TMToshihiko Myojo

Toshihiko Myojo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Toshihiko Myojo has a total of 75 co-authors. Here are the top co-authors by number of shared publications:

  • Takako Oyabu

    Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu, Fukuoka 807-8555, Japan

    6 shared publications
  • Yasuo Morimoto

    Department of Occupational Pneumology, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Japan

    6 shared publications
  • Chikara Kadoya

    Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health KitakyushuJapan

    5 shared publications
  • Isamu Tanaka

    Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health KitakyushuJapan

    5 shared publications
  • Manabu Shimada

    Chemical Engineering Program, Graduate School of Advanced Science and Engineering, Hiroshima University, 4-1, Kagamiyama 1-chome, Higashi-Hiroshima 739-8527, Hiroshima, Japan

    5 shared publications
  • Takako Oyabu

    Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health KitakyushuJapan

    5 shared publications

Latest Publications

  • Open Access

    Combining Indoor Positioning Using Wi-Fi Round Trip Time with Dust Measurement in the Field of Occupational Health

    by Hajime Ando, Shingo Sekoguchi, Kazunori Ikegami, Hidetaka Yoshitake, Hiroka Baba, Toshihiko Myojo, Akira Ogami

    Monitoring of personal exposure to hazardous substances has garnered increasing attention over the past few years. However, no straightforward and exact indoor positioning technique has been available until the recent discovery of Wi-Fi round trip time (Wi-Fi RTT). In this study, we investigated the possibility of using a combination of Wi-Fi RTT for indoor positioning and a wearable particle monitor (WPM) to observe dust concentration during walking in a simulated factory. Ultrasonic humidifiers were used to spray sodium chloride solution inside the factory. The measurements were recorded three times on different routes (Experiments A, B, and C). The error percentages, i.e., measurements that were outside the expected measurement area, were 7% (49 s/700 s) in Experiment A, 2.3% (15 s/660 s) in Experiment B, and 7.8% (50 s/645 s) in Experiment C. The dust measurements were also recorded without any obstruction. A heat map was created based on the results from both measured values. Wi-Fi RTT proved useful for computing the indoor position with high accuracy, suggesting the applicability of the proposed methodology for occupational health monitoring.


  • Open Access

    Usefulness of myeloperoxidase as a biomarker for the ranking of pulmonary toxicity of nanomaterials

    by Taisuke Tomonaga, Hiroto Izumi, Yukiko Yoshiura, Toshihiko Myojo, Takako Oyabu, Byeong-Woo Lee, Takami Okada, Takashi Marui, Ke-Yong Wang, Masaru Kubo, et al.

    In order to examine whether myeloperoxidase (MPO) can be a useful marker for evaluating the pulmonary toxicity of nanomaterials, we analyzed MPO protein in bronchoalveolar lavage fluid (BALF) samples obtained from previous examinations of a rat model. In those examinations we performed intratracheal instillation exposures (dose: 0.2–1.0 mg) and inhalation exposures (exposure concentration: 0.32–10.4 mg/m3) using 9 and 4 nanomaterials with different toxicities, respectively. Based on those previous studies, we set Nickel oxide nanoparticles (NiO), cerium dioxide nanoparticles (CeO2), multi wall carbon nanotubes with short or long length (MWCNT (S) and MWCNT (L)), and single wall carbon nanotube (SWCNT) as chemicals with high toxicity; and titanium dioxide nanoparticles (TiO2 (P90) and TiO2 (Rutile)), zinc oxide nanoparticles (ZnO), and toner with external additives including nanoparticles as chemicals with low toxicity. We measured the concentration of MPO in BALF samples from rats from 3 days to 6 months following a single intratracheal instillation, and from 3 days to 3 months after the end of inhalation exposure. Intratracheal instillation of high toxicity NiO, CeO2, MWCNT (S), MWCNT (L), and SWCNT persistently increased the concentration of MPO, and inhalation of NiO and CeO2 increased the MPO in BALF. By contrast, intratracheal instillation of low toxicity TiO2 (P90), TiO2 (Rutile), ZnO, and toner increased the concentration of MPO in BALF only transiently, and inhalation of TiO2 (Rutile) and ZnO induced almost no increase of the MPO. The concentration of MPO correlated with the number of total cells and neutrophils, the concentration of chemokines for neutrophils (cytokine-induced neutrophil chemoattractant (CINC)-1 and heme oxygenase (HO)-1), and the activity of released lactate dehydrogenase (LDH) in BALF. The results from the receiver operating characteristics (ROC) for the toxicity of chemicals by the concentration of MPO proteins in the intratracheal instillation and inhalation exposures showed that the largest areas under the curves (AUC) s in both examinations occurred at 1 month after exposure. These data suggest that MPO can be a useful biomarker for the ranking of the pulmonary toxicity of nanomaterials, especially at 1 month after exposure, in both intratracheal instillation and inhalation exposure.


  • Open Access

    Biopersistence of NiO and TiO2 Nanoparticles Following Intratracheal Instillation and Inhalation

    by Takako Oyabu, Toshihiko Myojo, Byeong-Woo Lee, Takami Okada, Hiroto Izumi, Yukiko Yoshiura, Taisuke Tomonaga, Yun-Shan Li, Kazuaki Kawai, Manabu Shimada, et al.

    The hazards of various types of nanoparticles with high functionality have not been fully assessed. We investigated the usefulness of biopersistence as a hazard indicator of nanoparticles by performing inhalation and intratracheal instillation studies and comparing the biopersistence of two nanoparticles with different toxicities: NiO and TiO2 nanoparticles with high and low toxicity among nanoparticles, respectively. In the 4-week inhalation studies, the average exposure concentrations were 0.32 and 1.65 mg/m3 for NiO, and 0.50 and 1.84 mg/m3 for TiO2. In the instillation studies, 0.2 and 1.0 mg of NiO nanoparticles and 0.2, 0.36, and 1.0 mg of TiO2 were dispersed in 0.4 mL water and instilled to rats. After the exposure, the lung burden in each of five rats was determined by Inductively Coupled Plasma-Atomic Emission Spectrometer (ICP-AES) from 3 days to 3 months for inhalation studies and to 6 months for instillation studies. In both the inhalation and instillation studies, NiO nanoparticles persisted for longer in the lung compared with TiO2 nanoparticles, and the calculated biological half times (BHTs) of the NiO nanoparticles was longer than that of the TiO2 nanoparticles. Biopersistence also correlated with histopathological changes, inflammatory response, and other biomarkers in bronchoalveolar lavage fluid (BALF) after the exposure to nanoparticles. These results suggested that the biopersistence is a good indicator of the hazards of nanoparticles.


  • Open Access

    The Effectiveness of Specific Risk Mitigation Techniques Used in the Production and Handling of Manufactured Nanomaterials: A Systematic Review

    by Toshihiko Myojo, Tomohisa Nagata, Jos Verbeek

    Many kinds of manufactured nanomaterials (MNMs) have been developed and used as basic materials of industrial products, and they may pose health risks for workers in not only developed countries but also in developing countries. Few studies have looked at the evidence for effects of controls that mitigate the risk of exposure to MNMs. Therefore, we systematically searched the literature from the year 2000 to 2015. We included studies that compared the use of an exposure control to the situation without such a technique and those that measured the exposure to MNMs as the outcome. In order to evaluate the effectiveness of these controls, we used their "protection factor", defined as the ratio between concentrations without and with the control. We located 1,131 references in PubMed and other lists, and out of these references, 41 studies fulfilled our inclusion criteria. We categorized them as engineering controls such as enclosure, local exhaust ventilation or process automation, and as personal protective equipment (PPE). For enclosure systems we found a protection factor beyond 100. For other engineering controls, the better controls scored 10 to 20, but many cases of local exhaust ventilation had a protection factor of less than 10 and some cases even increased exposure. PPE such as N95 or equivalent filtering respirators had a protection factor of approximately 10 tested with nano-sized aerosols. We conclude that there is low quality evidence that specific engineering controls can reduce exposure to MNMs but that enclosure is considerably more effective. For respiratory protection the evidence is of very low quality due to the lack of field studies. This information can be used to decide about controls when exposure to MNMs exceeds proposed occupational exposure limits or when no toxicological information is available for a MNM.


  • Open Access

    Evaluation of Pulmonary Toxicity of Zinc Oxide Nanoparticles Following Inhalation and Intratracheal Instillation

    by Yasuo Morimoto, Hiroto Izumi, Yukiko Yoshiura, Taisuke Tomonaga, Takako Oyabu, Toshihiko Myojo, Kazuaki Kawai, Kazuhiro Yatera, Manabu Shimada, Masaru Kubo, et al.

    We conducted inhalation and intratracheal instillation studies of zinc oxide (ZnO) nanoparticles in order to examine their pulmonary toxicity. F344 rats were received intratracheal instillation at 0.2 or 1 mg of ZnO nanoparticles with a primary diameter of 35 nm that were well-dispersed in distilled water. Cell analysis and chemokines in bronchoalveolar lavage fluid (BALF) were analyzed at three days, one week, one month, three months, and six months after the instillation. As the inhalation study, rats were exposed to a concentration of inhaled ZnO nanoparticles (2 and 10 mg/m3) for four weeks (6 h/day, 5 days/week). The same endpoints as in the intratracheal instillation study were analyzed at three days, one month, and three months after the end of the exposure. In the intratracheal instillation study, both the 0.2 and the 1.0 mg ZnO groups had a transient increase in the total cell and neutrophil count in the BALF and in the expression of cytokine-induced neutrophil chemoattractant (CINC)-1, CINC-2, chemokine for neutrophil, and heme oxygenase-1 (HO-1), an oxidative stress marker, in the BALF. In the inhalation study, transient increases in total cell and neutrophil count, CINC-1,-2 and HO-1 in the BALF were observed in the high concentration groups. Neither of the studies of ZnO nanoparticles showed persistent inflammation in the rat lung, suggesting that well-dispersed ZnO nanoparticles have low toxicity.


  • Open Access

    Comparison of the Pulmonary Oxidative Stress Caused by Intratracheal Instillation and Inhalation of NiO Nanoparticles when Equivalent Amounts of NiO Are Retained in the Lung

    by Masanori Horie, Yukiko Yoshiura, Hiroto Izumi, Takako Oyabu, Taisuke Tomonaga, Takami Okada, Byeong-Woo Lee, Toshihiko Myojo, Masaru Kubo, Manabu Shimada, et al.

    NiO nanoparticles were administered to rat lungs via intratracheal instillation or inhalation. During pulmonary toxicity caused by NiO nanoparticles, the induction of oxidative stress is a major factor. Both intratracheal instillation and inhalation of NiO nanoparticles induced pulmonary oxidative stress. The oxidative stress response protein, heme oxygenase-1 (HO-1), was induced by the administration of NiO nanoparticles at both the protein and gene expression level. Additionally, certain oxidative-stress markers in the lung, such as 8-iso-prostaglandin F2α, thioredoxin, and inducible nitric oxide synthase were increased. Furthermore, the concentration of myeloperoxidase (MPO) in the lung was also increased by the administration of NiO nanoparticles. When the amount of NiO in the lung is similar, the responses against pulmonary oxidative stress of intratracheal instillation and inhalation are also similar. However, the state of pulmonary oxidative stress in the early phase was different between intratracheal instillation and inhalation, even if the amount of NiO in the lung was similar. Inhalation causes milder oxidative stress than that caused by intratracheal instillation. On evaluation of the nanoparticle-induced pulmonary oxidative stress in the early phase, we should understand the different states of oxidative stress induced by intratracheal instillation and inhalation.


  • Analysis of pulmonary surfactant in rat lungs after intratracheal instillation of short and long multi-walled carbon nanotubes

    by Byeong-Woo Lee, Chikara Kadoya, Masanori Horie, Yohei Mizuguchi, Masayoshi Hashiba, Tatsunori Kambara, Takami Okada, Toshihiko Myojo, Takako Oyabu, Akira Ogami, et al.

    Multi-walled carbon nanotubes (MWCNTs) are interesting new materials, but there is some concern about their harmfulness due to their fibrous nature. To determine the difference in the biological effects of MWCMTs by fiber length, we prepared two MWCNT samples from one bulk sample. One consisted of cut up short fibers (Short; average length = 0.94 µm) and the other was just dispersed (Long; average length = 3.4 µm). The samples were administered to male Wistar rats by intratracheal instillation at doses of 0.2 mg and 1 mg/animal (Short) and 0.2 mg and 0.6 mg/animal (Long). The animals were sacrificed at time points from 3 d to 12 months after administration. Bronchoalveolar lavage fluid (BALF) was taken from the lungs and pathological specimens were prepared. The concentrations of phospholipids, total protein and surfactant protein D (SP-D) in the pulmonary surfactant of the BALF were determined, the surface tension of BALF was measured, and the inflammation score was determined by the point-counting method to assess pulmonary tissue inflammation. The present study suggests that inflammatory response in the lung was slightly higher for long MWCNTs than for short MWCNTs when compared at the same mass dose. The correlation between pulmonary surfactant components and BALF surface tension was also evaluated. The Spearman’s rank correlation coefficients obtained for the phospholipid, total protein and SP-D concentrations were −0.068 (p = 0.605), −0.360 (p = 0.005) and −0.673 (p = 0.000), respectively. Surface tension, measured by a simple method, should be reflected in the change of a surfactant protein, such as SP-D.


  • Comparison of dose-response relations between 4-week inhalation and intratracheal instillation of NiO nanoparticles using polimorphonuclear neutrophils in bronchoalveolar lavage fluid as a biomarker of pulmonary inflammation

    by Yohei Mizuguchi, Toshihiko Myojo, Takako Oyabu, Masayoshi Hashiba, Byeong Woo Lee, Makoto Yamamoto, Motoi Todoroki, Kenichiro Nishi, Chikara Kadoya, Akira Ogami, et al.

    Inhalation studies and intratracheal instillation studies using laboratory animals are commonly conducted for pulmonary toxicity tests of nanomaterials. In our study, male Wister rats were exposed to nickel oxide (NiO) particles including a nano-scale, even for aerosols and suspensions, in a 4-week inhalation and intratracheal instillation. Using polymorphonuclear neutrophils (PMNs) in bronchoalveolar lavage fluid as a biomarker of inflammation, we attempted to quantify the relationship between responses to inhalation and intratracheal instillation of the nanoparticles, based on surface area doses. Four kinds of NiO suspension samples with different specific surface areas were singly injected via the tracheas of the rats. The relationship between the instilled doses and PMN production was examined 3 days and 1 month after the instillation. In parallel, 4-week inhalation studies, using two of the suspensions, were conducted for aerosols generated by a pressurized nebulizer. NiO samples induced PMN responses 3 days after instillation according to the surface area doses, but not the mass doses, as has been reported in many studies. When the same NiO samples were tested in a 4-week inhalation and intratracheal instillation, the amount of pulmonary deposition of the sample after the 4-week inhalation, and an intratracheally instilled dose about ten-times higher, induced similar PMN responses 3 days after termination of inhalation and instillation. Using the relationship between these responses to 4-week inhalation and intratracheal instillation, it may be possible to estimate what aerosol concentrations of other nanomaterials might cause the same responses of PMN production as intratracheal instillation tests.


  • Open Access

    Pulmonary Inflammation of Well-Dispersed Multi-Wall Carbon Nanotubes Following Intratracheal Instillation: Toxicity by Fiber of 1–5 µm in Length

    by Masanori Horie, Mayumi Stowe, Tatsunori Kambara, Byeong Woo Lee, Shigehisa Endoh, Junko Maru, Takako Oyabu, Toshihiko Myojo, Akira Ogami, Kunio Uchida, et al.

    The pulmonary toxicity of multi-wall carbon nanotubes (MWCNT) were examined by intratracheal instillation. We prepared a well-dispersed MWCNT dispersion including MWCNTs of 3.71 µm geometric average length. The fiber length of most of the MWCNTs in the dispersion was 10 µm or less. The MWCNT dispersion was administered to rat lung by single intratracheal instillation at doses of 0.2 mg and 0.6 mg/rat. Bronchoalveolar lavage fluid (BALF) was collected at 3 days, 1 week, 1 month, 3 months, and 6 months after instillation. The influences of the longer MWCNTs on the induction of inflammation and oxidative stress were examined by the number of neutrophils, cytokine induced neutrophil chemoattractant-1 (CINC-1), CINC-2, CINC-3 and HO-1 in the BALF. Additionally, ho-1 gene expression in the lung was examined. The intratracheal instillation of MWCNT induced transient inflammation dose dependently in the lung. The number of neutrophils was highest at 3 days after instillation and then decreased. However, the neutrophils in the MWCNT administered animals tended to be higher than in the control group until 3 months after instillation. The CINC-1 and CINC-2 concentrations in the BALF increased at 1 month after instillation. There were no significant differences in CINC-3 and HO-1 between the MWCNT administered animals and the control animals. These results revealed that the MWCNTs of 1–10 µm in length induced persistent inflammation in rat lung. There were no remarkable differences between the MWCNTs in the present study and previously reported, shorter MWCNTs prepared from “the same” raw MWCNT material.


  • Monitoring of C60 aerosol concentrations during 4-week inhalation study using a carbon aerosol analyzer with adjusted analytical protocol

    by Toshihiko Myojo, Takako Oyabu, Akira Ogami, Masami Hirohashi, Masahiro Murakami, Makoto Yamamoto, Motoi Todoroki, Chikara Kadoya, Kenichiro Nishi, Sayumi Yamasaki, et al.