA volume was 3.4±1.1 mL/m2. Mean+2SD, which was considered the upper limit for normal LAA volume was 5.6 mL/m2. In paired Student t-test between the patient group and matched controls, LAA volume was 67% larger in cryptogenic stroke/TIA patients (5.7±2.0 mL/m2 vs. 3.4±1.1 mL/m2; P<0.001). Forty-five (55%) patients with cryptogenic stroke/TIA had enlarged LAA. LAA is significantly enlarged in more than half of patients with cryptogenic stroke/TIA. LAA thrombosis may contribute to the pathogenesis of stroke in patients considered to have cryptogenic stroke after conventional evaluation.
- 4 November 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (11) , e79519
Open AccessLeft Atrial Appendage Volume Increased in More Than Half of Patients with Cryptogenic Stroke
Ischemic strokes without a well-defined etiology are labeled as cryptogenic, and account for 30–40% of strokes in stroke registries. The left atrial appendage (LAA) is the most typical origin for intracardiac thrombus formation when associated with atrial fibrillation. Here, we examined whether increased LAA volume detected with cardiac computed tomography (cCT) constitutes a risk factor in cryptogenic stroke patients. This study included 82 stroke/TIA patients (57 males; mean age, 58 years) with a diagnosis of cryptogenic stroke after extensive radiological and cardiological investigations. Cases were classified using the TOAST criteria modified by European Association of Echocardiography recommendations for defining cardiac sources of embolism. Forty age- and gender-matched control subjects without cardiovascular diseases were selected for pair-wise comparisons (21 males; mean age, 54 years). LAA volume adjusted for body surface area was measured three dimensionally by tracing the LAA borders on electrocardiogram-gated CT slices. In control subjects, mean LAA volume was 3.4±1.1 mL/m2. Mean+2SD, which was considered the upper limit for normal LAA volume was 5.6 mL/m2. In paired Student t-test between the patient group and matched controls, LAA volume was 67% larger in cryptogenic stroke/TIA patients (5.7±2.0 mL/m2 vs. 3.4±1.1 mL/m2; P<0.001). Forty-five (55%) patients with cryptogenic stroke/TIA had enlarged LAA. LAA is significantly enlarged in more than half of patients with cryptogenic stroke/TIA. LAA thrombosis may contribute to the pathogenesis of stroke in patients considered to have cryptogenic stroke after conventional evaluation.