Raimo Sepponen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Raimo Sepponen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Antti Ropponen
Aalto University
3 shared publications - Kim Henrik Blomqvist
Aalto University
2 shared publications - Matti Linnavuo
Aalto University, Finland
2 shared publications - Antti Kimmo Olavi Paukkunen
Electronics Department, School of Science and Technology, Aalto University, 00076 Aalto, Finland
1 shared publication - Heikki Roilas
Department of Public Health, South Karelia Health Services, Lappeenranta, Finland
1 shared publication - Henry Rimminen
Aalto University
1 shared publication
Latest Publications
- Open Access
- 20 November 2011
- Published by Springer Nature in Personal and Ubiquitous Computing
- Vol. 17 (1) , 159-167
A novel concept of a wearable information appliance using context-based human–computer interaction
- 20 November 2011
- Published by Springer Nature in Personal and Ubiquitous Computing
- Vol. 17 (1) , 159-167
Open AccessA novel concept of a wearable information appliance using context-based human–computer interaction
- Open Access
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 98
Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. Ten volunteers (5 men and 5 women, age: 22-60 y, BMI: 21-30 kg/m2, waist circumference: 73-108 cm) were measured with the BELA instrument and with cross-sectional magnetic resonance imaging (MRI) at the navel level, navel +5 cm and navel -5 cm. The BELA signal was compared with visceral and subcutaneous fat areas calculated from the MR images. The BELA signal did not correlate with subcutaneous fat area at any level, but correlated significantly with visceral fat area at the navel level and navel +5 cm. The correlation was best at level of navel +5 cm (R2 = 0.74, P < 0.005, SEE = 29.7 cm2, LOOCV = 40.1 cm2), where SEE is the standard error of the estimate and LOOCV is the root mean squared error of leave-one-out style cross-validation. The average estimate of repeatability of the BELA signal observed through the study was ±9.6 %. One of the volunteers had an exceptionally large amount of visceral fat, which was underestimated by BELA. The correlation of the BELA signal with the visceral but not with the subcutaneous fat area as measured by MRI is promising. The lack of correlation with the subcutaneous fat suggests that subcutaneous fat has a minor influence to the BELA signal. Further research will show if it is possible to develop a reliable low-cost method for the assessment of visceral fat either using BELA only or combining it, for example, with bioelectrical impedance measurement. The combination of these measurements may help assessing visceral fat in a large scale of body composition. Before large-scale clinical testing and ROC analysis, the initial BELA instrumentation requires improvements. The accuracy of the present equipment is not sufficient for such new technology.
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 98
Open AccessBody electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration
Body electrical loss analysis (BELA) is a new non-invasive way to assess visceral fat depot size through the use of electromagnetism. BELA has worked well in phantom measurements, but the technology is not yet fully validated. Ten volunteers (5 men and 5 women, age: 22-60 y, BMI: 21-30 kg/m2, waist circumference: 73-108 cm) were measured with the BELA instrument and with cross-sectional magnetic resonance imaging (MRI) at the navel level, navel +5 cm and navel -5 cm. The BELA signal was compared with visceral and subcutaneous fat areas calculated from the MR images. The BELA signal did not correlate with subcutaneous fat area at any level, but correlated significantly with visceral fat area at the navel level and navel +5 cm. The correlation was best at level of navel +5 cm (R2 = 0.74, P < 0.005, SEE = 29.7 cm2, LOOCV = 40.1 cm2), where SEE is the standard error of the estimate and LOOCV is the root mean squared error of leave-one-out style cross-validation. The average estimate of repeatability of the BELA signal observed through the study was ±9.6 %. One of the volunteers had an exceptionally large amount of visceral fat, which was underestimated by BELA. The correlation of the BELA signal with the visceral but not with the subcutaneous fat area as measured by MRI is promising. The lack of correlation with the subcutaneous fat suggests that subcutaneous fat has a minor influence to the BELA signal. Further research will show if it is possible to develop a reliable low-cost method for the assessment of visceral fat either using BELA only or combining it, for example, with bioelectrical impedance measurement. The combination of these measurements may help assessing visceral fat in a large scale of body composition. Before large-scale clinical testing and ROC analysis, the initial BELA instrumentation requires improvements. The accuracy of the present equipment is not sufficient for such new technology.
- 30 November 2010
- Published by Springer Nature in Wireless Personal Communications
- Vol. 59 (1) , 57-71
Robust System for Indoor Localisation and Identification for the Health Care Environment
- 30 November 2010
- Published by Springer Nature in Wireless Personal Communications
- Vol. 59 (1) , 57-71
Robust System for Indoor Localisation and Identification for the Health Care Environment
- Open Access
- 1 January 2010
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 65
A feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis
Tomographic imaging has revealed that the body mass index does not give a reliable state of overall fitness. However, high measurement costs make the tomographic imaging unsuitable for large scale studies or repeated individual use. This paper reports an experimental investigation of a new electromagnetic method and its feasibility for assessing body composition. The method is called body electrical loss analysis (BELA). The BELA method uses a high-Q parallel resonant circuit to produce a time-varying magnetic field. The Q of the resonator changes when the sample is placed in its coil. This is caused by induced eddy currents in the sample. The new idea in the BELA method is the altered spatial distribution of the electrical losses generated by these currents. The distribution of losses is varied using different excitation frequencies. The feasibility of the method was tested using simplified phantoms. Two of these phantoms were rough estimations of human torso. One had fat in the middle of its volume and saline solution in the outer shell volume. The other had reversed conductivity distributions. The phantoms were placed in the resonator and the change in the losses was measured. Five different excitation frequencies from 100 kHz to 200 kHz were used. The rate of loss as a function of frequency was observed to be approximately three times larger for a phantom with fat in the middle of its volume than for one with fat in its outer shell volume. At higher frequencies the major signal contribution can be shifted toward outer shell volume. This enables probing the conductivity distribution of the subject by weighting outer structural components. The authors expect that the loss changing rate over frequency can be a potential index for body composition analysis.
- 1 January 2010
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 9 (1) , 65
Open AccessA feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis
Tomographic imaging has revealed that the body mass index does not give a reliable state of overall fitness. However, high measurement costs make the tomographic imaging unsuitable for large scale studies or repeated individual use. This paper reports an experimental investigation of a new electromagnetic method and its feasibility for assessing body composition. The method is called body electrical loss analysis (BELA). The BELA method uses a high-Q parallel resonant circuit to produce a time-varying magnetic field. The Q of the resonator changes when the sample is placed in its coil. This is caused by induced eddy currents in the sample. The new idea in the BELA method is the altered spatial distribution of the electrical losses generated by these currents. The distribution of losses is varied using different excitation frequencies. The feasibility of the method was tested using simplified phantoms. Two of these phantoms were rough estimations of human torso. One had fat in the middle of its volume and saline solution in the outer shell volume. The other had reversed conductivity distributions. The phantoms were placed in the resonator and the change in the losses was measured. Five different excitation frequencies from 100 kHz to 200 kHz were used. The rate of loss as a function of frequency was observed to be approximately three times larger for a phantom with fat in the middle of its volume than for one with fat in its outer shell volume. At higher frequencies the major signal contribution can be shifted toward outer shell volume. This enables probing the conductivity distribution of the subject by weighting outer structural components. The authors expect that the loss changing rate over frequency can be a potential index for body composition analysis.
- Open Access
- 3 December 2009
- Published by Springer Nature in BMC Geriatrics
- Vol. 9 (1) , 55
A new method to assess perceived well-being among elderly people - a feasibility study
A simple but countable electronic device has been developed to gain reliable information on elderly patients' perceived well-being. The device has been tested and proven to be technically functional and countable. It was now tested in two care homes for the elderly and two private homes to evaluate if it provided solid information about the well-being of elderly persons. This report illustrates the practical usage of the device and shows its efficiency in gathering solid well-being information from the focus group.
- 3 December 2009
- Published by Springer Nature in BMC Geriatrics
- Vol. 9 (1) , 55
Open AccessA new method to assess perceived well-being among elderly people - a feasibility study
A simple but countable electronic device has been developed to gain reliable information on elderly patients' perceived well-being. The device has been tested and proven to be technically functional and countable. It was now tested in two care homes for the elderly and two private homes to evaluate if it provided solid information about the well-being of elderly persons. This report illustrates the practical usage of the device and shows its efficiency in gathering solid well-being information from the focus group.
- Open Access
- 1 January 2009
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 2 (1) , 94-117
LF Indoor Location and Identification System
In this paper, a low-frequency RFID location system based on a matrix of quad antennae placed under a floor surface is described. A prototype system was used for parameterisation and feasibility tests. The results show that it is possible to build a location system using floor quad antennae.
- 1 January 2009
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 2 (1) , 94-117
Open AccessLF Indoor Location and Identification System
In this paper, a low-frequency RFID location system based on a matrix of quad antennae placed under a floor surface is described. A prototype system was used for parameterisation and feasibility tests. The results show that it is possible to build a location system using floor quad antennae.
- 29 July 2008
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 46 (9) , 933-938
The effect of ground electrode on the sensitivity, symmetricity and technical feasibility of scalp EEG recordings
Although the choice of the measurement reference strongly affects the measurement sensitivity, validity and comparability, selection is often based on tradition, convenience and comparability to earlier results [Dien in Behav Res Methods Ins C 30(1):34–43, 1998; Femi and Sundor in Int J Psychosom 36(1-4):23–33; 1989]. Artificial means can be applied to compensate for the referential issues, but they cannot restore any lost data. The validity of the recorded data is ultimately defined by the hardware setup. In this simulation study, common average ground reference (AR) is characterized and compared to two alternative common ground reference schemes in respect to their influence on the sensitivity distribution and technical feasibility of scalp EEG recording. It was found that, despite the polar average reference effect [Junghöfer et al. in Clin Neurophysiol 110(6):1149–1155; 1999], AR merits a significantly higher symmetricity and should be promoted generally not only in high-electrode-density studies, but also in low-channel-count studies if the stringent design requirements can be met. In low-electrode-density studies, balancing the setup may prove challenging, but successful implementation can provide nearly undistorted data. Isolation of the system is a critical parameter, but technological advances enable the requirements to be fulfilled. A physical ground should be applied if high isolation is not applicable or if it is defined by the application. The results will apply for the applied homogenous concentric 3-sphere model, but should be further studied in a realistic context if more detailed and case-sensitive information is required; the underlying phenomena are generally applicable.
- 29 July 2008
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 46 (9) , 933-938
The effect of ground electrode on the sensitivity, symmetricity and technical feasibility of scalp EEG recordings
Although the choice of the measurement reference strongly affects the measurement sensitivity, validity and comparability, selection is often based on tradition, convenience and comparability to earlier results [Dien in Behav Res Methods Ins C 30(1):34–43, 1998; Femi and Sundor in Int J Psychosom 36(1-4):23–33; 1989]. Artificial means can be applied to compensate for the referential issues, but they cannot restore any lost data. The validity of the recorded data is ultimately defined by the hardware setup. In this simulation study, common average ground reference (AR) is characterized and compared to two alternative common ground reference schemes in respect to their influence on the sensitivity distribution and technical feasibility of scalp EEG recording. It was found that, despite the polar average reference effect [Junghöfer et al. in Clin Neurophysiol 110(6):1149–1155; 1999], AR merits a significantly higher symmetricity and should be promoted generally not only in high-electrode-density studies, but also in low-channel-count studies if the stringent design requirements can be met. In low-electrode-density studies, balancing the setup may prove challenging, but successful implementation can provide nearly undistorted data. Isolation of the system is a critical parameter, but technological advances enable the requirements to be fulfilled. A physical ground should be applied if high isolation is not applicable or if it is defined by the application. The results will apply for the applied homogenous concentric 3-sphere model, but should be further studied in a realistic context if more detailed and case-sensitive information is required; the underlying phenomena are generally applicable.