Arundhuti Ganguly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arundhuti Ganguly has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Rebecca Fahrig
Department of Radiology, Stanford University, 1201 Welch Rd., Palo Alto, CA 94305
5 shared publicationsDaniel R. Bednarek
Toshiba Stroke Research Center, Department of Radiology, Department of Neurosurgery, Department of Physics, Department of Biophysics and Physiology, State University of New York at Buffalo, and Erie County Medical Center, Buffalo, New York 14214
3 shared publicationsAlex Schneider
SRI International, Menlo Park, California
2 shared publicationsBenjamin Keck
Department of Radiology, Stanford University, 1201 Welch Rd., Palo Alto, CA 94305
2 shared publications- Iacovos S. Kyprianou
Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland 20905
2 shared publications Jeffrey Simons
Department of Radiology, Stanford University, 1201 Welch Rd., Palo Alto, CA 94305
2 shared publications
Latest Publications
- 1 November 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (11) , 1441-1445
Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System
- 1 November 2016
- Published by Elsevier in Academic Radiology
- Vol. 23 (11) , 1441-1445
Reproducibility of Parenchymal Blood Volume Measurements Using an Angiographic C-arm CT System
- Open Access
- 14 July 2011
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (8) , 1525-1531
Cerebral CT Perfusion Using an Interventional C-Arm Imaging System: Cerebral Blood Flow Measurements
BACKGROUND AND PURPOSE: CTP imaging in the interventional suite could reduce delays to the start of image-guided interventions and help determine the treatment progress and end point. However, C-arms rotate slower than clinical CT scanners, making CTP challenging. We developed a cerebral CTP protocol for C-arm CBCT and evaluated it in an animal study. MATERIALS AND METHODS: Five anesthetized swine were imaged by using C-arm CBCT and conventional CT. The C-arm rotates in 4.3 seconds plus a 1.25-second turnaround, compared with 0.5 seconds for clinical CT. Each C-arm scan had 6 continuous bidirectional sweeps. Multiple scans each with a different delay to the start of an aortic arch iodinated contrast injection and a novel image reconstruction algorithm were used to increase temporal resolution. Three different scan sets (consisting of 6, 3, or 2 scans) and 3 injection protocols (3-mL/s 100%, 3-mL/s 67%, and 6-mL/s 50% contrast concentration) were studied. CBF maps for each scan set and injection were generated. The concordance and Pearson correlation coefficients (ρ and r) were calculated to determine the injection providing the best match between the following: the left and right hemispheres, and CT and C-arm CBCT. RESULTS: The highest ρ and r values (both 0.92) for the left and right hemispheres were obtained by using the 6-mL 50% iodinated contrast concentration injection. The same injection gave the best match for CT and C-arm CBCT for the 6-scan set (ρ = 0.77, r = 0.89). Some of the 3-scan and 2-scan protocols provided matches similar to those in CT. CONCLUSIONS: This study demonstrated that C-arm CBCT can produce CBF maps that correlate well with those from CTP.
- 14 July 2011
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (8) , 1525-1531
Open AccessCerebral CT Perfusion Using an Interventional C-Arm Imaging System: Cerebral Blood Flow Measurements
BACKGROUND AND PURPOSE: CTP imaging in the interventional suite could reduce delays to the start of image-guided interventions and help determine the treatment progress and end point. However, C-arms rotate slower than clinical CT scanners, making CTP challenging. We developed a cerebral CTP protocol for C-arm CBCT and evaluated it in an animal study. MATERIALS AND METHODS: Five anesthetized swine were imaged by using C-arm CBCT and conventional CT. The C-arm rotates in 4.3 seconds plus a 1.25-second turnaround, compared with 0.5 seconds for clinical CT. Each C-arm scan had 6 continuous bidirectional sweeps. Multiple scans each with a different delay to the start of an aortic arch iodinated contrast injection and a novel image reconstruction algorithm were used to increase temporal resolution. Three different scan sets (consisting of 6, 3, or 2 scans) and 3 injection protocols (3-mL/s 100%, 3-mL/s 67%, and 6-mL/s 50% contrast concentration) were studied. CBF maps for each scan set and injection were generated. The concordance and Pearson correlation coefficients (ρ and r) were calculated to determine the injection providing the best match between the following: the left and right hemispheres, and CT and C-arm CBCT. RESULTS: The highest ρ and r values (both 0.92) for the left and right hemispheres were obtained by using the 6-mL 50% iodinated contrast concentration injection. The same injection gave the best match for CT and C-arm CBCT for the 6-scan set (ρ = 0.77, r = 0.89). Some of the 3-scan and 2-scan protocols provided matches similar to those in CT. CONCLUSIONS: This study demonstrated that C-arm CBCT can produce CBF maps that correlate well with those from CTP.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7964, 79641W
Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging
Brain perfusion CT using a C-arm angiography system capable of CT-like imaging could optimize patient treatment during stroke therapy procedures. For this application, an intra-arterial contrast bolus injection at the aortic arch could be used provided that the location of the injection catheter enables uniform distribution of the bolus into the two common carotid arteries (CCA). In this work, we present a novel method to support optimal injection catheter placement by providing additional quantitative information about the distribution of the contrast bolus into the CCAs. Our fully automatic method uses 2-D digital subtraction angiography (DSA) images following a test bolus injection. It segments both CCAs and computes the relative contrast distribution. We have tested the method in DSA data sets from 5 healthy pigs and our method achieved successful segmentation of both CCAs in all data sets. The results showed that the contrast is uniformly distributed (mean relative difference less or equal than 10%) if the injection location is properly chosen.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7964, 79641W
Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging
Brain perfusion CT using a C-arm angiography system capable of CT-like imaging could optimize patient treatment during stroke therapy procedures. For this application, an intra-arterial contrast bolus injection at the aortic arch could be used provided that the location of the injection catheter enables uniform distribution of the bolus into the two common carotid arteries (CCA). In this work, we present a novel method to support optimal injection catheter placement by providing additional quantitative information about the distribution of the contrast bolus into the CCAs. Our fully automatic method uses 2-D digital subtraction angiography (DSA) images following a test bolus injection. It segments both CCAs and computes the relative contrast distribution. We have tested the method in DSA data sets from 5 healthy pigs and our method achieved successful segmentation of both CCAs in all data sets. The results showed that the contrast is uniformly distributed (mean relative difference less or equal than 10%) if the injection location is properly chosen.
- 1 February 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (2) , 244-249
In-vivo Imaging of Femoral Artery Nitinol Stents for Deformation Analysis
- 1 February 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (2) , 244-249
In-vivo Imaging of Femoral Artery Nitinol Stents for Deformation Analysis
- 1 February 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (2) , 236-243
In-vitro Imaging of Femoral Artery Nitinol Stents for Deformation Analysis
- 1 February 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (2) , 236-243
In-vitro Imaging of Femoral Artery Nitinol Stents for Deformation Analysis
- 28 April 2010
- Published by Wiley in Medical Physics
- Vol. 37 (5) , 2264-2268
Dose and detectability for a cone‐beam C‐arm CT system revisited
Purpose: The authors had previously published measurements of the detectability of disk‐shaped contrast objects in images obtained from a C‐arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to. A more detailed analysis based on recent theoretical modeling of C‐arm CT images is presented in this work.Methods: The signal and noise propagations in a C‐arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x‐ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose‐criteria‐based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results.Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to and , respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose‐criterion‐based normalization.Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.
- 28 April 2010
- Published by Wiley in Medical Physics
- Vol. 37 (5) , 2264-2268
Dose and detectability for a cone‐beam C‐arm CT system revisited
Purpose: The authors had previously published measurements of the detectability of disk‐shaped contrast objects in images obtained from a C‐arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to. A more detailed analysis based on recent theoretical modeling of C‐arm CT images is presented in this work.Methods: The signal and noise propagations in a C‐arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x‐ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose‐criteria‐based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results.Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to and , respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose‐criterion‐based normalization.Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.
- 22 May 2007
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 25 (6) , 1219-1225
Quantitative evaluation of the relaxivity effects of iodine on GD‐DTPA enhanced MR arthrography
Purpose To quantify the effect of iodine on the gadolinium (Gd) contrast‐enhanced signal in MR arthrography. Materials and Methods Saline solutions of Gd contrast agent (0–1 mmol/liter) were mixed with iodinated contrast agent (0–185 mmol/liter). The T1 and T2 relaxation constants of these solutions were measured at 1.5T. Different types of commonly used iodinated contrast agents as well as sodium iodide (NaI) solutions were also analyzed. Results Iodine caused significant T2 shortening and some T1 shortening in Gd contrast solutions. Both contrast agents independently obeyed the standard relaxation relation, and their mixture obeyed a modified version of this relation. The side chains in various iodine molecules and their viscosities affected the relaxation properties differently. For various spin‐echo (SE) sequences, the signal from synovial fluid containing different concentrations of the two contrast agents was calculated. The T2‐weighted signal appeared to be most affected by the increase in iodine concentrations. In the absence of Gd contrast, all SE sequences showed an initial increase in signal from iodine contrast. Conclusion A generalized relation for the relaxivities of Gd contrast in the presence of iodine was established. The side chains of iodine contrast were found to alter the relaxivities of Gd contrast. Imaging with proton density (PD)‐weighted SE with only iodine contrast agent was found to be feasible. J. Magn. Reson. Imaging 2007;25:1219–1225.
- 22 May 2007
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 25 (6) , 1219-1225
Quantitative evaluation of the relaxivity effects of iodine on GD‐DTPA enhanced MR arthrography
Purpose To quantify the effect of iodine on the gadolinium (Gd) contrast‐enhanced signal in MR arthrography. Materials and Methods Saline solutions of Gd contrast agent (0–1 mmol/liter) were mixed with iodinated contrast agent (0–185 mmol/liter). The T1 and T2 relaxation constants of these solutions were measured at 1.5T. Different types of commonly used iodinated contrast agents as well as sodium iodide (NaI) solutions were also analyzed. Results Iodine caused significant T2 shortening and some T1 shortening in Gd contrast solutions. Both contrast agents independently obeyed the standard relaxation relation, and their mixture obeyed a modified version of this relation. The side chains in various iodine molecules and their viscosities affected the relaxation properties differently. For various spin‐echo (SE) sequences, the signal from synovial fluid containing different concentrations of the two contrast agents was calculated. The T2‐weighted signal appeared to be most affected by the increase in iodine concentrations. In the absence of Gd contrast, all SE sequences showed an initial increase in signal from iodine contrast. Conclusion A generalized relation for the relaxivities of Gd contrast in the presence of iodine was established. The side chains of iodine contrast were found to alter the relaxivities of Gd contrast. Imaging with proton density (PD)‐weighted SE with only iodine contrast agent was found to be feasible. J. Magn. Reson. Imaging 2007;25:1219–1225.
- 1 September 2005
- Published by Elsevier in Academic Radiology
- Vol. 12 (9) , 1167-1177
Truly Hybrid X-Ray/MR Imaging: Toward a Streamlined Clinical System1
- 1 September 2005
- Published by Elsevier in Academic Radiology
- Vol. 12 (9) , 1167-1177
Truly Hybrid X-Ray/MR Imaging: Toward a Streamlined Clinical System1
- 24 October 2003
- Published by Wiley in Medical Physics
- Vol. 30 (11) , 3029-3039
Micro‐angiography for neuro‐vascular imaging. II. Cascade model analysis
A micro‐angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x‐ray detectors for neuro‐interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and a zero frequency detective quantum efficiency [DQE(0)] value of about 55%. An assessment of the system was required to evaluate whether the current system was performing at its full potential and to determine if any of its components could be optimized to further improve the output. For the purpose, in this study, the parallel cascade theory was used to analyze the performance of the detector under neuro‐angiographic conditions by studying the output at the various stages in the imaging chain. A simple model for the spread of light in the CsI(Tl) entrance phosphor was developed and the resolution degradation due to ‐fluorescence absorption was calculated. The total gain of the system was found to result in (rms) detected at the charge coupled device per absorbed x‐ray photon. The gain and the spread of quanta in the imaging chain were used to calculate theoretically the DQE using the parallel cascade model. The results of the model‐based calculations matched fairly well with the experimental data previously obtained. This model was then used to optimize the phosphor thickness for the detector. The results showed that the area under the DQE curve had a maximum value at 150 μm of CsI(Tl), though when weighted by the squared signal in frequency space of a 100‐μm‐diam iodinated vessel, the integral DQE reached a maximum at 250 μm of CsI(Tl). Further, possible locations for gain increase in the imaging chain were determined, and the output of the improved system was simulated. Thus a theoretical analysis for the micro‐angiographic detector was performed to better assess its potential.
- 24 October 2003
- Published by Wiley in Medical Physics
- Vol. 30 (11) , 3029-3039
Micro‐angiography for neuro‐vascular imaging. II. Cascade model analysis
A micro‐angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x‐ray detectors for neuro‐interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and a zero frequency detective quantum efficiency [DQE(0)] value of about 55%. An assessment of the system was required to evaluate whether the current system was performing at its full potential and to determine if any of its components could be optimized to further improve the output. For the purpose, in this study, the parallel cascade theory was used to analyze the performance of the detector under neuro‐angiographic conditions by studying the output at the various stages in the imaging chain. A simple model for the spread of light in the CsI(Tl) entrance phosphor was developed and the resolution degradation due to ‐fluorescence absorption was calculated. The total gain of the system was found to result in (rms) detected at the charge coupled device per absorbed x‐ray photon. The gain and the spread of quanta in the imaging chain were used to calculate theoretically the DQE using the parallel cascade model. The results of the model‐based calculations matched fairly well with the experimental data previously obtained. This model was then used to optimize the phosphor thickness for the detector. The results showed that the area under the DQE curve had a maximum value at 150 μm of CsI(Tl), though when weighted by the squared signal in frequency space of a 100‐μm‐diam iodinated vessel, the integral DQE reached a maximum at 250 μm of CsI(Tl). Further, possible locations for gain increase in the imaging chain were determined, and the output of the improved system was simulated. Thus a theoretical analysis for the micro‐angiographic detector was performed to better assess its potential.
- 24 October 2003
- Published by Wiley in Medical Physics
- Vol. 30 (11) , 3018-3028
Micro‐angiography for neuro‐vascular imaging. I. Experimental evaluation and feasibility
Minimally invasive image‐guided neuro‐vascular interventions require very high image‐resolution and quality, specifically over regions‐of‐interest (ROI) crucial to the procedure. ROI imaging or micro‐angiography, allows limited patient integral radiation dose while permitting rapid frame transfer of high‐resolution images. The design and performance of a charge coupled device (CCD) based x‐ray detector or micro‐angiographic camera was assessed for neuro‐vascular procedures. The detector consists of a 250‐μm‐thick CsI(Tl) phosphor fiber‐optically coupled through a 1.8:1 taper to a CCD chip, with an effective image pixel size of 50 μm and a frame rate of 5 fps in the 2:1 pixel‐binned mode. The characteristics of the camera including the modulation transfer function (MTF), the noise equivalent quanta, the detective quantum efficiency, observer studies, and the effect of geometric magnification were evaluated. The MTF was found to have nonzero (1.7%) value at the Nyquist frequency of 10 cycles/mm, while the DQE(0) had a value of All values were measured using head equivalent attenuating material in the beam at 80 kVp. Human observer studies performed using the 2 Alternative Forced Choice method revealed that iodinated vessels with inner diameter of 100 μm and 2 cm in length can be seen with a confidence level greater than 75%. The observer studies included a comparison with ideal observer performance calculations based on the integral signal to noise ratio in the image. Probabilities of visualization of various objects of interest in a neuro‐intervention, such as stents, were assessed. A geometric magnification of 1 was found to be best for imaging under neuro‐angiographic conditions. The detector appeared to satisfy all the demands of neuro‐angiography and showed promise as an improvement over existing angiographic detectors.
- 24 October 2003
- Published by Wiley in Medical Physics
- Vol. 30 (11) , 3018-3028
Micro‐angiography for neuro‐vascular imaging. I. Experimental evaluation and feasibility
Minimally invasive image‐guided neuro‐vascular interventions require very high image‐resolution and quality, specifically over regions‐of‐interest (ROI) crucial to the procedure. ROI imaging or micro‐angiography, allows limited patient integral radiation dose while permitting rapid frame transfer of high‐resolution images. The design and performance of a charge coupled device (CCD) based x‐ray detector or micro‐angiographic camera was assessed for neuro‐vascular procedures. The detector consists of a 250‐μm‐thick CsI(Tl) phosphor fiber‐optically coupled through a 1.8:1 taper to a CCD chip, with an effective image pixel size of 50 μm and a frame rate of 5 fps in the 2:1 pixel‐binned mode. The characteristics of the camera including the modulation transfer function (MTF), the noise equivalent quanta, the detective quantum efficiency, observer studies, and the effect of geometric magnification were evaluated. The MTF was found to have nonzero (1.7%) value at the Nyquist frequency of 10 cycles/mm, while the DQE(0) had a value of All values were measured using head equivalent attenuating material in the beam at 80 kVp. Human observer studies performed using the 2 Alternative Forced Choice method revealed that iodinated vessels with inner diameter of 100 μm and 2 cm in length can be seen with a confidence level greater than 75%. The observer studies included a comparison with ideal observer performance calculations based on the integral signal to noise ratio in the image. Probabilities of visualization of various objects of interest in a neuro‐intervention, such as stents, were assessed. A geometric magnification of 1 was found to be best for imaging under neuro‐angiographic conditions. The detector appeared to satisfy all the demands of neuro‐angiography and showed promise as an improvement over existing angiographic detectors.