TOTakako Oyabu

Takako Oyabu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takako Oyabu has a total of 88 co-authors. Here are the top co-authors by number of shared publications:

  • Yasuo Morimoto

    Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Japan

    8 shared publications
  • Manabu Shimada

    Chemical Engineering Program, Graduate School of Advanced Science and Engineering, Hiroshima University, 4-1, Kagamiyama 1-chome, Higashi-Hiroshima 739-8527, Hiroshima, Japan

    6 shared publications
  • Masaru Kubo

    Chemical Engineering Program, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1, Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8527, Japan

    6 shared publications
  • Toshihiko Myojo

    Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Japan. Kitakyushu, Japan

    6 shared publications
  • Byeong-Woo Lee

    Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu, Fukuoka 807-8555, Japan

    5 shared publications
  • Hiroto Izumi

    Center for Stress-Related Disease Control and Prevention, University of Occupational and Environmental Health, Kitakyushu 807-8555, Japan

    5 shared publications

Latest Publications

  • Open Access

    Assessment of Cytokine-Induced Neutrophil Chemoattractants as Biomarkers for Prediction of Pulmonary Toxicity of Nanomaterials

    by Taisuke Tomonaga, Hiroto Izumi, Takako Oyabu, Byeong-Woo Lee, Masaru Kubo, Manabu Shimada, Shingo Noguchi, Chinatsu Nishida, Kazuhiro Yatera, Yasuo Morimoto

    This work determines whether cytokine-induced neutrophil chemoattractants (CINC)-1, CINC-2 and CINC-3 can be markers for predicting high or low pulmonary toxicity of nanomaterials (NMs). We classified NMs of nickel oxide (NiO) and cerium dioxide (CeO2) into high toxicity and NMs of two types of titanium dioxides (TiO2 (P90 and rutile)) and zinc oxide (ZnO) into low toxicity, and we analyzed previous data of CINCs in bronchoalveolar lavage fluid (BALF) of rats from three days to six months after intratracheal instillation (0.2 and 1.0 mg) and inhalation exposure (0.32–10.4 mg/m3) of materials (NiO, CeO2, TiO2 (P90 and rutile), ZnO NMs and micron-particles of crystalline silica (SiO2)). The concentration of CINC-1 and CINC-2 in BALF had different increase tendency between high and low pulmonary toxicity of NMs and correlated with the other inflammatory markers in BALF. However, CINC-3 increased only slightly in a dose-dependent manner compared with CINC-1 and CINC-2. Analysis of receiver operating characteristics for the toxicity of NMs by CINC-1 and CINC-2 showed the most accuracy of discrimination of the toxicity at one week or one month after exposure and CINC-1 and CINC-2 in BALF following intratracheal instillation of SiO2 as a high toxicity could accurately predict the toxicity at more than one month after exposure. These data suggest that CINC-1 and CINC-2 may be useful biomarkers for the prediction of pulmonary toxicity of NMs relatively early in both intratracheal instillation and inhalation exposure.


  • Open Access

    Usefulness of myeloperoxidase as a biomarker for the ranking of pulmonary toxicity of nanomaterials

    by Taisuke Tomonaga, Hiroto Izumi, Yukiko Yoshiura, Toshihiko Myojo, Takako Oyabu, Byeong-Woo Lee, Takami Okada, Takashi Marui, Ke-Yong Wang, Masaru Kubo, et al.

    In order to examine whether myeloperoxidase (MPO) can be a useful marker for evaluating the pulmonary toxicity of nanomaterials, we analyzed MPO protein in bronchoalveolar lavage fluid (BALF) samples obtained from previous examinations of a rat model. In those examinations we performed intratracheal instillation exposures (dose: 0.2–1.0 mg) and inhalation exposures (exposure concentration: 0.32–10.4 mg/m3) using 9 and 4 nanomaterials with different toxicities, respectively. Based on those previous studies, we set Nickel oxide nanoparticles (NiO), cerium dioxide nanoparticles (CeO2), multi wall carbon nanotubes with short or long length (MWCNT (S) and MWCNT (L)), and single wall carbon nanotube (SWCNT) as chemicals with high toxicity; and titanium dioxide nanoparticles (TiO2 (P90) and TiO2 (Rutile)), zinc oxide nanoparticles (ZnO), and toner with external additives including nanoparticles as chemicals with low toxicity. We measured the concentration of MPO in BALF samples from rats from 3 days to 6 months following a single intratracheal instillation, and from 3 days to 3 months after the end of inhalation exposure. Intratracheal instillation of high toxicity NiO, CeO2, MWCNT (S), MWCNT (L), and SWCNT persistently increased the concentration of MPO, and inhalation of NiO and CeO2 increased the MPO in BALF. By contrast, intratracheal instillation of low toxicity TiO2 (P90), TiO2 (Rutile), ZnO, and toner increased the concentration of MPO in BALF only transiently, and inhalation of TiO2 (Rutile) and ZnO induced almost no increase of the MPO. The concentration of MPO correlated with the number of total cells and neutrophils, the concentration of chemokines for neutrophils (cytokine-induced neutrophil chemoattractant (CINC)-1 and heme oxygenase (HO)-1), and the activity of released lactate dehydrogenase (LDH) in BALF. The results from the receiver operating characteristics (ROC) for the toxicity of chemicals by the concentration of MPO proteins in the intratracheal instillation and inhalation exposures showed that the largest areas under the curves (AUC) s in both examinations occurred at 1 month after exposure. These data suggest that MPO can be a useful biomarker for the ranking of the pulmonary toxicity of nanomaterials, especially at 1 month after exposure, in both intratracheal instillation and inhalation exposure.


  • Open Access

    Biopersistence of NiO and TiO2 Nanoparticles Following Intratracheal Instillation and Inhalation

    by Takako Oyabu, Toshihiko Myojo, Byeong-Woo Lee, Takami Okada, Hiroto Izumi, Yukiko Yoshiura, Taisuke Tomonaga, Yun-Shan Li, Kazuaki Kawai, Manabu Shimada, et al.

    The hazards of various types of nanoparticles with high functionality have not been fully assessed. We investigated the usefulness of biopersistence as a hazard indicator of nanoparticles by performing inhalation and intratracheal instillation studies and comparing the biopersistence of two nanoparticles with different toxicities: NiO and TiO2 nanoparticles with high and low toxicity among nanoparticles, respectively. In the 4-week inhalation studies, the average exposure concentrations were 0.32 and 1.65 mg/m3 for NiO, and 0.50 and 1.84 mg/m3 for TiO2. In the instillation studies, 0.2 and 1.0 mg of NiO nanoparticles and 0.2, 0.36, and 1.0 mg of TiO2 were dispersed in 0.4 mL water and instilled to rats. After the exposure, the lung burden in each of five rats was determined by Inductively Coupled Plasma-Atomic Emission Spectrometer (ICP-AES) from 3 days to 3 months for inhalation studies and to 6 months for instillation studies. In both the inhalation and instillation studies, NiO nanoparticles persisted for longer in the lung compared with TiO2 nanoparticles, and the calculated biological half times (BHTs) of the NiO nanoparticles was longer than that of the TiO2 nanoparticles. Biopersistence also correlated with histopathological changes, inflammatory response, and other biomarkers in bronchoalveolar lavage fluid (BALF) after the exposure to nanoparticles. These results suggested that the biopersistence is a good indicator of the hazards of nanoparticles.


  • Open Access

    Evaluation of Pulmonary Toxicity of Zinc Oxide Nanoparticles Following Inhalation and Intratracheal Instillation

    by Yasuo Morimoto, Hiroto Izumi, Yukiko Yoshiura, Taisuke Tomonaga, Takako Oyabu, Toshihiko Myojo, Kazuaki Kawai, Kazuhiro Yatera, Manabu Shimada, Masaru Kubo, et al.

    We conducted inhalation and intratracheal instillation studies of zinc oxide (ZnO) nanoparticles in order to examine their pulmonary toxicity. F344 rats were received intratracheal instillation at 0.2 or 1 mg of ZnO nanoparticles with a primary diameter of 35 nm that were well-dispersed in distilled water. Cell analysis and chemokines in bronchoalveolar lavage fluid (BALF) were analyzed at three days, one week, one month, three months, and six months after the instillation. As the inhalation study, rats were exposed to a concentration of inhaled ZnO nanoparticles (2 and 10 mg/m3) for four weeks (6 h/day, 5 days/week). The same endpoints as in the intratracheal instillation study were analyzed at three days, one month, and three months after the end of the exposure. In the intratracheal instillation study, both the 0.2 and the 1.0 mg ZnO groups had a transient increase in the total cell and neutrophil count in the BALF and in the expression of cytokine-induced neutrophil chemoattractant (CINC)-1, CINC-2, chemokine for neutrophil, and heme oxygenase-1 (HO-1), an oxidative stress marker, in the BALF. In the inhalation study, transient increases in total cell and neutrophil count, CINC-1,-2 and HO-1 in the BALF were observed in the high concentration groups. Neither of the studies of ZnO nanoparticles showed persistent inflammation in the rat lung, suggesting that well-dispersed ZnO nanoparticles have low toxicity.


  • Open Access

    Comparison of the Pulmonary Oxidative Stress Caused by Intratracheal Instillation and Inhalation of NiO Nanoparticles when Equivalent Amounts of NiO Are Retained in the Lung

    by Masanori Horie, Yukiko Yoshiura, Hiroto Izumi, Takako Oyabu, Taisuke Tomonaga, Takami Okada, Byeong-Woo Lee, Toshihiko Myojo, Masaru Kubo, Manabu Shimada, et al.

    NiO nanoparticles were administered to rat lungs via intratracheal instillation or inhalation. During pulmonary toxicity caused by NiO nanoparticles, the induction of oxidative stress is a major factor. Both intratracheal instillation and inhalation of NiO nanoparticles induced pulmonary oxidative stress. The oxidative stress response protein, heme oxygenase-1 (HO-1), was induced by the administration of NiO nanoparticles at both the protein and gene expression level. Additionally, certain oxidative-stress markers in the lung, such as 8-iso-prostaglandin F2α, thioredoxin, and inducible nitric oxide synthase were increased. Furthermore, the concentration of myeloperoxidase (MPO) in the lung was also increased by the administration of NiO nanoparticles. When the amount of NiO in the lung is similar, the responses against pulmonary oxidative stress of intratracheal instillation and inhalation are also similar. However, the state of pulmonary oxidative stress in the early phase was different between intratracheal instillation and inhalation, even if the amount of NiO in the lung was similar. Inhalation causes milder oxidative stress than that caused by intratracheal instillation. On evaluation of the nanoparticle-induced pulmonary oxidative stress in the early phase, we should understand the different states of oxidative stress induced by intratracheal instillation and inhalation.


  • Open Access

    Comparison between whole-body inhalation and nose-only inhalation on the deposition and health effects of nanoparticles

    by Takako Oyabu, Yasuo Morimoto, Hiroto Izumi, Yukiko Yoshiura, Taisuke Tomonaga, Byeong-Woo Lee, Takami Okada, Toshihiko Myojo, Manabu Shimada, Masaru Kubo, et al.

    Objectives We performed the two inhalation exposures, whole-body inhalation and nose-only inhalation, to investigate the pulmonary deposition and health effects of the two inhalation methods. Methods In both methods, we exposed rats to the same TiO2 nanoparticles at almost the same exposure concentration for 6 h and compared the deposited amounts of nanoparticles and histopathological changes in the lungs. Rats were exposed to rutile-type TiO2 nanoparticles generated by the spray-dry method for 6 h. The exposure concentration in the whole-body chamber was 4.10 ± 1.07 mg/m3, and that in nose-only chamber was 4.01 ± 1.11 mg/m3. The particle sizes were 230 and 180 nm, respectively. A control group was exposed to fresh air. Results The amounts of TiO2 deposited in the lungs as measured by ICP-AES after acid digestion just after the exposure were: 42.6 ± 3.5 μg in the whole-body exposure and 46.0 ± 7.7 μg in the nose-only exposure groups. The histopathological evaluation was the same in both exposure groups: no infiltration of inflammatory cells in the alveolar space and interstitium, and no fibrosis. Conclusion The two inhalation methods using the same material under the same exposure conditions resulted in the same particle deposition and histopathology in the lung.


  • Open Access

    Pulmonary Inflammation of Well-Dispersed Multi-Wall Carbon Nanotubes Following Intratracheal Instillation: Toxicity by Fiber of 1–5 µm in Length

    by Masanori Horie, Mayumi Stowe, Tatsunori Kambara, Byeong Woo Lee, Shigehisa Endoh, Junko Maru, Takako Oyabu, Toshihiko Myojo, Akira Ogami, Kunio Uchida, et al.

    The pulmonary toxicity of multi-wall carbon nanotubes (MWCNT) were examined by intratracheal instillation. We prepared a well-dispersed MWCNT dispersion including MWCNTs of 3.71 µm geometric average length. The fiber length of most of the MWCNTs in the dispersion was 10 µm or less. The MWCNT dispersion was administered to rat lung by single intratracheal instillation at doses of 0.2 mg and 0.6 mg/rat. Bronchoalveolar lavage fluid (BALF) was collected at 3 days, 1 week, 1 month, 3 months, and 6 months after instillation. The influences of the longer MWCNTs on the induction of inflammation and oxidative stress were examined by the number of neutrophils, cytokine induced neutrophil chemoattractant-1 (CINC-1), CINC-2, CINC-3 and HO-1 in the BALF. Additionally, ho-1 gene expression in the lung was examined. The intratracheal instillation of MWCNT induced transient inflammation dose dependently in the lung. The number of neutrophils was highest at 3 days after instillation and then decreased. However, the neutrophils in the MWCNT administered animals tended to be higher than in the control group until 3 months after instillation. The CINC-1 and CINC-2 concentrations in the BALF increased at 1 month after instillation. There were no significant differences in CINC-3 and HO-1 between the MWCNT administered animals and the control animals. These results revealed that the MWCNTs of 1–10 µm in length induced persistent inflammation in rat lung. There were no remarkable differences between the MWCNTs in the present study and previously reported, shorter MWCNTs prepared from “the same” raw MWCNT material.


  • Biopersistence of inhaled MWCNT in rat lungs in a 4-week well-characterized exposure

    by Takako Oyabu, Toshihiko Myojo, Yasuo Morimoto, Akira Ogami, Masami Hirohashi, Makoto Yamamoto, Motoi Todoroki, Yohei Mizuguchi, Masayoshi Hashiba, Byeong Woo Lee, et al.

    It is important to conduct a risk assessment that includes hazard assessment and exposure assessment for the safe production and handling of newly developed nanomaterials. We conducted an inhalation study of a multi-wall carbon nanotube (MWCNT) as a hazard assessment. Male Wistar rats were exposed to well-dispersed MWCNT for 4 weeks by whole body inhalation. The exposure concentration in the chamber was 0.37 ± 0.18 mg/m3. About 70% of the MWCNTs in the chamber were single fiber. The geometric mean diameter (geometric standard deviation, GSD) and geometric mean length (GSD) of the aerosolized MWCNTs in the chamber were 63 nm (1.5) and 1.1 μm (2.7), respectively. The amounts of MWCNT deposited in the rat lungs were determined by the X-ray diffraction method and elemental carbon analysis. The average deposited amounts at 3 days after the inhalation were 68 μg/lung by the X-ray diffraction method and 76 μg/lung by elemental carbon analysis. The calculated deposition fractions were 18% and 20% in each analysis. The amount of retained MWCNT in the lungs until 3 months after the inhalation decreased exponentially and the calculated biological half times of MWCNT were 51 days and 54 days, respectively. The clearance was not delayed, but a slight increase in lung weight at 3 days after the inhalation was observed.


  • Open Access

    Inflammogenic effect of well-characterized fullerenes in inhalation and intratracheal instillation studies

    by Yasuo Morimoto, Masami Hirohashi, Akira Ogami, Takako Oyabu, Toshihiko Myojo, Ken-Ichiro Nishi, Chikara Kadoya, Motoi Todoroki, Makoto Yamamoto, Masahiro Murakami, et al.

    We used fullerenes, whose dispersion at the nano-level was stabilized by grinding in nitrogen gas in an agitation mill, to conduct an intratracheal instillation study and an inhalation exposure study. Fullerenes were individually dispersed in distilled water including 0.1% Tween 80, and the diameter of the fullerenes was 33 nm. These suspensions were directly injected as a solution in the intratracheal instillation study. The reference material was nickel oxide in distilled water. Wistar male rats intratracheally received a dose of 0.1 mg, 0.2 mg, or 1 mg of fullerenes and were sacrificed after 3 days, 1 week, 1 month, 3 months, and 6 months. In the inhalation study, Wistar rats were exposed to fullerene agglomerates (diameter: 96 ± 5 nm; 0.12 ± 0.03 mg/m3; 6 hours/days for 5 days/week) for 4 weeks and were sacrificed at 3 days, 1 month, and 3 months after the end of exposure. The inflammatory responses and gene expression of cytokine-induced neutrophil chemoattractants (CINCs) were examined in rat lungs in both studies.


  • Open Access

    Simple Flow‐through Solubility Measurement Apparatus and its Effectiveness for Hazard Assessment of Particles/Fibers

    by Takako Oyabu, Akira Ogami, Yasuo Morimoto, Toshihiko Myojo, Masahiro Murakami, Hiroshi Yamato, Isamu Tanaka

    Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies