MGMahdi Ghorbani

Mahdi Ghorbani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mahdi Ghorbani has a total of 117 co-authors. Here are the top co-authors by number of shared publications:

  • Mohammad Taghi Bahreyni Toossi

    PhD, Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

    9 shared publications
  • Bagher Farhood

    Department of Medical Physics and Radiology, Faculty of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran

    7 shared publications
  • Courtney Knaup

    Comprehensive Cancer Centers of Nevada, Las Vegas, Nevada, USA

    6 shared publications
  • Ali Soleimani Meigooni

    PhD, Comprehensive Cancer Centres of Nevada, Las Vegas, USA

    5 shared publications
  • Mohamad Pursamimi

    Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    5 shared publications
  • Mohammad Reza Deevband

    Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    5 shared publications

Latest Publications

  • Open Access

    Comparison of Different Models in Calculation of Tumor Control Probability and Normal Tissue Complication Probability in Breast Cancer Radiotherapy

    by Hayder Tareq, Mahdi Ghorbani, Mohammad Reza Deevband, Mehdi Khosravi, Abdullah Ali

    Background: The aim of this study is to compare tumor control probability (TCP) for the planning target volume (PTV) using Poisson, Niemierko, and Zaider-Minerbo models, and normal tissue complication probability (NTCP) for organs at risk (OARs) using Niemierko, Lyman-Kutcher-Burman (LKB) and relative seriality (RS) models. Methods: Radiotherapy dosimetry data of sixty breast cancer patients were utilized to calculate TCP and NTCP with various models. Patients underwent planning using a 16-slice CT scanner, delivering 50 Gy in 25 fractions using 6 MV photon beam energy and the Monaco treatment planning system (TPS). Results: Significant differences in TCP were found between Poisson and Zaider-Minerbo models, and between Zaider-Minerbo and equivalent uniform dose (EUD) based models, with no difference between Poisson and EUD-based models. For NTCP, differences were observed between RS model and LKB for heart, spinal cord, and thyroid, as well as between RS model and EUD-based model for the heart, spinal cord and thyroid. LKB and EUD-based models showed differences when considering the lungs as an additional OAR. Conclusion: Differences among models for calculation TCP and NTCP emphasize the importance of considering specific treatment objectives and patient characteristics in breast cancer radiotherapy planning, ensuring optimized therapeutic outcomes while minimizing adverse effects on healthy tissues.

  • Open Access

    Comparison study between different treatment planning techniques for medulloblastoma in terms of dosimetry, radiobiology, and secondary cancer risk

    by Faramarz Abbasi, Mahdi Ghorbani, Fatemeh Seif, Mohammad Reza Deevband, Mohamad Pursamimi, Siamak Babai, Meysam Tavakoli

    Aim: To compare three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) for medulloblastoma patients by evaluating dosimetry, radiobiology, and secondary cancer risk parameters. Methods and Materials: Data from the Roshana Radiotherapy Center (Tehran, Iran) and the Ayatollah Khansari Hospital (Arak, Iran) were used to develop treatment plans using 3DCRT, IMRT, and VMAT for ten patients with medulloblastoma cancer. Using the Monaco® treatment planning system, all plans were created for an ELEKTA Versa HD linear accelerator with a 6 MV photon beam. For the planning target volume (PTV), dosimetric parameters (D min, D max, and D mean), conformity index (CI), homogeneity index (HI), and tumor control probability (TCP) were assessed. For organs at risk (OARs) and normal structures, the normal tissue complication probability (NTCP), excess absolute risk (EAR), and lifetime attributable risk (LAR) were calculated. Results: The greatest PTV coverage was attained by VMAT, closely trailed by IMRT, both of which were considerably superior to 3DCRT. Compared to 3DCRT, VMAT and IMRT had substantially improved CI and HI values. Similar trends were seen in the TCP values. Unexpectedly, IMRT showed better OAR sparing for many structures, especially in the thoracic area. In the head and neck region, VMAT demonstrated superior sparing for smaller structures. Conclusion: For the treatment of medulloblastoma, VMAT, and IMRT are generally better than 3DCRT because they offer better target coverage, conformance, and homogeneity. However, for many structures, IMRT showed unexpected superiority in OAR sparing.


  • Open Access

    A randomized controlled trial on the effect of cranial electrotherapy stimulation on depression, anxiety, and craving in addicted male patients undergoing methadone maintenance treatment

    by Homa Baghaei Ravari, Ali Kheradmand, Mahdi Ghorbani, Alireza Shamsi, Mehdi Khosravi

    Background: Addicted patients undergoing methadone maintenance treatment are prone to several complications and the risk of relapse. Objective: The present study aims to investigate the effect of cranial electrotherapy stimulation on depression, anxiety, and craving in addicted male people undergoing methadone maintenance treatment. Methods: This randomized controlled trial study was conducted on 60 male patients referred to Persia addiction treatment center between 2021 and 2022. Patients were randomly divided into two equal treatment and placebo groups. The treatment group received cranial electrotherapy stimulation intervention for 48 sessions of 30 min. Depression and anxiety were evaluated using the Hamilton questionnaire before and after the intervention, and the level of craving was also evaluated with the Federdi 2008 questionnaire. Results: Comparing the level of depression and anxiety before and after the intervention in both treatment and placebo groups did not show any significant difference (p < 0.05). Craving after the intervention was significantly different in both groups and was lower in the treatment group compared to the placebo group (33.43 versus 42.17, p = 0.004). In the placebo group, the level of anxiety and depression, and in the treatment group, the level of depression, anxiety and craving for consumption decreased significantly after the intervention compared to before the intervention (p < 0.05). Conclusion: Cranial electrotherapy stimulation did not have a significant effect on reducing the level of depression and anxiety of patients, but it is effective in the reduction of craving in addicted people undergoing methadone maintenance treatment. Trial registration: This randomized clinical trial was registered on 2022/5/13 with clinical trial code of IRCT20210523051367N1.


  • Open Access

    Effect of cranial electrotherapy stimulation (CES) in treatment of premature ejaculation: a randomized clinical trial

    by Hadi Delpasand, Azadeh Mazaheri, Ali Kheradmand, Mahdi Ghorbani, Amir Reza Abedi, Mohsen Khosroabadi

    Background: Premature ejaculation is one of the most common male sexual dysfunction, affecting approximately 30% of men. The aim of this study is to evaluate the efficacy and at the same time the safety of the cranial electrotherapy stimulation (CES) device in treatment of premature ejaculation disorder. Methods: Based on a randomized clinical trial, two groups were included in the study, so that the first group was treated with sertraline along with an ATANG (AT-9 model) CES, and the second group with sertraline and inactive the CES device (as the placebo group). The state of premature ejaculation after treatment (using the Premature Ejaculation Diagnostic Tool (PEDT) questionnaire) was evaluated and compared for both groups. Results: In the intervention and placebo groups, the average score of the PEDT questionnaire before the intervention did not differ significantly between the two groups (p-value equal to 0.93). However, the average score of the PEDT questionnaire after the intervention for CES group and placebo group was 10.28 ± 1.93 and 13.23 ± 3.05, respectively, which demonstrated a significant decrease in the intervention group (p-value equal to 0.01). Conclusion: The use of CES device as a complementary treatment along with routine drug treatment (sertraline) is associated with a significant improvement in the condition of premature ejaculation of patients. Trial registration: Name of the registry: IRCT Iranian Registry of Clinical Trials. Trial registration number: IRCT20210621051657N1. Date of registration: December 11, 2022. URL of trial registry record: https://en.irct.ir/trial/57201.


  • Open Access

    Machine learning-based diagnosis and risk classification of coronary artery disease using myocardial perfusion imaging SPECT: A radiomics study

    by Mehdi Amini, Mohamad Pursamimi, Ghasem Hajianfar, Yazdan Salimi, Abdollah Saberi, Ghazal Mehri-Kakavand, Mostafa Nazari, Mahdi Ghorbani, Ahmad Shalbaf, Isaac Shiri, et al.

    This study aimed to investigate the diagnostic performance of machine learning-based radiomics analysis to diagnose coronary artery disease status and risk from rest/stress Myocardial Perfusion Imaging (MPI) single-photon emission computed tomography (SPECT). A total of 395 patients suspicious of coronary artery disease who underwent 2-day stress-rest protocol MPI SPECT were enrolled in this study. The left ventricle myocardium, excluding the cardiac cavity, was manually delineated on rest and stress images to define a volume of interest. Added to clinical features (age, sex, family history, diabetes status, smoking, and ejection fraction), a total of 118 radiomics features, were extracted from rest and stress MPI SPECT images to establish different feature sets, including Rest-, Stress-, Delta-, and Combined-radiomics (all together) feature sets. The data were randomly divided into 80% and 20% subsets for training and testing, respectively. The performance of classifiers built from combinations of three feature selections, and nine machine learning algorithms was evaluated for two different diagnostic tasks, including 1) normal/abnormal (no CAD vs. CAD) classification, and 2) low-risk/high-risk CAD classification. Different metrics, including the area under the ROC curve (AUC), accuracy (ACC), sensitivity (SEN), and specificity (SPE), were reported for models’ evaluation. Overall, models built on the Stress feature set (compared to other feature sets), and models to diagnose the second task (compared to task 1 models) revealed better performance. The Stress-mRMR-KNN (feature set-feature selection-classifier) reached the highest performance for task 1 with AUC, ACC, SEN, and SPE equal to 0.61, 0.63, 0.64, and 0.6, respectively. The Stress-Boruta-GB model achieved the highest performance for task 2 with AUC, ACC, SEN, and SPE of 0.79, 0.76, 0.75, and 0.76, respectively. Diabetes status from the clinical feature family, and dependence count non-uniformity normalized, from the NGLDM family, which is representative of non-uniformity in the region of interest were the most frequently selected features from stress feature set for CAD risk classification. This study revealed promising results for CAD risk classification using machine learning models built on MPI SPECT radiomics. The proposed models are helpful to alleviate the labor-intensive MPI SPECT interpretation process regarding CAD status and can potentially expedite the diagnostic process.


  • Open Access

    Incidence risk assessment of secondary cancer due to radiotherapy of women with rectal cancer using BEIR VII, EPA, and ICRP models

    by Rowaidah Hamzah, Mohammad Reza Deevband, Mahdi Ghorbani, Mehdi Khosravi, Faranak Sadeghi Pour

    Background: Radiotherapy has a significant side effect known as radiation-induced secondary cancer. This study aims to evaluate the dose and secondary cancer risk for women with rectal cancer treated with three-dimensional conformal radiation therapy (3DCRT) to the organs at risk (OARs) and some sensitive organs using different types of radiation-induced cancer risk prediction models, including Biological Effects of Ionizing Radiation (BEIRVII), Environmental Protection Agency (EPA) and International Commission on Radiological Protection (ICRP), and compare the results of the different models for same organs. Materials and methods: Thirty female patients with rectal cancer were considered and dose calculations were based on the PCRT-3D treatment planning system, while the radiotherapy of the patients had been performed using Shinva linear accelerator with a total dose of 45 Gy at 25 fractions. Planning target volume (PTV), OARs, and some sensitive organs were contoured, three models were used to evaluate secondary cancer risk (SCR) using the excess relative risk (ERR) and excess absolute risk (EAR). Results: The bladder presents the highest risk, in terms of ERR, and the femur head and uterus in terms of EAR from the three models (BEIR VII, EPA, and ICRP). Conclusion: Based on the obtained results, radiotherapy of rectal cancer is relatively higher for the bladder and femur head, compared to the risk for other organs, the kidney risk is significantly lower. It was observed that the SCR from the ICRP model was higher compared to BEIR VII and EPA models. Background: Radiotherapy has a significant side effect known as radiation-induced secondary cancer. This study aims to evaluate the dose and secondary cancer risk for women with rectal cancer treated with three-dimensional conformal radiation therapy (3DCRT) to the organs at risk (OARs) and some sensitive organs using different types of radiation-induced cancer risk prediction models, including Biological Effects of Ionizing Radiation (BEIRVII), Environmental Protection Agency (EPA) and International Commission on Radiological Protection (ICRP), and compare the results of the different models for same organs. Materials and methods: Thirty female patients with rectal cancer were considered and dose calculations were based on the PCRT-3D treatment planning system, while the radiotherapy of the patients had been performed using Shinva linear accelerator with a total dose of 45 Gy at 25 fractions. Planning target volume (PTV), OARs, and some sensitive organs were contoured, three models were used to evaluate secondary cancer risk (SCR) using the excess relative risk (ERR) and excess absolute risk (EAR). Results: The bladder presents the highest risk, in terms of ERR, and the femur head and uterus in terms of EAR from the three models (BEIR VII, EPA, and ICRP). Conclusion: Based on the obtained results, radiotherapy of rectal cancer is relatively higher for the bladder and femur head, compared to the risk for other organs, the kidney risk is significantly lower. It was observed that the SCR from the ICRP model was higher compared to BEIR VII and EPA models.


  • Open Access

    Comparison of PRIMO Monte Carlo code and Eclipse treatment planning system in calculation of dosimetric parameters in brain cancer radiotherapy

    by Ali Altuwayrish, Mahdi Ghorbani, Mohsen Bakhshandeh, Zahra Roozmand, Mojtaba Hosseini

    Background: It is important to evaluate the dose calculated by treatment planning systems (TPSs) and dose distribution in tumor and organs at risk (OARs). The aim of this study is to compare dose calculated by the PRIMO Monte Carlo code and Eclipse TPS in radiotherapy of brain cancer patients. Materials and methods: PRIMO simulation code was used to simulate a Varian Clinac 600C linac. The simulations were validated for the linac by comparison of the simulation and measured results. In the case of brain cancer patients, the dosimetric parameters obtained by the PRIMO code were compared with those calculated by Eclipse TPS. Gamma function analysis with 3%, 3 mm criteria was utilized to compare the dose distributions. The evaluations were based on the dosimetric parameters for the planning target volume (PTV) and OAR including Dmin, Dmean, and Dmax, homogeneity index (HI), and conformity index (CI). Results: The gamma function analysis showed a 98% agreement between the results obtained by the PRIMO code and measurement for the percent depth dose (PDD) and dose profiles. The corresponding value in comparing the dosimetric parameters from PRIMO code and Eclipse TPS for the brain patients was 94%, on average. The results of the PRIMO simulation were in good agreement with the measured data and Eclipse TPS calculations. Conclusions: Based on the results of this study, the PRIMO code can be utilized to simulate a medical linac with good accuracy and to evaluate the accuracy of treatment plans for patients with brain cancer. Background: It is important to evaluate the dose calculated by treatment planning systems (TPSs) and dose distribution in tumor and organs at risk (OARs). The aim of this study is to compare dose calculated by the PRIMO Monte Carlo code and Eclipse TPS in radiotherapy of brain cancer patients. Materials and methods: PRIMO simulation code was used to simulate a Varian Clinac 600C linac. The simulations were validated for the linac by comparison of the simulation and measured results. In the case of brain cancer patients, the dosimetric parameters obtained by the PRIMO code were compared with those calculated by Eclipse TPS. Gamma function analysis with 3%, 3 mm criteria was utilized to compare the dose distributions. The evaluations were based on the dosimetric parameters for the planning target volume (PTV) and OAR including Dmin, Dmean, and Dmax, homogeneity index (HI), and conformity index (CI). Results: The gamma function analysis showed a 98% agreement between the results obtained by the PRIMO code and measurement for the percent depth dose (PDD) and dose profiles. The corresponding value in comparing the dosimetric parameters from PRIMO code and Eclipse TPS for the brain patients was 94%, on average. The results of the PRIMO simulation were in good agreement with the measured data and Eclipse TPS calculations. Conclusions: Based on the results of this study, the PRIMO code can be utilized to simulate a medical linac with good accuracy and to evaluate the accuracy of treatment plans for patients with brain cancer.


  • Open Access

    Assessment of Field-in-Field, 3-Field, and 4-Field Treatment Planning Methods for Radiotherapy of Gastro-Esophageal Junction Cancer

    by Ghazal Mehri-Kakavand, Mohamad Pursamimi, Wrya Parwaie, Mahdi Ghorbani, Mehdi Khosrav, Seyyed Mohammad Hosseini, Ali Soleimani Meigooni

    Background: Gastro-esophageal (GE) junction cancer is the fastest-growing tumor, particularly in the United States (US). Objective: This study aimed to compare dosimetric and radiobiological factors among field-in-field (FIF), three-field (3F), and four-field box (4FB) radiotherapy planning techniques for gastro-esophageal junction cancer.Material and Methods: In this experimental study, thirty patients with GE junction cancer were evaluated, and three planning techniques (field-in-field (FIF), three-field (3F), and four-field box (4FB)) were performed for each patient for a 6-MV photon beam. Dose distribution in the target volume, the monitor units (MUs) required, and the dose delivered to organs at risk (OARs) were compared for these techniques using the paired-sample t-test. Results: A significant difference was measured between the FIF and 3F techniques with respect to conformity index (CI), dose homogeneity index (HI), and tumor control probability (TCP) for the target organ, as well as the Dmean for the heart, kidneys, and liver. For the spinal cord, the FIF technique showed a slight reduction in the maximum dose compared to the other two techniques. In addition, the V20 Gy of the lungs and the normal tissue complication probability (NTCP) of all OARs were reduced with FIF method. Conclusion: The FIF technique showed better performance for treating patients with gastro-esophageal junction tumors, in terms of dose homogeneity in the target, conformity of the radiation field with the target volume, TCP, less dose to healthy organs, and fewer MU.


  • Open Access

    Automatic diagnosis of severity of COVID-19 patients using an ensemble of transfer learning models with convolutional neural networks in CT images

    by Ahmad Shalbaf, Parisa Gifani, Ghazal Mehri-Kakavand, Mohamad Pursamimi, Mahdi Ghorbani, Amirhossein Abbaskhani Davanloo, Majid Vafaeezadeh


  • Detection of stage of lung changes in COVID-19 disease based on CT images: a radiomics approach

    by Mohammad Mehrpouyan, Hamed Zamanian, Ghazal Mehri-Kakavand, Mohamad Pursamimi, Ahmad Shalbaf, Mahdi Ghorbani, Amirhossein Abbaskhani Davanloo

    The aim of this study is to classify patients suspected from COVID-19 to five stages as normal, early, progressive, peak, and absorption stages using radiomics approach based on lung computed tomography images. Lung CT scans of 683 people were evaluated. A set of statistical texture features was extracted from each CT image. The people were classified using the random forest algorithm as an ensemble method based on the decision trees outputs to five stages of COVID-19 disease. Proposed method attains the highest result with an accuracy of 93.55% (96.25% in normal, 74.39% in early, 100% in progressive, 82.19% in peak, and 96% in absorption stage) compared to the other three common classifiers. Radiomics method can be used for the classification of the stage of COVID-19 disease with good accuracy to help decide the length of time required to hospitalize patients, determine the type of treatment process required for patients in each category, and reduce the cost of care and treatment for hospitalized individuals.