Hideyuki Terazono
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hideyuki Terazono has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Kenji Yasuda
Tokyo Medical and Dental University
23 shared publications - Akihiro Hattori
Kanagawa Academy of Science and Technology
16 shared publications Hyonchol Kim
Tokyo Medical and Dental University
14 shared publications- Masahito Hayashi
Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, Tokyo, Japan
10 shared publications Hiroyuki Takei
KAST:Fac. Life Sci., Toyo Univ
8 shared publicationsFumimasa Nomura
Tokyo Medical and Dental University
6 shared publications
Latest Publications
- 1 January 2016
- Published by Surface Science Society Japan in Hyomen Kagaku
- Vol. 37 (5) , 213-217
On-Chip Cellomics Technology: Soft Nanotechnology for Constructive Cell Network Research for Life Science, Drug Discovery, and Medical Diagnostics
- 1 January 2016
- Published by Surface Science Society Japan in Hyomen Kagaku
- Vol. 37 (5) , 213-217
On-Chip Cellomics Technology: Soft Nanotechnology for Constructive Cell Network Research for Life Science, Drug Discovery, and Medical Diagnostics
- 1 January 2015
- Published by Elsevier in Biophysical Journal
- Vol. 108 (2) , 111a
On-Chip Quasi-in vivo Predictive Cardiotoxicity Assay using Spatiotemporal Fluctuation Measurement on Human Cardiomyocyte Cell-Network
- 1 January 2015
- Published by Elsevier in Biophysical Journal
- Vol. 108 (2) , 111a
On-Chip Quasi-in vivo Predictive Cardiotoxicity Assay using Spatiotemporal Fluctuation Measurement on Human Cardiomyocyte Cell-Network
- 1 January 2014
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 54 (supplement) , S247
2P318 Investigation of wide range optical set-up for simultaneous realtime analysis of 96-well SBS formatted samples(28. Bioengineering,Poster,The 52nd Annual Meeting of the Biophysical Society of Japan(BSJ2014))
- 1 January 2014
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 54 (supplement) , S247
2P318 Investigation of wide range optical set-up for simultaneous realtime analysis of 96-well SBS formatted samples(28. Bioengineering,Poster,The 52nd Annual Meeting of the Biophysical Society of Japan(BSJ2014))
- 1 January 2014
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 54 (supplement) , S228
2P201 Quasi-in vivo pre-clinical model for cardiac toxicity using spatiotemporal fluctuation measurement on human cardiomyocyte cell-network(12. Cell biology,Poster)
- 1 January 2014
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 54 (supplement) , S228
2P201 Quasi-in vivo pre-clinical model for cardiac toxicity using spatiotemporal fluctuation measurement on human cardiomyocyte cell-network(12. Cell biology,Poster)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S263
3P309 Fabrication of Superparamagnetic Metal Cups for Size-Selective Cell Collection(28.Bioengineering,Poster,The 51st Annual Meeting of the Biophysical Society of Japan)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S263
3P309 Fabrication of Superparamagnetic Metal Cups for Size-Selective Cell Collection(28.Bioengineering,Poster,The 51st Annual Meeting of the Biophysical Society of Japan)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S263
3P310 Non-invasive identification and purification method of target cardiomyocyte cells using cell-surface-binding ssDNA aptamers(28.Bioengineering,Poster,The 51st Annual Meeting of the Biophysical Society of Japan)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S263
3P310 Non-invasive identification and purification method of target cardiomyocyte cells using cell-surface-binding ssDNA aptamers(28.Bioengineering,Poster,The 51st Annual Meeting of the Biophysical Society of Japan)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S207
2P290 Importance of spatial arrangement and community size on cardiomyocyte network for precise and stable in vitro drug screening measurement(26. Measurements,Poster)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S207
2P290 Importance of spatial arrangement and community size on cardiomyocyte network for precise and stable in vitro drug screening measurement(26. Measurements,Poster)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S158
1P316 Development of On-chip Multi-imaging Flow Cytometer System using Real-time Bright Field/Fluorescent Dual Image Analysis High-speed Camera(28. Bioengineering,Poster)
- 1 January 2013
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 53 (supplement) , S158
1P316 Development of On-chip Multi-imaging Flow Cytometer System using Real-time Bright Field/Fluorescent Dual Image Analysis High-speed Camera(28. Bioengineering,Poster)
- 1 June 2012
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (6S) , 06FK08
Cell-Sorting System with On-Chip Imaging for Label-Free Shape-Based Selection of Cells
We have developed a novel cell-sorting system involving microscopic imaging using a poly(methyl methacrylate) (PMMA)-based microfluidic chip with a pair of gel electrodes and real-time image-processing procedures for the quantification of cell shapes. The features of this system are as follows. 1) It can recognize cells both by microscopic cell imaging with a 10,000 event/s high-speed camera and by the photodetection of fluorescence. 2) Multistage sorting is used to reduce errors to an infinitesimally low level by using a pair of wide agarose-gel electrodes. 3) Carry-over-free analysis can be performed using a disposable microfluidic chip. 4) An field programmable gate array (FPGA) 10,000 event/s real-time image analysis unit for quantifying the cell images in cell sorting. To separate the target cells from other cells on the basis of the cell shape, we adopted an index of roughness for the cell surface R, which compares the actual perimeter of cell surface and the estimated perimeter of cross-sectional view of cell shape by approximating the cell as a sphere. Sample cells flowing through microchannels on the chip were distinguished by the dual recognition system involving optical analysis and a fluorescence detector, and then separated. Target cells could be sorted automatically by applying an electrophoretic force, and the sorting ability depended on the precision with which cells were shifted within the laminar flow. These results indicate that the cell-sorting system with on-chip imaging is practically applicable for biological research and clinical diagnostics.
- 1 June 2012
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 51 (6S) , 06FK08
Cell-Sorting System with On-Chip Imaging for Label-Free Shape-Based Selection of Cells
We have developed a novel cell-sorting system involving microscopic imaging using a poly(methyl methacrylate) (PMMA)-based microfluidic chip with a pair of gel electrodes and real-time image-processing procedures for the quantification of cell shapes. The features of this system are as follows. 1) It can recognize cells both by microscopic cell imaging with a 10,000 event/s high-speed camera and by the photodetection of fluorescence. 2) Multistage sorting is used to reduce errors to an infinitesimally low level by using a pair of wide agarose-gel electrodes. 3) Carry-over-free analysis can be performed using a disposable microfluidic chip. 4) An field programmable gate array (FPGA) 10,000 event/s real-time image analysis unit for quantifying the cell images in cell sorting. To separate the target cells from other cells on the basis of the cell shape, we adopted an index of roughness for the cell surface R, which compares the actual perimeter of cell surface and the estimated perimeter of cross-sectional view of cell shape by approximating the cell as a sphere. Sample cells flowing through microchannels on the chip were distinguished by the dual recognition system involving optical analysis and a fluorescence detector, and then separated. Target cells could be sorted automatically by applying an electrophoretic force, and the sorting ability depended on the precision with which cells were shifted within the laminar flow. These results indicate that the cell-sorting system with on-chip imaging is practically applicable for biological research and clinical diagnostics.
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S154
3PS047 Fabrication of Superparamagnetic Janus Particles Having Various Sizes and Its Application for Non-Destructive Cell Sorting(The 50th Annual Meeting of the Biophysical Society of Japan)
- 1 January 2012
- Published by Biophysical Society of Japan in Seibutsu Butsuri
- Vol. 52 (supplement) , S154
3PS047 Fabrication of Superparamagnetic Janus Particles Having Various Sizes and Its Application for Non-Destructive Cell Sorting(The 50th Annual Meeting of the Biophysical Society of Japan)