ACAidan J. Cloonan

Aidan J. Cloonan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aidan J. Cloonan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Anna. V. Piterina

    Department of Chemical and Environmental Sciences, Material and Surface Science Institute, University of Limerick, Limerick, Ireland

    1 shared publication
  • Anthony Callanan

    Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical and Aeronautical Engineering and Materials and Surface Science Institute, University of Limerick, Ireland

    1 shared publication
  • Barry J. Doyle

    School of Engineering, The University of Western Australia, Perth, WA, Australia

    1 shared publication
  • Claire L. Meaney

    Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical & Aeronautical Engineering, and Materials and Surface Science Institute (MSSI), University of Limerick, Limerick, Ireland

    1 shared publication
  • Danial Shahmirzadi

    Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, New York

    1 shared publication
  • Dinesh Babu Duraibabu

    Department of Mechatronic Engineering, School of Engineering and Design, Atlantic Technological University, Ash Ln, Ballytivnan, F91 YW50 Sligo, Ireland

    1 shared publication

Latest Publications

  • Open Access

    Fabrication and Qualitative Analysis of an Optical Fibre EFPI-Based Temperature Sensor

    by Fintan McGuinness, Aidan Cloonan, Mohamed Oubaha, Dinesh Babu Duraibabu, M. Mahmood Ali, Gerald Kilkelly, Emma Tobin, Gabriel Leen

    The following presents a comparison of an extrinsic Fabry–Perot interferometer (EFPI)-based temperature sensor, constructed using a novel diaphragm manufacturing technique, with a reference all-glass EFPI temperature sensor. The novel diaphragm was manufactured using polyvinyl alcohol (PVA). The novel sensor fabrication involved fusing a single-mode fibre (SMF) to a length of fused quartz capillary, which has an inner diameter of 132 μm and a 220 μm outer diameter. The capillary was subsequently polished until the distal face of the capillary extended approximately 60 μm beyond that of the single mode fibre. Upon completion of polishing, the assembly is immersed in a solution of PVA. Controlled extraction resulted in creation of a thin diaphragm while simultaneously applying a protective coating to the fusion point of the SMF and capillary. The EFPI sensor is subsequently sealed in a second fluid-filled capillary, thereby creating a novel temperature sensor structure. Both temperature sensors were placed in a thermogravimetric analyser and heated from an indicated 30 °C to 100 °C to qualitatively compare sensitivities. Initial results indicated that the novel manufacturing technique both expedited production and produces a more sensitive sensor when compared to an all-glass construction.


  • 3D-Printed Tissue-Mimicking Phantoms for Medical Imaging and Computational Validation Applications

    by Aidan J. Cloonan, Danial Shahmirzadi, Ronny X. Li, Barry J. Doyle, Elisa E. Konofagou, Tim M. McGloughlin

    Abdominal aortic aneurysm (AAA) is a permanent, irreversible dilation of the distal region of the aorta. Recent efforts have focused on improved AAA screening and biomechanics-based failure prediction. Idealized and patient-specific AAA phantoms are often employed to validate numerical models and imaging modalities. To produce such phantoms, the investment casting process is frequently used, reconstructing the 3D vessel geometry from computed tomography patient scans. In this study the alternative use of 3D printing to produce phantoms is investigated. The mechanical properties of flexible 3D-printed materials are benchmarked against proven elastomers. We demonstrate the utility of this process with particular application to the emerging imaging modality of ultrasound-based pulse wave imaging, a noninvasive diagnostic methodology being developed to obtain regional vascular wall stiffness properties, differentiating normal and pathologic tissue in vivo. Phantom wall displacements under pulsatile loading conditions were observed, showing good correlation to fluid–structure interaction simulations and regions of peak wall stress predicted by finite element analysis. 3D-printed phantoms show a strong potential to improve medical imaging and computational analysis, potentially helping bridge the gap between experimental and clinical diagnostic tools.


  • Open Access

    ECM-Based Materials in Cardiovascular Applications: Inherent Healing Potential and Augmentation of Native Regenerative Processes

    by Anna V. Piterina, Aidan J. Cloonan, Claire L. Meaney, Laura M. Davis, Anthony Callanan, Michael T. Walsh, Tim M. McGloughlin

    The in vivo healing process of vascular grafts involves the interaction of many contributing factors. The ability of vascular grafts to provide an environment which allows successful accomplishment of this process is extremely difficult. Poor endothelisation, inflammation, infection, occlusion, thrombosis, hyperplasia and pseudoaneurysms are common issues with synthetic grafts in vivo. Advanced materials composed of decellularised extracellular matrices (ECM) have been shown to promote the healing process via modulation of the host immune response, resistance to bacterial infections, allowing re-innervation and reestablishing homeostasis in the healing region. The physiological balance within the newly developed vascular tissue is maintained via the recreation of correct biorheology and mechanotransduction factors including host immune response, infection control, homing and the attraction of progenitor cells and infiltration by host tissue. Here, we review the progress in this tissue engineering approach, the enhancement potential of ECM materials and future prospects to reach the clinical environment.