Marc J. Nieuwenhuijse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marc J. Nieuwenhuijse has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Arian R. van Erkel
4 shared publications- Rob Gerardus Henricus Hubertus Nelissen
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
4 shared publications - Bart L. Kaptein
Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
3 shared publications Edward R. Valstar
Department of Orthopaedics, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300 RC Leiden, The Netherlands. address for M.J. Nieuwenhuijse
2 shared publicationsP. D. S. Dijkstra
2 shared publicationsA. R. van Erkel
Leiden University Medical Centre, Department of Radiology Surgery, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
1 shared publication
Latest Publications
- 17 April 2019
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 477 (5) , 1034-1035
CORR Insights®: The Pattern of Acetabular Cartilage Wear Is Hip Morphology-dependent and Patient Demographic-dependent
- 17 April 2019
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 477 (5) , 1034-1035
CORR Insights®: The Pattern of Acetabular Cartilage Wear Is Hip Morphology-dependent and Patient Demographic-dependent
- 1 January 2015
- Vol. 159, A8652
[The introduction of new medical devices].
Regulation of the introduction of new or improved medical devices is fundamentally different from that of new drugs and is inadequate in its current form. This was recently demonstrated by large-scale problems with medical devices in various specialist fields. Steps have been taken by scientific professional associations, regulating authorities and industry to prevent these problems from happening in the future. However, these steps have not yet been implemented or have not been sufficiently well implemented, and have not been completely coordinated. The practitioner therefore needs to remain extremely critical when using new medical devices.
- 1 January 2015
- Vol. 159, A8652
[The introduction of new medical devices].
Regulation of the introduction of new or improved medical devices is fundamentally different from that of new drugs and is inadequate in its current form. This was recently demonstrated by large-scale problems with medical devices in various specialist fields. Steps have been taken by scientific professional associations, regulating authorities and industry to prevent these problems from happening in the future. However, these steps have not yet been implemented or have not been sufficiently well implemented, and have not been completely coordinated. The practitioner therefore needs to remain extremely critical when using new medical devices.
- 2 October 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (19) , e141-11
Fixation of High-Flexion Total Knee Prostheses: Five-Year Follow-up Results of a Four-Arm Randomized Controlled Clinical and Roentgen Stereophotogrammetric Analysis Study
Background: High-flexion total knee arthroplasty was introduced to meet the demands of daily activity requiring increased knee flexion. However, concerns have been raised regarding the fixation of high-flexion total knee arthroplasty components and increased rates of loosening have been reported. To date, migration, and thus fixation, of high-flexion total knee arthroplasty components has not been analyzed and the preferential bearing type (mobile or fixed) is unknown. Methods: Of eighty-six consecutive eligible patients, seventy-four patients (seventy-eight knees) scheduled for total knee arthroplasty were randomized to one of four Legacy Posterior Stabilized (LPS) total knee prosthesis designs: (1) LPS-Flex mobile, (2) LPS-Flex fixed, (3) LPS mobile, and (4) LPS fixed. The primary outcome was component migration measured with use of Roentgen stereophotogrammetric analysis, and secondary outcomes were postoperative knee flexion and extension and Knee Society Score. Patients were evaluated postoperatively at six, twelve, twenty-six, and fifty-two weeks and annually thereafter. At the five-year follow-up, eight patients had died and two patients were lost to follow-up. Seventy-seven tibial and forty-two femoral components were suitable for migration measurements. Results: The overall five-year migration of the seventy-seven tibial components was not significantly different among the four total knee prosthesis designs (compared with the LPS fixed design, the range of overall mean differences for the other three designs was 0.02 to 0.25 mm) and migration was comparable at the two and five-year follow-up. Migration stabilized in all but three components (two LPS-Flex mobile and one LPS fixed); one of these components has already been revised and was aseptically loose. The overall five-year migration of the forty-two femoral components was comparable among the four designs (compared with the LPS fixed design, the range of overall mean differences for the other three designs was 0.01 to 0.18 mm) and was similar at two and five years postoperatively. One femoral component (LPS-Flex mobile) migrated excessively. In patients who had a mean postoperative flexion of ≥125° or a maximum flexion of ≥135° during the one to five-year follow-up period, migration of high-flexion components was comparable with that of conventional components and indicative of appropriate fixation. Postoperative flexion, extension, Knee Society Score, and Knee Society Score function were comparable during the five-year follow-up period and at the two and five-year follow-up. Conclusions: The LPS-Flex total knee prosthesis with either a mobile or a fixed bearing had migration comparable that of with its conventional counterpart and is expected to have similar (excellent) long-term survival in these patients. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 2 October 2013
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 95 (19) , e141-11
Fixation of High-Flexion Total Knee Prostheses: Five-Year Follow-up Results of a Four-Arm Randomized Controlled Clinical and Roentgen Stereophotogrammetric Analysis Study
Background: High-flexion total knee arthroplasty was introduced to meet the demands of daily activity requiring increased knee flexion. However, concerns have been raised regarding the fixation of high-flexion total knee arthroplasty components and increased rates of loosening have been reported. To date, migration, and thus fixation, of high-flexion total knee arthroplasty components has not been analyzed and the preferential bearing type (mobile or fixed) is unknown. Methods: Of eighty-six consecutive eligible patients, seventy-four patients (seventy-eight knees) scheduled for total knee arthroplasty were randomized to one of four Legacy Posterior Stabilized (LPS) total knee prosthesis designs: (1) LPS-Flex mobile, (2) LPS-Flex fixed, (3) LPS mobile, and (4) LPS fixed. The primary outcome was component migration measured with use of Roentgen stereophotogrammetric analysis, and secondary outcomes were postoperative knee flexion and extension and Knee Society Score. Patients were evaluated postoperatively at six, twelve, twenty-six, and fifty-two weeks and annually thereafter. At the five-year follow-up, eight patients had died and two patients were lost to follow-up. Seventy-seven tibial and forty-two femoral components were suitable for migration measurements. Results: The overall five-year migration of the seventy-seven tibial components was not significantly different among the four total knee prosthesis designs (compared with the LPS fixed design, the range of overall mean differences for the other three designs was 0.02 to 0.25 mm) and migration was comparable at the two and five-year follow-up. Migration stabilized in all but three components (two LPS-Flex mobile and one LPS fixed); one of these components has already been revised and was aseptically loose. The overall five-year migration of the forty-two femoral components was comparable among the four designs (compared with the LPS fixed design, the range of overall mean differences for the other three designs was 0.01 to 0.18 mm) and was similar at two and five years postoperatively. One femoral component (LPS-Flex mobile) migrated excessively. In patients who had a mean postoperative flexion of ≥125° or a maximum flexion of ≥135° during the one to five-year follow-up period, migration of high-flexion components was comparable with that of conventional components and indicative of appropriate fixation. Postoperative flexion, extension, Knee Society Score, and Knee Society Score function were comparable during the five-year follow-up period and at the two and five-year follow-up. Conclusions: The LPS-Flex total knee prosthesis with either a mobile or a fixed bearing had migration comparable that of with its conventional counterpart and is expected to have similar (excellent) long-term survival in these patients. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 1 March 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 266 (3) , 862-870
New Vertebral Fractures after Percutaneous Vertebroplasty for Painful Osteoporotic Vertebral Compression Fractures: A Clustered Analysis and the Relevance of Intradiskal Cement Leakage
Sustaining new vertebral fractures after percutaneous vertebroplasty in patients with painful osteoporotic vertebral compression fractures was clustered within patients and depended heavily on the presence or absence of both patient- and vertebra-specific risk factors. PurposeTo perform clustered analysis of fracture-free probabilities of intact nontreated vertebrae after percutaneous vertebroplasty (PVP) in painful long-standing osteoporotic vertebral compression fractures (OVCFs) to determine risk factors for new vertebral fractures and estimate fracture-free probabilities of multiple intact nontreated vertebrae given their patient- and vertebra-specific covariate status.Materials and MethodsInformed consent and institutional review board approval were obtained. A total of 115 patients who underwent PVP for 216 painful long-standing OVCFs were prospectively followed up to detect new OVCFs during the 1st postoperative year. A total of 1031 intact vertebrae were available for clustered analysis of fracture-free probabilities by using a Cox proportional hazard frailty model. A clustered analysis takes clustering or correlation of fracture-free survival probabilities of individual intact vertebrae within one patient into account to improve estimates of fracture-free proba...
- 1 March 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 266 (3) , 862-870
New Vertebral Fractures after Percutaneous Vertebroplasty for Painful Osteoporotic Vertebral Compression Fractures: A Clustered Analysis and the Relevance of Intradiskal Cement Leakage
Sustaining new vertebral fractures after percutaneous vertebroplasty in patients with painful osteoporotic vertebral compression fractures was clustered within patients and depended heavily on the presence or absence of both patient- and vertebra-specific risk factors. PurposeTo perform clustered analysis of fracture-free probabilities of intact nontreated vertebrae after percutaneous vertebroplasty (PVP) in painful long-standing osteoporotic vertebral compression fractures (OVCFs) to determine risk factors for new vertebral fractures and estimate fracture-free probabilities of multiple intact nontreated vertebrae given their patient- and vertebra-specific covariate status.Materials and MethodsInformed consent and institutional review board approval were obtained. A total of 115 patients who underwent PVP for 216 painful long-standing OVCFs were prospectively followed up to detect new OVCFs during the 1st postoperative year. A total of 1031 intact vertebrae were available for clustered analysis of fracture-free probabilities by using a Cox proportional hazard frailty model. A clustered analysis takes clustering or correlation of fracture-free survival probabilities of individual intact vertebrae within one patient into account to improve estimates of fracture-free proba...
- 1 September 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (20) , 1747-1755
Optimal Intravertebral Cement Volume in Percutaneous Vertebroplasty for Painful Osteoporotic Vertebral Compression Fractures
A prospective follow-up study. Assessment of the relation between accomplishment of pain relief through percutaneous vertebroplasty (PVP) in painful osteoporotic vertebral compression fractures (OVCFs) and the cemented fraction of the vertebral body and subsequent determination of the optimal intravertebral cement volume. The mechanism of pain relief of PVP as a treatment modality for painful OVCFs remains unclear. Generally, benefit of PVP is thought to result from stabilization of micromovements and collapse of the fractured vertebral body. However, studies indicating a relation between intravertebral cement volume and pain relief are lacking and an optimal value of the intravertebral cement volume is unknown. One hunderd six patients who received PVP for 196 painful OVCFs were prospectively followed on back pain (score 0-10) and occurrence of new OVCFs during the first postoperative year. Patients were classified as responders (average postoperative back pain ≤ 6) and nonresponders (average postoperative back pain >6). The cemented fraction of the vertebral body was determined using volumetric analysis of the postoperative CT scan of the treated levels. Analysis was performed using receiver-operating characteristic (ROC) analysis and multivariable regression techniques. Twenty-nine patients (27.3%) were found to be nonresponders. Mean intravertebral cement volume in all 196 treated OVCFs was 3.94 mL (SD = 1.89, range 0.13-10.8). The mean cemented vertebral body fraction was significantly lower in nonresponders (0.15 vs. 0.21, P = 0.002). The ROC area-under-curve of the cemented fraction as a predictor of accomplishment of pain relief was 0.67 (95% CI: 0.57-0.78, P = 0.006). In subgroups without specific influential factors (new OVCFs, intravertebral clefts), significantly stronger associations were found. A vertebral body fraction of 24% was identified as the optimal fraction to be cemented. This fraction corresponded to a 93% to 100% specificity for accomplishment of pain relief (i.e., few to no cases without pain relief in the presence of adequate cementing) without being significantly associated with a higher risk of occurrence of cement leakage or new OVCFs. Corresponding values for the recommended (optimal) intravertebral cement volume were provided based on its governing characteristics (fracture level, fracture severity, and patient's sex). An optimal intravertebral cement volume was identified for accomplishment of pain relief through PVP in painful OVCFs. Appropriate thresholds were provided to guide the operator.
- 1 September 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (20) , 1747-1755
Optimal Intravertebral Cement Volume in Percutaneous Vertebroplasty for Painful Osteoporotic Vertebral Compression Fractures
A prospective follow-up study. Assessment of the relation between accomplishment of pain relief through percutaneous vertebroplasty (PVP) in painful osteoporotic vertebral compression fractures (OVCFs) and the cemented fraction of the vertebral body and subsequent determination of the optimal intravertebral cement volume. The mechanism of pain relief of PVP as a treatment modality for painful OVCFs remains unclear. Generally, benefit of PVP is thought to result from stabilization of micromovements and collapse of the fractured vertebral body. However, studies indicating a relation between intravertebral cement volume and pain relief are lacking and an optimal value of the intravertebral cement volume is unknown. One hunderd six patients who received PVP for 196 painful OVCFs were prospectively followed on back pain (score 0-10) and occurrence of new OVCFs during the first postoperative year. Patients were classified as responders (average postoperative back pain ≤ 6) and nonresponders (average postoperative back pain >6). The cemented fraction of the vertebral body was determined using volumetric analysis of the postoperative CT scan of the treated levels. Analysis was performed using receiver-operating characteristic (ROC) analysis and multivariable regression techniques. Twenty-nine patients (27.3%) were found to be nonresponders. Mean intravertebral cement volume in all 196 treated OVCFs was 3.94 mL (SD = 1.89, range 0.13-10.8). The mean cemented vertebral body fraction was significantly lower in nonresponders (0.15 vs. 0.21, P = 0.002). The ROC area-under-curve of the cemented fraction as a predictor of accomplishment of pain relief was 0.67 (95% CI: 0.57-0.78, P = 0.006). In subgroups without specific influential factors (new OVCFs, intravertebral clefts), significantly stronger associations were found. A vertebral body fraction of 24% was identified as the optimal fraction to be cemented. This fraction corresponded to a 93% to 100% specificity for accomplishment of pain relief (i.e., few to no cases without pain relief in the presence of adequate cementing) without being significantly associated with a higher risk of occurrence of cement leakage or new OVCFs. Corresponding values for the recommended (optimal) intravertebral cement volume were provided based on its governing characteristics (fracture level, fracture severity, and patient's sex). An optimal intravertebral cement volume was identified for accomplishment of pain relief through PVP in painful OVCFs. Appropriate thresholds were provided to guide the operator.
- 1 June 2012
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94-B (6) , 815-820
Percutaneous vertebroplasty for subacute and chronic painful osteoporotic vertebral compression fractures can safely be undertaken in the first year after the onset of symptoms
The optimal timing of percutaneous vertebroplasty as treatment for painful osteoporotic vertebral compression fractures (OVCFs) is still unclear. With the position of vertebroplasty having been challenged by recent placebo-controlled studies, appropriate timing gains importance. We investigated the relationship between the onset of symptoms – the time from fracture – and the efficacy of vertebroplasty in 115 patients with 216 painful subacute or chronic OVCFs (mean time from fracture 6.0 months (sd 2.9)). These patients were followed prospectively in the first post-operative year to assess the level of back pain and by means of health-related quality of life (HRQoL). We also investigated whether greater time from fracture resulted in a higher risk of complications or worse pre-operative condition, increased vertebral deformity or the development of nonunion of the fracture as demonstrated by the presence of an intravertebral cleft. It was found that there was an immediate and sustainable improvement in the level of back pain and HRQoL after vertebroplasty, which was independent of the time from fracture. Greater time from fracture was associated with neither worse pre-operative conditions nor increased vertebral deformity, nor with the presence of an intravertebral cleft. We conclude that vertebroplasty can be safely undertaken at an appropriate moment between two and 12 months following the onset of symptoms of an OVCF.
- 1 June 2012
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94-B (6) , 815-820
Percutaneous vertebroplasty for subacute and chronic painful osteoporotic vertebral compression fractures can safely be undertaken in the first year after the onset of symptoms
The optimal timing of percutaneous vertebroplasty as treatment for painful osteoporotic vertebral compression fractures (OVCFs) is still unclear. With the position of vertebroplasty having been challenged by recent placebo-controlled studies, appropriate timing gains importance. We investigated the relationship between the onset of symptoms – the time from fracture – and the efficacy of vertebroplasty in 115 patients with 216 painful subacute or chronic OVCFs (mean time from fracture 6.0 months (sd 2.9)). These patients were followed prospectively in the first post-operative year to assess the level of back pain and by means of health-related quality of life (HRQoL). We also investigated whether greater time from fracture resulted in a higher risk of complications or worse pre-operative condition, increased vertebral deformity or the development of nonunion of the fracture as demonstrated by the presence of an intravertebral cleft. It was found that there was an immediate and sustainable improvement in the level of back pain and HRQoL after vertebroplasty, which was independent of the time from fracture. Greater time from fracture was associated with neither worse pre-operative conditions nor increased vertebral deformity, nor with the presence of an intravertebral cleft. We conclude that vertebroplasty can be safely undertaken at an appropriate moment between two and 12 months following the onset of symptoms of an OVCF.
- 16 May 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (10) , 874-880
Good Diagnostic Performance of Early Migration as a Predictor of Late Aseptic Loosening of Acetabular Cups
Background: Excessive early migration of femoral stems following total hip arthroplasty and tibial components following total knee arthroplasty is associated with their long-term survival and allows reliable early evaluation of implant performance. However, a similar relationship involving acetabular components following hip arthroplasty has not been evaluated. This prospective, long-term study with clinical and Roentgen stereophotogrammetric analysis (RSA) follow-up establishes the existence of this relationship and its associated diagnostic performance. Methods: Thirty-nine consecutive patients (forty-one hips) who underwent total hip arthroplasty with a cemented Exeter stem and a cemented Exeter all-polyethylene cup had prospective clinical and RSA follow-up. Patients were evaluated postoperatively at six weeks, at three, six, and twelve months, and annually thereafter. Conventional anteroposterior and lateral radiographs were made at six weeks and at two, five, and ten years postoperatively as well as when indicated. The mean duration of follow-up (and standard deviation) was 9.4 ± 3.2 years. No patients were lost to follow-up; fifteen patients died during the follow-up period. Results: Eleven acetabular components were observed to be loose on conventional radiographs after a mean of seventy-six months (range, twelve to 140 months). During the first two postoperative years, the failed acetabular components showed markedly greater and more rapid cranial translation and sagittal rotation. Both cranial translation (hazard ratio = 19.9 [95% confidence interval, 4.94 to 80.0], p < 0.001) and sagittal rotation (hazard ratio = 11.1 [95% confidence interval, 2.83 to 43.9], p = 0.001) were strong risk factors for late aseptic loosening. Eight of the eleven failed components showed a distinctive pattern of excessive cranial translation combined with excessive sagittal rotation. The associated diagnostic performance of two-year cranial translation and/or sagittal rotation for predicting late aseptic loosening of the acetabular component was good (area under the receiver operating characteristic curve, 0.88 [95% confidence interval, 0.74 to 1.00; p < 0.001] and 0.84 [95% confidence interval, 0.68 to 1.00; p = 0.001], respectively). Conclusions: Early migration, as measured by RSA at two years postoperatively, has good diagnostic capabilities for the detection of acetabular components at risk for future aseptic loosening, and this method appears to be an appropriate means of assessing the performance of new implants or implant-related changes. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 16 May 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (10) , 874-880
Good Diagnostic Performance of Early Migration as a Predictor of Late Aseptic Loosening of Acetabular Cups
Background: Excessive early migration of femoral stems following total hip arthroplasty and tibial components following total knee arthroplasty is associated with their long-term survival and allows reliable early evaluation of implant performance. However, a similar relationship involving acetabular components following hip arthroplasty has not been evaluated. This prospective, long-term study with clinical and Roentgen stereophotogrammetric analysis (RSA) follow-up establishes the existence of this relationship and its associated diagnostic performance. Methods: Thirty-nine consecutive patients (forty-one hips) who underwent total hip arthroplasty with a cemented Exeter stem and a cemented Exeter all-polyethylene cup had prospective clinical and RSA follow-up. Patients were evaluated postoperatively at six weeks, at three, six, and twelve months, and annually thereafter. Conventional anteroposterior and lateral radiographs were made at six weeks and at two, five, and ten years postoperatively as well as when indicated. The mean duration of follow-up (and standard deviation) was 9.4 ± 3.2 years. No patients were lost to follow-up; fifteen patients died during the follow-up period. Results: Eleven acetabular components were observed to be loose on conventional radiographs after a mean of seventy-six months (range, twelve to 140 months). During the first two postoperative years, the failed acetabular components showed markedly greater and more rapid cranial translation and sagittal rotation. Both cranial translation (hazard ratio = 19.9 [95% confidence interval, 4.94 to 80.0], p < 0.001) and sagittal rotation (hazard ratio = 11.1 [95% confidence interval, 2.83 to 43.9], p = 0.001) were strong risk factors for late aseptic loosening. Eight of the eleven failed components showed a distinctive pattern of excessive cranial translation combined with excessive sagittal rotation. The associated diagnostic performance of two-year cranial translation and/or sagittal rotation for predicting late aseptic loosening of the acetabular component was good (area under the receiver operating characteristic curve, 0.88 [95% confidence interval, 0.74 to 1.00; p < 0.001] and 0.84 [95% confidence interval, 0.68 to 1.00; p = 0.001], respectively). Conclusions: Early migration, as measured by RSA at two years postoperatively, has good diagnostic capabilities for the detection of acetabular components at risk for future aseptic loosening, and this method appears to be an appropriate means of assessing the performance of new implants or implant-related changes. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 May 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (11) , 974-981
The Intravertebral Cleft in Painful Long-Standing Osteoporotic Vertebral Compression Fractures Treated With Percutaneous Vertebroplasty
Prospective follow-up study. Evaluation of the diagnostic assessment and clinical significance of the intravertebral cleft in painful, long-standing osteoporotic vertebral compression fractures (OVCFs) treated with percutaneous vertebroplasty (PVP). Patients with painful OVCFs with intravertebral clefts provide a unique and possibly superior indication for PVP. However, comparative studies are scarce, and the results are conflicting. The extent of the difference attributable to interobserver variation in the identification of an intravertebral cleft is currently unknown. A total of 102 patients received PVP for 197 painful long-standing OVCFs and were prospectively observed, using a pain-intensity numerical-rating scale for back pain, the 36-Item Short Form Health Survey quality-of-life questionnaire, and routine spinal radiographs. Three experienced examiners retrospectively examined all preoperative radiographs and magnetic resonance imaging (MRI) T1-weighted and short-tau-inversion-recovery (STIR) sequences and the direct postoperative computed tomographic scans for the presence of an intravertebral cleft. Disagreements were re-examined and discussed for consensus. Interobserver agreement for the detection of an intravertebral cleft was moderate on preoperative radiography (κ, 0.55−0.59) and substantial on preoperative MRI (κ, 0.71–0.79) and postoperative computed tomography (κ, 0.67–0.85). On the basis of consensus, 42 (21.3%) clefts were detected. The associated sensitivity of preoperative radiography was low (31.7%–48.8%), but the specificity was high (94.7%–99.3%). The diagnostic performance of preoperative MRI T1-weighted and STIR sequences was excellent, with both high sensitivity (85.7%–88.1%) and high specificity (89.7%–98.1%). Pain decrease and increase in quality of life obtained from PVP were ultimately comparable with patients without intravertebral clefts but was obtained more gradually during the first postoperative year. An intravertebral cleft was a strong risk factor for the occurrence of cortical cement leakage (odds ratio, 4.29; 95% confidence interval, 1.51–12.2; P = 0.006). There is variation between observers in the identification of an intravertebral cleft, and the identification of an intravertebral cleft is not always straightforward. For preoperative assessment, we recommend MRI with T1-weighted and STIR sequences. Regarding patient-reported outcome, patients with long-standing OVCFs with intravertebral clefts benefit from PVP, but, compared with patients with OVCFs without intravertebral clefts, the benefit obtained was not superior and may be delayed.
- 1 May 2012
- Published by Wolters Kluwer Health in Spine
- Vol. 37 (11) , 974-981
The Intravertebral Cleft in Painful Long-Standing Osteoporotic Vertebral Compression Fractures Treated With Percutaneous Vertebroplasty
Prospective follow-up study. Evaluation of the diagnostic assessment and clinical significance of the intravertebral cleft in painful, long-standing osteoporotic vertebral compression fractures (OVCFs) treated with percutaneous vertebroplasty (PVP). Patients with painful OVCFs with intravertebral clefts provide a unique and possibly superior indication for PVP. However, comparative studies are scarce, and the results are conflicting. The extent of the difference attributable to interobserver variation in the identification of an intravertebral cleft is currently unknown. A total of 102 patients received PVP for 197 painful long-standing OVCFs and were prospectively observed, using a pain-intensity numerical-rating scale for back pain, the 36-Item Short Form Health Survey quality-of-life questionnaire, and routine spinal radiographs. Three experienced examiners retrospectively examined all preoperative radiographs and magnetic resonance imaging (MRI) T1-weighted and short-tau-inversion-recovery (STIR) sequences and the direct postoperative computed tomographic scans for the presence of an intravertebral cleft. Disagreements were re-examined and discussed for consensus. Interobserver agreement for the detection of an intravertebral cleft was moderate on preoperative radiography (κ, 0.55−0.59) and substantial on preoperative MRI (κ, 0.71–0.79) and postoperative computed tomography (κ, 0.67–0.85). On the basis of consensus, 42 (21.3%) clefts were detected. The associated sensitivity of preoperative radiography was low (31.7%–48.8%), but the specificity was high (94.7%–99.3%). The diagnostic performance of preoperative MRI T1-weighted and STIR sequences was excellent, with both high sensitivity (85.7%–88.1%) and high specificity (89.7%–98.1%). Pain decrease and increase in quality of life obtained from PVP were ultimately comparable with patients without intravertebral clefts but was obtained more gradually during the first postoperative year. An intravertebral cleft was a strong risk factor for the occurrence of cortical cement leakage (odds ratio, 4.29; 95% confidence interval, 1.51–12.2; P = 0.006). There is variation between observers in the identification of an intravertebral cleft, and the identification of an intravertebral cleft is not always straightforward. For preoperative assessment, we recommend MRI with T1-weighted and STIR sequences. Regarding patient-reported outcome, patients with long-standing OVCFs with intravertebral clefts benefit from PVP, but, compared with patients with OVCFs without intravertebral clefts, the benefit obtained was not superior and may be delayed.
- Open Access
- 8 March 2012
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 83 (2) , 129-134
The Exeter femoral stem continues to migrate during its first decade after implantation
Due to its collarless, double-tapered polished design, the Exeter femoral stem is known to migrate distally in the first 5 years after implantation. However, its long-term migration pattern has not been investigated. 39 consecutive patients (41 total hip arthroplasties) received a cemented Exeter stem and had prospective clinical and RSA follow-up. Patients were evaluated postoperatively at 6, 12, 26, and 52 weeks, and annually thereafter. Short-term results have been reported. In this study, the mean length of follow-up was 9.4 years (SD 3.2 years). No patients were lost to follow-up. 15 patients died during follow-up. No stems were revised. In 4 stems, fractures of the cement mantle were noted within the first 3 postoperative years. In 3 stems, this resulted in a complete circumferential cement mantle discontinuity. For the 37 well-performing stems, continuous but small migration was measured between 2 and 12 years of follow-up. Continued subsidence of 0.08 mm/year (95% CI: 0.05-0.12, p < 0.001) was seen in combination with continued rotation in retroversion of 0.07°/year (95% CI: 0.02-0.12, p = 0.01). At 10 years of follow-up, mean subsidence was 2.1 (SD 1.2) mm and mean retroversion was 1.8° (SD 2.0). Two-thirds of this occurred during the first 2 postoperative years. In the 3 stems with a complete circumferential cement fracture, a sudden and disproportionately high increase in subsidence was measured in the time period of occurrence. The Exeter femoral stem continues to migrate during the first decade after implantation. Absolute stability is not required for good long-term survival if this is compatible with the design of the implant.
- 8 March 2012
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 83 (2) , 129-134
Open AccessThe Exeter femoral stem continues to migrate during its first decade after implantation
Due to its collarless, double-tapered polished design, the Exeter femoral stem is known to migrate distally in the first 5 years after implantation. However, its long-term migration pattern has not been investigated. 39 consecutive patients (41 total hip arthroplasties) received a cemented Exeter stem and had prospective clinical and RSA follow-up. Patients were evaluated postoperatively at 6, 12, 26, and 52 weeks, and annually thereafter. Short-term results have been reported. In this study, the mean length of follow-up was 9.4 years (SD 3.2 years). No patients were lost to follow-up. 15 patients died during follow-up. No stems were revised. In 4 stems, fractures of the cement mantle were noted within the first 3 postoperative years. In 3 stems, this resulted in a complete circumferential cement mantle discontinuity. For the 37 well-performing stems, continuous but small migration was measured between 2 and 12 years of follow-up. Continued subsidence of 0.08 mm/year (95% CI: 0.05-0.12, p < 0.001) was seen in combination with continued rotation in retroversion of 0.07°/year (95% CI: 0.02-0.12, p = 0.01). At 10 years of follow-up, mean subsidence was 2.1 (SD 1.2) mm and mean retroversion was 1.8° (SD 2.0). Two-thirds of this occurred during the first 2 postoperative years. In the 3 stems with a complete circumferential cement fracture, a sudden and disproportionately high increase in subsidence was measured in the time period of occurrence. The Exeter femoral stem continues to migrate during the first decade after implantation. Absolute stability is not required for good long-term survival if this is compatible with the design of the implant.