Akihiro Hattori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Akihiro Hattori has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kenji Yasuda
Tokyo Medical and Dental University
20 shared publications - Hideyuki Terazono
Tokyo Medical and Dental University
16 shared publications - Masahito Hayashi
Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, Tokyo, Japan
11 shared publications Hyonchol Kim
Tokyo Medical and Dental University
8 shared publications- Tomoyuki Kaneko
Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
6 shared publications Fumimasa Nomura
Tokyo Medical and Dental University
4 shared publications
Latest Publications
- 1 January 2016
- Published by Surface Science Society Japan in Hyomen Kagaku
- Vol. 37 (5) , 213-217
On-Chip Cellomics Technology: Soft Nanotechnology for Constructive Cell Network Research for Life Science, Drug Discovery, and Medical Diagnostics
- 1 January 2016
- Published by Surface Science Society Japan in Hyomen Kagaku
- Vol. 37 (5) , 213-217
On-Chip Cellomics Technology: Soft Nanotechnology for Constructive Cell Network Research for Life Science, Drug Discovery, and Medical Diagnostics
- 1 January 2014
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 54 (supplement) , S247
2P318 Investigation of wide range optical set-up for simultaneous realtime analysis of 96-well SBS formatted samples(28. Bioengineering,Poster,The 52nd Annual Meeting of the Biophysical Society of Japan(BSJ2014))
- 1 January 2014
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 54 (supplement) , S247
2P318 Investigation of wide range optical set-up for simultaneous realtime analysis of 96-well SBS formatted samples(28. Bioengineering,Poster,The 52nd Annual Meeting of the Biophysical Society of Japan(BSJ2014))
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S158
1P316 Development of On-chip Multi-imaging Flow Cytometer System using Real-time Bright Field/Fluorescent Dual Image Analysis High-speed Camera(28. Bioengineering,Poster)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S158
1P316 Development of On-chip Multi-imaging Flow Cytometer System using Real-time Bright Field/Fluorescent Dual Image Analysis High-speed Camera(28. Bioengineering,Poster)
- 1 June 2012
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (6S) , 06FK08
Cell-Sorting System with On-Chip Imaging for Label-Free Shape-Based Selection of Cells
We have developed a novel cell-sorting system involving microscopic imaging using a poly(methyl methacrylate) (PMMA)-based microfluidic chip with a pair of gel electrodes and real-time image-processing procedures for the quantification of cell shapes. The features of this system are as follows. 1) It can recognize cells both by microscopic cell imaging with a 10,000 event/s high-speed camera and by the photodetection of fluorescence. 2) Multistage sorting is used to reduce errors to an infinitesimally low level by using a pair of wide agarose-gel electrodes. 3) Carry-over-free analysis can be performed using a disposable microfluidic chip. 4) An field programmable gate array (FPGA) 10,000 event/s real-time image analysis unit for quantifying the cell images in cell sorting. To separate the target cells from other cells on the basis of the cell shape, we adopted an index of roughness for the cell surface R, which compares the actual perimeter of cell surface and the estimated perimeter of cross-sectional view of cell shape by approximating the cell as a sphere. Sample cells flowing through microchannels on the chip were distinguished by the dual recognition system involving optical analysis and a fluorescence detector, and then separated. Target cells could be sorted automatically by applying an electrophoretic force, and the sorting ability depended on the precision with which cells were shifted within the laminar flow. These results indicate that the cell-sorting system with on-chip imaging is practically applicable for biological research and clinical diagnostics.
- 1 June 2012
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (6S) , 06FK08
Cell-Sorting System with On-Chip Imaging for Label-Free Shape-Based Selection of Cells
We have developed a novel cell-sorting system involving microscopic imaging using a poly(methyl methacrylate) (PMMA)-based microfluidic chip with a pair of gel electrodes and real-time image-processing procedures for the quantification of cell shapes. The features of this system are as follows. 1) It can recognize cells both by microscopic cell imaging with a 10,000 event/s high-speed camera and by the photodetection of fluorescence. 2) Multistage sorting is used to reduce errors to an infinitesimally low level by using a pair of wide agarose-gel electrodes. 3) Carry-over-free analysis can be performed using a disposable microfluidic chip. 4) An field programmable gate array (FPGA) 10,000 event/s real-time image analysis unit for quantifying the cell images in cell sorting. To separate the target cells from other cells on the basis of the cell shape, we adopted an index of roughness for the cell surface R, which compares the actual perimeter of cell surface and the estimated perimeter of cross-sectional view of cell shape by approximating the cell as a sphere. Sample cells flowing through microchannels on the chip were distinguished by the dual recognition system involving optical analysis and a fluorescence detector, and then separated. Target cells could be sorted automatically by applying an electrophoretic force, and the sorting ability depended on the precision with which cells were shifted within the laminar flow. These results indicate that the cell-sorting system with on-chip imaging is practically applicable for biological research and clinical diagnostics.
- Open Access
- 13 January 2012
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 13 (1) , 819-827
Evaluation of a Centrifuged Double Y-Shape Microfluidic Platform for Simple Continuous Cell Environment Exchange
We have demonstrated the efficacy of a microfluidic medium exchange method for single cells using passive centrifugal force of a rotating microfluidic-chip based platform. At the boundary of two laminar flows at the gathering area of two microfluidic pathways in a Y-shape, the cells were successfully transported from one laminar flow to the other, without mixing the two microfluidic mediums of the two laminar flows during cell transportation, within 5 s with 1 g (150 rpm) to 36.3 g (900 rpm) acceleration, with 93.5% efficiency. The results indicate that this is one of the most simple and precise tools for exchanging medium in the shortest amount of time.
- 13 January 2012
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 13 (1) , 819-827
Open AccessEvaluation of a Centrifuged Double Y-Shape Microfluidic Platform for Simple Continuous Cell Environment Exchange
We have demonstrated the efficacy of a microfluidic medium exchange method for single cells using passive centrifugal force of a rotating microfluidic-chip based platform. At the boundary of two laminar flows at the gathering area of two microfluidic pathways in a Y-shape, the cells were successfully transported from one laminar flow to the other, without mixing the two microfluidic mediums of the two laminar flows during cell transportation, within 5 s with 1 g (150 rpm) to 36.3 g (900 rpm) acceleration, with 93.5% efficiency. The results indicate that this is one of the most simple and precise tools for exchanging medium in the shortest amount of time.
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S154
3PS046 A Non-destructive Culturing and Cell Sorting Method for Cardiomyocytes and Neurons Using an Alginate Layer(The 50th Annual Meeting of the Biophysical Society of Japan)
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S154
3PS046 A Non-destructive Culturing and Cell Sorting Method for Cardiomyocytes and Neurons Using an Alginate Layer(The 50th Annual Meeting of the Biophysical Society of Japan)
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S154-S155
3PS049 Quantitative evaluation of cell separation method based on shape recognition using on-chip imaging cell sorter(The 50th Annual Meeting of the Biophysical Society of Japan)
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S154-S155
3PS049 Quantitative evaluation of cell separation method based on shape recognition using on-chip imaging cell sorter(The 50th Annual Meeting of the Biophysical Society of Japan)
- Open Access
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S149-S150
3PS023 Development of Dual Recording Assay for Cardiac Function Measurement using Electrical Field Potential and Optical Image Analysis(The 50th Annual Meeting of the Biophysical Society of Japan)
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S149-S150
Open Access3PS023 Development of Dual Recording Assay for Cardiac Function Measurement using Electrical Field Potential and Optical Image Analysis(The 50th Annual Meeting of the Biophysical Society of Japan)
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 30 September 2011
- Published by Elsevier in Neuroscience Research
- Vol. 71, e414
Construction of an artificial neuronal network and electrophysiological measurement with a selective collection method of cultured primary neurons
- 30 September 2011
- Published by Elsevier in Neuroscience Research
- Vol. 71, e414
Construction of an artificial neuronal network and electrophysiological measurement with a selective collection method of cultured primary neurons
- Open Access
- 7 June 2011
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 12 (6) , 3618-3634
Fully Automated On-Chip Imaging Flow Cytometry System with Disposable Contamination-Free Plastic Re-Cultivation Chip
We have developed a novel imaging cytometry system using a poly(methyl methacrylate (PMMA)) based microfluidic chip. The system was contamination-free, because sample suspensions contacted only with a flammable PMMA chip and no other component of the system. The transparency and low-fluorescence of PMMA was suitable for microscopic imaging of cells flowing through microchannels on the chip. Sample particles flowing through microchannels on the chip were discriminated by an image-recognition unit with a high-speed camera in real time at the rate of 200 event/s, e.g., microparticles 2.5 μm and 3.0 μm in diameter were differentiated with an error rate of less than 2%. Desired cells were separated automatically from other cells by electrophoretic or dielectrophoretic force one by one with a separation efficiency of 90%. Cells in suspension with fluorescent dye were separated using the same kind of microfluidic chip. Sample of 5 μL with 1 × 106 particle/mL was processed within 40 min. Separated cells could be cultured on the microfluidic chip without contamination. The whole operation of sample handling was automated using 3D micropipetting system. These results showed that the novel imaging flow cytometry system is practically applicable for biological research and clinical diagnostics.
- 7 June 2011
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 12 (6) , 3618-3634
Open AccessFully Automated On-Chip Imaging Flow Cytometry System with Disposable Contamination-Free Plastic Re-Cultivation Chip
We have developed a novel imaging cytometry system using a poly(methyl methacrylate (PMMA)) based microfluidic chip. The system was contamination-free, because sample suspensions contacted only with a flammable PMMA chip and no other component of the system. The transparency and low-fluorescence of PMMA was suitable for microscopic imaging of cells flowing through microchannels on the chip. Sample particles flowing through microchannels on the chip were discriminated by an image-recognition unit with a high-speed camera in real time at the rate of 200 event/s, e.g., microparticles 2.5 μm and 3.0 μm in diameter were differentiated with an error rate of less than 2%. Desired cells were separated automatically from other cells by electrophoretic or dielectrophoretic force one by one with a separation efficiency of 90%. Cells in suspension with fluorescent dye were separated using the same kind of microfluidic chip. Sample of 5 μL with 1 × 106 particle/mL was processed within 40 min. Separated cells could be cultured on the microfluidic chip without contamination. The whole operation of sample handling was automated using 3D micropipetting system. These results showed that the novel imaging flow cytometry system is practically applicable for biological research and clinical diagnostics.